Professional Documents
Culture Documents
D 8 Acoustics - Job Specification (D10-PMC-JSF-011)
D 8 Acoustics - Job Specification (D10-PMC-JSF-011)
D 8 Acoustics - Job Specification (D10-PMC-JSF-011)
INDIAN OIL
TECHNOLOGY DEVELOPMENT & DEPLOYMENT CENTER
FARIDABAD (HARYANA)
Submission
Rev. No. Description Prepared By Reviewed By Approved By
Date
Page 1 of 6
INDIAN OIL
TECHNOLOGY DEVELOPMENT & DEPLOYMENT CENTER
JOB SPECIFICATION - ACOUSTICS
Table of Contents
1. PERFORATED CEILING SYSTEM (GYPSUM BOARD) ..........................................................................3
5. CARPET .....................................................................................................................................................4
Page 2 of 6
INDIAN OIL
TECHNOLOGY DEVELOPMENT & DEPLOYMENT CENTER
JOB SPECIFICATION - ACOUSTICS
Acoustic performance
Absorption NRC: In the range of 0.65 - 0.8 (with 25mm acoustic insulation layer)
Perforation hole size – 3 mm or higher (round, square or slot as per design) with at least 11% perforated
area
Location
It is used in offices, lab, Individual offices, meeting room, conference room, library, lobby, multipurpose
halls and Indoor games room.
Acoustic performance
NRC: In the range of 0.6 - 0.7
Location
It is used in offices, lab, Individual offices, meeting room, conference room, library, lobby, multipurpose
halls and Indoor games room.
Acoustic performance
NRC ≥ 0.65 (Thickness: 50mm)
Location
Hung on wall surfaces for good acoustic absorption requirements. It is used in Individual offices, meeting
room, conference room and multipurpose halls.
Size
As per design requirement.
Acoustic performance
NRC ≥ 0.65
Location
As decorative, acoustically effective wall coverings for use indoors and in covered outside areas that are
not exposed to weather such as rain or environmental pollution. It can be used in laboratory rooms,
meeting room, library and entrance lobby.
Page 3 of 6
INDIAN OIL
TECHNOLOGY DEVELOPMENT & DEPLOYMENT CENTER
JOB SPECIFICATION - ACOUSTICS
5. CARPET
Composition: 80% wool, 20% polyamide. Back on jute and knitted cotton finished w/ resin. Layer over leveled flat
concrete floor.
Acoustic performance
NRC ≥ 0.35
Thickness – 10mm or higher
Location
It is used in meeting room, conference room, multipurpose hall and indoor games room.
6. ACOUSTIC INSULATION
Mineral wool is used as a filling between partition wall and behind perforated MDF, gypsum board or fabric panel
for acoustic absorption. A minimum of 48kg/m3 density mineral wool should be used for optimum performance.
Acoustic performance
Absorption - NRC = 0.8-0.9 (50mm thick)
Isolation
o STC = 10dB and higher (50MM thick, 48kg/m3)
o STC = 15dB and higher (50MM thick, 80kg/m3)
o STC = 17dB and higher (50MM thick, 100kg/m3)
Location
For all partition wall system and behind fabric, grooved MDF board and perforated gypsum board ceiling
panels.
7. GYPSUM BOARD
Laminated gypsum board of thickness 12.5mm with a material density of 640 kg/m3 or higher should be used for
used for internal partition wall for all the rooms.
Acoustic performance
Isolation: STC = 26dB and higher
Size = (1.2x2.4 sq m) based on vendor availability
Location
For all partition wall system and false ceilings.
Acoustic performance
Impact Isolation: IIC = 50 with 150mm thick concrete slab of 2100kg/m3 density.
Location
To be installed in multipurpose halls, indoor games room and gym.
Page 4 of 6
INDIAN OIL
TECHNOLOGY DEVELOPMENT & DEPLOYMENT CENTER
JOB SPECIFICATION - ACOUSTICS
Acoustic performance
Absorption NRC: 0.7-0.9 for 25mm thick
Location
All HVAC ducting basis insertion loss required.
Acoustic performance
Sound Isolation: STC 63 with overall thickness of 350 mm and double layer of gypsum board with an
airgap of 100 mm between concrete block and gypsum board.
Location
AHU / Mechanical / Electrical equipment rooms
Acoustic performance
o Sound Isolation: STC = 50 dB with overall minimum thickness of 90mm filled with mineral wool of
100kg/m3 or higher density / Metal finish door
o Sound Isolation: STC = 45 dB with overall minimum thickness of 75mm filled with mineral wool of
80kg/m3 or higher density / Metal or Timber finish door
o Sound Isolation: STC = 40 dB with overall minimum thickness of 65mm filled with mineral wool of
80kg/m3 or higher density / Timber finish door
o Sound Isolation: STC = 35 dB with overall minimum thickness of 50mm filled with mineral wool of
80 kg/m3 or higher density / Timber finish door
Location
o AHU/ Mechanical equipment rooms – STC 50
o Toilets and Locker rooms – STC 45
o Multipurpose Halls and Labs – STC 40
o Office and all other spaces - STC 35
Page 5 of 6