Professional Documents
Culture Documents
Commissioning Fungtion HMC
Commissioning Fungtion HMC
ELECTRICAL SYSTEM
CHECK BATTERY MAIN SWITCH
CHECK TERMINAL SUPER STICTURE ELECTRICS CABINET
CHECK CHANGE OVER SWITCH
3 - PHASE GENERATOR CHECK VISUAL
CLEAN AIR GRILLS
CHECK AUXILIARY POWER SUPPLY
ELECRICAL ROOM VISUAL CHECK AIR CONDITIONER
VISUAL CLEAN AIR CONDITIONER
CLEAN AIR CONDITIONER FILTER
CHECK ALL COMPONENTS FROM FIRM SEATING
HOIST MOTOR VISUAL CHECK
CLEAN FILTER FREECE
SLEWING GEAR MOTOR HOUSING VISUAL CHECK
CLEAN FILTER FREECE
SLACK ROPE SWITCH TEST FUNCTION
BOOM LILIT SWITCH TEST FUNCTION
BOOM CABLE REEL MOUNTING TEST FUNCTION
HEATING AND BRUSHES
BOOM CABLE REEL CHECK GEAR OIL LEVEL
STARWAY LIGHTING TEST FUNCTION
LIGHTING TEST FUNCTION
INTERCOM SYSTEM TEST FUNCTION
EMERGENCY STOP BUTTON TEST FUNCTION
VIDEO CAMERA TEST FUNCTION
HYDRAULIC SYSTEM
DIESEL ENGINE
CHECK OIL LEVEL
CHANGE OIL
CHANGE MAIN FLOW FILTER
CHANGE SECONDARY MAIN FILTER
CLEAN VENT FILTER
CLEAN FUEL PRELIMINARY FILTER
CHANGE WATER FILTER
CHECK COOLANT PRE-HEATER
EMPTY CRANK HAUSE VENT TANK
TEST RUN UNUSUAL NOISE
HEAVY SMOOKE
STABILIZER
VISUAL CHECK
SLEWING GEAR
CHECK OIL LEVEL AND BREATHER FILTER
SLEWING GEAR BRAKES CHECK BRAKE LININGS
ROLLER BEARING SLEW RING CHECK RUNNING NOISE AND BOLTS
HOIST
HOIST REDUCTION GEAR UNIT CHECK OIL LEVEL
CHECK BREATHER VALVE
ROPE DRUM CHECK ROPE CLAMPS FOR FIRM SEATING
CHECK ROPE GROOVES
COUPLING TEST FUNCTION
ROPE EXIT SEALS VISUAL CHECK
HOIST SPEED 1 ST GEAR SPEED WITH 100 T LOAD 0 - 15 M/MIN
1 ST GEAR SPEED WITH 60 T LOAD 0 - 25 M/MIN
1 ST GEAR SPEED WITH 26 T LOAD 0 - 40 M/MIN
TOWER/BOOM SYSTEM
TOWER HEAD ROPE PuLLEYS CHECK ROPE PROTECTION
TOWER BOOM/PIVOT POINT VISUAL CHECK
BOOM HEAD ROPE PULLEYS CHECK ROPE PROTECTION
TOWER/SUPERSTUCTURE MOUNTING POINT CHECK BOLTS
BOOM BOLTED JOINT CHECK FOR FIRM SEATING
CENTRAL LUBRICATION
GREASE PUMP CHECK GREASE SUPPLY + TOP UP
PIPE NETWORKS AND LUBRICATION PONTS VISUAL CHECK
BASIC STRUCTURE
PAINT WORK VISUAL CHECK
STEEL STRUCTURE STRAIGHTEN DEFORMATIONS
CHECK LADDER,STAIRWAY AND PLATFORMS VISUAL CHECK , TOUCH UP DAMAGE
DRIVER CAB
WIPER FUNCTION TEST FUNCTION
TOWER CAB
CONTROL PANELS LIGHTING TEST
WIPER SYSTEM TEST FUNCTION, TOP UP WATER
SEAT TEST FUNCTION
AIR CONDITIONER TEST FUNCTION
WORKING RANGE
HOISTING HEIGHTS
TEST FUNCTION HOISTING HEIGHT ABOVE GROUND AT 11 - 40 METER
RADIUS 34.0 METER
TEST FUNCTION HOISTING HEIGHT ABOVE GROUND AT 40 - 46 METER
RADIUS 33.0 METER
TEST FUNCTION HOISTING HEIGHT ABOVE GROUND 46 - 50 METER
RADIUS 23.O METER
TEST FUNCTION HOISTING HEIGHT BELOW GROUND 15.0 METER
Pekanbaru,……………………………………….