Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

EMR 2 DIAGNOSTIC FAULT CODES

DEUTZ Blink SPN FMI JLG DESCRIPTION TEST


1 211 190 8 NA speed sensor 1 Check wiring, sensor airgap,
2 212 190 8 NA speed sensor 2 sensor contamination or damage,
3 213 84 8 NA speed sensor faulty sensor
Check for wrong dataset, fuel
4 214 190 0 190:8 overspeed shutdown system fault
5 215 91 2 NA set point 1 foot pedal circuit
6 216 201 2 NA setpoint 2 hand throttle circuit
7 217 102 2 102:2 boost pressure circuit
Check wiring, sensor, and error
8 218 100 2 110:2 oil pressure circuit
limits in dataset
9 219 110 2 NA coolant temperature circuit
10 220 105 2 NA boost temperature circuit
11 221 174 2 NA fuel temperature circuit
30 231 100 1 100:1 oil pressure low
Check for fault in corresponding
31 232 110 0 110:0 coolant temperature high
engine system, wiring, and dataset
32 233 105 0 NA boost temperature high
error limits
34 235 111 1 NA coolant level low
Check for wrong dataset, fuel
35 236 190 14 702:14 overspeed shutdown system fault
Check wiring, sensor, and dataset
36 237 174 0 NA fuel temperature high error limits
40 231 100 1 100:1 oil presure shutdown
Check for fault in corresponding
41 232 110 0 110:0 coolant temperature shutdown
engine system, wiring, and dataset
42 233 105 0 NA boost temperature shutdown
error limits
44 235 111 1 NA coolant level shutdown
Check wiring between ECU and
50 251 24 12 536:12 rack position circuit shutdown
actuator, actuator contamination
52 251 24 13 536:13 rack position circuit shutdown (1012, 1015), faulty actuator
Check for fuel system fault, wiring,
53 251 23 7 535:7 control rack sticking shutdown and actuator
59 252 23 13 NA pump auto calibration inop. NA
60 261 51 2 NA shutdown solenoid circuit
Check corresponding wiring,
62 262 60 2 NA ECU pin M7 circuit
solenoid or device, and dataset
63 261 51 6 NA shutdown solenoid circuit
67 262 91 11 91:11 setpoint 1 error NA
68 262 898 2 898:2 CAN setpoint 1 error NA
70 271 231 12 743:12 CAN controller fault
Check bus cables, terminating
71 271 231 9 743:9 CAN transmission error
resistor, and ECU
74 271 231 14 743:14 CAN circuit fault
76 281 253 12 765:12 EEPROM error
77 281 240 12 752:12 ECU memory error
78 281 254 2 766:2 ECU memory error
Actuator power supply out of
80 291 254 2 766:2 range Cycle ignition / power to ECU and
83 282 254 2 NA 5V reference 1 out of range check if fault is passive. If fault
84 282 254 2 NA 5V reference 2 out of range remains active, contact DEUTZ.
85 282 254 2 766:2 5V reference 4 out of range
86 292 171 12 171:12 ECU temperature high
ECU barometric sensor out of
87 292 108 12 NA range
90 253 2 765:2 ECU memory error Cycle the ignition / power to ECU
and check if fault is passive. If fault
93 240 2 752:2 ECU internal error remains active, verify dataset and
contact DEUTZ
94 254 2 766:2 ECU internal error

You might also like