SPECIFIC NOTES :

· GRADE OF CONCRETE MIX SHALL BE M20 & REINFORCEMENT SHALL BE


HIGH STRENGTH DEFORMED BARS OF GRADE FE:500 CONFORMING TO
BIS1786:2004
· TOP LEVEL OF ALL BEAMS SHOULD BE AT SAME LEVEL,UNLESS NOTED
OTHERWISE.
· BASEMENT HEIGHT TO BE DISCUSSED WITH ENGINEER DURING SITE
S VISIT SHOULD BE ENSURED.
· ALL COLUMNS TO BE TAKEN ABOVE PLINTH BEAM LEVEL TO ROOF,
UNLESS NOTED OTHERWISE.
· READ THE DRAWING ALONG WITH ELEVATION DETAILS.
· ALL DIMENSIONS ARE IN "FEET & INCHES” UNLESS NOTED OTHERWISE.
GENERAL NOTES :
· ALL LEVELS ARE FROM UNFINISHED FLOOR LEVEL (UFL +0.00LVL)
· CLEAR COVER TO MAIN REINFORCEMENT (USING CEMENT COVER
BLOCKS) SHALL BE AS FOLLOWS.
BEAM-25MM(1”) , SLAB-15MM(%”)
LAPPING
12" 12"
a) IN BEAMS-THE BOTTOM STEEL SHALL BE LAPPED AT SUPPORT & TOP
STEEL SHALL BE LAPPED NEAR MID-SPAN
2 - 16# ST+ 2 - 16# ST b) NO LAPPING SHALL BE ALLOWED IN TOP STEEL OF CANTILEVER BEAM,
3 - 16# CTLD TOP STEEL AT CONTINUOUS SUPPORT, BOTTOM STEEL AT MID SPAN.
c) LAP LENGTH FOR REINFORCEMENT = 50 TIMES BAR DIAMETER.

18"
18"
8# @4" C/C 8# @6" C/C
· ALL THE REINFORCEMENT SHALL BE PLACED AND MAINTAINED IN THE
POSITION SHOWN IN THE FIGURE BY PROVIDING PROPER COVER
2 - 16# ST 2 - 16# ST+
BLOCKS.
3 - 16# CTLD · HOOK BEND FOR STIRRUPS SHOULD BE MIN 75MM(3”).
· FIRST STIRRUP FOR BEAM SHOULD START AT 50 mm (2”) FROM FACE OF
END SPAN MID SPAN COLUMN.
· SPACER BAR TO BE PROVIDED IN BETWEEN TWO LAYERS OF
REINFORCEMENT IN BEAM @ EVERY 1000 C/C, DIA OF SPACER BAR
C1 C1 Beam - RB1 SHOULD BE OF SAME AS DIA OF BEAM MAIN BAR.
· IN REINFORCEMENT DETAILING,
ST. -INDICATES STAIGHT ROD THROUGHOUT
RB1 CKD. -INDICATES ROD CRANKED AT 4TH CLEAR SPAN FROM
SUPPORT.
CTLD.-INDICATES CURTAILED ROD AS PER LONGITUDINAL
9" 9" SECTIONAL DETAIL GIVEN.
Main 10mm
· REMOVAL OF FORMWORK:
Slab 5" tk @ 6" c/c VERTICAL FORMWORK — 24 HOURS
2 - 12# ST+ 2 - 12# ST
2 - 12# CTLD SLABS SPANNING UPTO 4.5m — 7 DAYS
SLABS SPANNING OVER 4.5m — 14 DAYS
RB2 RB2

14"
14"
8# @6" C/C 8# @6" C/C BEAMS SPANNING UPTO 6m — 14 DAYS
BEAMS SPANNING OVER 6m — 21 DAYS
· CHIPPING OF ANY STRCTURAL CONCRETE ELEMENTS SHALL NOT BE
2 - 12# ST 2 - 16# ST+
Distributed DONE IN ANY CIRCUMSTANCES UNLESS WITH SPECIAL PERMISSION OF
2 - 16# CTLD
CONSULTANT.
8mm @ 8" c/c END SPAN MID SPAN · THE CONTRACTOR IS RESPONSIBLE FOR THE DEFECTS & FINANCIAL
DAMAGES DUE TO FAILURE IN CENTERING AND SHUTTERING OF THE
C2 R.C.C WORK
RB1 · FOR DRYING SHRINKAGE CRACK,WHICH IS A NON STRUCTURAL CRACK
Beam - RB2
C1 C1 & COMMON BEHAVIOUR OF CONCRETE,SPECIALLY IN FLEXURAL
MEMBERS DESIGNER IS NOT RESPONSIBLE. TO AVOID DRYING
SHRINKAGE,NECESSARY MEASURES SHALL BE TAKEN BY CLIENT &
Main 10mm CONTRACTOR
9" · “DESIGNER” IS NOT RESPONSIBLE FOR ANY PROGRESSIVE FAILURE
@ 6" c/c AND CONSEQUENT DAMAGE DUE TO BAD WORKMANSHIP, USE OF
FAULTY MATERIAL AND IF INFORMATION IN THE DRAWING IS EXECUTED
RB2 3 - 10# Anchor bar S.No: Column Size THROUGH NON QUALIFIED AND INCOMPETANT PERSONS
5"

Slab 5" tk 8# @6" C/C 1 C1 18" X 12" · ONLY POTABLE (DRINKING) WATER TO BE USED FOR ALL RCC WORKS.
3 - 10# Anchor bar 2 C2 12" X 15" · ALL CONCRETE WORK SHALL BE MACHINE MIXED AND MACHINE
VIBRATED.
· USE SUITABLE WATERPROOFING COMPOUND IN CONCRETE FOR ALL
RB2 WATER RETAINING STRUCTURES.
Beam - RB3 · READ THIS DRAWING ALONG WITH ARCHITECTURAL PLAN, SECTION &
Distributed ELEVATION DRAWINGS. ANY DISCREPANCY IN THE DWG SHALL BE
BROUGHT TO CONSULTANTS NOTICE BEFORE EXECUTION.
8mm @ 8" c/c · DO NOT SCALE THIS DRAWING. FOLLOW THE GIVEN DIMENSIONAL DATA
ONLY.
· KINDLY GIVE US 24 HOURS TIME FOR INSPECTION BEFORE
RB1 CONCRETING (IF REQUIRED) AFTER 100% COMPLETION OF ALL
C1 C1 BARBENDING WORKS. ALSO INFORM THE CONCRETING SCHEDULE 3
DAYS IN ADVANCE FOR US TO BE PREPARED.

RB2 RB3

GROUND FLOOR

Building:
Drawing Title: Roof Drawing
Floor: Ground Floor