1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED MODIFY TYPICAL DETAILS 1. ALL REINFORCEMENT SHALL BE .019M CLEAR MINIMUM FROM TOP AND BOTTOM OF SLAB.
AS DIRECTED TO MEET SPECIAL CONDITIONS. 2. FOR TWO-WAY SLAB ALONG THE LONGER SPAN SHALL BE PLACED BELOW BARS NEAR THE SUPPORT UNLESS OTHERWISE INDICATED OR
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS. MISCELLANEOUS IRON, PRE-CAST CONCRETE, DETAILING
SHOWN IN DETAILS THE SPACING OF THE BARS AT THE COLUMN STRIPS CAN BE APPROXIMATELY 131 OF THE MIDDLE STRIP IN NO CASE HOOK (A OR G) L
ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL PRIOR TO PURCHASE, FABRICATION AND INSTALLATION. DIMENSION
GREATER THAN 231 TIMES THE SLAB THICKNESS.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN. CHECK WITH SANITARY, MECHANICAL AND ELECTRICAL 3. UNLESS OTHERWISE DETAILED IN CONDITIONING SLAB HAVING SAME REINFORCEMENT RUNNING IN ONE DIRECTION, REINFORCING SHALL
CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC., TO BE EMBEDDED IN CONCRETE.
d
BEND, EXTENDED OR CUT AS FOLLOWS:
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING AND BRACING OF THE STRUCTURE FOR ALL LOADS 4. TEMPERATURE BARS FOR SLAB SHAL BE GENERALLY PLACED NEAR THE TENSION FACE AND SHALL NOT BE LESS THAN 0.025 BT.
THAT MAYBE IMPOSED DURING CONSTRUCTION.
J
5. UNLESS OTHERWISE NOTED, ALL BEDDED SLAB BE REINFORCED WITH 10mmØ BAR AT .25M O.C. B.W. AT CENTER OF SLAB. CONSTRUCTION D
EMBEDMENT
FOOTING: L1/4
6. PROVIDE EXTRA REINFORCEMENT L1/4
AT CORNERL2/4 L2/4 DISCONTINOUS
SLAB (TWO ADJACENT L3/4 L3/4
EDGE) AS SHOWN BELOW.
4d OR 65 MM MIN DEPTH
1. FOOTINGS WERE DESIGNED TO REST ON SOIL WITH AN ASSUMED BEARING CAPACITY OF 5000psf.
0.30MIN
2. NO FOOTING SHALL REST ON FILL.
WIDTH
180 DEG
t
3. MINIMUM CONCRETE PROTECTION SHALL BE .075M CLEAR FOR CONCRETE DEPOSITED AGAINST THE GROUND AND 0.05M FOR
W
CONCRETE DEPOSITED AGAINST THE FRAMEWORK.
DETAILING
DEPTH
DIMENSION
CONCRETE MIXES AND PLACINGS:
1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDER COMPRESSIVE STRENGHT OF CONCRETE ARE AS FOLLOWS: L1/5 L1/5 L2/5 L2/5 L3/5 L3/5
L1 SPAN
EXTERIOR L2 SPAN
INTERIOR L3 SPAN
INTERIOR .
CANTILEVER
A OR G
LOCATION STREGHT AGGREGATE SIZE MAX. SLUMP
D
12d
4 IN (19mm) REINFORCING STEEL BARS
BEAMS, GIRDERS 3000 psi 3
4 IN (19mm) 4 IN (100mm)
1. ALL REINFORCING STEEL SHALL BE NEW BILLET, HOT ROLLED, WELDABLE, DEFORMED BARS CONFORMING
COLUMN, STAIR 3000 psi 3 4 IN (100mm)
SUSPENDED SLAB 3000 psi
4
3
IN (19mm)
IN (19mm) 4 IN (100mm)
TO THE SPECIFICATIONS OF PNS 49; 1986 (ASTM 615), Fy= 60,000 psi (413.79 Mpa) FOR SIZES >12 AND
Fy = 40,000 psi (275.86 Mpa) FOR SIZES ≤12.
90 DEG
2 TYPICAL COLUMN FOOTING DETAIL
4 2. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, AND SPACED S-01 Scale: 1:30
SHEARWALL/RET. WALL 3000 psi 3
4 IN (19mm) 4 IN (100mm) IN FORMS, SECURED IN THE REQUIRED LOCATION IN ACCORDANCE WITH THE PROCEDURES AND
REQUIREMENTS OUTLINED IN THE LATEST EDITION OF THE BUILDING CODE AND THE MANUAL OF STANDARD STANDARD HOOKS
SLAB ON GRADE 2500 psi 3
IN (19mm) 4 IN (100mm)
4 PRACTICE FOR DETAILED REINFORCED CONCRETE STRUCTURES.
CL
2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED ACCORDING TO THE ACI STANDARDS.
3. ALL REINFORCING STEEL BARS SHALL BE THOUROUGHLY CLEANED OF ALL LOOSE RUST, SOIL OR OTHER
CORROSIVE MATERIAL IMMEDIATELY PRIOR TO PLACING OF CONCRETE.
C
L
VERIFY
3. STRIPPING OF FORMS AND SHORES SHALL BE AS FOLLOWS: 12d FOR 25 MM CL
6d FOR 10, 12, 16 MM
DEVELOPMENT LENGTH, (Ld), IN TENSION FOR RC BEAMS LENGTH OF LAP COMPRESSION SPLICES (mm)
A OR G
FOUNDATION 1 DAY
HOOK
AND GIRDERS (PRISMATIC OR NON-PRISMATIC) BAR SIZE RC WALL
BEAMS, GIRDERS 21 DAYS fc'=21MPa fc'=28MPa fc'=34.5MPa
fc'=21MPa (3000psi) fc'=28MPa (4000psi) fc'=34.5MPa(5000psi) (mm) (3000psi) (4000psi) (5000psi)
COLUMN & WALLS 3 DAYS BAR SIZE
(mm) TOP BARS BOT BARS TOP BARS BOT BARS TOP BARS BOT BARS CHB WALL INTERIOR CHB
SUSPENDED SLAB 17 DAYS 16Ø 420 390 360
DETAILING DIMENSION
(mm) (mm) (mm) (mm) (mm) (mm) D
TENSION LENGTH
32Ø 2990 2300 2600 1985 2300 1780
WHELL BARROWS, OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED 6.0M IN AGGREGATE LENGHT.
NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS, UNLESS 36Ø 3770 2900 3280 2520 2930 2250
100
AUTHORIZED IN WRITING BY THE DESIGNERS AND ONLY FOR USUAL CONDITIONS WHERE VIBRATOR IS
600 (MINIMUM)
TENSION SPLICE CLASSIFICATION:
EXTREMELY DIFFICULT TO ACCOMPLISH. REFER TO DWG. NO. S-01
CLASS A = 1.00Ld 90 DEG 10Ø TRANSVERSE BARS
FOR NOTES ON PREPARATION @ 300 O.C.
CLASS B = 1.33Ld OF SOIL SUB-BASE.
100
BEAMS AND GIRDERS:
DETAILING DIMENSIONA OR G
MASONRY AND CONCRETE BLOCKS:
HOOK
200
3-10Ø LONGITUDINAL BARS REFER TO DWG. NO. S-01
1. UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AT LEAST 6mm FOR 1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF. FOR LOAD BEARING TYPE TIE BEAM FOR NOTES ON PREPARATION
CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGHT OF 6.90 Mpa SHALL BE DEVELOPED. (CONT.) WITH TENSION SPLICE
EVERY 3.0M OF SPAN EXCECPT FOR CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED IN THE OF SOIL SUB-BASE.
6D
PLANS OR AS ORDERED BY THE STRUCTURAL ENGINEER BUT IN NO CASE LESS THAN 19mm FOR EVERY 3.0M 2. PROVIDE 1-16Ø VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS AND EACH SIDE OF MASONRY WALL OPENING.
100 500 100 300
OF FREE SPAN. 3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200mm) ON EACH SIDE OF MASONRY WALL OPENING.
H
4. UNLESS OTHERWISE INDICATED IN THE PLANS, WALL REINFORCEMENT SHALL BE AS FOLLOWS: REFER TO DWG. NO. S-01
2. IF THERE ARE TWO OR MORE LAYERS OF LONGITUDINAL REINFORCING BARS IN A BEAM OR ORDER, USE D
REFER TO DWG. NO. S-01 FOR NOTES ON PREPARATION 3-10Ø LONGITUDINAL BARS
SEPERATORS OF A SIZE NOT LESS THAN 25mm BARS SPACED ABOUT 0.90M ON CENTER. IN NO CASE SHALL FOR NOTES ON PREPARATION OF SOIL SUB-BASE.
THERE LESS THAN TWO (2) SEPERATORS BETWEEN LAYERS OF BARS. CONCRETE HOLLOW BLOCKS REINFORCEMENT (CONTINUOUS) WITH TENSION SPLICE
OF SOIL SUB-BASE.
3. LONGITUDINAL REINFORCING BARFS SHALL BE PLACED SYMMETRICALLY ABOUT THE VERTICAL CENTER
D
D
HORIZONTAL VERTICAL
180 DEG 90 DEG 90 DEG 135 DEG
VAR.
D D HOR. & CENTER VERT.
BAR SIZE BAR SIZE 0.102m 10Ø @ 0.25m O.C. 10Ø @ 0.30m O.C.
(MM) A OR G J A OR G (MM) A OR G A OR G H BARS STAGGERED OUTSIDE
B
VAR.
10Ø 60 125 60 150 10Ø 40 105 105 65 0.127m 10Ø @ 0.20m O.C. 10Ø @ 0.25m O.C. - DO -
12Ø 80 150 105 200 12Ø 50 115 115 80 12Ø @ 0.25m O.C. BOTH FACES HOR.
0.152m 12Ø @ 0.30m O.C. SHALL BE INSIDE
16Ø 95 175 130 250
0.178m 12Ø @ 0.23m O.C. 12Ø @ 0.25m O.C. - DO -
D
20Ø 125 225 175 350
12Ø @ 0.30m O.C. BOTH FACES HOR.
0.208m 12Ø @ 0.30m E.F.
25Ø
32Ø
155
275
275
425
205
335
425
550 0.229m 12Ø @ 0.20m O.C. 12Ø @ 0.25m O.C. E.F.
SHALL BE OUTSIDE
- DO -
7 DETAIL OF SLAB ON FILL / GRADE
S-01 Scale: 1:10
0.254m 12Ø @ 0.30m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
COLUMN: 0.275m 12Ø @ 0.25m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
6 TIE BEAM (TB) DETAIL
1. WHERE COLUMNS CHANGE IN SIZE, VERTICAL REINFORCEMENTS SHALL BE OFFSET AT A SLOPE NOT MORE THAN 1 IN 6. PROVIDE S-01 Scale: 1:20
TRANSVERSE REINFORCEMENT (JOINT HOOPS) AS PER FIGURE PROVIDED IN SHEET NO. 2. 0.305m 12Ø @ 0.23m O.C. E.F. 12Ø @ 0.27m O.C. E.F. - DO -
2. LAP SPLICES, WHEN REQUIRED, ARE PERMITTED ONLY WITHIN THE CENTER HALF OF TEH COLUMN LENGHT AND SHALL BE PROPORTIONED
AS TENSION SPLICES. IN NO CASE SHALL THE LAP SPLICE BE LOCATED CLOSER THAT A DISTANCE EQUAL TO THE MAXIMUM COLUMN 0.356m 12Ø @ 0.20m O.C. E.F. 12Ø @ 0.25m O.C. E.F. - DO -
DIMENSION FROM THE FACE OF THE BEAM-COLUMN JOINT. PROVIDE EXTRA TRANSVERSE REINFORCEMENT OF THE SAME SIZE ARRANGEMENT
0.406m 12Ø @ 0.25m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
INDICATED IN THE COLUMN SCHEDULE SPACED AT MOST ONE-FOURTH OF THE MINIMUM COLUMN DIMENSION THROUGHOUT THE LENGHT
OF THE SPLICE OR 100mm.
3. FOR ALL TIED COLUMNS, PROVIDE TRANSVERSE REINFORCEMENTS OF THE SAME SIZE AND ARRANGEMENT INDICATED IN THE COLUMN
SECTION SCHEDULE AND SPACED NO GREATER THAN ONE QUARTER THE MINIMUM COLUMN SECTION DIMENSION NOR 100mm. OVER A
DISTANCE FROM EACH JOINT FACE OF LESS NOT LESS THAN THE LARGER OF THE MAXIMUM COLUMN SECTION DIMENSION, OR ONE SIXTH
OF THE CLEAR HEIGHT OF THE COLUMN OR 450mm.
4. UNLESS OTHERWISE DETAILED, TYPICAL BAR DETAILS FOR TIED COLUMNS ARE AS SHOWN IN FIGURE PROVIDED IN SHEET. NO. 2.
1 STRUCTURAL NOTES
S-01 Scale: NTS
S-1
01
15
0
10 MMØ NOSING BARS
10 MMØ TEMP. BAR 10 MMØ TEMP.
PLACE AS SHOWN 200 BAR @ 220MM O.C.
10 MMØ @ 12 MMØ @ 175MM O.C.
200MM O.C.
100
TOP & BOT. MAIN
600
E.F. REBARS TYP.
12 MMØ @ 200MM O.C. E.F.
300
4-12 MMØ 12 MM Ø @ 200MM O.C. TO ALL
CONTINUOUS 600 STAIRS
10 MMØ NOSING BARS
15 0
12 MM Ø @ 175 VERIFY
MM O.C. TOP &
150
BOT. MAIN
REBARS TYP. TO
ALL STAIRS
12 MMØ @ 175 MM O.C. B.W. TOP &
150
BOT. LANDING REBARS
150
10 MMØ NOSING BARS
12 MM Ø @ 175 MM
10 MMØ TEMP. BAR @ O.C. B.W. TOP & BOT.
220 MM O.C. LANDING REBARS
150
TYP. STAIR FLR LVL DETAIL
Scale: NTS
200 L/4
STAIRWELL
125
125
EDGE OF SLAB
300
S-2
01
A B C D A B C D A B C D
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
S-3
01
PANEL NAME: LPP
LOCATION: GROUND FLOOR (LIVING ROOM)
RATING VOLTS AMPERES PROTECTION
CKT # LOAD DESCRIPTION L.O C.O SIZE OF WIRE CONDUIT
HP WATTS AT AF POLE
1 LIGHTING FIXTURES 8 800 230 3.48 15 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
2 CONVENIENCE OUTLET 7 1260 230 5.48 20 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
3 ACU-1HP 746 230 3.24 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
4 WASHING MACHINE 1000 230 4.35 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
3-WIRES 230 V. 60HZ. 1Ø
5 REFRIGERATOR 800 230 3.48 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
6 RANGE 3000 230 13.04 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
TOTAL 7606 33.07
COMPUTATION : (33.07+(0.25X13.04)) 0.8 D.F = 29.064 AMP USE: 2 # 30mm² THHN WIRE +
MCB : 40AT/40AF,2PCB,230V. 60HZ 1 # 8mm² THHN WIRE (G)
USE : 2 # 22mm² THHN WIRE + 1 # 8mm² THHN WIRE (G)
IN : 40mmØ IMC IN 50mmØ IMC
LPP
M M 100A
PANEL NAME: LPP
2P
LOCATION: SECOND FLOOR (LIVING ROOM) 2ND FL
LPP
RATING VOLTS AMPERES PROTECTION MCB, 2P, 100AT, 100A 40A MCB, 2P, 40AT, 40A
CKT # LOAD DESCRIPTION L.O C.O SIZE OF WIRE CONDUIT
HP WATTS AT AF POLE 230V, NEMA BOX 230V, NEMA BOX
2 SCHEDULE OF LOADS LO 1
ACU 3
2 CO
4 WM
E-01 Scale: NTS
REF 5 6 RANGE
1200
300
POWER
SERVICE DROP
50mmØ CONDUIT
1200
M:100AT
2PCB
8 - 16mm Ø VERT. BARS 230V
CLAMP
LO 1 2 LO
5200
4 - 16 mm Ø TOP &
ECB, AS REQ'D.
NEMA 3R ENCL.
BOT. BARS B.W. CO 3 4 CO
1200 (MIN.)
REF REFRIGERATOR C.O. W 3-PRONGS FRONT LOAD WASHER C.O RANGE 13 14 SPARE
WH WATER HEATER C.O. D 3-PRONGS FRONT LOAD DRYER C.O 150mm THK.
COMPACTED
HD HAIR DRYER C.O. ACU AIR CONDITION UNIT C.O
300
GRAVEL BASE
WPM WATER PUMP MOTOR C.O. 4-16Ø TOP &
LPP LIGHTING AND POWER PANEL BOARD BOT. BARS B.W. AS REQ'D. (TO PNL 'P')
DETAIL SECTION
1 GENERAL NOTES & LEGENDS 3 CONCRETE PEDESTAL DETAIL 5 POWER RISER DIAGRAM
E-01 Scale: NTS E-01 Scale: NTS E-01 Scale: NTS
E-1
01
6250 6250 6250 6250
2850
3 ACU 10 WH
11 HD
1425
1425
SINGLE SWITCH S
1425
1425
(T&B LIGHT)
kitchen sink
1 2
SINGLE SWITCH
WM
4 S
(KITCHEN SINK
LIGHT)
3000
5 REF 8 C.O 12 REF
S
SINGLE SWITCH
LAUNDRY LIGHT
REF ACU REF
KITCHEN SINK COUNTER C.O C.O SINGLE SWITCH
BEDROOM LIGHT
S
RANGE
4700
kitchen OVEN
6 R
COUNTER
13 R
3300
3300
kitchen
3300
C.O
3300
RANGE
4 C.O C.O
C.O
COUNTER
3 GANG SWITCH
(CENTER LIGHT, PIN LIGHT
& COVE LIGHT)
S
S
2 GANG SWITCH
CENTER LIGHT
2 C.O
S SINGLE SWITCH
& COVE LIGHT
LPP
LPP LPP MASTER'S BEDROOM
C.O 2 GANG SWITCH
LIGHT
KITCHEN &
T&B LIGHT
S
3700
LPP
C.O
C.O
S
12000
12000
2100
12000
2 GANG SWITCH
12000
C.O CENTER LIGHT
& COVE LIGHT
2700
C.O
3626
3625
3625
3626
C.O
TV
ACU
RACK
3
SINGLE SWITCH LAUNDRY LIGHT
C.O LIVING ROOM LIGHT S
ACU S
9 S
2 GANG SWITCH
BALCONY LIGHT
Sliding Door
1450
CENTER LIGHT
S
& PIN LIGHTS
WP 3 GANG SWITCH
- CANOPY PIN LIGHTS
- EAVES PIN LIGHT
1125
900
1100
- 3 WAY SWITCH
D 6 FLOOR
4750
2125
DRAIN
3650
S
3650
3650
C.O
3000
2450
Path Walk
Floor
Sink
3 GANG SWITCH
Main Gate with Service Door - OUTDOOR WALL LAMP
- CARPORT LIGHT
S - 3 WAY SWITCH
STAIRS LIGHT
Entrance Gate
Rump Up
800
2375 700
2475
E-2
01
GENERAL NOTES MATERIAL SPECIFICATION
*PLAN
1 CLEANOUT DETAIL
P-01 Scale: NTS
0.30m
*SECTION
0.40M
0.40M 0.40M
0.08M
0.50M
0.40M
0.10M
PLUMBING LEGEND AND SYMBOLS PLAN SECTION SECTION B
FINISHED WALL
38 mmØ VENT
LAVATORY
0.15
ESCUTCHEON PLATES VARIES
CONCRETE
NOTE WALL VARIES
1. MOUNTING DIMENSIONS SHALL BE VERIFIED BASED ON
13 mmØCOLD WATER
MANUFACTURER'S RECOMMENDATIONS.
900 mm
COLD WATER CLOSET & PIPE SIZE)
VARIES
SUPPLY (SEE SEE PLANS
METALLIC PLANS FOR COLD WATER
FOR CONT.
CONTINUATION SUPPLY (SEE
VARIES
PIPE SLEEVE
VARIES
VARIES
AND PIPE SIZE) PLANS FOR
FIN. FLOOR LINE
VARIES
P-TRAP CONTINUATION
AND PIPE SIZE)
CLEANOUT
VENT PIPE
P-1
01
IN
E WR
6250 RL "C
6250 E en s
ink 1/2
AT kitch ∅
RW
" PP
625 1/2
GE
RANOVEN
2175 3450 ∅ en R
kitchOUNTE
2175 3450 C
625 REF
3800 2050 LPP
2850 en R
kitch UNTE
CO
1425
kitchen sink ∅ L
RW
T V ACK PP
R "
oor 1/2
∅1/2" CWR ∅1/2" CWR Slid
ing D ∅
∅1/2" PPR WL
3000
oor r
REF en D FlooSink
REF
KITCHEN SINK COUNTER Scre
RANGE
4700
kitchen OVEN
COUNTER
TAP TO EXISTING WATER LINE kitchen
3300
3300
RANGE COUNTER
OR
FLODRAIN
WR
/2 "C
3700
∅1
12000
12000
2100
12000
L
RW
2700
PP E E
LIN
IN
3626
3625
" RL
TV
∅ 1/2 REF
TE
R TE
RACK A WA
GW
TER
OUN PR
KC
HEN
SIN
T IN "P
3/4
KITC
XI S ∅
E
O
PT WR
Sliding Door TA "C 6250
1/2 STER
1450
GE
RAN
∅ O P
BOPUM
LPP
WM
1125
900
Screen Door
∅1/2" CWR ∅1/2" CWR W E 2175 3450
FLOOR
NE IN
4750 RL 625
2125
DRAIN
BOOSTER TE
WA
∅1/2" PPR WL
PUMP N
r I
3650
3650
Doo A
Service M 4525
with
Gate OM
3000
Main
FR
2450
Path Walk
p Up
Rum
675
NEW WM Floor
Walk
1425
Sink Path
Rump Up
FROM MAIN WATER LINE
800
2375 700
3300
2475
8326
P-02 Scale: 1:100 P-02 Scale: 1:100 P-02 Scale: 1:100
12000
TR
SV
3625
6250 6250
ink
en s
kitch
625 SP
2175 3450 2175 3450 SP 2" Ø GE
RANOVEN
625 4" Ø en R
kitch UNTE
3800 2050 TR " Ø REF SS CO
SV 4
LPP
650
2850
en R
kitch UNTE
CO
3650
650
CB
4" Ø SP
2849
1425
1425
2450
650
2" Ø SP
SVTR SVTR
T V ACK
4" Ø SS R
550
3000
kitchen OVEN
COUNTER
kitchen
3300
3300
LPP
LPP
3700
P-02
4" Ø DP
Scale: 1:100
12000
12000
2100
12000
2700
SS
4" Ø
3626
3625
TV TR
RACK SV P
S REF
DP 2" ØTER
3" Ø KC
OUN
SIN
CB HEN
KITC
4" Ø DP SP
Sliding Door 4" Ø
1450
GE
RAN
3" Ø DP DP
3" Ø
1125
900
Screen Door
EXISTING FLOOR LPP
ING
4750
DP
2125
SEPTIC DRAIN
DP
4" Ø X IST PTICK
E SE AN
TANK IN INE
4" Ø
T MA E L
3650
3650
CB Doo
r TO INAG
A
3000
rvice
with
Se
DR
2450
UpM
AIN LINE
Floor
Sink TRumOp WER
CB Walk SE
Main Gate with Service Door Path
MA E L
TO MAIN Rump UpTO MAIN TO MAIN TO INAG
800 A
DRAINAGE LINE SEWER LINE DRAINAGE LINE DR
2375 700
2475
P-2
01