Technical Specifications (Cont’d)

INPUTS CONTROL ENVIRONMENTAL


PHASE CURRENT INPUT UNDERVOLTAGE RESTORATION Operating temperature range: -40° C to +60° C
Source CT: 1 to 50000 A primary / 1 or 5 A Initiated by: Trip from undervoltage 1, 2, 3 Ambient storage temperature: -40° C to +85° C
secondary or 4 Ambient shipping temperature: -40° C to +85° C
Relay input: 1 A or 5 A (specified when ordering) Minimum voltage level: 0.00 to 1.25 x VT in steps of Humidity: Operating up to 95%
Burden: Less than 0.2 VA at 1 or 5 A 0.01 (non condensing) @ 55C
Conversion range: 0.01 to 20 x CT (fundamental Time delay: 0.1 to 100.0 in steps of 0.1 s Pollution degree: 2
frequency only) Incomplete sequence time:1 to 10000 in steps of 1 min. IP rating: IP40 (front), IP20 (back)
Accuracy: at <2 x CT: ±0.5% of 2 x CT Phases: Any one/any two/all three
at >2 x CT: ±1% of 20 x CT (programmable) phases have
to operate for output APPROVALS TESTS
Overload withstand:
1 second @ 80 times rated current Level accuracy: Per voltage input cULus: UL508, UL1058, C22.2.No 14
continuous @ 3 times rated current Timing accuracy: ±100 ms : EN60255-5, EN50263
Calculated neutral current errors: 3 x phase inputs UNDERFREQUENCY RESTORATION
GROUND CURRENT INPUT Initiated by: Trip from underfrequency PRODUCTION TESTS
Source CT: 1 to 50000 A primary / 1 or 5 A 1 or 2 Thermal cycling: Operational test at ambi-
secondary Minimum voltage level: 0.00 to 1.25 x VT in steps ent, reducing to-40° C and then
Relay input: 1 A or 5 A (specified when ordering) of 0.01 increasing to 60° C
Burden: Less than 0.2 VA at 1 or 5 A Minimum frequency level: 20.00 to 60.00 in steps of Dielectric strength: On CT inputs, VT inputs, control power
Conversion range: 0.01 to 20 x CT (fundamental 0.01 Hz inputs, switch inputs, coil supervision
frequency only) Time delay: 0.1 to 100.0 in steps of 0.1 s outputs, and relay outputs (2 kVac for
Accuracy: at <2 x CT: ±0.5% of 2 x CT Incomplete sequence time:1 to 10000 in steps of 1 min. 1‑minute) to safety ground.
at >2 x CT: ±1% of 20 x CT Level accuracy: Per voltage and frequency
Overload withstand: input TYPE TESTS
1 second @ 80 times rated current Timing accuracy: ±100 ms Dielectric voltage EN60255-5
continuous @ 3 times rated current withstand:
SENSITIVE GROUND CURRENT INPUT *Specifications subject to change without notice. Impulse voltage EN60255-5
Source CT: 1 to 50000 A primary / 1 or 5 A withstand:
secondary OUTPUTS Insulation resistance: EN60255-5
Relay input: 1 A or 5 A (specified when ordering) ANALOG OUTPUTS Damped Oscillatory: IEC 61000-4-18 / IEC 60255-22-1
Burden: Less than 0.2 VA at 1 or 5 A Type: Active Electrostatic EN61000-4-2 / IEC 60255-22-2
Conversion range: 0.005 to 1.000 x CT (fundamental Outputs: 8 channels; specify one of the Discharge:
frequency only) following output ranges when ordering: RF immunity: EN61000-4-3 / IEC 60255-22-3
Accuracy: at <0.1 x CT: ±0.2% of 1 x CT Output range Maximum load Fast Transient EN61000-4-4 / IEC 60255-22-4
at >
­ 0.1 x CT: ±1% of 1 x CT 0 – 1 mA 12 kV Disturbance:
Overload withstand: 0 – 5 mA 2.4 kV Surge Immunity: EN61000-4-5 / IEC 60255-22-5
1 second @ 80 times rated current 0 – 10 mA 1.2 kV Conducted RF EN61000-4-6 / IEC 60255-22-6
continuous @ 3 times rated current 4 – 20 mA 600V Immunity:
BUS AND LINE VOLTAGE INPUTS Isolation: Fully isolated Radiated & CISPR11 / CISPR22 / IEC 60255-25
Source VT: 0.12 to 600 kV / 50 to 240 V Accuracy: ±1% of full scale Conducted
Source VT ratio: 1 to 5000 in steps of 0.1 Response time: 100% indication in less than 3 power Emissions:
Relay input: 50 V to 240 V phase-neutral system cycles (50 ms @ 60 Hz) Sinusoidal Vibration: IEC 60255-21-1
Burden: Less than 0.025 VA at 120 V Shock & Bump: IEC 60255-21-2
SOLID STATE TRIP
or >576 K Make and carry: 15 A @ 250 VDC for 500 ms Siesmic: IEC 60255-21-3
Max continuous: 273 V phase-neutral (full scale) CT Output relays: Power magnetic IEC 61000-4-8
(fundamental frequency only) Configuration: 1 TRIP: Form A Immunity:
Accuracy (0° – 40° C): 2 CLOSE: Form A Pulse Magnetic IEC 61000-4-9
±0.205% of full scale (10 to 130 V) 3 – 7 AUXILIARY: Form C Immunity:
±0.8% of full scale (130 to 273 V) 8 SELF-TEST WARNING: Voltage Dip & IEC 61000-4-11
(for open delta, the calculated phase Form C interruption:
has errors 2 times those shown Contact material: Silver alloy Ingress Protection: IEC 60529
above) Environmental IEC 60068-2-1
LOGIC INPUTS COMMUNICATIONS (Cold):
Inputs: 14 contact and / or virtual, Serial Ports: 300 – 19,200 baud, programmable Environmental (Dry IEC 60068-2-2
6 virtual only parity, heat):
(functions assigned to logic inputs) ModBus® RTU or DNP 3.0 protocol Relative Humidity IEC 60068-2-30
Dry contacts: 1000 maximum ON resistance Ethernet Port: 10BaseT, RJ45 Connector, ModBus® Cyclic:
(32 VDC @ 2 mA provided by relay) RTU over TCP/IP EFT: IEEE / ANSI C37.90.1
Wet contacts: 30 to 300 VDC @ 2.0 mA Damped Oscillatrory: IEEE / ANSI C37.90.1
(external DC voltage only) RF Immunity: IEEE/ANSIC37.90.2
POWER SUPPLY ESD: IEEE/ANSIC37.90.3
ANALOG INPUT CONTROL POWER
Current input: 0 – 1 mA, 0 – 5 mA, 0 – 10 mA, Safety: UL508 / UL C22.2-14 / UL1053
Options: LO/HI (specified when ordering)
0 – 20 mA, or 4 – 20 mA LO range: DC = 20 to 60 V
(programmable) AC = 20 to 48 V @ 48 – 62 Hz
Input impedance: 375 ±10% HI range: DC = 88 to 300 V
Conversion range: 0 to 21 mA AC = 70 to 265 V @ 48 – 62Hz
Accuracy: ±1% of full scale Power: 25 VA nominal, 35 VA maximum
TRIP AND CLOSE COIL MONITORING INPUTS Voltage loss hold-up time: 30 ms
Acceptable voltage range: 20 to 250 VDC
Trickle current: 2 mA to 5 mA
IRIG-B INPUT
Amplitude-modulated: 2.5 to 6 Vp-p @ 3:1
signal ratio
DC shift: TTL

Please refer to Multilin 750/760 Feeder Protection System Instruction Manual for complete technical
sepcifications

GEGridSolutions.com 9
Ordering
750/760 * * * * * * * * Description
Phase Current Inputs P1 1 A phase current inputs
P5 5 A phase current inputs
Ground Current Inputs G1 1 A zero sequence current inputs
G5 5 A zero sequence current inputs
Sensitive Ground Current Inputs S1 1 A sensitive ground current input
S5 5 A sensitive ground current input
Power Supply Options LO 20 – 60 VDC, 20 – 48 VAC @ 48 – 62 Hz
HI 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz
Analog Outputs A1 Eight 0 – 1 mA analog outputs
A5 Eight 0 – 5 mA analog outputs
A10 Eight 0 – 10 mA analog outputs
A20 Eight 4 – 20 mA analog outputs
Breaker Status LED R Red breaker closed LED
G Green breaker closed LED
Enhancements E Enhanced display, larger LCD, improved keypad
T Enhanced display with Ethernet 10BaseT option
Environmental Protection H Harsh Chemical Environment Option

GEGridSolutions.com
IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered
trademark of the Institute of Electrical Electronics Engineers, Inc. Modbus is a registered trademark of
Schneider Automation. NERC is a registered trademark of North American Electric Reliability Council.
NIST is a registered trademark of the National Institute of Standards and Technology.
GE, the GE monogram, Multilin, FlexLogic, EnerVista and CyberSentry are trademarks of General Electric
Company.

GE reserves the right to make changes to specifications of products described at any time without notice
and without obligation to notify any person of such changes.

Copyright 2015, General Electric Company. All Rights Reserved. GEA-31955-(E)