Sabang Dasma Complete Plans

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

GENERAL: CONCRETE SLAB:

1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED MODIFY TYPICAL DETAILS 1. ALL REINFORCEMENT SHALL BE .019M CLEAR MINIMUM FROM TOP AND BOTTOM OF SLAB.
AS DIRECTED TO MEET SPECIAL CONDITIONS. 2. FOR TWO-WAY SLAB ALONG THE LONGER SPAN SHALL BE PLACED BELOW BARS NEAR THE SUPPORT UNLESS OTHERWISE INDICATED OR
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS. MISCELLANEOUS IRON, PRE-CAST CONCRETE, DETAILING
SHOWN IN DETAILS THE SPACING OF THE BARS AT THE COLUMN STRIPS CAN BE APPROXIMATELY 131 OF THE MIDDLE STRIP IN NO CASE HOOK (A OR G) L
ETC. SHALL BE SUBMITTED FOR ENGINEER'S APPROVAL PRIOR TO PURCHASE, FABRICATION AND INSTALLATION. DIMENSION
GREATER THAN 231 TIMES THE SLAB THICKNESS.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN. CHECK WITH SANITARY, MECHANICAL AND ELECTRICAL 3. UNLESS OTHERWISE DETAILED IN CONDITIONING SLAB HAVING SAME REINFORCEMENT RUNNING IN ONE DIRECTION, REINFORCING SHALL
CONTRACTORS FOR CONDUITS, PIPE SLEEVES, ETC., TO BE EMBEDDED IN CONCRETE.

d
BEND, EXTENDED OR CUT AS FOLLOWS:
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING AND BRACING OF THE STRUCTURE FOR ALL LOADS 4. TEMPERATURE BARS FOR SLAB SHAL BE GENERALLY PLACED NEAR THE TENSION FACE AND SHALL NOT BE LESS THAN 0.025 BT.
THAT MAYBE IMPOSED DURING CONSTRUCTION.

J
5. UNLESS OTHERWISE NOTED, ALL BEDDED SLAB BE REINFORCED WITH 10mmØ BAR AT .25M O.C. B.W. AT CENTER OF SLAB. CONSTRUCTION D

JOINT FOR SLAB SHALL NOT BE MORE THAN 3.00M APART.

EMBEDMENT
FOOTING: L1/4
6. PROVIDE EXTRA REINFORCEMENT L1/4
AT CORNERL2/4 L2/4 DISCONTINOUS
SLAB (TWO ADJACENT L3/4 L3/4
EDGE) AS SHOWN BELOW.
4d OR 65 MM MIN DEPTH
1. FOOTINGS WERE DESIGNED TO REST ON SOIL WITH AN ASSUMED BEARING CAPACITY OF 5000psf.

0.30MIN
2. NO FOOTING SHALL REST ON FILL.

WIDTH
180 DEG

t
3. MINIMUM CONCRETE PROTECTION SHALL BE .075M CLEAR FOR CONCRETE DEPOSITED AGAINST THE GROUND AND 0.05M FOR

W
CONCRETE DEPOSITED AGAINST THE FRAMEWORK.
DETAILING

DEPTH
DIMENSION
CONCRETE MIXES AND PLACINGS:
1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDER COMPRESSIVE STRENGHT OF CONCRETE ARE AS FOLLOWS: L1/5 L1/5 L2/5 L2/5 L3/5 L3/5
L1 SPAN
EXTERIOR L2 SPAN
INTERIOR L3 SPAN
INTERIOR .
CANTILEVER

A OR G
LOCATION STREGHT AGGREGATE SIZE MAX. SLUMP
D

FOUNDATION, PILE CAP 3000 psi 3 4 IN (100mm)

12d
4 IN (19mm) REINFORCING STEEL BARS
BEAMS, GIRDERS 3000 psi 3
4 IN (19mm) 4 IN (100mm)
1. ALL REINFORCING STEEL SHALL BE NEW BILLET, HOT ROLLED, WELDABLE, DEFORMED BARS CONFORMING
COLUMN, STAIR 3000 psi 3 4 IN (100mm)
SUSPENDED SLAB 3000 psi
4
3
IN (19mm)
IN (19mm) 4 IN (100mm)
TO THE SPECIFICATIONS OF PNS 49; 1986 (ASTM 615), Fy= 60,000 psi (413.79 Mpa) FOR SIZES >12 AND
Fy = 40,000 psi (275.86 Mpa) FOR SIZES ≤12.
90 DEG
2 TYPICAL COLUMN FOOTING DETAIL
4 2. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, AND SPACED S-01 Scale: 1:30
SHEARWALL/RET. WALL 3000 psi 3
4 IN (19mm) 4 IN (100mm) IN FORMS, SECURED IN THE REQUIRED LOCATION IN ACCORDANCE WITH THE PROCEDURES AND
REQUIREMENTS OUTLINED IN THE LATEST EDITION OF THE BUILDING CODE AND THE MANUAL OF STANDARD STANDARD HOOKS
SLAB ON GRADE 2500 psi 3
IN (19mm) 4 IN (100mm)
4 PRACTICE FOR DETAILED REINFORCED CONCRETE STRUCTURES.
CL
2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED ACCORDING TO THE ACI STANDARDS.
3. ALL REINFORCING STEEL BARS SHALL BE THOUROUGHLY CLEANED OF ALL LOOSE RUST, SOIL OR OTHER
CORROSIVE MATERIAL IMMEDIATELY PRIOR TO PLACING OF CONCRETE.
C
L
VERIFY
3. STRIPPING OF FORMS AND SHORES SHALL BE AS FOLLOWS: 12d FOR 25 MM CL
6d FOR 10, 12, 16 MM
DEVELOPMENT LENGTH, (Ld), IN TENSION FOR RC BEAMS LENGTH OF LAP COMPRESSION SPLICES (mm)

A OR G
FOUNDATION 1 DAY

HOOK
AND GIRDERS (PRISMATIC OR NON-PRISMATIC) BAR SIZE RC WALL
BEAMS, GIRDERS 21 DAYS fc'=21MPa fc'=28MPa fc'=34.5MPa
fc'=21MPa (3000psi) fc'=28MPa (4000psi) fc'=34.5MPa(5000psi) (mm) (3000psi) (4000psi) (5000psi)
COLUMN & WALLS 3 DAYS BAR SIZE
(mm) TOP BARS BOT BARS TOP BARS BOT BARS TOP BARS BOT BARS CHB WALL INTERIOR CHB
SUSPENDED SLAB 17 DAYS 16Ø 420 390 360

DETAILING DIMENSION
(mm) (mm) (mm) (mm) (mm) (mm) D

SHEARWALL/RET. WALL 3 DAYS 20Ø 540 510 450


16Ø 730 560 630 480 560 430
25Ø 720 600 540
RC STAIRS 17 DAYS
20Ø 1090 840 940 730 840 650 10Ø TRANSVERSE
28Ø 810 720 690 J
25Ø 1820 1400 1570 1210 1410 1080 U-BARS @ 300 O.C.
4. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, RE-HANDLING, OR 4. 32Ø 900 780 720
FLOWING. PLACING OF CONCRETE SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS, OR WHEEL 28Ø 2340 1800 1980 1520 1765 1360
36Ø 990 900 810
BARROWS. NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUGGIES, D

TENSION LENGTH
32Ø 2990 2300 2600 1985 2300 1780
WHELL BARROWS, OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED 6.0M IN AGGREGATE LENGHT.
NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS, UNLESS 36Ø 3770 2900 3280 2520 2930 2250

100
AUTHORIZED IN WRITING BY THE DESIGNERS AND ONLY FOR USUAL CONDITIONS WHERE VIBRATOR IS

600 (MINIMUM)
TENSION SPLICE CLASSIFICATION:
EXTREMELY DIFFICULT TO ACCOMPLISH. REFER TO DWG. NO. S-01
CLASS A = 1.00Ld 90 DEG 10Ø TRANSVERSE BARS
FOR NOTES ON PREPARATION @ 300 O.C.
CLASS B = 1.33Ld OF SOIL SUB-BASE.

100
BEAMS AND GIRDERS:

DETAILING DIMENSIONA OR G
MASONRY AND CONCRETE BLOCKS:

HOOK

200
3-10Ø LONGITUDINAL BARS REFER TO DWG. NO. S-01
1. UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AT LEAST 6mm FOR 1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF. FOR LOAD BEARING TYPE TIE BEAM FOR NOTES ON PREPARATION
CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGHT OF 6.90 Mpa SHALL BE DEVELOPED. (CONT.) WITH TENSION SPLICE
EVERY 3.0M OF SPAN EXCECPT FOR CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED IN THE OF SOIL SUB-BASE.

6D
PLANS OR AS ORDERED BY THE STRUCTURAL ENGINEER BUT IN NO CASE LESS THAN 19mm FOR EVERY 3.0M 2. PROVIDE 1-16Ø VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS AND EACH SIDE OF MASONRY WALL OPENING.
100 500 100 300
OF FREE SPAN. 3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200mm) ON EACH SIDE OF MASONRY WALL OPENING.

H
4. UNLESS OTHERWISE INDICATED IN THE PLANS, WALL REINFORCEMENT SHALL BE AS FOLLOWS: REFER TO DWG. NO. S-01
2. IF THERE ARE TWO OR MORE LAYERS OF LONGITUDINAL REINFORCING BARS IN A BEAM OR ORDER, USE D

REFER TO DWG. NO. S-01 FOR NOTES ON PREPARATION 3-10Ø LONGITUDINAL BARS
SEPERATORS OF A SIZE NOT LESS THAN 25mm BARS SPACED ABOUT 0.90M ON CENTER. IN NO CASE SHALL FOR NOTES ON PREPARATION OF SOIL SUB-BASE.
THERE LESS THAN TWO (2) SEPERATORS BETWEEN LAYERS OF BARS. CONCRETE HOLLOW BLOCKS REINFORCEMENT (CONTINUOUS) WITH TENSION SPLICE
OF SOIL SUB-BASE.
3. LONGITUDINAL REINFORCING BARFS SHALL BE PLACED SYMMETRICALLY ABOUT THE VERTICAL CENTER
D

DET. OF CHB ON SLAB THICKENING


LINE OF THE BEAM OR GIRDER SECTION WHERE POSSIBLE WITH UPPER LAYER BARS PLACED DIRECTLY REINFORCEMENT NOTES
DET. OF CHB ON TIE BEAM DETAIL OF WALL FOOTING
ABOVE THOSE IN THE BOTTOM LAYER. t (mm)
HORIZONTAL VERTICAL
A.MIN. LAP SPLICE = 0.25M (FOR INTERIOR WALL)
4. MINIMUM CONCRETE PROTECTION OF REINFORCING BARS SHALL BE 38mm, B. PROVIDE RIGHT ANGLE REINFORCEMENT AT CORNER (FOR EXTERIOR WALL)
5. BEAM REINFORCING BARS BOTH TOP AND BOTTOM TERMINATING IN A WALL SHALL EXTEND AT THE MOST 75 10Ø @ 0.60m O.C. 10Ø @ 0.60m O.C. 0.90M LONG. 135 DEG
50mm FROM THE FAR FACE OF THE WALL AND SHALL TERMINATE IN A STANDARD 90° HOOK. C. WHERE CHB WALLS ADJOINING COLUMN, R.C. BEAM,
100 10Ø @ 0.60m O.C. 10Ø @ 0.60m O.C.
6. BEAM REINFORCING BARS BOT TOP AND BOTTOM TERMINATING IN A COLUMN, SHALL EXTERND TO THE WALL DOWEL W/ SAME SIZE AS VERTICAL OR HORIZONTAL STIRRUP AND TIE-HOOKS
FAR FACE OF THE CONFINED CONCRETE CORE OF THE COLUMN AND TERMINATED BY A STANDARD 90°
150 10Ø @ 0.60m O.C. 10Ø @ 0.60m O.C.
REINFORCEMENT SHALL BE PROVIDED. 3 WALL FOOTING DETAILS
HOOK. S-01 Scale: 1:20
7. GENERALLY NO LAP SLPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS AT POINTS WHERE CRITICAL 200 10Ø @ 0.60m O.C. 10Ø @ 0.60m O.C.
BENDING STRESSES OCCUR. IN ADDITION, FOR GIRDERS, NO LAP SPLICE SHALL BE LOCATED WITHIN THE
JOINTS OR WITHIN THE DISTANCE EQUAL TO TWICE THE DEPTH OF THE MEMBER FROM THE FACE OF THE
JOINT.
8. PROVIDE LAP SPLICES ON GIRDER WITH HOOP REINFORCEMENT OVER THE LENGHT OF THE LAPPED BARS CONCRETE WALLS:
SPACED NO FARTHER THAN ONE-FOURTH OF THE NOMINAL DEPTH OR 100mm. UNLESS OTHERWISED INDICATED IN THE PLANS, WALL REINFORCEMENT
9. SEE MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ALL SUSPENDED PIPE SHALL BE FOLLOWED ACCORDING TO THE FOLLOWING SCHEDULE
AND EMBEODED PIPINGS, CONDUITS, DUCTWORKS, ETC.
REINFORCEMENT
WALL VERTICAL
STANDARD HOOKS STIRRUP AND TIE-HOOKS THK. REMARKS SECTION

D
HORIZONTAL VERTICAL
180 DEG 90 DEG 90 DEG 135 DEG

VAR.
D D HOR. & CENTER VERT.
BAR SIZE BAR SIZE 0.102m 10Ø @ 0.25m O.C. 10Ø @ 0.30m O.C.
(MM) A OR G J A OR G (MM) A OR G A OR G H BARS STAGGERED OUTSIDE
B

VAR.
10Ø 60 125 60 150 10Ø 40 105 105 65 0.127m 10Ø @ 0.20m O.C. 10Ø @ 0.25m O.C. - DO -
12Ø 80 150 105 200 12Ø 50 115 115 80 12Ø @ 0.25m O.C. BOTH FACES HOR.
0.152m 12Ø @ 0.30m O.C. SHALL BE INSIDE
16Ø 95 175 130 250
0.178m 12Ø @ 0.23m O.C. 12Ø @ 0.25m O.C. - DO -

D
20Ø 125 225 175 350
12Ø @ 0.30m O.C. BOTH FACES HOR.
0.208m 12Ø @ 0.30m E.F.
25Ø
32Ø
155
275
275
425
205
335
425
550 0.229m 12Ø @ 0.20m O.C. 12Ø @ 0.25m O.C. E.F.
SHALL BE OUTSIDE
- DO -
7 DETAIL OF SLAB ON FILL / GRADE
S-01 Scale: 1:10
0.254m 12Ø @ 0.30m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
COLUMN: 0.275m 12Ø @ 0.25m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
6 TIE BEAM (TB) DETAIL
1. WHERE COLUMNS CHANGE IN SIZE, VERTICAL REINFORCEMENTS SHALL BE OFFSET AT A SLOPE NOT MORE THAN 1 IN 6. PROVIDE S-01 Scale: 1:20
TRANSVERSE REINFORCEMENT (JOINT HOOPS) AS PER FIGURE PROVIDED IN SHEET NO. 2. 0.305m 12Ø @ 0.23m O.C. E.F. 12Ø @ 0.27m O.C. E.F. - DO -
2. LAP SPLICES, WHEN REQUIRED, ARE PERMITTED ONLY WITHIN THE CENTER HALF OF TEH COLUMN LENGHT AND SHALL BE PROPORTIONED
AS TENSION SPLICES. IN NO CASE SHALL THE LAP SPLICE BE LOCATED CLOSER THAT A DISTANCE EQUAL TO THE MAXIMUM COLUMN 0.356m 12Ø @ 0.20m O.C. E.F. 12Ø @ 0.25m O.C. E.F. - DO -
DIMENSION FROM THE FACE OF THE BEAM-COLUMN JOINT. PROVIDE EXTRA TRANSVERSE REINFORCEMENT OF THE SAME SIZE ARRANGEMENT
0.406m 12Ø @ 0.25m O.C. E.F. 12Ø @ 0.30m O.C. E.F. - DO -
INDICATED IN THE COLUMN SCHEDULE SPACED AT MOST ONE-FOURTH OF THE MINIMUM COLUMN DIMENSION THROUGHOUT THE LENGHT
OF THE SPLICE OR 100mm.
3. FOR ALL TIED COLUMNS, PROVIDE TRANSVERSE REINFORCEMENTS OF THE SAME SIZE AND ARRANGEMENT INDICATED IN THE COLUMN
SECTION SCHEDULE AND SPACED NO GREATER THAN ONE QUARTER THE MINIMUM COLUMN SECTION DIMENSION NOR 100mm. OVER A
DISTANCE FROM EACH JOINT FACE OF LESS NOT LESS THAN THE LARGER OF THE MAXIMUM COLUMN SECTION DIMENSION, OR ONE SIXTH
OF THE CLEAR HEIGHT OF THE COLUMN OR 450mm.
4. UNLESS OTHERWISE DETAILED, TYPICAL BAR DETAILS FOR TIED COLUMNS ARE AS SHOWN IN FIGURE PROVIDED IN SHEET. NO. 2.

1 STRUCTURAL NOTES
S-01 Scale: NTS

8 TYPICAL BEAM DETAIL


S-01 Scale: NTS

S-1
01
 

15
0
10 MMØ NOSING BARS
10 MMØ TEMP. BAR 10 MMØ TEMP.
PLACE AS SHOWN 200 BAR @ 220MM O.C.
10 MMØ @ 12 MMØ @ 175MM O.C.
200MM O.C.

100
TOP & BOT. MAIN

600
E.F. REBARS TYP.
 
12 MMØ @ 200MM O.C. E.F.

300
4-12 MMØ 12 MM Ø @ 200MM O.C. TO ALL
CONTINUOUS 600 STAIRS

TYP. STAIR FOUNDATION DETAIL


Scale: NTS


10 MMØ NOSING BARS

15 0
 12 MM Ø @ 175 VERIFY
MM O.C. TOP &

150
BOT. MAIN
REBARS TYP. TO
ALL STAIRS
12 MMØ @ 175 MM O.C. B.W. TOP &

150
BOT. LANDING REBARS

TYP. STAIR LANDING DETAIL


Scale: NTS
 
SEE SUSPENDED SLAB SCHED.

150
10 MMØ NOSING BARS
12 MM Ø @ 175 MM
10 MMØ TEMP. BAR @ O.C. B.W. TOP & BOT.
220 MM O.C. LANDING REBARS

150
TYP. STAIR FLR LVL DETAIL
Scale: NTS

  




200 L/4

10MM DOWEL/TEMP. BAR SPACED WELDED WIRE


300 MM O.C. MESH

STAIRWELL
125

125
EDGE OF SLAB
300

MIN. 0.05 END LAP WELDED TO #12 TEKSCREW SPACED @


BEAM STIRRUP 0.30M O.C 2-12MMØ W/ 8 MM STIRRUPS
GRD. 80 STEEL DECKING GRD. 80 STEEL DECKING
SPACED @ 0.20M O.C.
WELDED WIRE
MESH

STEEL DECK SLAB DETAIL STEEL DECK SLAB DETAIL


@ SUPPORTED END @ FREE END/ STAIRS

S-2
01
A B C D A B C D A B C D

1 1 1

2 2 2

3 3 3

4 4 4

5 5 5

SECOND FLOOR ROOF

1 FOUNDATION PLAN 2 FRAMING PLAN 3 FRAMING PLAN


S-03 Scale: 1:100 S-03 Scale: 1:100 S-03 Scale: 1:100

S-3
01
PANEL NAME: LPP
LOCATION: GROUND FLOOR (LIVING ROOM)
RATING VOLTS AMPERES PROTECTION
CKT # LOAD DESCRIPTION L.O C.O SIZE OF WIRE CONDUIT
HP WATTS AT AF POLE
1 LIGHTING FIXTURES 8 800 230 3.48 15 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
2 CONVENIENCE OUTLET 7 1260 230 5.48 20 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
3 ACU-1HP 746 230 3.24 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
4 WASHING MACHINE 1000 230 4.35 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
3-WIRES 230 V. 60HZ. 1Ø
5 REFRIGERATOR 800 230 3.48 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
6 RANGE 3000 230 13.04 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
TOTAL 7606 33.07
COMPUTATION : (33.07+(0.25X13.04)) 0.8 D.F = 29.064 AMP USE: 2 # 30mm² THHN WIRE +
MCB : 40AT/40AF,2PCB,230V. 60HZ 1 # 8mm² THHN WIRE (G)
USE : 2 # 22mm² THHN WIRE + 1 # 8mm² THHN WIRE (G)
IN : 40mmØ IMC IN 50mmØ IMC

LPP
M M 100A
PANEL NAME: LPP
2P
LOCATION: SECOND FLOOR (LIVING ROOM) 2ND FL
LPP
RATING VOLTS AMPERES PROTECTION MCB, 2P, 100AT, 100A 40A MCB, 2P, 40AT, 40A
CKT # LOAD DESCRIPTION L.O C.O SIZE OF WIRE CONDUIT
HP WATTS AT AF POLE 230V, NEMA BOX 230V, NEMA BOX

1 LIGHTING FIXTURES 5 15 50 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ 2P 2P 2P


500 230 2.17 2
2 # 22mm² THHN WIRE 2 # 30mm² THHN WIRE
2 LIGHTING FIXTURES 20 2000 230 8.70 15 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ +1 # 8mm² THHN WIRE (G) +1 # 8mm² THHN WIRE (G)
3 CONVENIENCE OUTLET 2 360 230 1.57 20 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ IN 40mmØ PVC IN 50mmØ PVC
NGL
4 CONVENIENCE OUTLET 12 2160 230 9.39 20 50 2 2#3.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
5 WASHER 1300 230 5.65 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
6 DRYER 3000 230 13.04 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
7
8
WATERPUMP MOTOR
ACU-1HP
1500
746
230
230
6.52
3.24
30
30
50
50
2
2
2#5.5mm²+ 1#3.5mm² THNN WIRE
2#5.5mm²+ 1#3.5mm² THNN WIRE
20mmØ
20mmØ 4 SINGLE LINE DIAGRAM
E-01 Scale: NTS
9 ACU-1HP 746 230 3.24 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
10 WATER HEATER 1125 230 4.89 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
11 HAIR DRYER 2000 230 8.70 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
12 REFRIGERATOR 800 230 3.48 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
13 RANGE 3000 230 13.04 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
14 SPARE 1000 230 4.35 30 50 2 2#5.5mm²+ 1#3.5mm² THNN WIRE 20mmØ
TOTAL 20237 87.99
COMPUTATION : (87.99+(0.25X13.04)) 0.8 D.F = 73.00 AMP 40mmØ CONDUIT
MCB : 100AT/100AF,2PCB,230V. 60HZ
USE : 2 # 30mm² THHN WIRE + 1 # 8mm² THHN WIRE (G) M:40AT
IN : 50mmØ IMC 2PCB
230V

2 SCHEDULE OF LOADS LO 1

ACU 3
2 CO

4 WM
E-01 Scale: NTS
REF 5 6 RANGE

1200

300
POWER
SERVICE DROP

50mmØ CONDUIT

1200
M:100AT
2PCB
8 - 16mm Ø VERT. BARS 230V
CLAMP

LO 1 2 LO

5200
4 - 16 mm Ø TOP &
ECB, AS REQ'D.
NEMA 3R ENCL.
BOT. BARS B.W. CO 3 4 CO

POWER CONDUIT, DETAIL PLAN WASHER 5 6 DRYER


AS REQ'D.
10 mm Ø TIES @ 300mm
WPM 7 8 ACU
LEGEND SIDEWALK
PROPOSED GRADE LINE
ACU 9 10 WH
FLOOR LINE
WM WASHING MACHINE C.O. R 3-PRONGS RANGE OVEN C.O HD 11 12 REF

1200 (MIN.)
REF REFRIGERATOR C.O. W 3-PRONGS FRONT LOAD WASHER C.O RANGE 13 14 SPARE
WH WATER HEATER C.O. D 3-PRONGS FRONT LOAD DRYER C.O 150mm THK.
COMPACTED
HD HAIR DRYER C.O. ACU AIR CONDITION UNIT C.O

300
GRAVEL BASE
WPM WATER PUMP MOTOR C.O. 4-16Ø TOP &
LPP LIGHTING AND POWER PANEL BOARD BOT. BARS B.W. AS REQ'D. (TO PNL 'P')

DETAIL SECTION

1 GENERAL NOTES & LEGENDS 3 CONCRETE PEDESTAL DETAIL 5 POWER RISER DIAGRAM
E-01 Scale: NTS E-01 Scale: NTS E-01 Scale: NTS

E-1
01
6250 6250 6250 6250

625 625 625


2175 3450 2175 3450 2175 3450 2175 3450
625
3800 2050

2850

3 ACU 10 WH
11 HD
1425

1425
SINGLE SWITCH S

1425
1425
(T&B LIGHT)
kitchen sink
1 2
SINGLE SWITCH
WM
4 S
(KITCHEN SINK
LIGHT)

3000
5 REF 8 C.O 12 REF
S
SINGLE SWITCH
LAUNDRY LIGHT
REF ACU REF
KITCHEN SINK COUNTER C.O C.O SINGLE SWITCH
BEDROOM LIGHT
S
RANGE
4700

kitchen OVEN
6 R
COUNTER
13 R
3300

3300
kitchen

3300
C.O

3300
RANGE
4 C.O C.O
C.O
COUNTER
3 GANG SWITCH
(CENTER LIGHT, PIN LIGHT
& COVE LIGHT)
S

S
2 GANG SWITCH
CENTER LIGHT

2 C.O
S SINGLE SWITCH
& COVE LIGHT

LPP
LPP LPP MASTER'S BEDROOM
C.O 2 GANG SWITCH
LIGHT

KITCHEN &
T&B LIGHT
S

3700
LPP
C.O
C.O
S
12000

12000
2100

12000
2 GANG SWITCH

12000
C.O CENTER LIGHT
& COVE LIGHT
2700

C.O
3626

3625

3625
3626
C.O
TV
ACU
RACK

C.O SINGLE SWITCH

3
SINGLE SWITCH LAUNDRY LIGHT
C.O LIVING ROOM LIGHT S

ACU S

9 S

WP C.O C.O C.O 2 GANG SWITCH


PORCH LIGHT & OUTDOOR
WALL LAMP
1 SINGLE SWITCH
S

2 GANG SWITCH
BALCONY LIGHT
Sliding Door
1450

CENTER LIGHT
S
& PIN LIGHTS

WP 3 GANG SWITCH
- CANOPY PIN LIGHTS
- EAVES PIN LIGHT

1125

900

1100
- 3 WAY SWITCH

5 W Screen Door STAIRS LIGHT

D 6 FLOOR
4750

2125
DRAIN

7 WPM SINGLE SWITCH


STORE LIGHT
3650

3650
S

3650
3650
C.O
3000

2450
Path Walk

Floor
Sink
3 GANG SWITCH
Main Gate with Service Door - OUTDOOR WALL LAMP
- CARPORT LIGHT
S - 3 WAY SWITCH
STAIRS LIGHT

Entrance Gate

Rump Up
800
2375 700

2475

GROUND FLOOR SECOND GROUND FLOOR SECOND FLOOR

1 POWER LAYOUT 2 POWER LAYOUT 3 LIGHTING LAYOUT 4 LIGHTING LAYOUT


E-02 Scale: 1:100 E-02 Scale: 1:100 E-02 Scale: 1:100 E-02 Scale: 1:100

E-2
01
GENERAL NOTES MATERIAL SPECIFICATION

*PLAN

1 CLEANOUT DETAIL
P-01 Scale: NTS

0.30m
*SECTION

2 WATER METER DETAIL SEPTIC VAULT


SEPTIC TANKDETAIL
DETAIL
P-01 Scale: NTS 3
P-01 Scale: NTS

0.40M
0.40M 0.40M

0.08M
0.50M
0.40M

0.10M
PLUMBING LEGEND AND SYMBOLS PLAN SECTION SECTION B

STORM DRAINAGE SYSTEM 4 CATCH BASIN DETAIL


WATER DISTRIBUTION SYSTEM P-01 Scale: NTS

FINISHED WALL

38 mmØ VENT
LAVATORY

0.15
ESCUTCHEON PLATES VARIES
CONCRETE
NOTE WALL VARIES
1. MOUNTING DIMENSIONS SHALL BE VERIFIED BASED ON
13 mmØCOLD WATER
MANUFACTURER'S RECOMMENDATIONS.

WASTE, SEWER & VENT SYSTEM


PIPE LINE
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
ISOLATING OTHERWISE INDICATED.
VALVE
CONCRETE VENT PIPE
WALL CONCRETE WALL
(SEE PLANS
WESTERN WATER
WESTERN WATER FOR CONT. CLOSET

900 mm
COLD WATER CLOSET & PIPE SIZE)

VARIES
SUPPLY (SEE SEE PLANS
METALLIC PLANS FOR COLD WATER
FOR CONT.
CONTINUATION SUPPLY (SEE

VARIES
PIPE SLEEVE

VARIES

VARIES
AND PIPE SIZE) PLANS FOR
FIN. FLOOR LINE

VARIES
P-TRAP CONTINUATION
AND PIPE SIZE)
CLEANOUT
VENT PIPE

PLUMBING FIXTURES WATER SUPPLY


CMU WALL
50 mmØ
DRAIN LINE (SEE PLANS
FOR CONT.
& PIPE SIZE)
CWS PIPE SLEEVE (TYP)
100 SEE PLANS
50 VENT FOR CONT.
FINISH FLOOR LINE
NOTE:

5 MANHOLE COVER DETAIL 1. MOUNTING DIMENSIONS SHALL BE VERIFIED BASED ON


MANUFACTURER'S RECOMMENDATIONS. PLAN SECTION
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
P-01 Scale: NTS OTHERWISE INDICATED.,

6 TYPICAL LAVATORY INSTALLATION DETAIL 7 WATER CLOSET (FLUSH TANK)


P-01 Scale: NTS P-01 Scale: NTS

P-1
01
IN
E WR
6250 RL "C
6250 E en s
ink 1/2
AT kitch ∅
RW
" PP
625 1/2
GE
RANOVEN
2175 3450 ∅ en R
kitchOUNTE
2175 3450 C
625 REF
3800 2050 LPP

2850 en R
kitch UNTE
CO

∅1/2" PPR WATER LINE


WR
"C
1/2
1425

1425
kitchen sink ∅ L
RW
T V ACK PP
R "
oor 1/2
∅1/2" CWR ∅1/2" CWR Slid
ing D ∅
∅1/2" PPR WL

3000
oor r
REF en D FlooSink
REF
KITCHEN SINK COUNTER Scre

RANGE
4700

kitchen OVEN
COUNTER
TAP TO EXISTING WATER LINE kitchen
3300

3300
RANGE COUNTER
OR
FLODRAIN

∅3/4" PPR WATER LINE


LPP
LPP

WR
/2 "C

3700
∅1
12000

12000
2100

12000
L
RW
2700

PP E E
LIN
IN
3626

3625
" RL
TV
∅ 1/2 REF
TE
R TE
RACK A WA
GW
TER
OUN PR
KC
HEN
SIN
T IN "P
3/4
KITC
XI S ∅
E
O
PT WR
Sliding Door TA "C 6250
1/2 STER
1450

GE
RAN
∅ O P
BOPUM
LPP
WM

1125

900
Screen Door
∅1/2" CWR ∅1/2" CWR W E 2175 3450
FLOOR
NE IN
4750 RL 625

2125
DRAIN
BOOSTER TE
WA

∅1/2" PPR WL
PUMP N
r I
3650

3650
Doo A
Service M 4525
with
Gate OM
3000

Main
FR

2450
Path Walk
p Up
Rum

675
NEW WM Floor
Walk

1425
Sink Path

Main Gate with Service Door


Gate
ance
Entr
Entrance Gate

Rump Up
FROM MAIN WATER LINE
800
2375 700

3300
2475

GROUND FLOOR SECOND FLOOR ISOMETRIC DIAGRAM

1 WATERLINE LAYOUT 2 WATERLINE LAYOUT 3 WATERLINE LAYOUT

8326
P-02 Scale: 1:100 P-02 Scale: 1:100 P-02 Scale: 1:100

12000
TR
SV

3625
6250 6250
ink
en s
kitch
625 SP
2175 3450 2175 3450 SP 2" Ø GE
RANOVEN
625 4" Ø en R
kitch UNTE
3800 2050 TR " Ø REF SS CO
SV 4
LPP

650
2850
en R
kitch UNTE
CO

3650

650
CB

4" Ø SP

2849
1425

1425

3" Ø DP kitchen sink

2450

650
2" Ø SP
SVTR SVTR
T V ACK
4" Ø SS R

550
3000

2" Ø SP 4" Ø SS ing D


oor
REF REF Slid
KITCHEN SINK COUNTER
oor r
en D FlooSink
RANGE Scre
4700

kitchen OVEN
COUNTER
kitchen
3300

3300

RANGE 650 650


COUNTER 650 650 650 650 650
OR
FLODRAIN
ROOF 4750

LPP
LPP

7 STORM DRAINAGE PLAN


4" Ø SP

3700

P-02
4" Ø DP

Scale: 1:100
12000

12000
2100

12000
2700

SS
4" Ø
3626

3625

TV TR
RACK SV P
S REF
DP 2" ØTER
3" Ø KC
OUN
SIN
CB HEN
KITC
4" Ø DP SP
Sliding Door 4" Ø
1450

GE
RAN
3" Ø DP DP
3" Ø
1125

900

Screen Door
EXISTING FLOOR LPP
ING
4750

DP
2125

SEPTIC DRAIN
DP
4" Ø X IST PTICK
E SE AN
TANK IN INE
4" Ø
T MA E L
3650

3650

CB Doo
r TO INAG
A
3000

rvice
with
Se
DR
2450

Path Walk Gate


Main

UpM
AIN LINE
Floor
Sink TRumOp WER
CB Walk SE
Main Gate with Service Door Path

Entrance Gate Gate


nce
IN INE
a
Entr

MA E L
TO MAIN Rump UpTO MAIN TO MAIN TO INAG
800 A
DRAINAGE LINE SEWER LINE DRAINAGE LINE DR
2375 700

2475

GROUND FLOOR SECOND FLOOR ISOMETRIC DIAGRAM

4 SEWERLINE LAYOUT 5 SEWERLINE LAYOUT 6 SEWERLINE LAYOUT


P-02 Scale: 1:100 P-02 Scale: 1:100 P-02 Scale: 1:100

P-2
01