DRAWING No. Sheet No. ISSUE MODIFICATIONS:'A'-FIRST ISSUE Ref. Part No. Drawing or Legacy Part No. Description Materials Q.ty Spares
1 87009809 *B67820-388 ROTARY INSERT SiC 1
GA-162522 1 A
2 89008935 00002433201 O-RING FFKM 1 X
INCLUDING:
FI = FLUSH INLET CONN. Ø 3/4" NPT 5 87009682 0900/K04/198 ANTI-EXTRUSION CAP GLASS FILLED PTFE 2
56.5 149 6 89008935 00002433201 O-RING FFKM 1 X
A
Q = QUENCH (PLUGGED) CONN.Ø 3/8" NPT 7 89009224 00003453201 O-RING FFKM 1 X
D = DRAIN (PLUGGED) CONN.Ø 3/8" NPT 10 87000736 *B18129-182 SPRING ASTM B637 UNS N07750 8
98
FO 11 87090473 *B73931-152 CIRCLIP ASTM A313 UNS S30200 1
A HEAT EXCHANGER 1
15 16 17 17 14 11 12 4B 4A 4 9 7 22 29 25 26 28
140 H7
79 h6
208
180
O
O
O
O
19 18 13 2 5 1 3 5 6 10 8 20 29 21 23 24 27
VIEW 'A'
FO API / ISO SEAL CODE PIPING PLAN
SEAL DATA
BSAIN 1CW-FL 23/61
SEAL IDENTIFIER (INBOARD / OUTBOARD) 0900 / RREP / X76 F55 1 X76 O95 O65
/ /
CUSTOMER CONTRACTOR
CUSTOMER DATA
KSB F oster Wheeler Energy Ltd
END USER EQUIPMENT TYPE
GS E&C / NSRP LLC OH Centrifugal Pump
SITE LOCATION OEM
NGHI Son Refinery, Vietnam KSB
PLANT MODEL / SIZE
070 RPH C6 250-501D
PLANT ITEM No.
FI 070-P-102 A/B/C/D
D
2 2 .5 °
20°
112
Q
22 .5
°
°
45
BARRIER / BUFFER FLUID NAME BARRIER / BUFFER PRESSURE BARRIER / BUFFER TEMPERATURE
D R A
EXTRACTION HOLES
2 x M10
D
4 x M16 - THE SETTING WASHERS REF. 26 ARE USED ONLY TO PRESET THE CORRECT OPERATING LENGTH
OF THE SEAL WHEN ASSEMBLED INTO A CARTRIDGE. THEY MUST BE DISENGAGED AFTER COMPLETING
SCALE
1:1
DATE
03/07/2014
DRAWN
DG
CHK'D
DG
APP'D
MS
DRG. LOCATION DESIGN AUTH.
IT01EN IT01EN
N
I V 15
- 2 0
Only those parts itemised are supplied by John Crane Italia
O
17-N BUILT
THE INSTALLATION AND BEFORE STARTING THE EQUIPMENT
All intellectual property rights (including but not limited to copyright and design rights whether registered or unregistered) in relation to this drawing together with the information contained in this drawing (including but not limited to know-how and confidential information)
DRAWING No.
GA-162522
Sheet No. ISSUE
1 B
AS
are proprietary to John Crane. Reproduction (whether in whole or in part) or use in any way whatsoever of this drawing or of any information contained therein is prohibited except with the prior written consent of John Crane. All rights in relation to this drawing are reserved .
A1
Category 1 & 2 Seals REQUIRED FOR: SITE: UNIT:
MECHANICAL SEAL DATA SHEET JOB/PROJECT NO. 14-00115 ITEM NO. 070-P-102 A/B/C/D
FOR CENTRIFUGAL & ROTARY PUMPS REQUISITION / SPEC. NUMBER /
S.I. UNITS INQUIRY NUMBER BY
PAGE 1 OF 2 PURCH ORDER NUMBER DATE
REVISION NO. 3 DATE
1 DATA SUPPLIED CUSTOMARY UNITS SI UNITS HARDWARE SUPPLIED CUSTOMARY UNITS SI UNITS
2 INDICATES DATA COMPLETED BY PURCHASER BY SEAL VENDOR BY SEAL VENDOR OR PURCHASER
3 DEFAULT SELECTION
4 SEAL SPECIFICATION - (REF CLAUSE 4.1, FIGURES 1 TO 6.1)
5 CATEGORY SEAL CATEGORY 1 (4.1.1) SEAL CATEGORY 2 (4.1.1) SEAL CODE (ANNEX J)
6 TYPE TYPE A (3.72) TYPE B (3.73) ALTERNATE STATIONARY (TYPE A & B)
7 (CODE-CW) TYPE C (3.74) ALTERNATE ROTATING (TYPE C) SINGLE SPRING (TYPE A)
8 ARR'G'T DEFAULT CONFIGURATION ALTERNATE DESIGN FLUSH PLANS (SEE ANNEX D)
9 1 (3.2) 1CW-FX 1CW-FL DIST. FLUSH 01 11 14 23 32 51 62
10 ALTERNATE BUSH 02 13 21 31 41 61 65
2CW-CW
BARRIER BUFFER
Note 1: at start up
relative density 1
Viscosity 1.569 cP
D R A
N
I 17-NO UILT15
V - 2 0
AS B
Category 1 & 2 Seals REQUIRED FOR: SITE: UNIT:
MECHANICAL SEAL DATA SHEET JOB/PROJECT NO. ITEM NO. 070-P-102 A/B/C/D
FOR CENTRIFUGAL & ROTARY PUMPS REQUISITION / SPEC. NUMBER /
S.I. UNITS INQUIRY NUMBER BY
PAGE 2 OF 2 PURCHASE ORDER NUMBER DATE
(FLUID DATA, UTILITIES, ACCESSORIES, & INSP./TEST.) REVISION NO. 3 DATE
1 INDICATES DATA COMPLETED BY PURCHASER BY SEAL VENDOR BY SEAL VENDOR OR PURCHASER
2 DEFAULT SELECTION
3 FLUID DATA - (QUENCH, BUFFER AND BARRIER FLUID DATA, LIQUID AND GAS)
4 QUENCH MEDIUM (PLAN 51, 62) SUPPLY TEMPERATURE MAX/MIN / °C
5 TYPE OR NAME FLOW RATE REQ'D MAX/MIN / kg/h
6 BUFFER/BARRIER MEDIUM
7 TYPE OR NAME RELATIVE DENSITY (TO WATER @ 25°C) AT REF. TEMP.
8 PURCHASER SELEC'N SEAL VENDOR SELEC'N @ NORMAL TEMP @ MAX TEMP
9 SEAL VENDOR REVIEW PURCHASER REVIEW ABSOLUTE VAPOR PRESSURE AT REFERENCE TEMP.
10 FLOW RATE REQ'D MAX/MIN. / l/min NORMAL TEMP bar MAX TEMP bar
11 COOLING/HEATING REQUIRED (+ OR -) kW ATMOSPHERIC BOILING POINT (LIQUID) °C
12 SUPPLY PRESSURE MAX/MIN. / bar (ga) VISCOSITY @ NORMAL TEMP (LIQUID) Pa.s
13 FLUID OPERATING TEMPERATURE SPECIFIC HEAT CAPACITY @ CONSTANT PRESSURE
14 MIN °C NORMAL °C MAX °C FOR LIQUID @ NORMAL TEMPERATURE J/Kg.K
15 SITE AND UTILITIES
3
16 CONTROL VOLTAGE 690 V PHASE 3 HERTZ 50 COOLING H2O SUPPLY TEMP. 34 °C Cl2 NIL ml/m
17 ELECTRICAL AREA ZONE 2, IIC T3 COOLING H2O PRESS. NORM./DES. 5,35 / 10 bar (g)
18 DESIGN AMBIENT MIN./MAX. 3 / 42,4 °C ATEX (EC DIRECTIVE 94/9/EC) ZONE 2, IIC T3
19 ACCESSORIES (CLAUSES 8 AND 9)
20 GENERAL PLAN 52 AND 53 SYSTEMS CONTINUED
21 JOINT USER/VENDOR LAYOUT OF EQUIPMENT (8.1.4) EQUIPMENT SUPPORT SUPPLIER
22 PIPE TAPER THREADS (8.1.9) ISO 7 ASME B1.20.1 FILLING SYSTEM SUPPLIER
23 SPECIAL REQUIREMENTS FOR HAZARDOUS SERVICE ASME CODE STAMP REQUIRED
24 EN 13445 OR OTHER CODE APPLICABLE
25 SPECIAL CLEANING AND DECONTAMINATION REQ'TS RESERVOIR CAPACITY (8.5.4.3) l
26 UTILITY MANIFOLD CONNECTIONS REQUIRED (8.4.4) NLL TO GLAND PLATE HEIGHT (8.5.4.2) m
27 TYPE AND SPEC. OF HEAT TRACING (8.6.5.8) RESERVOIR MAWP (3.39) bar (ga) @ °C
28 SET PRESSURE RANGE, MAX/MIN / bar (ga)
29 THERMAL RELIEF VALVES REQUIRED (9.8.3) SYSTEM HOLD-UP PERIOD (PLANS 53B & 53C) DAYS
30 COOLING SYSTEM (PLAN 21, 22, 23, 41, 53B, 53C) TEMPERATURE INDICATOR (PLAN 53B & 53C)
31 HEAT EXCHANGER SUPPLIER John Crane PRESSURE SWITCH (8.5.4.2.7) TO ACTIVATE ON;
32 WATER COOLED AIR COOLED ISO 15649 RISING PRESSURE (ARR 2) SET @ bar (ga)
33 EQUIPMENT REFERENCE/CODE TEMA C FALLING PRESSURE (ARR 3) SET @ bar (ga)
34 COOLING WATER LINES SUPPLIER Vendor HIGH LEVEL ALARM REQUIRED (8.5.4.2.8)
35 TUBING SS (8.4.2) TEST BASED H/Q CURVE FOR INTERNAL CIRC. DEVICE
36 COOLING WATER FLOW RATE 0,6 m3/h EXTERNAL CIRCULATING PUMP (8.6.3.1)
37 SIGHT FLOW INDICATORS (8.4.3) OPEN CLOSED PLAN 72 AND 74 SYSTEM
38 PLAN 11, 13, 14, 21, 23, 31, 32 AND 41 SYSTEMS EQUIPMENT SUPPLIER
39 CONNECTING LINES SUPPLIER VENDOR HIGH FLOW ALARM SWITCH (8.6.6.5)
40 TUBING PIPING (8.5.2.2) PLAN 75 AND 76 SYSTEM
41 RESTRICTION ORIFICE NIPPLE IN FLUSH LINE (8.5.2.4) EQUIPMENT SUPPLIER
42 CYCLONE SEPARATOR SUPPLIER HIGH LEVEL ALARM SWITCH FOR PLAN 75 (8.6.5.3)
43 PLAN 32 EQUIPMENT SUPPLIER TEST CONNECTION (8.6.5.4)
44 PLAN 32 FLOW IND'R PLAN 32 TEMPERATURE IND'R INSTRUMENTATION
45 PLAN 52 AND 53 SYSTEMS USER SPECIFICATION REFERENCE FOR
46 STANDARD (FIG D.27) ALTERNATE (FIG D.28) INSTRUMENTATION/CONTROLS Job Spec. S-000-1370-0002V