Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DOCUMENT D

EMPLOYER’S REQUIREMENTS
APPENDICES “4N” – QUANTITIES OF MAJOR ITEMS

The Tenderer shall provide the quantities of for all major items as per his design along with the submission
of Tender.

Sl. No Description Type Unit Quantity


1 GROUND FLOOR - ATRIUM
1.1 Flooring
(a) 30 mm thick polished Bottacino marble stone Flooring m2
(b) 30 mm thick polished Armani brown marble stone Flooring m2
1.2 Column cladding
(a) 20mm thick Bottacino marble, polished finished stone cladding m2
1.3 Landscape planter box cladding
(a) 20mm thick Bottacino marble, polished finished stone cladding m2
2 GROUND FLOOR CORRIDOR
2.1 Ceiling
(a) 4mm thick Wooden Veneer false ceiling m2
2.2 Flooring
(a) 30 mm thick polished Bottacino marble stone Flooring m2
2.3 Wall Cladding
(a) 4mm thick Wooden Veneer wall panels m2
3 GROUND FLOOR PASSENGER LIFT LOBBY
3.1 Ceiling
(a) 12.5 mm thick Gypsum False Ceiling m2
3.2 Flooring
(a) 30 mm thick polished Bottacino marble stone Flooring m2
(b) 30 mm thick polished Armani brown marble stone Flooring m2
3.3 Wall cladding
(a) 20mm thick Grigio Fluer Stone m2
(b) Wooden Flutings m2
20mm thick Grigio Fluer Stone, polished Marble in Lift lobby
(c) m2
Jamb
4 GROUND FLOOR TRANSFER LIFT LOBBY
4.1 Ceiling
(a) 12.5 mm thick Gypsum False Ceiling m2
4.2 Flooring
(a) 30 mm thick polished Bottacino marble stone Flooring m2
4.3 Wall cladding
(a) 20mm thick Grigio Fluer Stone m2
(b) Wooden Flutings m2
20mm thick Grigio Fluer Stone, polished Marble in Lift lobby
(c) m2
Jambs
20mm thick Grigio Fluer Stone, honed finished stone Wall
(d) m2
cladding

Radial IT Park D/4/N/1


DOCUMENT D
EMPLOYER’S REQUIREMENTS
APPENDICES “4N” – QUANTITIES OF MAJOR ITEMS
Sl. No Description Type Unit Quantity
5 GROUND FLOOR ATRIUM & HANDICAP TOILETS
5.1 Flooring
(a) 15-20mm Anti-skid Vitrified Grey Williams Tile flooring m2
5.2 Wall Dado
(a) 15-20mm grey Williams Vitrified polished wall cladding tiles, m2
5.3 Countertops
(a) 15-20 mm thick Volakas stone Cladding m2
5.4 Ceiling
(a) 12.5 mm thick Moisture Resistant Gypsum board false ceiling m2
6 TYPICAL LIFT LOBBIES
6.1 Ceiling
(a) 12.5 mm thick Gypsum False Ceiling m2
6.2 Flooring
(a) 15-20mm Beige vitrified tile flooring m2
6.3 Wall Cladding
(a) 15-20mm grey Williams vitrified polished wall cladding tiles m2
(b) Grey Williams polished tiles for lift jamb m2
7 LIFT CAR
7.1 Ceiling
(a) SS hairline brushed metal finish sheet cladding m2
(b) Stretch fabric ceiling m2
7.2 Flooring
(a) 30 mm thick polished Bottacino marble stone Flooring m2
(b) 100 mm high SS skirting m
7.3 Wall Cladding
(a) Laminate panelling m2
(b) 5mm thick Mirror Panelling m2
(c) Metal handrail on wall SS m
8 LOOSE FURNITURES
(a) F1 - Feature Sofa No
(b) F2 - Armchair No
(c) F3 - Coffee Table No
(d) F4 -Sofa No
(e) F5 - Armchair No
(f) F6 - Coffee Table No
(g) F7 - Coffee Table No
(h) F8 - Console No
(j) F9 - High Chair No
(k) F10 - Task Table No

Radial IT Park D/4/N/2


DOCUMENT D
EMPLOYER’S REQUIREMENTS
APPENDICES “4N” – QUANTITIES OF MAJOR ITEMS
Sl. No Description Type Unit Quantity
(l) F11 - Chair No
(m) F12 - Discussion Table No
(n) F13 -Sofa No
(p) F14 - Armchair No
(q) F15 - Counter No
(r) F16 - High Chair No
(s) F17 -Café Chair No
(t) F18 -Café Table No
(u) F19 -Signature Table No
(v) R1 - Area Rug m2
9 SIGNAGES
Signage for all lift lobbies, transfer lobbies, Ground floor atrium
(a) No
space, GF corridor, Toilets and Typical floor lift lobbies
(b) Wall mounted way finding signages No
(c) Information signages No
(d) wing name signages No
(e) Wall mounted Digital Tenant directory No
(f) Floor mounted Digital Tenant directory No
10 SANITARY FIXTURES
(a) Water closet No
(b) Water closet sensor Flush Valves No
(c) Water closet - HC toilet No
(d) Urinals No
(e) Urinal’s sensor Flush Valves No
(f) Wash basin No
(g) Single Lever Basin Mixer with sensor No
(h) Health Faucet (HF) No
(j) Jumbo double roll Tissue Dispenser (TD) No
(k) Tissue Paper near Vanity Counter (TD1) No
(l) Grab Bar L Shape (GB) No
(m) Grab rail (GB) No
(n) Floor trap (FT) No
(p) Toilet Cubicle No
(q) Toilet Urinal Dividers No
(r) Mirrors for Wash basins No
(s) Soap dispenser (SD) No
(t) Hand dryer (HD) No
(u) Sanitary bin (SB) No
(v) Dust bin (DB) No

Radial IT Park D/4/N/3


DOCUMENT D
EMPLOYER’S REQUIREMENTS
APPENDICES “4N” – QUANTITIES OF MAJOR ITEMS
Sl. No Description Type Unit Quantity
(w) Coat hook (CH) No
(x) Feedback panel (FP) No
(y) Full length mirrors No
(z) Internal piping works m
11 LIGHT FIXTURES
(a) Flex Phobos white SV IP67 LED strips No
(b) Flex Hydra LD White LED strips No
(c) Flex Hydra White IP67 LED strips No
(d) PSU/Control, Feed-in / Wiring No
(e) 13.7 W square recessed down lighters No
(f) 9.9W adjustable recessed downlight No
9W adjustable recessed downlight - DOMO 160 SPOT G2 1500
(g) No
WW MFL WH
9W adjustable recessed downlight - DOMO 160 SPOT G2 1500
(h) No
WW FL WH
(j) 12W recessed column uplighters No
(k) 13.7 W down lighters No
(l) 12W square recessed down lighters Electronic Gear No
(m) 12W square recessed down lighters Adjustable Dali No
(n) 9.9 W down lighters No
(p) 15W Planter uplighters No
(q) 1W LED light boxes at green nodes No
(r) Surface mounted LED tube lights No
Pendant cylindrical light fixtures suspended from custom metal
(s) No
frame
(t) L2 - Task Floor Lamp No
(u) L3 -Task Integrated table Lamp No
12 MISCELLANEOUS
12.1 Trap doors for CSUs in false ceiling of lift lobbies No

Radial IT Park D/4/N/4

You might also like