Upehco Plan
Upehco Plan
SHEET 2 A-02
FRONT ELEVATION
LEFT SIDE ELEVATION
____________________________
RIGHT SIDE ELEVATION
REAR ELEVATION District / City / Municipality
SCHEDULE OF DOORS AND WINDOWS
SECTION THRU A
SECTION THRU B
SCHEDULE OF DOORS AND WINDOWS
TOILET DETAILS
LAND USE AND ZONING
SHEET 3 A-03 STAIR DETAILS
FOUNDATION PLAN
2ND FLOOR FRAMING PLAN
ROOF FRAMING PLAN
GENERAL NOTES
SHEET 4 S-01 BEAM DETAILS
LOT 24 BLK 7 WALL FOOTING DETAILS
COLUMN FOOTING DETAILS
DETAIL OF TYPICAL CONTINUOUS CONCRETE SLAB
DETAIL SECTION OF FLOOR SLAB
SLAB ISOMETRIC VIEW
TYPICAL SLAB DETAILS
LINE AND GRADE
LIGHTING LAYOUTS
POWER LAYOUTS
MATERIAL SPECIFICATIONS
SHEET 5 E-01 LEGEND AND SYMBOLS
SERVICE ENTRANCE DETAILS
LOAD COMPUTATION
LOAD SCHEDULE
PLUMBING LAYOUTS
WATER DISTRIBUTION LAYOUTS
ISOMETRIC DIAGRAM ARCHITECTURAL
SHEET 6 P-01
SPECIFICATIONS
LEGEND AND SYMBOLS
CIVIL / STRUCTURAL
ALLEY 1
MECHANICAL
SITE SITE
SANITARY
GENERAL NOTES:
1. CONTRACTOR TO VERIFY ALL SITE DIMENSIONS. PLUMBING
2. CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE
ARCHITECT IF CONFUSION ARISES ON SITE OR IF DIMENSIONS
AND/OR DETAILS ARE MISSING FROM THE DRAWING SET
BEFORE PROCEEEDING WITH WORK ON SITE.
LEB
A
OWNER REVISIONS:
01
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
BLOCK 7, LOT 24, UP EMPLOYEES HOUSING COOPERATIVE, INC. PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
BRGY SAN LUIS ANTIPOLO CITY
B B
A B C A B C
5000 5000
2400 2600 2400 2600 A B C
1400
1 1
1000
w 2400 2600
2 w FIREWALL
2200
3
BEDROOM 2 1
D
3450
D 2
2
2225
2 KITCHEN
A 2 BEDROOM 3 BEDROOM 4
5250
FIREWALL
FIREWALL
1250
D D D 2
T&B 3 4 4
3 8000
DINING AREA 3 A
6000
8000
D
3025
DN
1750 3 3
1800
TOILET
10000
D
2
4 UP
4 w w
D
2 LIVING AREA 1 4 4
2800
BEDROOM 1 BALCONY
D
1
w
w
1
3 ROOF PLAN
2
A-2 SCALE 1:100 MTS
5 w 5
3000
1
2000
300
300
w
w D 3 2ND FLR CEILING LINE (ELEV. 5.70) 2ND FLR CEILING LINE (ELEV. 5.70)
1 2
2700
2700
SECOND FLR FFL (ELEV. 3.00) SECOND FLR FFL (ELEV. 3.00)
300
300
2700
2700
GROUND FLR FFL (ELEV. 0.20) GROUND FLR FFL (ELEV. 0.20)
200
200
LEB
A
OWNER REVISIONS:
02
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
BLOCK 7, LOT 24, UP EMPLOYEES HOUSING COOPERATIVE, INC. PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
BRGY SAN LUIS ANTIPOLO CITY
300
BEDROOM
4 T&B
BEDROOM
BEDROOM T&B
4
2700
3
STAIRS
LIVING AREA
T&B KITCHEN
3 2 1
200
CONCRETE SLAB W/
1 SECTION THRU A 2 SECTION THRU B RUSTIC TILE BORDER
5
A-3 SCALE 1:100 MTS
A-3 SCALE 1:100 MTS
BLOW - UP DETAILS
6
16
15
7 14
13
8 12
11
10
9 9
A B 8
7
10
6
300mm x 300mm unGLAZED 5
3154 FLOOR TILES FINISH 4
11
3
2
D D D D 1
UP
1 2 4 3 12
2
NO. REQ'D: 1 SET NO. REQ'D: 2 SETS NO. REQ'D: 2 SETS NO. REQ'D: 2 SETS
1643
3
T&B
D
3 LIVING AREA
(PANEL DOOR)
BEDROOMS
(PANEL DOOR)
BEDROOMS
(PANEL DOOR)
T & B, LAUNDRY
(PVC FLUSH DOOR)
13 ELEVATION
14
TOILET PLAN
2400
850 1200 1250 15
CERAMIC TILES
2400
1800
W W W W
1 2 3 3
NO. REQ'D: 4 SETS
(SLIDING WINDOW)
NO. REQ'D: 1 SET
(SLIDING WINDOW)
NO. REQ'D: 1 SET
(AWNING WINDOW)
NO. REQ'D: 1 SET 5 STAIRS DETAILS
SCALE NTS
A-3
SECTION THRU 'A'
SECTION THRU 'B'
4 DOORS AND WINDOWS SCHEDULE
SCALE NTS
A-3
3 TOILET DETAILS
A-3 SCALE 1:100 MTS
LEB
A
OWNER REVISIONS:
03
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
BLOCK 7, LOT 24, UP EMPLOYEES HOUSING COOPERATIVE, INC. PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
BRGY SAN LUIS ANTIPOLO CITY
SCHEDULE OF BEAMS
C1F1 C1F1 B2 B2 FIREWALL
R E I N F O R C E M E N T S
DIMENSION SPACING OF STIRRUPS REMARKS
MARK
FTB1
LEFT SUPPORT MIDSPAN RIGHT SUPPORT ( 10 mm Ø )
B2
B2
S1 S1 WIDTH X THICKNESS MARK C-1
TOP BOTTOM TOP BOTTOM TOP BOTTOM
B2
FTB1
FTB-1 200 X 300 5-16 3-16 3-16 5-16 5-16 3-16 4 @ 0.10, 8 @ 0.15, REST @ 0.18 m. O.C. TO L PRISMATIC
FROM FOOTING TO
C1F2 C1F2
FIREWALL
FIREWALL
B1 B-1 200 X 300 5-16 3-16 3-16 5-16 5-16 3-16 4 @ 0.10, 8 @ 0.15, REST @ 0.18 m. O.C. TO L PRISMATIC
FIREWALL
ROOF BEAM
FIREWALL
FTB1
PRISMATIC
RB1 B-2
FIREWALL
200 X 300 3-16 3-16 3-16 3-16 3-16 3-16 4 @ 0.10, 8 @ 0.15, REST @ 0.18 m. O.C. TO L
FIREWALL
FTB1
400mm X 200mm
B2
FTB1 S1 RB-1 200 X 300 2-16 2-16 2-16 2-16 2-16 2-16 4 @ 0.10, 8 @ 0.15, REST @ 0.18 m. O.C. TO L PRISMATIC 8-16 mm Ø
SPAN
RSB W/ 10mm Ø
L
TIES: 2 @ 0.05m,
L/4 L/4 3 @ 0.10, 4 @ 0.15,
FTB1 REST @ 0.20 m.
B1 O.C. TO MID-HT
---
FTB1
FTB1 S1
B2
BEAM
B2
BOTTOM BARS, 5 - 16MMØ BEAM
900
700
L TIES: 2 @ 0.05m, 3 @ 0.10, 4 @ 0.15, TIES: 2 @ 0.05m, 3 @ 0.10, 4 @ 0.15,
REST @ 0.20 m. O.C. TO MID-HT REST @ 0.20 m. O.C. TO MID-HT
C1F2 C1F2 L/4 L/4
6-16mmØ RSB 6-16mmØ RSB
ON BOTHWAYS ON BOTHWAYS
300
300
TOP BARS, 4 - 16MMØ
TOP BARS, 3 - 16MMØ
100 MM THK GRAVEL BASE (G-1) 100 MM THK GRAVEL BASE (G-1)
BEAM B-2
BOTTOM BARS, 2 - 16MMØ
B-2 1200 1000
1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN USE 10MM Ø STIRRUPS SPACED AS FOLLOWS: 1@0.05M, 2@0.10M, 3@0.15M, REST @ 0.20M
SPAN 200 200
S-1 SCALE NTS L
S-1 SCALE NTS L/4 L/4 8-16 mm Ø RSB W/ 10mm Ø
TIES: 2 @ 0.05m, 3 @ 0.10, 4 @ 0.15,
400
REST @ 0.20 m. O.C. TO MID-HT
8-16 mm Ø RSB W/ 10mm Ø
1200
1000
TIES: 2 @ 0.05m, 3 @ 0.10, 4 @ 0.15,
400
TOP BARS, 2 - 13MMØ REST @ 0.20 m. O.C. TO MID-HT
TOP BARS, 2 - 16MMØ
TOP BARS, 2 - 12MMØ
1/4
S P LS LO
SPAN 1/4 N G
N SP
PA AN
L/4 12 Ø 12 Ø L/4 TS 1/2
OR LS
SH SP
2
12MM Ø BEND BARS
@ 0.20M O.C
12MM Ø BEND BARS
@ 0.20M O.C 1/
12MM Ø STRAIGHT BARS 12MM Ø STRAIGHT BARS
@ 0.20M O.C @ 0.20M O.C
WF-1 WF-2
1/4
12MM Ø CUT BARS 12MM Ø CUT BARS
SP LS
@ 0.20M O.C. @ 0.20M O.C.
4
1/
0.10
4 WALL FOOTING DETAILS 12MM Ø STRAIGHT BARS 12MM Ø STRAIGHT BARS @ 0.20M O.C.
(BENT-UP) ALTERNATE WITH
12MM Ø STRAIGHT BARS
1. USE f c' = 21MPa FOR ALL CONCRETE WORKS SPAN 10 MMØ CONTINUOUS RSB
2. USE fy = 275 MPa FOR 10,12,16 & 20 mmØ REINFORCING STEEL BARS L/4 12 Ø 12 Ø L/4 10 MMØ CUT RSB
415 MPa FOR 25mmØ REINFORCING STEEL BARS 12MM Ø BEND BARS 12MM Ø BEND BARS
4. PROVIDE FULL WELD CONNECTIONS FOR ALL STEEL SCHEDULE OF FOOTINGS B-2
0.10
SCHEDULE OF SLAB
10MM Ø STRAIGHT BARS 12MM Ø STRAIGHT BARS @ 0.20M O.C. 10MM Ø STRAIGHT BARS
@ 0.20M O.C (BENT-UP) ALTERNATE WITH @ 0.20M O.C
TRUSSES AND FRAMES ( STRUCTURAL WELD ). D I M E N S I O N ( mm ) STEEL REINFORCEMENT
10MM Ø REBARS ON BOTH WAYS
7. FOUNDATION MUST REST ON HARD SOIL STRATA F2 1000 1000 1000 300 6-16 mm Ø 6-16 mm Ø ISOLATED FIG. 8 DET. SECTION OF FLOOR SLAB S-1 100 12mmØ @ 200mm O.C. 12mmØ @ 200mm O.C. 10mmØ @ 400mm O.C.
S-1 SCALE NTS S-2 125 12mmØ @ 200mm O.C. 12mmØ @ 200mm O.C. 12mmØ @ 300mm O.C.
8. OBSERVED PROPER CONSTRUCTION METHODS.
CHECKED BY:
GAA
S
MR & MRS ROSE ANN Q. CORDOVA CIVIL ENGINEER
LEB
PROJECT LOCATION:
PROJECT NO.:
01-28-2024
01
TIN NO.:
BRGY SAN LUIS ANTIPOLO CITY
A B C A B C
5 LOAD SCHEDULE
SCALE NTS
E-1
5484 5484
2632 2852 2632 2852
1536
1 1 CKT L.O. C.O. REMARKS WATTS VOLTS AMP. WIRE DESCRIPTION BREAKER
1097
D
3 w
2
2413
BEDROOM 2 1 5 LIGHTING OUTLET 500 230 2.17 2-2.0mm², 1-2.0mm² in 15mmØ CONDUIT 20A
D
D 2
3784
2 KITCHEN
2 5 LIGHTING OUTLET 500 230 2.17 2-2.0mm², 1-2.0mm² in 15mmØ CONDUIT 20A
2 Ck
t 2 BEDROOM 3 BEDROOM 4
5758
1 3 7 LIGHTING OUTLET 700 230 3.04 2-2.0mm², 1-2.0mm² in 15mmØ CONDUIT 20A
1371
D D D
T&B 3 2 2
4 5 CONVENIENCE OUTLET 900 230 3.91 2-3.5mm², 1-2.0mm² in 15mmØ CONDUIT 30A
3 3
6581
8774
8775
DN D
DINING AREA 3 5 4 CONVENIENCE OUTLET 720 230 3.13 2-3.5mm², 1-2.0mm² in 15mmØ CONDUIT 30A
1919
1974
TOILET
10968
D
Ck 4 w w
2 2 t 1 Ck 3 7 REFRIGERATOR 600 230 2.61 2-3.5mm², 1-2.0mm² in 15mmØ CONDUIT 30A
3 t
LIVING AREA
8 RANGE 4000 230 17.39 2-5.5mm², 1-3.5mm² in 15mmØ CONDUIT 40A
3071
BEDROOM 1 D
1 BALCONY
w
9 SPARE 1500 230 6.52 2-5.5mm², 1-3.5mm² in 15mmØ CONDUIT 30A
D 1
3
10 SPARE 1500 230 6.52 2-5.5mm², 1-3.5mm² in 15mmØ CONDUIT 30A
5 w 5
3290
1
TOTAL : 12360 53.72
2194
6
LOAD COMPUTATION :
I = 12360 WATTS / 230 VOLTS = 53.72 AMPERES
GROUND FLOOR SECOND FLOOR T
I = 53.72 AMP X 80% DF
T
1 LIGHTING LAYOUT 2 LIGHTING LAYOUT I = 42.98AMP
T
E-1 SCALE 1:100 MTS E-1 SCALE 1:100 MTS
1.70 M.
USE: 60AT, 2P, 230V
WIRE SIZE: 2 - 14.0MM² THHN / 1 - 8.0 MM² TW IN 25 MMØ PVC
PROTECTION: 60AT / 60AF, 230 V, 60 HZ., BOLT-ON TYPE CIRCUIT
8 GENERAL SPECIFICATION
SCALE NTS
A B C A B C E-1
5274 5274
2 - 14.0MM² THHN / 1 - 8.0 MM²
TW IN 25 MMØ PVC 6 SERVICE ENTRANCE DETAILS
SCALE NTS
2531 2742 2531 2742 E-1
1477
1 1 60AT/60AF
1055
D
3 w C.O C.O 20AT 20AT
C.O
BEDROOM 2
2 L.O. L.O.
D Ck C.O C.O
D 2
3639
8 t 1 2
LEGEND
RANGE
C.O
2
9
2 KITCHEN 2 20AT 30AT NTS
L.O. C.O. SCALE
BEDROOM 3 BEDROOM 4 E-1
5538
Ck
D
7 t REF
D D C.O 3 4
T&B 3 C.O
2 2 C
kt
3 Ck 3 6 30AT 30AT
8438
6329
8438
1899
TOILET 5 6
DINING AREA
10548
D
2 30AT 40AT
4
UP C.O C.O C.O
REF RANGE
D
4 w w
2 1 3
C.O C.O
LIVING AREA 7 8
BEDROOM 1 C.O
2953
1
2110
6
1-8.0 mm² TW GROUNDING WIRE
GROUND FLOOR SECOND FLOOR W/ 21 X10 GROUNDING ROD
LEB
E
OWNER REVISIONS:
01
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
A B C
5000
2400 2600
A B C
1 5000
1000
2400 2600
2200
BEDROOM 2
1400
1 BE
KS DR
2 O OM
KITCHEN
1250
LAV 3
BT BE
WC
DN
DR
3450
O OM
T&B
3 DINING AREA 4
8000
6000
2 BEDROOM 4 TO
BEDROOM 3 LA ILE
5250
BA
1750
LC V T BE
ON WC DR
Y OO
10000
BT M
2
4 UP
3 T &WC
8000
DN TOILET B LA
LIVING AREA V
KIT
1800
LAV UP CH KS
DI E N
2800
BEDROOM 1 WC BE NI
DR NG
OO AR
4 M
1
LIV EA
ING
AR
EA
5 BALCONY
3000
2000
5 M
6 TO
MA
IN
M WA
TE
R LIN
ES
UP
PL
Y
SCALE NTS
P-1
A B C
BE
DR
5000 O OM
2400 2600 3
BE
DN
DR
O OM SS
4
1 A B C TO
1000
LA ILE
CO
BA V T
LC W
ON
2200
5000 FD C
BEDROOM 2 Y
SS SS
2400 2600
CO
KS 1400
2 CO
1
FD KITCHEN
1250
BT LAV
WC
T&B
3 SS BE
8000
6000
DINING AREA DR
3450
CO
OO
1750
BT M
2
2 T &WC
10000
BEDROOM 3 BEDROOM 4
5250
LA
B V FD
4 UP
KIT
UP CH K
LIVING AREA DIN EN S CO SS
3 BE ING
DR
8000
TOILET OO AR
2800
BEDROOM 1
DN
CB M LIV EA
1800
CO
LAV 1 ING
AR
WC EA
CB FD
4 SS TO CB
5 DR
AINTO M
MA
IN
3000
CB SE
AG AIN WE
EL RL
IN
2000
BALCONY E INE
6
6 SEWERLINE LAYOUT
SCALE NTS
5 P-1
TO MAIN SEWERLINE
TO MAIN
DRAINAGE LINE
SECOND FLOOR
GROUND FLOOR
4 SEWERLINE LAY OUT 7 ISOMETRIC DIAGRAM
SCALE NTS
P-1 P-1 SCALE NTS
3 SEWERLINE LAY OUT
SCALE NTS
P-1
LEB
P
OWNER REVISIONS:
01
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
BLOCK 7, LOT 24, UP EMPLOYEES HOUSING COOPERATIVE, INC. PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
BRGY SAN LUIS ANTIPOLO CITY
1 GENERAL NOTES CAP
HOUSE BIB BALL I. PL
SCALE NTS
P-2
AIR CHAMBER
FAUCET (SEE DETAIL)
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE
EXECUTED IN ACCORDANCE WITH THE PROVISIONS AIR CHAMBER (AC) WASTE OR SOIL PIPE
ANGLE STOP VALVE
OF THE PHILIPPINE PLUMBING CODE, THE NATIONAL 90 ELBOW
GSP PIPE RUBBER FLEXIBLE
BUILDING CODE AND THE RULES AND REGULATIONS LAV
OF THE MUNICIPALITY. 0.40 VALVE SOCKET WASTEWATER CLAMP (STAINLESS STEEL)
2. COORDINATE THE DRAWING WITH THE OTHER RELATED MALLEABLE IRON TREE 0.60 PIPE
DRAWINGS AND SPECIFICATIONS, THE ENGINEER SHALL VALVE SOCKET
BE NOTIFIED IMMEDIATELY OF ANY DESCRIPANCY FOUND WATER SUPPLY
WATER SUPPLY PIPE
HEREIN. TO FIXTURE CONCRETE
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS
ANY REVISION REQUIRED FOR PROPER EXECUTION OF PVC PIPE FLOOR
OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
ARCHITECT OR ENGINEER. FLOOR
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE FROM SUPPLY PIPE 0.10
SHOWER VALVE
FD FLOOR DRAIN VALVE SOCKET 2-12mm MALE FEMALE TEE CONNECTED 50mm X 50mm
WATER CLOSET FLANCE
CONCRETE TOPPING
CONC. SLAB
ADAPTER TO ANGLE VALVE
WC WATER CLOSET
KS KITCHEN SINK TO FIXTURE
WATER SUPPLY PIPE
PIPE SLEEVE
PVC elbow 90 x 100mm
LAV LAVATORY BT BATH TUB
PIPE HANGER EMBEDED TO SLAB OR
USE EXPANSION SLOT
SCALE NTS
P-2
150 920 150 1840 150
3200 FAUCET
GSP FITTING
POLISHED BRONZE
FINISH
150
150
300
FLOW
PLAN
FINISHED
FLOOR LINE
2300
2000
2650
FLOOR
300
LEB
P
OWNER REVISIONS:
02
PROJECT LOCATION: PRC NO.: ISSUED ON: DATE:
01-28-2024
BLOCK 7, LOT 24, UP EMPLOYEES HOUSING COOPERATIVE, INC. PTR NO.: ISSUED AT:
TIN NO.: PROJECT NO.:
BRGY SAN LUIS ANTIPOLO CITY