Incremental Progress To Net Zero

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

GROUP MEMBERS

FINAL ENERGY USE


G2.1 ORIENTATION AND SHAPE (improved Case)kWh/month

North/south, 10m depth, rectangular shaped form,


9 floors above grade, no basement 24,453.62
East/West , 10m depth, rectangular shaped form,
9 floors above grade, no basement 24,453.62
North/south, 15m depth, rectangular shaped form,
9 floors above grade, no basement 24,453.62
North/south, 10m depth, rectangular shaped form,
5 floors above grade, no basement 24,453.62

North/south, 10m depth, H- shaped form connected at


the edges,
5 floors above grade, 1 basement 24,453.62

FINAL ENERGY USE


G2.2 WINDOW SIZING (improved Case)kWh/month
30% WWR 24,453.62
40%WWR 24,453.62
22%WWR 24,453.62

G2.3 ENERGY PERFORMANCE

improved energy
(without renewable
Baseline energy (kWh/m2/year energy)kWh/m2/year
65 41

off the EDGE app after


deselecting the renewables (solar and
off the EDGE app graph wind)

G2.4 WATER PERFORMANCE

Improved water
Baseline water (litres/year) (without recycling and rainwater)
8,896,875 4,790,625

35 litres/day/person(OFF the EDGE app


graph) x 365 (no.of days in 1 year) x
65litres/day/person(OFF the EDGE app graph) x 365 (4500/12)
(no.of days in 1 year) x (4500/12) floor area/occupants density/m2 (after
floor area/occupants density/m2 deselecting recycling and rainwater)
G2.5 MATERIALS PERFORMANCE (Embodied energy)
Baseline embodied energy (MJ/m2) improved embodied energy (MJ/M2)
3167 822
ENERGY SAVINGS%
(Improved case vs Base case)

6.09

-5.55

3.15

7.22

6.27

ENERGY SAVINGS%
(Improved case vs Base case)
12.27
9.36
14.43

improved energy (renewable


energy)
kWh/m2/year
7

75%(65% solar PV + 10% wind) of


the
improved energy without the
renewables

improved water
( recycling and rainwater)
(litres/year)
4,243,125

31 litres/day/person(OFF the
EDGE app graph) x 365 (no.of
days in 1 year) x (4500/12)
floor area/occupants density/m2
(after selecting only recycling and
rainwater)
Final embodied energy (MJ)
2345
OBSERVATIONS

Option one

East/west orientation negates energy savings

Marginal improvement in North/south with 15m buikding depth

Reduction in floor levels with a norrow depth improves energy savings

North?south orientation coupled with Reduction in floor levels and a norrow depth improves energy savings.

OBSERVATIONS
Base case WWR
Increasing WWR leads to a decrease in energy saving
Lower WWR improves energy savings.

net energy use/final energy use (kWh/m2/year


34

2,791.95kWh/m2/year x no of months in a year


divided by floor area (4500m2)

net water use/final water use (litres/year)


2,433,600

final water use (202.80m3/month) x 1000 (to convert to liters) x 12 (months per year)