Design
JONATHAN WOOD
USFilter, Lowell, Massachusetts
ERIN WESTBERG
Alliant Energy, Cedar Rapids, Iowa
DENNIS BLACKBOURN
Wisconsin Power and Light, Cassville, Wisconsin
IWC-03-37
Keywords: Electrodeionization, CEDI, ultrapure water, thick cell, layered bed, silica
Abstract: A new continuous electrodeionization (CEDI) module design employs advances such as O-ring seals, layered resin
beds, and resin-filled reject compartments to prevent external leaking, reduce electrical resistance and simplify system
design. This report describes a system operating at a power plant for about two years in place of a counter-current
demineralizer.
The original boiler makeup water system for the plant Table 2. RO Permeate Analysis, 05 Feb 2001
consisted of weak acid cation resin, a forced-draft Specific conductivity 1.5 µS/cm
decarbonator, strong acid cation resin, weak base anion Calcium < 0.01 ppm as CaCO3
resin and strong-base anion resin (all with cocurrent Magnesium < 0.01 ppm as CaCO3
regeneration). Demineralized water was fed to a 150,000 Sodium 1.5 ppm as CaCO3
gallon DI water storage tank, from which it was fed to the Bicarbonate 1.0 ppm as CaCO3
boilers. Raw feed water for the DI water system is taken Chloride 0.12 ppm as CaCO3
from a private well, and has the typical quality shown in Nitrate 0.3 ppm as CaCO3
Table 1. Sulfate 0.01 ppm as CaCO3
Silica 0.050 ppm as SiO2
Table 1. Raw Water Analysis, 05 Feb 2001 TOC 0.21 ppm as C
Specific conductivity 597 µS/cm
Turbidity < 0.1 NTU
Calcium 185 ppm as CaCO3
PH 7.47
Magnesium 154 ppm as CaCO3
Free CO2 0.1 ppm as CaCO3
Sodium 15 ppm as CaCO3
Potassium 1.5 ppm as CaCO3 While the countercurrent demineralizer system met the
Bicarbonate 294 ppm as CaCO3 plant’s requirements for deionized water quality and
Chloride 23 ppm as CaCO3 quantity, there were some maintenance issues, such as
Nitrate 9 ppm as CaCO3 difficulty getting replacement parts for the European-built
Sulfate 21 ppm as CaCO3 packaged system, and the inability to change the ion
Silica 19 ppm as SiO2 exchange resin on-site. Therefore, in 2001 the plant
TOC 2 ppm as C decided to replace the three-bed deionizer with a
Turbidity < 0.1 NTU continuous electrodeionization (CEDI) system. This
PH 7.46 provided the additional benefit of eliminating the
Free CO2 23 ppm as CaCO3 regenerant chemicals and the need for neutralization of
waste regenerant. Figure 1 shows the evolution of the
In the 1970’s, Nelson Dewey became one of the earliest boiler makeup DI water system at the Nelson Dewey
power plants to employ reverse osmosis (RO) as generating station.
pretreatment to a demineralizer in order to reduce
chemical consumption, well before this became
Figure 1 Evolution of the boiler makeup water deionization system at the Nelson Dewey Generating Station
To 150 kgal
DI tank
Cation Decarbonator Cation Anion Anion
Acid SHMP
Cation Decarbonator Cation Anion Anion
PolyamideRO
Well
water
UV
2500 gal
RO tank
2500 gal
DI Tank
To 150 kgal
DI tank
Cation
Anion Cation
Polisher
FAL FAL
1 1
FE PI PI FE AE
1 1 3 1 1
CEDI feed
(RO permeate)
HV1 Diluting
HV4
SV1 Compartments
SV2
Product
PI PI
2 4
Concentrating
compartments
HV2 HV3
0.1 10
0.09 8
CEDI product water
CEDI feed water
Product, µS/cm
0.08 6
Feed, µS/cm
0.07 4
0.06 2
0.05 0
10/27/01 01/25/02 04/25/02 07/24/02 10/22/02 01/20/03 04/20/03 07/19/03
Date
Figure 6 - CEDI Product Pressure Drop
100 50
80 40
60 30
gpm
psid
40 20
20 10
0 0
10/27/01 01/25/02 04/25/02 07/24/02 10/22/02 01/20/03 04/20/03 07/19/03
Date
100 50
80 40
60 30
Reject pressure drop
gpm
psid
20 10
0 0
10/27/01 01/25/02 04/25/02 07/24/02 10/22/02 01/20/03 04/20/03 07/19/03
Date
Figure 8 - CEDI Electrical Resistance
75 50
60 40
45 30
Degrees F
Ohms
30 20
15 10
0 0
10/27/01 01/25/02 04/25/02 07/24/02 10/22/02 01/20/03 04/20/03 07/19/03
Date
CONCLUSIONS REFERENCES
The CEDI system at the Nelson Dewey Generating (1) Ganzi, G.C., Y. Egozy, A.J. Giuffrida, and A.D.
Station has operated trouble-free for almost two years Jha, High Purity Water by Electrodeionization:
with minimal maintenance. The use of “all-resin-filled” Performance of the Ionpure (tm) Continuous Deionization
CEDI module construction has allowed operation without System, Ultrapure Water, Vol. 4, No. 3, pp. 43-50 (1987).
concentrate recirculation or concentrate salt injection.
The module design with O-ring seals and encapsulated tie (2) Henley, M., Ion Exchange Markets, Part 1 – The
bars has avoided any module leaking or arcing. Changing Role for Ion Exchange Water Treatment,
Ultrapure Water, Vol. 19, No. 6, pp. 13-16 (July/August
Some other factors that have contributed to system 2002).
performance and reliability are the use of softening ahead
of the RO system; the low TOC of the raw feed (well) (3) Gifford, J and Atnoor, D. An Innovative
water, and the use of caustic addition pre-RO to reduce Approach to Continuous Electrodeionization Module and
the CO2 load on the CEDI system. System Design for Power Applications, International
Water Conference, October 2000.