Light Indicator

HydroPure™
Lead Acid Deionizer System (PS-300)
Nickel Alkaline Deionizer System (PS-310)
Replacement Cartridge (PS-600)
Installation Instructions
Green flashing light = Ready to Consistent Red flashing No light = Power problem. Backplate (A)
dispense battery water. light = Replace cartridge. Check and/or replace batteries.

Cartridge (B)

Strap (C)
Inlet Hose (D)
Ensure water supply is turned off Remove the 4 screws from the
and remove cartridge. battery case.

Purity Light Battery (E)


Purity Light (F)
PS-191 for PS-300
PS-161DC for PS-310
HydroPure Deionizer cartridges Transfer the 2 male quick-connect Remove the cover and replace
have a one year shelf life from fittings to the new cartridge then the battery*.
date of manufacture. safely dispose of the old cartridge. Output Hose (G)

Flow Restrictor (H)


*Please note that when the batteries are
removed or changed a light function test is Install the new cartridge and allow Replace the 4 screws in the
performed. The sequence of illumination from 5-10 gallons of water to flow battery casing.
is: (a) Red light single pulse, (b) Green through the cartridge, using either
light single pulse, (c) Red and Green lights the Flow Restrictor or watering gun.
together single pulse, (d) Return to normal This activates the resin that deionizes the
flashing mode. water. The Purity Light will begin to flash This pack contains: Required:
green when enough water has passed
through the cartridge. 1 x Backplate (A) 1 x Battery (E)
1 x Cartridge (B) 1 x Purity Light (F)
Philadelphia Scientific LLC 1 x Strap (C) 1 x Output Hose (G)
207 Progress Drive Montgomeryville, PA 18936 1 x Inlet Hose (D) 1 x Flow Restrictor (H)
P: 215.616.0390 F: 215.616.0500 www.phlsci.com

© 2016 Philadelphia Scientific LLC All Rights Reserved. Philadelphia Scientific and the PS
PAK939 logo are registered trademarks of Philadelphia Scientific LLC. HydroPure is a trademark of 1
02/2016 Philadelphia Scientific LLC E&O.E.
HEALTH AND SAFETY PRECAUTIONS
Batteries contain sulphuric acid, always wear approved protective
clothing (gloves, goggles and apron).

Installation

Using the quick-connect fitting Attach the blue Output Hose Attach either the WateringGun
attach the purity light to the to the purity light by using the or Flow Restrictor to the free
bottom of the cartridge. threaded connection. end of the blue hose.

Initial Start-Up Operation


Remove cartridge from the Securely attach the mounting Remove the red caps from the
mounting plate to ease installation. plate vertically to the wall with cartridge and thread on the 2
the strap fitting at eye-level. male quick-connect fittings.

5-10
US Gal
<80psi
(5.5bar)

Turn on the mains water supply. Pass19 - 38 Litres (5 - 10 US When the Purity Light turns green
Gallons) of water through the the system is ready for use.
system into a bucket.

Re-attach the cartridge to the Connect the fixed end of the Connect the free end of the black
mounting plate using the strap.
Ensure arrows are pointing up.
black inlet hose to the cartridge. inlet hose to the water supply. Normal Operation

Turn on the mains water supply Ensure water is flowing through Once finished turn of the water
Loosen 4 screws of battery Remove backing tape from the Attach the battery case firmly before use. the system and use as required. supply and replace the hose on
case and pull out tape to velcro strips on the back of the to the velcro strips on the the hooks provided.
activate. Re-tighten screws. battery case. backplate.
2 3
HEALTH AND SAFETY PRECAUTIONS
Batteries contain sulphuric acid, always wear approved protective
clothing (gloves, goggles and apron).

Installation

Using the quick-connect fitting Attach the blue Output Hose Attach either the WateringGun
attach the purity light to the to the purity light by using the or Flow Restrictor to the free
bottom of the cartridge. threaded connection. end of the blue hose.

Initial Start-Up Operation


Remove cartridge from the Securely attach the mounting Remove the red caps from the
mounting plate to ease installation. plate vertically to the wall with cartridge and thread on the 2
the strap fitting at eye-level. male quick-connect fittings.

5-10
US Gal
<80psi
(5.5bar)

Turn on the mains water supply. Pass19 - 38 Litres (5 - 10 US When the Purity Light turns green
Gallons) of water through the the system is ready for use.
system into a bucket.

Re-attach the cartridge to the Connect the fixed end of the Connect the free end of the black
mounting plate using the strap.
Ensure arrows are pointing up.
black inlet hose to the cartridge. inlet hose to the water supply. Normal Operation

Turn on the mains water supply Ensure water is flowing through Once finished turn of the water
Loosen 4 screws of battery Remove backing tape from the Attach the battery case firmly before use. the system and use as required. supply and replace the hose on
case and pull out tape to velcro strips on the back of the to the velcro strips on the the hooks provided.
activate. Re-tighten screws. battery case. backplate.
2 3
Light Indicator

Green flashing light = Ready to Consistent Red flashing No light = Power problem.
dispense battery water. light = Replace cartridge. Check and/or replace batteries.

Ensure water supply is turned off Remove the 4 screws from the
and remove cartridge. battery case.

HydroPure Deionizer Transfer the 2 male quick-connect Remove the cover and replace
cartridges have a five year fittings to the new cartridge then the battery*.
shelf life from date of safely dispose of the old cartridge.
manufacture.

*Please note that when the batteries are


removed or changed a light function test is Install the new cartridge and allow Replace the 4 screws in the
performed. The sequence of illumination from 5-10 gallons of water to flow battery casing.
is: (a) Red light single pulse, (b) Green through the cartridge, using either
light single pulse, (c) Red and Green lights the Flow Restrictor or watering gun.
together single pulse, (d) Return to normal This activates the resin that deionizes the
flashing mode. water. The Purity Light will begin to flash
green when enough water has passed
through the cartridge.

Philadelphia Scientific LLC


207 Progress Drive Montgomeryville, PA 18936
P: 215.616.0390 F: 215.616.0500 www.phlsci.com

© 2019 Philadelphia Scientific LLC All Rights Reserved. Philadelphia Scientific and the PS
PAK939 logo are registered trademarks of Philadelphia Scientific LLC. HydroPure is a trademark of 1
04/2019 Philadelphia Scientific LLC E&O.E.