Drawing Radiator

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

App. 4860 App.

2240
4140 2200 Fin
3900 Fin 2087
3728 2070 ±10
Terminal 470 ±10 470 ±10
box
Vent ball 38
valve 1/2" O

339
IN HT

572
OUT HT
IN LT

App. 1910
OUT LT

100 Fin HT
Drain ball

A.D.
100 Fin LT
Drain ball SS name plate

1367 ±10
1267 ±10
valve 1/2"

200 Fin
valve 1/2" inspection cover (both side) 170 ±10 170 ±10

1167 ±10
DIN ISO 2768-2, tolerance class component parts K / assembly L; lenght >3m EN 10162, tolerance straightness and flatness 0,002xl (lenght)

1076,5
DIN ISO 2768-1, tolerance class component parts m / assembly v ; lenght >4m DIN 7168, tolerance class component parts m / assembly sg,

1000
52 ±5 A 3800 ±5 52 ±5 2136 ±5
protection note acc. to DIN ISO 16016

3900 ±10
150
IN LT 52

IN HT
S-GFHV WD 090.2OF/22A-56
Heat pump brine heat exchanger

52
connections in air direction right

150
Accessories :
O - 1 set extended legs 1000 mm
17 - Ball valve 1/2" for ventilation/drain
- Inspection cover

View A - Header cover


- Welding neck flanges DN65 PN16 B1 (DIN EN 1092-1)
- Repair switch (single-speed) wired to front (5209507)
- Terminal box
A P P R O V E D 4 x (5209445) Terminal block for fan TB Fan 3ph 2.5 x1
4 x (5209833) Terminal block for fan 01xTK
OUT HT 1 x (5209345) Terminal box (plastic) 254x180x90mm
Date :
Extra accessories :
- SS name plate
DIN EN ISO 13920, tolerance class D

By :
OUT LT - SS nuts and bolts
Please sign here for approve
- Welding neck flanges DN80 PN16 B1 (DIN EN 1092-1)
header cover / connection roof scale sheet 1/1 size DIN A3
measures without specification of tolerances:

TECHNICAL DATA material


F/4/44/2.40/3900/GCS//1 (HT) Fin material AlMg, 0.18mm
Coil type F/6/44/2.40/4500/ACS/1 weight [kg]
F/4/44/2.40/3900/GCS/1 (LT) Casing material Galv. Steel, RAL 7035
Tubes Copper, Ø12x0.30mm notice
Tube pitch 25x50mm type S-GFHV WD 090.2OF/22A-56
Fin spacing 2.40 mm
name Drycooler
Vol. of Weight Weight
No. of No. of Header inlet (mm) Header outlet (mm) Surface
No. of lines tubes empty operation
general tolerances:
general tolerances:

circuits passes Baan-No.


welding / brazing:

ø ø Tube in Flange ø ø Tube out Flange (liter) (m^2) (kg) (kg)


1N (HT) 88 2 88.9 88.9 DN80PN16 88.9 88.9 DN80PN16 103 696.4 revision date name
1141 1339.5 drawing number 700-0001595590 index
1N (LT) 88 2 76.1 76.1 DN65PN16 76.1 76.1 DN65PN16 95.5 696.4 date name
PT. GÜNTNER INDONESIA
Wonokoyo-Beji,Pasuruan drawn: 25.03.2024 agozali customer Asia Clean Energy
Axial fan data (VT01359U) Telp. +62.343-295 100
-295 200 certified: project/ quantity JGS 320
ø mm Fan type 1/min kW Ampere Volt Phase Hertz Qty Fax. +62.343-295 295
900 FC091-6DI.7Q.V7 LE (154253) 940/820 1.75/2.20 5.9 400 3 50 4 order/ position 10
DN80PN10;DN65PN10;;JB;LT;HT;