Ductable Air-to-Water Heat Pumps with

Integrated Hydronic Module

AQUASNAP

Carrier is participating in
the Eurovent Certification
Programme. Products are
as listed in the Eurovent
Directory of Certified
Products.

30RYH “A”
Nominal cooling capacity 18-77 kW
Nominal heating capacity 18-78 kW

The 30RYH Aquasnap air-to-water heat pumps are available pressure, expansion tank, water flow switch,
designed for indoor installation. A fan with available pres- safety valve, pressure gauges, and purge valve. A throttle
sure permits connection of the suction and discharge lines valve allows adjustment of the water flow in accordance
to a duct system that can be equipped with sound attenua- with the characteristics of the installation. As an option
tion. The 30RYH units incorporate the latest technological Aquasnap is available without hydronic module.
innovations: ecological refrigerant HFC-407C, scroll com- ■ Low-volume water loop: an auto-adaptive algorithm
pressors and auto-adaptive microprocessor control. The controls the water temperature and eliminates any risk of
refrigerant circuit with its patented receiver/heat exchan- excessive compressor cycling. In the majority of comfort
ger, and the auto-adaptive Pro-Dialog control system air conditioning applications a buffer tank is unnecessary.
guarantee reliable and economical operation in all climates The low water volume reduces the energy consumption
from -10°C to 45°C. Aquasnap includes a complete during changeover from heating to cooling during in-
hydronic module as standard, limiting the installation to between seasons.
straightforward operations like connection of the power ■ Ecological refrigerant HFC-407C: no effect on the ozone
supply and the water supply and return piping. layer, replaces R-22 in air conditioning applications with
small and medium capacities. Extensively tested by Carrier
Features for several years, it offers the same performance and
■ Quiet axial fan with available pressure. Unlike a centrifugal reliability guarantees as R-22.
fan this type of fan does not require any adjustment at ■ The receiver/heat exchanger (Carrier patent) enhances
installation, as the flow rate only slightly depends on the reliability and performance of the 30RYH heat pump. In the
pressure losses in the duct system. As the fan is directly heating mode the refrigerant is condensed in the receiver at
mounted on the motor, there is no belt to adjust and replace. the plate heat exchanger outlet. This device compensates
At part load or low outdoor temperatures the fan for large differences in volume between the coil and the
automatically switches to the low speed. water heat exchanger (plate heat exchanger). It ensures an
■ Integrated hydronic module for fast installation, ideal refrigerant charge in heating and cooling mode and
incorporating all components necessary for the operation of perfect control of subcooling or superheating. Compressor
the system: removable screen filter, water pump with high life is increased (no risk of refrigerant migration into the
compressor), and the use of the heat exchangers is ■ To reduce power consumption, PRO-DIALOG Plus
maximised. automatically resets the leaving water temperature set point
■ Defrost is optimised by the auto-adaptive algorithm. This in accordance with the outdoor air temperature or uses a
and the new coil design reduce the defrost cycle duration by second set point (example: room unoccupied) and ensures
an average of 50%. For increased safety an electric heater automatic heating/cooling changeover.
prevents accumulation of ice on the air heat exchanger ■ The system also controls the start-up of a boiler relay or
base. manages a supplementary electric heater (accessory).
■ Quiet, vibration-free scroll compressors, durable and
maintenance-free. The use of several compressors per Clear and easy-to-use control system
circuit (from size 30RYH 050) reduces the start-up current ■ The operator interface is clear and user-friendly: LEDs and
and the power consumption at part load. two numerical displays ensure immediate verification of all
■ The refrigerant circuit is completely leak-proof for life. All unit operating data.
pipes and refrigeration components are welded. Pressure ■ Buttons conveniently positioned on a synoptic heat pump
sensors, mounted directly on the pipes, take the place of the diagram offer immediate display of the operating para-
pressure switches and their capillary tubes, a source of meters: temperatures, pressures, set point, run times etc.
leaks in the past. ■ 10 menus offer direct access to all machine controls,
■ Electrical connections are simplified, and the standard including a history of possible faults, for rapid and
Aquasnap equipment includes a main disconnect switch, complete heat pump fault diagnosis.
and a single entry point of the three-phase without neutral
power supply to the whole unit. Extended communications capabilities
■ Large removable panels and the hinged door of the control ■ PRO-DIALOG Plus allows remote control. Volt-free
box ensure perfect accessibility and permit easy access to contacts regulate: start/stop, cooling/heating mode
all components. selection, power demand limit or selection of the second set
■ The electric resistance heater control module (accessory) point. The system permits remote signalling of any possible
permits control of up to four stages of electric heat for anomaly for each refrigerant circuit.
supplementary heating at low outdoor temperatures. ■ The “CCN Clock Board” option/accessory ensures the time
schedule programming of the heat pump:
PRO-DIALOG Plus control - start/stop,
PRO-DIALOG Plus is an advanced numeric control sys- - operation at the second set point (e.g. unoccupied mode),
tem that combines complex intelligence with great operat- - low-speed fan operation (e.g. during the night).
ing simplicity. PRO-DIALOG Plus constantly monitors all This option/accessory also controls the operation of two
machine parameters, optimising the operation of compres- units in parallel and offers a serial RS 485 communication
sors, fan, cycle reversing valve and water pump. port.
A powerful control system
■ The auto-adaptive Pro-Dialog Plus control guarantees total
protection of the compressors. The system permanently
checks the operating parameters and responds to avoid
excessive cycling and maintain the ideal operating range for
the compressor (temperatures and pressures out of range
etc.). By taking corrective action before the fault occurs, the
auto-adaptive control frequently prevents a shutdown of the
heat pump due to a fault condition.

PRO-DIALOG Plus operator interface

2
Options and accessories
Option Accessory
Air heat exchanger anti-corrosion pre-treatment for light marine applications X
Electronic compressor starter for reduction of start-up current (30RYH 040-080) X
Unit without hydronic module X
Hydronic module with dual pump (30RYH 040-080) X
"CCN Clock Board" time scheduling and communications board X X
Time scheduling board and Aquasmart system communications board X
Supplementary electric resistance heater control board (3 stages + 1 emergency stage) X
Unit support with condensate recovery pan X
Suction air filter, mounted on rails X
Outside installation (30RYH 040-080) X
RS 485 communications interface with open JBus protocol X

21

20
4
2

8
3
1

24
9 Legend

14 Components of unit and hydronic module


1 Victaulic screen filter
2 Expansion tank
16 22 3 Safety valve
4 Available pressure pump
23 5 Purge valve and pressure tap (see Installation Manuel)
6 Pressure gauges to measure the plate heat exchanger
Hydronic module (040 to 080) pressure drop (to be isolated with valve No. 5 if not used)
7 System air vent
8 Flow switch
9 Flow control valve
10 Plate heat exchanger
11 Evaporator defrost heater

2 Installation components
12 17 12 Air vent
14 15 1 13 Thermometer sleeve
10 14 Flexible connection
4
15 Check valve
13 3 16 System water drain plug (on connection pipe supplied in
the unit)
17 Pressure gauge
18 Freeze-up protection bypass valve (when valves No. 15
5
are closed during winter)
19 Charge valve
18 6 11 20 Plate heat exchanger outlet
21 Plate heat exchanger inlet
22 Water inlet
7 23 Water outlet
17 5 24 Customer connection sleeves for welded or screw
connection (supplied)
13 14 15 9 8

------ Hydronic module (units with hydronic module)


19
Note: Units without hydronic module (option) are equipped with
16 a flow switch and an internal piping heater.
Typical hydronic circuit diagram (040 to 080)

3
Physical data
30RYH 017 021 026 033 040 050 060 070 080
Net nominal cooling capacity, single pump* kW 17.8 22.5 24.2 31.4 37.7 44.8 57.0 65.0 77.0
Net nominal cooling capacity, dual pump* kW - - - - 36.5 43.7 56.0 64.0 76.0
Net nominal heating capacity, single pump** kW 18.3 22.1 25.5 34.5 37.2 48.2 55.0 62.0 77.0
Net nominal heating capacity, dual pump** kW - - - - 38.3 49.3 56.0 63.0 78.0
Operating weight
with hydronic module, single pump kg 410 440 460 475 550 612 627 688 736
with hydronic module, dual pump kg - - - - 630 692 707 768 813
without hydronic module kg 385 415 435 450 526 588 603 664 710
Refrigerant charge R-407C kg 6.4 6.6 7.4 8.6 10.3 11.4 12.5 13.3 17.3
Compressors Hermetic scroll compressors, 48.3 r/s
Quantity 1 1 1 1 1 2 2 2 2
No. of capacity steps 1 1 1 1 1 2 2 2 2
Minimum capacity % 100 100 100 100 100 46 42 50 50
Control type PRO-DIALOG Plus
Air heat exchanger Grooved copper tubes, aluminium fins
Fan Axial with available pressure
Quantity 1 1 1 1 1 1 1 1 1
Available static pressure Pa 100 100 100 100 150 150 150 150 150
Total air flow (high speed) l/s 1940 1940 1940 2500 3890 3890 4720 5830 5830
Speed (high/low speed) r/s 24/12 24/12 24/12 24/12 24/12 24/12 24/12 24/12 24/12
Water heat exchanger Direct-expansion welded plate heat exchanger
Water volume l 1.6 2.0 2.3 3.0 3.6 4.6 5.9 6.5 7.6
Max. water-side operating pressure
Option without hydronic module kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000
Unit with hydronic module kPa 250 250 250 250 300 300 300 300 300
Hydronic module Pump, safety valve, expansion tank, flow switch and flow control throttle valve
Screen filter, pressure gauge, purge valves Victaulic screen filter, manometer, purge valves (water
and air)
Pump (centrifugal) Single multicell pump, 48.3 r/s Single composite monocell pump, 48.3 r/s
Quantity 1 1 1 1 1 1 1 1 1
Expansion tank volume l 8 8 8 8 12 12 12 12 12
Water connections
(with and without hydronic module) Threaded male gas connections Victaulic (sleeves for welding or screw connections
supplied)
Diameter in 1-1/4 1-1/4 1-1/4 1-1/4 2 2 2 2 2
Outside tube diameter in 1-1/4 1-1/4 1-1/4 1-1/4 2 2 2 2 2
mm 42.4 42.4 42.4 42.4 60.3 60.3 60.3 60.3 60.3
* Standard Eurovent conditions: water heat exchanger entering/leaving temperature 12°C/7°C, outdoor air temperature 35°C.
Net nominal cooling capacity based on Eurovent conditions = gross cooling capacity plus the capacity corresponding to the available pressure (flow x pressure/0.3).
** Standard Eurovent conditions: air heat exchanger entering/leaving temperature 40°C/45°C, outdoor air dry bulb temperature 7°C with 87% relative humidity.
Net nominal heating capacity based on Eurovent conditions = gross heating capacity minus the capacity corresponding to the available pressure (flow x pressure/0.3).

Sound levels
30RYH 017 021 026 033 040 050 060 070 080
Sound power, dB(A) 10-12 W 82 83 83 85 91 91 89 91 91
Sound power, dB(A) 10-12 W,
low-speed fans 69 77 77 79 81 80 82 83 84

Note:
According to Eurovent 8/1 (derived from ISO standard 3744 or ISO 9614-1).

4
Electrical data
30RYH 017 021 026 033 040 050 060 070 080
Power circuit
Nominal power supply V-ph-Hz 400-3-50
Voltage range V 360-440
Control circuit supply The control circuit is supplied via the unit-mounted transformer
Maximum unit power input* kW 9.78 12.05 13.75 17.35 21 25.3 31.1 36.8 42.9
Nominal unit current draw** A 15.1 17.8 19.9 26.3 30.9 36.5 46.8 56.2 62.5
Maximum unit current draw*** A 17.2 21.0 23.7 29.9 35.9 43.5 53.9 63.4 72.4
Maximum start-up current
standard unit† 89.8 133.8 133.8 139.4 181.4 153.6 163.4 172.9 217.9
with electronic starter option‡ A - - - - 120.1 108.1 116.2 125.7 156.7
* Power input of the compressor(s) + fan + pump at maximum unit operating conditions: entering/leaving water temperature = 15°C/10°C and maximum air entering temperature of 45°C ± 1 K
depending on the unit, and 400 V nominal voltage (values given on the unit name plate).
** Nominal unit current draw at standard Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outdoor air temperature 35°C. The current values are given at 400 V
nominal voltage (values given on the unit name plate).
*** Maximum unit operating current at maximum unit power input and 400 V nominal voltage (values given on the unit name plate).
† Maximum instantaneous starting current at 400 V nominal voltage and with compressor in across-the-line-start (maximum operating current of the smallest compressor(s) + fan current +
pump current + locked rotor current of the largest compressor).
‡ Maximum instantaneous starting current at 400 V nominal voltage and with compressor with electronic starter (maximum operating current of the smallest compressor(s) + fan current + pump
current + reduced start-up current of the largest compressor).

Electrical data notes:


• 30RYH units have a single power connection point. b. 30RYH 040-080 – outdoor installation
• The control box includes the following standard features: Environment* - Environment as classified in EN 60721 (corresponds to
- starter and motor protection devices for each compressor, the fan, the IEC 60721):
optional pump - outdoor installation*
- the control devices - ambient temperature range: -10°C to +46°C, class 4K3**
• Field connections: - altitude: ≤ 2000 m
All connections to the system and the electrical installations must be in full - presence of hard solids, class 4S2** (no significant dust present)
accordance with all applicable local codes. - presence of corrosive and polluting substances, class 4C2 (negligible)
• The Carrier 30RYH units are designed and built to ensure conformance with - vibration and shock, class 4M2
these codes. The recommendations of European standard EN 60204-1 Competence of personnel, class BA4** (personnel trained according to
(corresponds to IEC 60204-1) (machine safety - electrical machine IEC 60364)
components - part 1: general regulations) are specifically taken into account, 2. Power supply frequency variation: ± 2 Hz.
when designing the electrical equipment. 3. The neutral (N) conductor must not be connected directly to the unit (if
necessary use transformers)
NOTES: 4. Over-current protection of the power supply conductors is not provided with the
• Generally the recommendations of IEC 60364 are accepted as compliance unit.
with the requirements of the installation directives. Conformance with EN 5. The factory-installed disconnect switches/circuit breakers are of a type that is
60204 is the best means of ensuring compliance with the Machines Directive suitable to interrupt the power in accordance with EN60947-3 (corresponds to
§ 1.5.1. IEC 60947-3).
• Annex B of EN 60204-1 describes the electrical characteristics used for the 6. The units are designed for connection to TN networks (IEC 60364). For IT
operation of the machines. networks the earth connection must not be at the network earth. Provide a local
earth, consult competent local organisations to complete the electrical
1. The operating environment for the 30RYH units is specified below: installation.
a. 30RYH 017-080 – indoor installation
Environment* - Environment as classified in EN 60634 § 3: NOTE:
- ambient temperature range: +5°C to +40°C, class AA4 If particular aspects of an actual installation do not conform to the
- humidity range (non condensible*): conditions described above, or if there are other conditions which should
50% rh at 40°C be considered, always contact your local Carrier representative.
90% rh at 20°C
- altitude: ≤ 2000 m * The required protection level for this class is IP21B (according to reference
- indoor installation* document IEC 60529). All 30RYH 017-080 units are protected to IP23C and
- presence of water, class AD2* (possibility of water droplets) fulfil this protection condition.
- presence of hard solids, class AE2* (no significant dust present) ** The required protection level for this class is IP43BW (according to reference
- presence of corrosive and polluting substances, class AF1 (negligible) document IEC 60529). All 30RYH 040-080 units are protected to IP45CW and
- vibration and shock, class AG2, AH2 fulfil this protection condition.
Competence of personnel, class BA4* (personnel trained according to
IEC 60364)

5
Operating limits
Operating range in cooling mode Operating range in heating mode
˚C
˚C
46 40
35
45 30
44.5
44 25

Entering air temperature


Entering air temperature

20
15
10
5
0
-5
0
-10 -10

20 25 30 35 40 45 50 ˚C
0 1 2 3 4 5 6 7 8 9 10 ˚C
Leaving water temperature Leaving water temperature

Notes:
1. Water heat exchanger ∆t = 5 K
Maximum entering air temperature, °C (cooling mode)
2. 30RYH 017-033: Install the unit in a location that is frost-free. 30RYH Air flow
30RYH 040-080: The evaporator and the hydronic module are protected against frost
down to -20°C. Minimum Nominal Maximum
3. Maximum air entering temperature at nominal static pressure of the fan. 017-026 44 46 47.5
Operating range with required anti-freeze solution and special Pro-Dialog control configu- 033 44 46 47
ration
040-050 44.5 46 47
060 44.5 46 47
Fan data 070-080 44.5 46 47
30RYH Min. available Nom. available Max. available
static pressure* static pressure static pressure
Pressure Flow Pressure Flow Pressure Flow
Performance correction factors
Pa l/s Pa l/s Pa l/s
30RYH Cooling capacity Power input
017-026 0 2500 100 1940 150 1530
Min. flow Max. flow* Min. flow Max. flow*
033 0 2920 100 2500 200 1940
017-026 0.98 1.01 1.03 0.97
040-050 0 4580 150 3890 230 3330
033 0.98 1.005 1.03 0.98
060 0 5560 150 4720 230 4030
040-050 0.985 1.005 1.02 0.98
070-080 0 6810 150 5830 230 5280
060 0.985 1.005 1.02 0.98
* Operation without duct system
070-080 0.985 1.005 1.01 0.98
* Operation without duct system
Correction factor to be added to the performances published for nominal air flow.
Heat exchanger water flow rate
30RY Min. water flow Max. water flow*, l/s Max. water flow**
l/s Single pump Dual pump l/s Heat exchanger entering water temperature
017 0.58 1.7 0 1.7 30RYH Max. temperature, Min. temperature, Max. temperature,
021 0.70 1.8 0 1.9 cooling (°C) heating (°C) heating (°C)
026 0.81 1.9 0 2.2 At start-up At shut- At start-up At shut- At start-up At shut-
033 1.10 2.0 0 3.0 down down down
040 1.20 3.5 4.4 3.7 017-080 35 60 10 3 50 60
050 1.19 4.0 5.2 4.6
060 1.46 4.4 6.0 5.8
070 1.66 4.6 6.4 6.4
080 1.92 5.5 6.8 7.3
* Maximum flow rate for an available pressure of 50 kPa (unit with hydronic module)
** Maximum flow rate for a pressure drop of 100 kPa in the plate heat exchanger (unit with-
out hydronic module)

6
Water pump: Available static pressure for water-side
installation
Single pump

300

275

250
Available static pressure, kPa

225

200

175

150

125

100
Legend
75
4 1 30 RYH 017 6 30 RYH 050
50 2 30 RYH 021 7 30 RYH 060
1 2 3 5 6 7 8 9 3 30 RYH 026 8 30 RYH 070
25 4 30 RYH 033 9 30 RYH 080
5 30 RYH 040
0 2 4 6
Water flow rate, l/s

Dual pump

225
Available static pressure, kPa

200

175

150

125

100 Legend

75 1 30 RYH 040
2 30 RYH 050
3 30 RYH 060
50 4 30 RYH 070
1 2 3 4 5
5 30 RYH 080
25
0 2 4 6 8
Water flow rate, l/s

Water loop volume


Minimum water loop volume Maximum water loop volume

Volume = CAP (kW) x N* = litres, where CAP is the nominal Units with hydronic module incorporate an expansion tank that
cooling capacity at nominal operating conditions. limits the water loop volume. The table below gives the maxi-
mum loop volume for pure water or ethylene glycol with
Air conditioning application N* various concentrations.
30RYH 017-040 3.5
30RYH 017-033 30RYH 040-80
30RYH 050-080 2.5
(in litres) (in litres)
Pure water 400 600
10% ethylene glycol 300 450
Industrial process cooling
20% ethylene glycol 250 400
30RYH 017-080 See note
35% ethylene glycol 200 300
Note
For industrial process cooling applications, where high stability of the water
temperature must be achieved, the values above must be increased.

7
Dimensions/clearances
30RYH 017-033
962
922.5
863 2058
1372

670 670

1000
1

30RYH 040-080

1128 2097
1068 2058
1372

1000

Legend:
All dimensions are given in mm.

Power supply 820

1 Recommended clearances for maintenance

1
Water inlet
820

Water outlet

Power cable entry


1000

1
Air inlet/outlet connection

NOTE:
Drawings are not contractually binding.
Before designing an installation, consult the certified
dimensional drawings, available on request.

8
Heating capacities, single pump
30RYH Entering air temperature, ˚C

-10 -5 0 7 10
LWT

CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES

˚C kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa
017 30 9.43 4.62 5.6 0.51 12 279 10.4 4.65 5.58 0.58 16 271 12.6 4.82 5.68 0.69 21 256 20.4 4.35 5.11 0.98 39 212 22.2 4.39 5.15 1.06 45 196
021 11.4 5.62 6.51 0.62 11 272 12.6 5.66 6.49 0.71 14 262 15.3 5.86 6.63 0.85 20 243 24.7 5.47 6.18 1.18 40 187 26.9 5.53 6.26 1.29 47 167
026 13.1 5.83 6.65 0.72 10 266 14.4 5.87 6.63 0.82 13 254 17.6 6.08 6.78 0.98 19 232 27.7 6.49 7.18 1.33 36 172 30.1 6.58 7.31 1.44 43 149
033 17.4 8.82 9.8 0.96 13 239 19.3 8.88 9.82 1.1 16 221 23.6 9.2 10.1 1.32 22 187 37.5 8.63 9.8 1.79 39 97 40.9 8.74 10.1 1.94 45 63
040 19.7 8.57 11.1 1.03 8 162 21.7 8.63 11.1 1.17 10 160 26.4 8.99 11.4 1.4 15 155 39.9 9.92 12.1 1.9 27 140 43.2 10.1 12.3 2.06 32 134
050 26.1 11.9 14.3 1.35 9 162 28.7 12 14.3 1.54 11 158 35 12.5 14.6 1.84 16 152 55 12.8 14.8 2.65 33 124 59 13 15 2.82 37 116
060 30.2 13.1 16.9 1.54 7 162 33.3 13.1 16.9 1.75 9 159 40.6 13.7 17.3 2.1 13 152 59 14.5 17.9 2.85 24 129 64 14.7 18.2 3.06 28 121
070 36 14.6 19.4 1.73 7 161 39.7 14.7 19.4 1.97 9 157 48.5 15.3 19.9 2.36 14 148 65 17 21.5 3.13 24 123 71 17.2 21.8 3.39 28 113
080 41.8 17.8 22.5 2.15 9 200 46.1 17.9 22.5 2.45 11 193 56 18.7 23 2.93 16 178 82 19.4 23.6 3.95 30 138 88 19.6 24 4.25 34 124
017 35 9.28 5.03 6.02 0.5 12 280 10.2 5.06 5.99 0.57 15 272 12.4 5.23 6.09 0.68 21 257 19.7 4.89 5.65 0.94 37 218 21.5 4.93 5.69 1.03 43 203
021 11.2 6.12 7.01 0.61 11 273 12.4 6.16 6.99 0.7 14 263 15.1 6.36 7.13 0.84 20 245 23.9 6.13 6.84 1.14 37 195 26.1 6.19 6.92 1.25 44 175
026 12.8 6.35 7.17 0.7 10 267 14.2 6.39 7.15 0.81 13 255 17.3 6.6 7.3 0.97 19 233 27 7.15 7.83 1.3 34 178 29.4 7.24 7.95 1.41 41 156
033 17.2 9.61 10.6 0.95 12 241 19 9.66 10.6 1.09 16 223 23.3 9.99 10.9 1.3 22 190 36.6 9.51 10.6 1.75 37 106 39.9 9.62 10.9 1.9 43 73
040 19.4 9.43 12 1.01 8 163 21.4 9.49 12 1.15 10 160 26 9.85 12.2 1.38 14 156 38.7 10.9 13.1 1.84 25 142 42 11.1 13.3 2 30 136
050 25.6 13.1 15.4 1.33 8 162 28.3 13.1 15.4 1.52 11 159 34.5 13.6 15.8 1.82 16 152 53 14.2 16.2 2.52 30 130 56 14.4 16.4 2.69 34 123
060 29.7 14.3 18.2 1.51 7 163 32.8 14.4 18.2 1.73 9 159 40.1 14.9 18.6 2.07 13 153 58 16.1 19.6 2.77 23 132 62 16.3 19.8 2.98 26 124
070 35.4 16.1 21 1.7 7 161 39.1 16.2 21 1.95 9 157 47.9 16.8 21.5 2.33 13 149 64 18.8 23.3 3.08 23 125 70 19 23.6 3.34 27 115
080 41.1 19.6 24.3 2.11 8 201 45.4 19.7 24.3 2.42 11 194 56 20.5 24.9 2.9 16 180 80 21.6 25.8 3.83 28 144 86 21.8 26.2 4.12 32 130
017 40 9.11 5.52 6.51 0.49 12 281 10.1 5.54 6.49 0.56 15 273 12.3 5.71 6.58 0.67 20 259 19 5.47 6.25 0.91 35 223 20.8 5.52 6.28 0.99 40 209
021 11 6.71 7.61 0.6 10 275 12.2 6.75 7.59 0.68 13 265 14.9 6.95 7.72 0.82 19 247 23 6.85 7.56 1.1 34 202 25.2 6.91 7.63 1.21 41 183
026 12.6 6.96 7.8 0.69 9 269 14 7 7.77 0.79 12 257 17.1 7.21 7.92 0.95 18 236 26.3 7.88 8.56 1.26 32 185 28.7 7.97 8.67 1.37 39 163
033 16.8 10.5 11.5 0.92 12 245 18.7 10.6 11.5 1.06 15 227 23 10.9 11.8 1.27 21 194 35.6 10.5 11.6 1.7 35 116 38.9 10.6 11.8 1.85 41 83
040 19 10.4 13 0.98 7 163 21 10.5 13 1.13 9 161 25.7 10.9 13.3 1.36 14 156 37.8 12.1 14.3 1.8 24 144 41.1 12.2 14.4 1.96 29 138
050 25.1 14.4 16.8 1.29 8 162 27.8 14.5 16.8 1.48 10 159 34.1 15 17.2 1.79 15 153 50 15.8 17.8 2.4 27 134 54 16 18 2.57 31 127
060 29.1 15.8 19.7 1.47 6 163 32.3 15.9 19.7 1.69 8 160 39.6 16.4 20.1 2.03 12 153 56 17.9 21.4 2.7 22 134 61 18.1 21.6 2.91 25 127
070 34.7 17.9 22.8 1.66 7 162 38.5 18 22.8 1.9 9 158 47.3 18.6 23.3 2.28 13 150 63 20.8 25.3 3.03 22 127 68 21.1 25.6 3.28 26 117
080 40.3 21.7 26.5 2.06 8 203 44.7 21.9 26.4 2.36 11 195 55 22.6 27 2.84 15 181 78 24.1 28.3 3.75 27 147 84 24.3 28.6 4.04 31 134
017 45 - - - - - - 9.9 6.1 7.06 0.54 14 276 12.1 6.27 7.15 0.65 19 262 18.3 6.11 6.89 0.88 32 229 20.1 6.15 6.92 0.96 38 215
021 - - - - - - 12 7.42 8.28 0.66 12 268 14.8 7.63 8.41 0.8 18 250 22.1 7.63 8.34 1.06 32 210 24.2 7.69 8.4 1.16 38 192
026 - - - - - - 13.7 7.7 8.49 0.76 11 261 16.9 7.91 8.63 0.92 17 240 25.5 8.69 9.35 1.22 30 192 27.9 8.77 9.46 1.33 36 170
033 - - - - - - 18.4 11.6 12.6 1.02 14 232 22.7 12 12.9 1.24 20 200 34.5 11.5 12.6 1.65 33 126 37.7 11.7 12.8 1.8 39 95
040 - - - - - - 20.7 11.7 14.2 1.09 9 162 25.5 12 14.4 1.32 13 157 37.2 13.4 15.6 1.77 23 145 40.5 13.5 15.7 1.93 28 139
050 - - - - - - 27.4 16.1 18.4 1.43 10 160 33.8 16.6 18.8 1.73 14 154 48.2 17.5 19.5 2.31 25 137 52 17.7 19.7 2.48 29 131
060 - - - - - - 31.8 17.6 21.4 1.63 8 161 39.2 18.1 21.8 1.97 12 155 55 19.9 23.4 2.64 21 136 59 20.1 23.6 2.85 24 129
070 - - - - - - 37.9 20 24.9 1.83 8 159 51 22.4 27 2.44 14 146 62 23 27.5 2.97 21 129 67 23.3 27.8 3.23 25 119
080 - - - - - - 43.9 24.3 28.9 2.28 10 197 54 25.1 29.5 2.76 14 184 77 26.8 31.1 3.7 26 149 83 27.1 31.4 4 30 136
017 50 - - - - - - - - - - - - 12 6.9 7.8 0.63 18 265 17.6 6.78 7.58 0.84 30 234 19.4 6.83 7.6 0.93 36 221
021 - - - - - - - - - - - - 14.6 8.39 9.19 0.77 17 255 21.1 8.46 9.17 1.01 29 218 23.2 8.52 9.22 1.11 35 200
026 - - - - - - - - - - - - 16.7 8.71 9.44 0.88 15 245 24.6 9.56 10.2 1.18 28 199 27 9.64 10.3 1.29 34 178
033 - - - - - - - - - - - - 22.5 13.2 14.1 1.19 18 208 33.3 12.7 13.7 1.59 31 137 36.6 12.8 14 1.74 37 106
040 - - - - - - - - - - - - 25.2 13.4 15.8 1.27 12 158 36.8 14.8 17.1 1.75 23 145 40.1 15 17.2 1.91 27 140
050 - - - - - - - - - - - - 33.4 18.4 20.6 1.67 13 156 46.7 19.2 21.3 2.23 23 140 50 19.5 21.5 2.41 27 134
060 - - - - - - - - - - - - 38.7 20 23.8 1.9 11 156 54 22 25.6 2.6 20 138 59 22.3 25.7 2.81 23 131
070 - - - - - - - - - - - - 49.6 24.8 29.4 2.38 14 148 61 25.5 30 2.91 21 131 66 25.7 30.2 3.17 24 122
080 - - - - - - - - - - - - 54 27.8 32.3 2.65 13 187 77 29.9 34.2 3.7 26 149 83 30.2 34.5 3.99 30 136

Legend: Heating capacity at low outdoor temperature


LWT Leaving water temperature The published heating capacities are instantaneous capacities. They do not take account of the
CAP kW Net nominal heating capacity = gross heating capacity minus the capacity decrease of the heating capacity, resulting from the formation of frost on the coil and the effect
corresponding to the available pressure (flow x pressure/0.3). of the defrost cycles.
COMP kW Compressor power input The integrated heating capacity takes these effects into account. They depend on the tempera-
UNIT kW Unit power input. (compressors, fan, control circuit and pumps) minus the ture and the relative humidity (rh) of the outdoor air.
capacity corresponding to the available pressure (flow x pressure/0.3).
COND l/s Condenser water flow rate Correction factor to obtain integrated heating capacities
COND kPa Condenser pressure drop
Leaving water temp. °C Outdoor temperature ˚C (87% rh)
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module)
-10 -5 0 7 10
Capacity based on standard EUROVENT conditions
30 0.88 0.85 0.87 1 1
Full load correction factors for Eurovent laboratory test: 35 0.87 0.85 0.87 1 1
Net heating capacity 1.000 40 0.88 0.85 0.87 1 1
Energy efficiency ratio 1.000 45 0.89 0.86 0.88 1 1
Evaporator pressure drop 1.000
50 0.91 0.89 0.91 1 1
Application data:
Standard units Note:
Refrigerant: R-407C The Carrier electronic selection program permits calculating the integrated heating capacity as a
Condenser temperature rise: 5 K function of the actual humidity conditions at the installation site. Contact Carrier for your person-
Condenser fluid: water alised heat pump selection.
Fouling factor: 0.44 x 10-4 (m2 K)/W

Performances in accordance with EN 255.

9
Heating capacities, double pump
30RYH Entering air temperature, ˚C

-10 -5 0 7 10
LWT

CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES CAP COMP UNIT COND PRES

˚C kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa
040 30 21 8.57 12.6 1.03 8 208 23 8.63 12.5 1.17 10 206 27.6 8.99 12.7 1.4 15 202 41 9.92 13.4 1.9 27 189 44.3 10.1 13.5 2.06 32 183
050 27.3 11.9 15.7 1.35 9 208 29.9 12 15.6 1.54 11 205 36.1 12.5 15.9 1.84 16 200 56 12.8 15.9 2.65 33 179 60 13 16 2.82 37 173
060 31.4 13.1 18.3 1.54 7 209 34.4 13.1 18.2 1.75 9 207 41.7 13.7 18.6 2.1 13 202 60 14.5 19 2.85 24 186 65 14.7 19.1 3.06 28 181
070 37.2 14.6 20.8 1.73 7 209 40.8 14.7 20.7 1.97 9 206 49.5 15.3 21.1 2.36 14 200 66 17 22.4 3.13 24 184 71 17.2 22.6 3.39 28 177
080 42.9 17.8 23.7 2.15 9 206 47.2 17.9 23.7 2.45 11 202 57 18.7 24.2 2.93 16 194 83 19.4 24.5 3.95 30 169 89 19.6 24.8 4.25 34 160
040 35 20.7 9.43 13.4 1.01 8 208 22.6 9.49 13.4 1.15 10 206 27.3 9.85 13.6 1.38 14 202 39.8 10.9 14.4 1.84 25 190 43.1 11.1 14.5 2 30 185
050 26.8 13.1 16.8 1.33 8 208 29.5 13.1 16.8 1.52 11 205 35.7 13.6 17.1 1.82 16 200 54 14.2 17.4 2.52 30 183 57 14.4 17.5 2.69 34 178
060 30.9 14.3 19.6 1.51 7 210 33.9 14.4 19.5 1.73 9 207 41.2 14.9 19.8 2.07 13 202 59 16.1 20.7 2.77 23 188 63 16.3 20.8 2.98 26 183
070 36.6 16.1 22.3 1.7 7 209 40.2 16.2 22.3 1.95 9 206 48.9 16.8 22.7 2.33 13 201 65 18.8 24.3 3.08 23 185 70 19 24.4 3.34 27 179
080 42.2 19.6 25.6 2.11 8 206 46.5 19.7 25.5 2.42 11 202 57 20.5 26 2.9 16 194 80 21.6 26.8 3.83 28 172 86 21.8 27 4.12 32 164
040 40 20.3 10.4 14.5 0.98 7 209 22.3 10.5 14.4 1.13 9 207 27 10.9 14.6 1.36 14 203 38.9 12.1 15.6 1.8 24 192 42.2 12.2 15.7 1.96 29 187
050 26.4 14.4 18.2 1.29 8 209 29 14.5 18.2 1.48 10 206 35.3 15 18.5 1.79 15 201 51 15.8 19 2.4 27 187 55 16 19.1 2.57 31 182
060 30.4 15.8 21.1 1.47 6 210 33.5 15.9 21 1.69 8 208 40.7 16.4 21.3 2.03 12 203 57 17.9 22.5 2.7 22 190 62 18.1 22.6 2.91 25 185
070 35.9 17.9 24.1 1.66 7 209 39.6 18 24.1 1.9 9 207 48.4 18.6 24.5 2.28 13 201 64 20.8 26.3 3.03 22 187 69 21.1 26.5 3.28 26 180
080 41.4 21.7 27.7 2.06 8 207 45.8 21.9 27.7 2.36 11 203 56 22.6 28.2 2.84 15 195 79 24.1 29.3 3.75 27 175 85 24.3 29.5 4.04 31 166
040 45 - - - - - - 22 11.7 15.6 1.09 9 207 26.7 12 15.8 1.32 13 203 38.3 13.4 16.9 1.77 23 193 41.6 13.5 17 1.93 28 188
050 - - - - - - 28.6 16.1 19.8 1.43 10 207 34.9 16.6 20.1 1.73 14 202 49.3 17.5 20.7 2.31 25 189 53 17.7 20.8 2.48 29 184
060 - - - - - - 32.9 17.6 22.8 1.63 8 208 40.3 18.1 23.1 1.97 12 204 56 19.9 24.5 2.64 21 191 60 20.1 24.6 2.85 24 186
070 - - - - - - 39 20 26.2 1.83 8 208 52 22.4 28.1 2.44 14 199 63 23 28.5 2.97 21 188 68 23.3 28.7 3.23 25 182
080 - - - - - - 45.1 24.3 30.2 2.28 10 204 55 25.1 30.7 2.76 14 197 78 26.8 32.1 3.7 26 176 84 27.1 32.3 4 30 168
040 50 - - - - - - - - - - - - 26.4 13.4 17.2 1.27 12 204 38 14.8 18.4 1.75 23 193 41.3 15 18.5 1.91 27 188
050 - - - - - - - - - - - - 34.6 18.4 21.9 1.67 13 203 47.8 19.2 22.5 2.23 23 191 51 19.5 22.7 2.41 27 186
060 - - - - - - - - - - - - 39.9 20 25 1.9 11 205 55 22 26.7 2.6 20 192 59 22.3 26.8 2.81 23 187
070 - - - - - - - - - - - - 51 24.8 30.6 2.38 14 200 62 25.5 31 2.91 21 189 67 25.7 31.2 3.17 24 183
080 - - - - - - - - - - - - 55 27.8 33.5 2.65 13 199 78 29.9 35.2 3.7 26 176 84 30.2 35.4 3.99 30 168

Legend: Heating capacity at low outdoor temperature


LWT Leaving water temperature The published heating capacities are instantaneous capacities. They do not take account of the
CAP kW Net nominal heating capacity = gross heating capacity minus the capacity decrease of the heating capacity, resulting from the formation of frost on the coil and the effect
corresponding to the available pressure (flow x pressure/0.3). of the defrost cycles.
COMP kW Compressor power input The integrated heating capacity takes these effects into account. They depend on the tempera-
UNIT kW Unit power input, (compressors, fan, control circuit and pumps) minus the ture and the relative humidity (rh) of the outdoor air.
capacity corresponding to the available pressure (flow x pressure/0.3).
COND l/s Condenser water flow rate Correction factor to obtain integrated heating capacities
COND kPa Condenser pressure drop
Leaving water temp. °C Outdoor temperature ˚C (87% rh)
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module)
-10 -5 0 7 10
Capacity based on standard EUROVENT conditions
30 0.88 0.85 0.87 1 1
Full load correction factors for Eurovent laboratory test: 35 0.87 0.85 0.87 1 1
Net heating capacity 1.000 40 0.88 0.85 0.87 1 1
Energy efficiency ratio 1.000 45 0.89 0.86 0.88 1 1
Evaporator pressure drop 1.000
50 0.91 0.89 0.91 1 1
Application data:
Standard units Note:
Refrigerant: R-407C The Carrier electronic selection program permits calculating the integrated heating capacity as a
Condenser temperature rise: 5 K function of the actual humidity conditions at the installation site. Contact Carrier for your
Condenser fluid: water personalised heat pump selection.
Fouling factor: 0.44 x 10-4 (m2 K)/W

Performances in accordance with EN 255.

10
Cooling capacities, single pump
30RYH Condenser entering air temperature, °C

25 30 35 40 45
LWT

CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES

˚C kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa

017 5 18.4 4.67 5.45 0.88 33 228 17.5 5.19 5.98 0.84 30 235 16.6 5.75 6.56 0.79 27 242 15.6 6.35 7.18 0.75 25 248 14.6 6.99 7.84 0.7 22 255
021 23.4 6.32 7.03 1.11 35 200 22.2 6.96 7.67 1.06 32 210 21 7.66 8.37 1 28 220 19.8 8.41 9.14 0.94 25 229 18.5 9.21 9.96 0.88 22 238
026 25 7.06 7.73 1.19 29 197 23.8 7.77 8.44 1.13 26 207 22.6 8.55 9.22 1.08 23 216 21.4 9.39 10.1 1.02 21 226 20.1 10.3 11 0.96 18 235
033 32.4 9.66 10.7 1.54 30 146 30.9 10.6 11.6 1.47 27 160 29.3 11.7 12.6 1.39 25 174 27.7 12.8 13.7 1.32 22 187 26 14 14.9 1.24 20 200
040 39.4 11.1 13.3 1.89 27 140 37.2 12.2 14.5 1.79 24 144 35.1 13.5 15.7 1.68 21 147 33 14.8 17.1 1.59 19 150 30.9 16.2 18.6 1.49 17 153
050 47.1 13.7 15.8 2.25 24 140 44.5 15.3 17.4 2.12 21 144 41.9 16.9 19.1 2 19 147 39.2 18.7 20.8 1.88 16 151 36.6 20.5 22.7 1.75 14 154
060 59 16.2 19.7 2.83 24 130 56 17.9 21.4 2.68 21 135 53 19.7 23.2 2.52 19 140 49.8 21.6 25.2 2.37 17 145 46.6 23.7 27.3 2.22 15 149
070 68 19.3 23.8 3.23 25 119 64 21.2 25.7 3.06 23 126 61 23.3 27.8 2.9 20 132 57 25.5 30.1 2.73 18 137 54 27.9 32.5 2.56 16 143
080 81 22.4 26.7 3.84 28 143 77 24.8 29.1 3.63 25 152 72 27.3 31.6 3.42 22 161 68 30 34.3 3.21 20 169 63 32.8 37.2 2.99 17 176
017 6 19.1 4.71 5.48 0.91 35 223 18.2 5.23 6.02 0.87 32 230 17.2 5.8 6.6 0.82 29 237 16.2 6.4 7.22 0.78 26 244 15.2 7.04 7.88 0.73 23 251
021 24.2 6.39 7.1 1.15 37 193 23 7.03 7.74 1.09 34 204 21.8 7.73 8.44 1.04 30 214 20.5 8.48 9.2 0.98 27 224 19.2 9.28 10 0.92 24 233
026 25.9 7.14 7.81 1.23 31 190 24.7 7.85 8.52 1.17 28 200 23.4 8.63 9.3 1.11 25 210 22.2 9.47 10.1 1.05 22 220 20.9 10.4 11.1 0.99 20 229
033 33.5 9.77 10.8 1.6 31 136 32 10.7 11.7 1.52 29 151 30.4 11.8 12.7 1.44 26 165 28.7 12.9 13.8 1.36 24 179 27 14.1 15 1.28 21 193
040 40.8 11.2 13.4 1.96 29 138 38.6 12.4 14.6 1.85 26 142 36.4 13.6 15.9 1.75 23 145 34.2 15 17.2 1.64 20 149 32.1 16.4 18.7 1.54 18 152
050 48.6 13.9 16 2.32 25 137 46 15.5 17.6 2.19 22 141 43.3 17.1 19.2 2.07 20 145 40.6 18.9 21 1.94 18 149 37.9 20.7 22.9 1.82 15 152
060 61 16.4 19.8 2.92 25 127 58 18.1 21.6 2.77 23 132 55 19.9 23.4 2.61 20 138 52 21.9 25.4 2.46 18 142 48.3 23.9 27.5 2.3 16 147
070 70 19.5 24 3.34 27 115 67 21.5 26 3.17 24 122 63 23.6 28.1 3 22 128 59 25.8 30.3 2.83 19 134 56 28.2 32.8 2.65 17 140
080 84 22.7 27.1 3.96 30 138 79 25.1 29.4 3.75 27 147 74 27.6 31.9 3.53 24 156 70 30.3 34.6 3.32 21 165 65 33.2 37.5 3.1 18 173
017 7 19.8 4.75 5.52 0.94 37 217 18.8 5.28 6.05 0.9 34 225 17.8 5.85 6.63 0.85 31 233 16.8 6.45 7.26 0.8 28 240 15.8 7.09 7.92 0.76 25 247
021 25 6.46 7.17 1.19 40 186 23.8 7.1 7.81 1.13 36 197 22.5 7.8 8.51 1.07 32 208 21.2 8.55 9.27 1.01 29 218 19.9 9.36 10.1 0.95 25 228
026 26.8 7.21 7.89 1.27 33 182 25.5 7.93 8.6 1.21 30 193 24.2 8.71 9.37 1.15 27 204 22.9 9.55 10.2 1.09 24 214 21.6 10.4 11.1 1.03 21 224
033 34.6 9.87 10.9 1.65 33 125 33 10.8 11.8 1.57 31 141 31.4 11.9 12.8 1.49 28 156 29.7 13 13.9 1.41 25 171 28 14.2 15.1 1.33 23 185
040 42.2 11.3 13.5 2.02 31 135 39.9 12.5 14.7 1.91 27 140 37.7 13.8 16 1.81 24 143 35.4 15.1 17.4 1.7 22 147 33.2 16.6 18.9 1.6 19 150
050 50 14.1 16.2 2.39 27 134 47.4 15.7 17.7 2.26 24 139 44.8 17.3 19.4 2.14 21 143 42.1 19.1 21.2 2.01 19 147 39.3 20.9 23 1.88 17 151
060 63 16.6 20 3.01 27 123 60 18.3 21.8 2.85 24 129 57 20.2 23.7 2.7 21 135 53 22.1 25.6 2.54 19 140 50 24.2 27.7 2.38 17 145
070 72 19.8 24.3 3.44 29 110 69 21.7 26.2 3.27 26 118 65 23.8 28.3 3.1 23 125 61 26.1 30.6 2.92 21 131 58 28.5 33 2.74 18 137
080 86 23 27.4 4.09 32 132 81 25.4 29.7 3.87 28 142 77 27.9 32.2 3.64 25 152 72 30.7 35 3.42 22 161 67 33.6 37.9 3.2 19 169
017 8 20.5 4.79 5.55 0.98 39 212 19.5 5.32 6.09 0.93 36 220 18.5 5.89 6.67 0.88 33 228 17.4 6.5 7.3 0.83 30 236 16.3 7.15 7.96 0.78 27 243
021 25.8 6.52 7.24 1.23 43 178 24.5 7.17 7.88 1.17 39 190 23.3 7.87 8.58 1.11 35 201 22 8.62 9.33 1.05 31 212 20.6 9.43 10.2 0.98 27 223
026 27.6 7.28 7.97 1.32 35 174 26.4 8 8.68 1.25 32 186 25.1 8.79 9.45 1.19 29 197 23.7 9.63 10.3 1.13 26 208 22.4 10.5 11.2 1.06 23 218
033 35.7 9.97 11.1 1.71 35 114 34.1 10.9 12 1.63 32 130 32.4 12 13 1.55 30 146 30.7 13.1 14.1 1.46 27 162 28.9 14.3 15.2 1.38 24 177
040 43.7 11.5 13.7 2.09 33 133 41.3 12.7 14.8 1.98 29 137 39 13.9 16.1 1.87 26 141 36.7 15.3 17.5 1.76 23 145 34.4 16.7 19 1.65 20 148
050 52 14.3 16.4 2.46 28 132 48.9 15.9 17.9 2.33 25 137 46.2 17.5 19.6 2.2 23 141 43.5 19.2 21.3 2.08 20 145 40.7 21.1 23.2 1.95 18 149
060 65 16.8 20.2 3.11 28 119 62 18.5 22 2.94 26 126 58 20.4 23.9 2.78 23 132 55 22.4 25.9 2.62 20 137 52 24.4 28 2.46 18 142
070 75 20 24.5 3.55 31 105 71 21.9 26.5 3.38 28 113 67 24.1 28.6 3.2 25 121 63 26.3 30.9 3.01 22 128 59 28.8 33.3 2.83 19 134
080 89 23.3 27.7 4.21 34 126 84 25.7 30 3.98 30 137 79 28.3 32.6 3.76 27 147 74 31 35.3 3.53 24 156 70 33.9 38.2 3.3 21 165
017 10 21.8 4.88 5.63 1.04 44 200 20.8 5.41 6.17 0.99 40 209 19.7 5.99 6.75 0.94 37 218 18.6 6.6 7.38 0.89 33 227 17.5 7.25 8.04 0.83 30 235
021 27.4 6.66 7.4 1.31 48 162 26.1 7.31 8.03 1.24 44 175 24.8 8.01 8.72 1.18 39 188 23.4 8.77 9.47 1.12 35 200 22 9.58 10.3 1.05 31 212
026 29.4 7.43 8.15 1.4 40 158 28 8.16 8.85 1.33 36 170 26.7 8.94 9.62 1.27 33 183 25.3 9.79 10.5 1.2 29 195 23.9 10.7 11.4 1.14 26 207
033 37.9 10.2 11.4 1.82 40 91 36.2 11.1 12.3 1.73 36 109 34.5 12.2 13.2 1.65 33 126 32.7 13.3 14.3 1.56 30 144 30.9 14.5 15.5 1.47 27 161
040 46.5 11.8 13.9 2.22 37 127 44 12.9 15.1 2.1 33 132 41.5 14.2 16.4 1.99 29 137 39.1 15.6 17.8 1.87 26 141 36.7 17 19.3 1.76 23 145
050 55 14.7 16.7 2.6 32 126 52 16.3 18.3 2.47 29 131 49.1 17.9 19.9 2.34 26 136 46.3 19.6 21.7 2.21 23 141 43.5 21.4 23.5 2.08 20 145
060 69 17.2 20.7 3.29 32 111 66 18.9 22.4 3.12 29 119 62 20.8 24.3 2.95 26 125 58 22.8 26.3 2.78 23 132 55 24.9 28.4 2.61 20 137
070 79 20.4 25.1 3.77 35 95 75 22.4 27 3.58 31 104 71 24.6 29.1 3.39 28 112 67 26.9 31.4 3.2 25 120 63 29.3 33.8 3.01 22 128
080 94 23.9 28.4 4.45 38 114 89 26.3 30.7 4.22 34 126 84 28.9 33.2 3.98 30 137 79 31.7 36 3.75 27 147 74 34.6 38.9 3.51 23 157

Legend: Full load correction factors for Eurovent laboratory test:


LWT Leaving water temperature Net cooling capacity 1.000
CAP kW Net cooling capacity = gross cooling capacity plus the capacity corresponding to Energy efficiency ratio 1.000
the available pressure (flow x pressure/0.3). Evaporator pressure drop 1.000
COMP kW Compressor power input
UNIT kW Unit power input (compressors, fan, control circuit and pumps) minus the Application data:
capacity corresponding to the available pressure (flow x pressure/0.3). Standard units
COOL l/s Evaporator water flow rate Refrigerant: R-407C
COOL kPa Evaporator pressure drop Evaporator temperature rise: 5 K
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module) Evaporator fluid: chilled water
Fouling factor: 0.44 x 10-4 (m2 K)/W
Capacity based on standard EUROVENT conditions
Performances in accordance with EN 12055.
Cooling capacities, dual pump
30RYH Condenser entering air temperature, °C

25 30 35 40 45
LWT

CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES CAP COMP UNIT COOL PRES

˚C kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa kW kW kW l/s kPa kPa

040 5 38.3 11.1 14.6 1.89 27 189 36.1 12.2 15.8 1.79 24 192 33.9 13.5 17.1 1.68 21 195 31.8 14.8 18.5 1.59 19 197 29.7 16.2 19.9 1.49 17 200
050 46 13.7 17 2.25 24 191 43.4 15.3 18.6 2.12 21 194 40.7 16.9 20.3 2 19 197 38.1 18.7 22.1 1.88 16 199 35.4 20.5 24 1.75 14 202
060 59 16.2 20.7 2.83 24 187 55 17.9 22.5 2.68 21 191 52 19.7 24.4 2.52 19 194 48.8 21.6 26.4 2.37 17 197 45.6 23.7 28.5 2.22 15 200
070 67 19.3 24.7 3.23 25 182 64 21.2 26.7 3.06 23 186 60 23.3 28.9 2.9 20 190 56 25.5 31.2 2.73 18 193 53 27.9 33.6 2.56 16 197
080 80 22.4 27.6 3.84 28 172 76 24.8 30 3.63 25 178 71 27.3 32.6 3.42 22 183 67 30 35.4 3.21 20 188 62 32.8 38.3 2.99 17 192
040 6 39.7 11.2 14.7 1.96 29 187 37.5 12.4 15.9 1.85 26 190 35.2 13.6 17.2 1.75 23 193 33 15 18.6 1.64 20 196 30.9 16.4 20.1 1.54 18 199
050 47.6 13.9 17.2 2.32 25 189 44.9 15.5 18.8 2.19 22 192 42.2 17.1 20.5 2.07 20 195 39.5 18.9 22.3 1.94 18 198 36.8 20.7 24.2 1.82 15 200
060 60 16.4 20.9 2.92 25 185 57 18.1 22.7 2.77 23 189 54 19.9 24.6 2.61 20 192 51 21.9 26.6 2.46 18 195 47.3 23.9 28.7 2.3 16 198
070 69 19.5 24.9 3.34 27 179 66 21.5 26.9 3.17 24 183 62 23.6 29.1 3 22 187 58 25.8 31.4 2.83 19 191 55 28.2 33.9 2.65 17 195
080 83 22.7 27.9 3.96 30 169 78 25.1 30.3 3.75 27 175 74 27.6 32.9 3.53 24 180 69 30.3 35.7 3.32 21 185 64 33.2 38.6 3.1 18 190
040 7 41.1 11.3 14.8 2.02 31 185 38.8 12.5 16 1.91 27 188 36.5 13.8 17.3 1.81 24 192 34.3 15.1 18.7 1.7 22 194 32.1 16.6 20.2 1.6 19 197
050 49.1 14.1 17.3 2.39 27 187 46.4 15.7 18.9 2.26 24 190 43.7 17.3 20.6 2.14 21 193 40.9 19.1 22.4 2.01 19 196 38.2 20.9 24.3 1.88 17 199
060 62 16.6 21 3.01 27 182 59 18.3 22.8 2.85 24 186 56 20.2 24.8 2.7 21 190 52 22.1 26.8 2.54 19 194 48.9 24.2 28.9 2.38 17 197
070 72 19.8 25.1 3.44 29 176 68 21.7 27.1 3.27 26 181 64 23.8 29.3 3.1 23 185 61 26.1 31.6 2.92 21 189 57 28.5 34.1 2.74 18 193
080 85 23 28.2 4.09 32 165 81 25.4 30.6 3.87 28 171 76 27.9 33.2 3.64 25 177 71 30.7 36 3.42 22 183 67 33.6 39 3.2 19 188
040 8 42.6 11.5 14.9 2.09 33 182 40.2 12.7 16.1 1.98 29 186 37.8 13.9 17.4 1.87 26 190 35.5 15.3 18.8 1.76 23 193 33.2 16.7 20.3 1.65 20 196
050 51 14.3 17.5 2.46 28 185 47.9 15.9 19.1 2.33 25 188 45.1 17.5 20.8 2.2 23 192 42.4 19.2 22.6 2.08 20 195 39.6 21.1 24.5 1.95 18 198
060 64 16.8 21.2 3.11 28 180 61 18.5 23 2.94 26 184 58 20.4 24.9 2.78 23 188 54 22.4 27 2.62 20 192 51 24.4 29.1 2.46 18 195
070 74 20 25.3 3.55 31 173 70 21.9 27.3 3.38 28 178 66 24.1 29.5 3.2 25 183 63 26.3 31.9 3.01 22 187 59 28.8 34.4 2.83 19 191
080 88 23.3 28.5 4.21 34 161 83 25.7 30.9 3.98 30 168 78 28.3 33.5 3.76 27 174 74 31 36.3 3.53 24 180 69 33.9 39.3 3.3 21 186
040 10 45.4 11.8 15.1 2.22 37 178 42.9 12.9 16.4 2.1 33 182 40.4 14.2 17.7 1.99 29 186 38 15.6 19.1 1.87 26 189 35.5 17 20.6 1.76 23 193
050 54 14.7 17.9 2.6 32 181 51 16.3 19.4 2.47 29 184 48 17.9 21.1 2.34 26 188 45.2 19.6 22.9 2.21 23 192 42.4 21.4 24.8 2.08 20 195
060 68 17.2 21.6 3.29 32 174 65 18.9 23.4 3.12 29 179 61 20.8 25.3 2.95 26 184 58 22.8 27.4 2.78 23 188 54 24.9 29.6 2.61 20 192
070 79 20.4 25.8 3.77 35 166 75 22.4 27.8 3.58 31 172 71 24.6 30 3.39 28 177 67 26.9 32.3 3.2 25 182 62 29.3 34.8 3.01 22 187
080 93 23.9 29 4.45 38 153 88 26.3 31.5 4.22 34 161 83 28.9 34.1 3.98 30 168 78 31.7 36.9 3.75 27 175 73 34.6 39.9 3.51 23 181

Legend: Full load correction factors for Eurovent laboratory test:


LWT Leaving water temperature Net cooling capacity 1.000
CAP kW Net cooling capacity = gross cooling capacity plus the capacity corresponding to Energy efficiency ratio 1.000
the available pressure (flow x pressure/0.3). Evaporator pressure drop 1.000
COMP kW Compressor power input
UNIT kW Unit power input (compressors, fan, control circuit and pumps) minus the Application data:
capacity corresponding to the available pressure (flow x pressure/0.3). Standard units
COOL l/s Evaporator water flow rate Refrigerant: R-407C
COOL kPa Evaporator pressure drop Evaporator temperature rise: 5 K
PRES kPa Available pressure at the unit outlet (unit with single-pump hydronic module) Evaporator fluid: chilled water
Fouling factor: 0.44 x 10-4 (m2 K)/W
Capacity based on standard EUROVENT conditions
Performances in accordance with EN 12055.

12
Guide specifications
Carrier model number: 30RYH
Nominal cooling capacity 18-77 kW Air heat exchanger/fan
Nominal heating capacity 18-78 kW ■ One vertical coil with slotted aluminium fins expanded into
grooved copper tubes. Protection against ice build-up by
Part 1 - General electric resistance heater on the coil support.
■ Axial fan with available pressure and profiled airfoil blades
System description for quiet operation. Three-phase, two-speed motor
(24/12 r/s), insulation class F, protection category IP 55,
■ Air-to-water reversible heat pumps for indoor installation, overload protection by internal motor sensors. Vertical air
equipped with scroll compressors, a fan with available flow with rigid connection collar for the air outlet duct.
pressure, auto-adaptive microprocessor control and
operating with HFC-407C refrigerant which has no effect Refrigerant circuit
on the ozone layer. ■ The circuit includes: a four-way cycle reversing valve,
liquid line valve, moisture sight glass, two-way expansion
Quality assurance device, receiver/heat exchanger, protecting the compressor
against refrigerant migration, removable suction line screen
■ 30RYH units comply with requirements of European filter, high-pressure safety valve (30RYH 040-080),
directives: pressure and temperature sensors, manually reset high
- pressurised equipment directive (PED) 97/23/EC pressure switch, and a refrigerant charge of HFC-407C. All
- machinery directive 98/37/CE, modified, components of the refrigerant circuit are welded for total
- low voltage directive 73/23/EEC, modified. and lasting leak-tightness.
- electromagnetic compatibility directive 89/336/EEC,
modified Control and power circuit control box
and with the applicable recommendations of European ■ The control box is accessible via a hinged door. It includes
standards: a main disconnect switch, fuses and circuit breakers,
- machine safety, electrical equipment in machines, compressor, fan and water pump contactors, thermal relays
general regulations: EN 60204-1, and fan sensor relays, low-voltage control circuit
- radiated electromagnetic emissions: EN 50081-1, transformer (24 V control circuit) and the Pro-Dialog
- conducted electromagnetic emissions: EN 50081-2, control system.
- electromagnetic immunity EN 50082-2.
The whole unit is supplied by a single power connection
30RYH units have been designed and tested in a facility point (three-phase supply without neutral).
with a quality assurance system certified ISO 9001.
30RYH units have been assembled in a facility with an Chassis/cabinet
environment management system certified ISO 14001. ■ Chassis and cabinet made of galvanised sheet steel. Painted
The published performances have been certified by in oven-baked polyester powder paint in light grey colour
Eurovent and verified by independent laboratories. (RAL 7035). Removable panels with 1/4 turn locks.
All units undergo a run test before shipment. Compressor, water heat exchanger and hydronic module of
sizes 30RYH 017-033 are located in a technical
Part 2 - Products compartment, isolated from the air flow.
Equipment Hydronic module
■ Hydronic module, integrated into the heat pump, including:
Compressor removable screen filter, expansion tank, single centrifugal
■ Hermetic scroll compressor with only three moving parts, water pump (dual water pump optional for sizes 30RYH
2-pole electric motor, cooled by suction gas with overload 040-080) with three-phase motor, water flow switch, safety
protection through an internal thermostat and/or thermal valve, set to 3 bar, flow control valve, pressure gauge and
relay. Oil level sight glass and polyolester synthetic oil purges.
charge. Internal piping made of galvanised steel. Customer-side
Victaulic connections with welding or screw connection
Water heat exchanger sleeves.
■ Stainless steel plate heat exchanger with welded copper Protection against ice build-up down to -20°C by thermal
connections. Closed-cell thermal foam insulation, anti- insulation and water pump cycling.
freeze protection during operation by flow switch (standard Note: Units without hydronic module (option): internal
on all versions). water piping protected against frost down to -20˚C by
■ 30RYH 017-033: the water heat exchanger and the electric resistance heater.
hydronic module are located in a technical compartment,
isolated from the outside air. 30RYH 040-080: the water
heat exchanger and the hydronic modules are protected
against frost at shutdown down to -20°C by electric
resistance heater.

13
Carrier Pro-Dialog Plus control system Operator interface
Pro-Dialog Plus ensures the following functions: ■ Includes status or fault LEDs, two numerical displays, a
refrigerant system synoptic diagram and a command
Control keyboard.
■ Water temperature control by PID loop with compressor ■ Immediate display of parameters: entering/leaving water
run time equalising. The system permanently adjusts the and ambient air temperatures, compressor suction/discharge
system inertia and ensures complete prevention of pressures and temperatures, set point, operating time and
excessive compressor cycling. The heat pump can safely number of compressor start-ups.
operate with a low system water volume which often makes ■ Diagnosis and complete parameter set by selection of one
the use of a buffer tank unnecessary (see minimum water of the following menus: information, temperatures,
volume in this document). pressures, set points, input values, test, configuration,
■ Head pressure control by auto-adaptive algorithm (fan alarms, alarm history and operating log.
speed).
■ Water pump control (optional dual pump with automatic Remote management of the heat pump
change-over). Volt-free contact inputs permit:
■ Control at the second set point (example: unoccupied - Start/stop control
room). Set point reset as a function of the air temperature or - Selection of heating or cooling mode
the difference between entering/leaving water temperature. - Integration of a customer safety device
■ Automatic change-over of heating/cooling, as a function of - Operation at the second set point* (example room
the outdoor temperature with adjustable dead band. unoccupied)
Optional control module with a relay for the control of - Maximum demand limit* (30RYH 050-080)
supplementary electric resistance heaters. Four stages * One or the other
maximum, with start-up of the last stage in case of a heat ■ Outputs are available for:
pump shutdown as a result of a fault condition. - Start-up of a boiler relay (shutdown of the heat pump
below a minimum outdoor temperature)
Safety - Signalling of a fault condition for each circuit.
■ The system checks the evolution of the parameters: ■ The optional/accessory CCN Clock Board permits:
temperatures, pressures ... and responds to maintain the - Control in master/slave configuration of two heat pumps
compressor within the operating range. If despite this one operating in parallel.
parameter exceeds its limit, an alert message is generated or - Programming of operating time schedules (up to 8
the unit is shut down. The following faults cause the periods per week)
refrigerant circuit or the unit to be shut down: - Programming of operating time schedules for the second
- Low suction pressure set point (up to 8 periods per week)
- High discharge pressure - Definition of operating time period with the fan at low
- Low suction temperature speed (for example during the night)
- Low water entering temperature in heating mode - Definition of operating time period with demand limit.
- Compressor, water pump overload - Integration of the heat pump into a building monitoring
- Reverse compressor rotation system (BMS): serial port RS 485.
- Temperature sensor and pressure transducer fault
- Board and loss of communication fault
- Customer safety device tripping
- Water heat exchanger anti-freeze protection
- More than 50 alert or fault codes to facilitate fault
detection

14
15
Manufactured by: Carrier SA, Montluel, France.
Order No. 13424-20, 01 2003. Supersedes order No.: 13424-20, 11-2001 Printed on Totally Chlorine Free Paper.
Manufacturer reserves the right to change any product specifications without notice. Printed in the Netherlands.
The cover photo is solely for illustration purposes, and is not contractually binding.