SEISMIC DEFINITION

 Location of the Project: Bunawan, Panacan Davao City


 Fault Name: Central Davao Fault System
 Fault Segment: New- Carmen Fault
 Distance from the Location: 12.4 km
 Occupancy (Category): 5 – Story Commercial Building (Category III)
 Soil Type: Stiff Soil Profile
 Structure: Concrete
 Moment Resisting Frame: Special Reinforced Concrete
 Seismic Importance Factor, I = 1.0
 Seismic Zone: Zone 4 (Z = 0.4)
 Earthquake Source: M = 7.5 (Type A)
 Near – source Factor, Na = 0.91 (Type A)
 Near – source Factor, Nv = 0.91 (Type A)
 Seismic Coefficient, Ca = 0.44Na = 0.44(0.91) = 0.4004
 Seismic Coefficient, Cv = 0.64Nv = 0.64(0.91) = 0.5804
 Numerical Coefficient, Rx = Ry = 8.5

SEISMIC HAZARD PARAMETERS


FLUIDS (LOAD CASE)

WATER TANK LOAD = (unit weight of water) (height of the tank) = (9.81) (3) = 29.43 kN/m 2

DEADLOAD

For uniformly distributed Wall load = Unit wt. of wall x Thickness of wall x Height of wall

 For exterior wall & Interior wall = 150mm


22x0.15x3.6 =11.88 kN/m
22x0.15x3.4 =11.22 kN/m
22x0.15x1.2 = 3.96 kN/m

 For firewall = 200mm


22x0.2x3.6 =15.84 kN/m
22x0.2x3.4 =14.96 kN/m
22x0.2x1.2 = 5.28 kN/m

 For Glass Wall = 12mm


22x0.012x3.6 = 0.95 kN/m
22x0.012x3.4 = 0.90 kN/m
22x0.012x1.2 = 0.317 kN/m

 Wall at roofdeck
22x0.15x3 = 9.9 kN/m

For stair load


1ST FLOOR TO 2ND FLOOR
3.6 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
2RD FLOOR TO 3RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
3RD FLOOR TO 4RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
4RD FLOOR TO 5RD FLOOR
3.4 m
RISE = (elevation for FFL to Ceiling)/ (no. of steps in stairs) = = 0.189m
19 steps
UNIFORM LOAD = [(approx. thickness) (1 m width) (unit weight of concrete)] / (width of the stairs) = [(4.471 m
x 2 sides x 0.189m) (1.75 m) (23.56)] / (2) /(5) = 9.95 Kn/M = 10 Kn/m

For weight pressure:


Wp = (Unit wt. of concrete x thickness of the slab) + superimposed loads
Superimposed loads
 Tiles: 1.10
 Mechanical/electrical duct lines: 0.20
 Ceiling: 0.05
kN
Wp = (23.56 3 x 0.125) + (1.10 + 0.20 + 0.05) = 4.295 kpa
m

SPECIAL LIVE LOADS

 COMMON ELEVATOR = F =mg = (907 kg) (9.81) / 1000 = 8.898 kN


Load = (8.898 kN / 2.34 m2) (2) = 7.606 kN/m2

 SERVICE ELEVATOR = F =mg = (1135 kg) (9.81) / 1000 = 11.134 kN


Load = (11.134 kN / 3.75 m2) (2) = 5.938 kN/m2

NSCP 2015 LOAD FACTORS


 SUPERIMPOSED LOADS