Professional Documents
Culture Documents
941 Series Relay: 941 Referential Data Timing
941 Series Relay: 941 Referential Data Timing
FEATURES
● UL safety approval.
● Standard type & High sensitivity type available.
● High reliability – twin contact.
● Silver palladium overlaid gold crossbar contact type suitable for lower level
switching application.
● DIL pitch terminal. UL FILE NO: E162117
● High mounting density on P.C. board due to small size and lightweight.
● Nominal power 150mW and 500mW.
● Operating power 100mW~300mW. 941 Referential Data
Timing
15
CONTACT RATINGS
●Contact Arrangement………………. 2 Form C (DPDT)
Time (msec.)
10
●Mechanical Life……………………..2×107 40
1A
● Initial Insulation Resistance 30 0A
● Vibration Resistance
Operation(x104)
100
………Malfunction: 10 to 55Hz at Double Amplitude of 1.5mm 30VDC Resistive
50
………Destructive: 10 to 55Hz at Double Amplitude of 1.5mm
● Shock Resistance 10
………Malfunction: 10G (11ms) / Destructive: 100G (6ms) 5
125VAC Resistive
●Ambient Temperature…………………-30℃~+70℃ 0 0.5 1.0 1.5 2.0
17
ORDERING INFORMATION
941 H- 2C - 12 D
1 2 3 4 5
Coil Type……………….…………….. D: DC
Coil Voltage……………..……………..4.5~48V
Contact Arrangement………………….2C = 2 Form C (DPDT)
Coil Sensitivity…………………….… Nil = Standard Type
………………………….H = High Sensitive Type
Model Number………………………...941
OUTLINE DIMENSIONS