1. This drawing should be used in coordination with all other drawings presented for this project by the
consultant.
2. All dimensions are in millimeters unless otherwise specified.
3. DO NOT SCALE FROM DRAWINGS. For clarifications of dimensions, refer the Engineer.
4. The contractor shall review and verify all dimensions and coordinates prior to commencement of works.
5. All discrepancies shall be immediately reported to the Engineer. Failure to do so does not relieve the
A B C D E F G contractor of the responsibility of verification of all dimensions.
6. All works shall be carried out in accordance with QCS-2014 (Qatar Construction Specification) as a
minimum standard.
7. All Reinforcing bars shall be deformed high strength and shall conform to (QASCO) specification with
S-5103
minimum yield strength of 500 N/mm².
13
TB05 (1000X650)
300 KEY PLAN
RAMP - 1
SSL +0.050 RB01 (300X600)
QND+4.350 200
(WITH RAMP)
B05 (400x850)
CTB01 (1000X1200)
RB
LIGHT CONCRETE RB01 (300X600) (W 01
ITH (30
UP STEPS (WITH RAMP) RA 0X6
M 00 N
P) )
UP LIGHT CONCRETE
TB0
B02 (200X850)
6 (1
B04 (400x1200/650) STEPS
300
000
00)
0x8
X11
6 30
TB03 (1000X1200)
B08( SSL +0.100
00/
CORBEL 01 S-5102
TB03 (1000x1200)
QND+4.400
500
(800x1200/800)
)
2
TB03 (1000X1200)
B09 (300x600)
B02 (200X850)
UP
S-5102
REV DESCRIPTION DATE
B02 (200x850)
7
UP
TB03 (1000X1200)
SSL +0.050 LIGHT CONCRETE
300 QND+4.350 STEPS 0 ISSUED FOR TENDER 2023-02-12
1 ISSUED FOR TENDER 2023-06-25
SSL +0.600
125 QND+4.900 5
TB02 (
DECK SLAB S-5102
ICB03 (250x1250)
3
1000X
A B
IB01 (250x700)
S-5301 UP UP UP S-5301
1100)
150
DN
300 REVISIONS
CORBEL 01 ICB02 (250X700)
TB03 (1000X1200)
TB03 (
(800x1200/800) SSL -0.200
QND+4.100
4
1000X
4 S-5102 QR-Code MUNICIPALITY STAMP
1200)
UP
2
1
150 300 S-510
SSL +0.050
400 SSL +0.600
QND+4.350 TYP.(U.N.O) QND+4.900
TB02 (
SLAB ON GRADE
1000X
5
1100)
UP UP
150
TB03 (
SSL +0.050
1000X
QND+4.350
SLAB ON GRADE
1200)
CORBEL 01
TB03 (1000X1200)
(800x1200/800)
IB01 (250x700)
6
UP UP
DN UP ENQUIRY No. : Application No :
ICB01 (200x700)
150 CONSULTANT REG. No : GRADE: CONSULTANT REG. No : GRADE:
TB02 (
ICB02 (250x700) CONSULTANT STAMP & SIGNATURE : CONSULTANT STAMP & SIGNATURE :
1000X
B01 (250x600)
CORBEL 01
1100)
(800x1200/800) TB01 (800x1200)
7 8
TB03 (
UP S-5102 UP
1000X
TB03 (1000X1200)
B05 (400x850)
TB02 (
REGISTIRATION No.: REGISTIRATION No.:
B05 (400x850) B05 (400x850)
1
000x11
RB01 (300X600) (WITH RAMP) CONSULTANT
B05 (400x850)
00)
UP
B07 (400x1200) RB01 (300x600) (WITH RAMP) MASS CONCRETE B05 (400x850) B06 (400x1100)
8
STEPS
CB01 (400x850) BACCA
Architecture & Engineering Consultant
TB05 (
TB04 (
B03 (400x550)
200
1000x6
300
RAMP - 2
B03 (400x550)
1000x5
PRE-CAST
REMOVABLE
SSL +0.050 CLIENT/DEVELOPER
50)
200 SLAB
50)
QND+4.350
FOXHILLS-RES-E02
1 9 10 LOCATION: Enter address here PIN NO.: 69040328
S-5101 S-5102 S-5102
SHEET TITLE
Scale: 1:100
RES-E02-2202
STR Drawn
Author
Checked
Checker
Approved
Approver
A1
Drawing No. Revision
S-1002 01