Ground Floor Lighting Layout 2Nd Floor Lighting Layout: A C D E F G B 1 A C D E F G B 1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A B C D E F G A B C D E F G

ELECTRIC SERVICE ENTRANCE


1 1 POWER TRANSFORMER

2 2
4 4
ELECTRIC METER
1 1

PANEL BOARD

n CIRCUIT BREAKER
5 5
n CIRCUIT HOME RUN

2 2 GROUND
3 3

3 200 LUMENS- 2 X 40 WATTS PANEL LIGHT

18 WATTS - 6 INCHES DIA. PIN LIGHT

AIR CONDITIONING UNIT

ACCU AIR COOLED CONDENSING UNIT

3 3 RO COOKING RANGE UNIT

REF REFRIGERATOR UNIT

CEILING MOUNTED ACU

EXHAUST FAN

SWITCH LINE

4 4 UNIVERSAL OUTLET (2 GANG)

n SWITCHn( GANG)

1 GROUND FLOOR LIGHTING LAYOUT 2 2ND FLOOR LIGHTING LAYOUT WALL MOUNTED WATERPROOF POWER LIGHT, 18 WATTS

E-1 TO SCALE 1:66.67 6-LIGHT CHANDELIER BULB , 60 WATTS


E-1 TO SCALE 1:66.67

A B C D E F G A B C D E F G GEN. ELECTRICAL NOTES & SPECS:


1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN
ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE,
1 1 THE RULES AND THE REGULATIONS OF THE LOCAL ENFORCING AUTHORITY,
AND THE REQUIREMENTS OT HE LOCAL POWER. ELECTRICAL WORKS SHALL
BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED ENGINEER OF
MASTER ELECTRICIAN.
2. ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN LOCATION AS FOLLOWS:
6 6 A. RIGID STEEL CONDUIT (RSC) TO BE USED IN SERVICE ENTRANCE AND
FEEDERS
B. ELECTRICAL METALLIC TUBING (EMT) TO BE USED ABOVE THE CEILING
AND BETWEEN DOUBLE WALLS MADE OF COMBUSTIBLE MATERIALS
C. POLYVINYL CHLORIDE CONDUIT (PVC) TO BE USED IF EMBEDDED IN
CONCRETE OR UNDERGROUND
3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN"
UNLESS OTHERWISE INDICATED. THE MINIMUM SIZE FOR POWER SHALL BE NO
3.5 MM. TW. CONTROL WIRES SHALL BE NO 2.0 MM TW ALL WIRES SHALL BE AS
2 2
n n 6 6
INDICATED OR AS SPECIFIED ELSEWHERE ON THE PLABS, PHELPS DODGE OR
DURAFLEX BRANDS SHALL BE USED.

4. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACUTAL LOCATION OF


SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY.

5. ALL PIPE SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR


ANCHORAGE NECESSARY FOR PERMANENT CONECTION TO CONCRETE WALLING
6 6 OR BEAM.
6. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANEL BOARD, LIGHTING
6 6 FIXTURES AND ALL NON-CURRENT CARRYING METAL PARTS SHALL BE
PROPERLY GROUNDED IN ACCORDANCE WITH THE PHILIPPINE ELECTRICAL
6 6 CODE.

7. ALL FEEDERS AND BRANCH CIRCUITS SHALL BE INSTALLED AS INDICATED IN THE


PLANS, BRANCH CIRCUIT HOMERUN WIRES SHALL BE INSTALLED INDIVIDUALLY.
3 3 ANY DISCREPANCY IN THE LOCATION AND RATINGS OF EQUIPMENTS AND
8.
APPARATUS SHALL BE VERIFIED WITH THE OWNER OR ANY OF HIS
REPRESENTATIVES AND CHANGES SHALL BE MADE ACCORDINGLY.

9. ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE BRAND


NEW AND MUST BE OF THE PROVED TYPES FOR THE PARTICULAR LOCATION.

10. FOR EACH BRANCH CIRCUIT IN THE PANEL BOARD PROVIDE ONE (1) 20mmØ
EMPTY RACEWAY TERMINATING AT A 100 mm OCTAGONAL JUNCTION BOX
ABOVE.
7 7 8 8
6 6 11. THE ELECTRICAL SERVICE POWER SHALL BE 1-PHASE, 3-WIRE, 230V AC, 60Hz.

4 4 12. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS:


a. LIGHT SWITCH - 1.20M ABOVE FINISH FLOOR
b. CONVENIENCE OUTLET - 0.3M ABOVE FINISH FLOOR

ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER.

3 GROUND FLOOR CONVENIENCE LAYOUT 4 2ND FLOOR CONVENIENCE LAYOUT


E-1 TO SCALE 1:66.67 E-1 TO SCALE 1:66.67

PROJECT & LOCATION SHEET CONTENTS: PREPARED BY SET NO: SHEET NO:
· GROUND FLOOR LIGHTING LAYOUT
UNIVERSITY OF SOUTHERN MINDANAO · 2ND FLOOR LIGHTING LAYOUT
KABACAN, NORTH COTABATO · GROUND FLOOR CONVENIENCE
Construction of 2-storey Residential Duplex Building LAYOUT
COLLEGE OF ENGINEERING AND
INFORMATION TECHNOLOGY Doroluman, Arakan, North Cotabato
·
·
·
2ND FLOOR CONVENIENCE LAYOUT
LEGEND
GENERAL ELECTRICAL NOTES AND
MON ADRIAN C. TUNGAO CHARLES STEPHEN M. YANSON
ENGINEER I
GABRIEL ANTONIO T. PAMAT
ENGINEER I ENGINEER I
E 1
SPECS
DATE: