TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Manufacturer DEUTZ
Engine Model F3M 2011
Engine Serial Number 12010820
Starter Type ( air/electric) Electric
Radiator type Non-Metallic
Fan blades ( Metallic/Non-Metallic) Yes
Exhaust ( Spark Arrestor installed) Yes
Fuel Pipes ( wire braided) Yes
Fire blanket ( Installed) Yes
Maximum RPM 1800
Compressor model XAS 97 DD
Compressors make ATLAS COPCO
Compressor Sr no. WUX664197
Checks carried out:
Description Remarks
Cooling system Good Condition
Check radiator for any Damage Yes, free from obstructions
Check Radiator clean & clear from obstruction Yes
Check overflow clear and routed to avoid pollution Yes
Check Radiator filled with correct coolant & cap replaced Yes
Check Radiator , engine & pipe work for leaks Yes, no leaks were observed
Check belt for alignment, tension and damage Yes, properly aligned and no worn outs of belt
Check guards in place & secured Yes, Secured with clamps
Fan belt tension Tight enough for good run
Check fan, hub and Cowell for signs of damage/corrosion Found in good condition
All hoses are in good condition Yes
Coolant level Top upped up to marked level
Fuel System
Check all fuel supply and return hoses Ok
Check fuel level & condition Ok
Check isolating valves correctly positioned Ok
Check tanks gauge Ok
Check Fuel hoses, pipe work Ok
Check tank for leaks Ok
Check vent and overflow pipes open Ok
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
General
Secure all gauges from damage Yes
Check guards placed on rotating/ moving parts Yes, properly positioned
Check for transportation lock Yes
Check for any loosen bolts on the base frame Yes, all bolts were tightened
Check Operation manual or CD Yes
Check for maintenance kit Yes
Check tool box, close and locked N/A
Check feed pump condition N/A
Check strainer condition N/A
Check PSV, bursting disc, PRV and it’s set pressure and Yes, have valid calibration certificates
certificates validity
Check Surroundings clean & clear from obstruction Yes
Pipe work and cables are secure with no trip hazards Yes
Overhead obstructions clearly marked and labeled Yes
Check flow meter removed and dummy installed N/A
Check spark arrestor removed No, Installed to unit
Check general condition of lifting slings and certificate Yes, Valid
validity
Remove battery connection and battery Yes
Ensure that all loose items are removed from skid and Yes
fork lift pockets. Ensure drain plugs are fitted. Also
ensure that no objects are protruding out with the frame
area of the skid
Ensure general appearance of unit is in professional Yes
condition
Complete check up washing Yes
Put Green tags “ Ready for use” Yes
Comments:
During function test of Compressor with fleet no. TAPS-COMP-042, observed that the equipment is functioning in a
good condition.
Tested By Accepted By
Name Name
Position Position
Signature Signature
Date Date
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Description Remarks
Cooling system
Check radiator for any Damage Ok, Good condition
Check Radiator clean & clear from obstruction Found ok
Check overflow clear and routed to avoid pollution ok
Check Radiator filled with correct coolant & cap replaced Yes
Check Radiator, engine & pipe work for leaks No leak
Check belt for alignment, tension and damage Ok
Check guards in place & secured Ok
Fan belt tension Ok
Check fan, hub and Cowell for signs of damage/corrosion Good Condition
All hoses are in good condition Good
Coolant level Ok
Fuel System
Check all fuel supply and return hoses ok
Check fuel level & condition ok
Check isolating valves correctly positioned N/A
Check tanks gauge ok
Check Fuel hoses, pipe work ok
Check tank for leaks No Leak
Check vent and overflow pipes open ok
Check fuel storage facility secure ok
Fuel level/ drain of water ok
Ensure fuel tank side glass is clean N/A
Check fuel tank cap seal ok
Engine oil level & condition Good
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Comments: During function test of Filling Pump with fleet no. TAPS-FP- 030, observed that the equipment is
functioning in a good condition.
Tested By Accepted By
Name Name
Position Position
Signature Signature
Date Date
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Manufacturer CUMMINS
Engine Model NTA 855 C
Engine Serial Number 25325221
Starter Type ( air/electric) Electric
Radiator type Non-Metallic
Fan blades ( Metallic/Non-Metallic) Yes
Exhaust ( Spark Arrestor installed) Yes
Fuel Pipes ( wire braided) Yes
Fire blanket ( Installed) Yes
Maximum RPM 1800
Compressor model XRH 1100
Compressors make ATLAS COPCO
Compressor Sr no. PNA 713111
Checks carried out:
Description Remarks
Cooling system Good Condition
Check radiator for any Damage Yes, free from obstructions
Check Radiator clean & clear from obstruction Yes
Check overflow clear and routed to avoid pollution Yes
Check Radiator filled with correct coolant & cap replaced Yes
Check Radiator , engine & pipe work for leaks Yes, no leaks were observed
Check belt for alignment, tension and damage Yes, properly aligned and no worn outs of belt
Check guards in place & secured Yes, Secured with clamps
Fan belt tension Tight enough for good run
Check fan, hub and Cowell for signs of damage/corrosion Found in good condition
All hoses are in good condition Yes
Coolant level Top upped up to marked level
Fuel System
Check all fuel supply and return hoses Ok
Check fuel level & condition Ok
Check isolating valves correctly positioned Ok
Check tanks gauge Ok
Check Fuel hoses, pipe work Ok
Check tank for leaks Ok
Check vent and overflow pipes open Ok
Check fuel storage facility secure Ok
Fuel level/ drain of water Yes, Facility provided.
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Comments:
During function test of Compressor with fleet no. TAPS-COMP-016, observed that the equipment is functioning in a
good condition.
Tested By Accepted By
Name Name
Position Position
Signature Signature
Date Date
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Manufacturer DEUTZ
Engine Model F3M2011
Engine Serial Number 11993478
Starter Type ( air/electric) Electric
Radiator type Non-Metallic
Fan blades ( Metallic/Non-Metallic) Yes
Exhaust ( Spark Arrestor installed) Yes
Fuel Pipes ( wire braided) Yes
Fire blanket ( Installed) Yes
Maximum RPM 1800
Compressor model XAS 97 DD
Compressors make ATLAS COPCO
Compressor Sr no. WUX664195
Checks carried out:
Description Remarks
Cooling system Good Condition
Check radiator for any Damage Yes, free from obstructions
Check Radiator clean & clear from obstruction Yes
Check overflow clear and routed to avoid pollution Yes
Check Radiator filled with correct coolant & cap replaced Yes
Check Radiator , engine & pipe work for leaks Yes, no leaks were observed
Check belt for alignment, tension and damage Yes, properly aligned and no worn outs of belt
Check guards in place & secured Yes, Secured with clamps
Fan belt tension Tight enough for good run
Check fan, hub and Cowell for signs of damage/corrosion Found in good condition
All hoses are in good condition Yes
Coolant level Top upped up to marked level
Fuel System
Check all fuel supply and return hoses Ok
Check fuel level & condition Ok
Check isolating valves correctly positioned Ok
Check tanks gauge Ok
Check Fuel hoses, pipe work Ok
Check tank for leaks Ok
Check vent and overflow pipes open Ok
Check fuel storage facility secure Ok
Fuel level/ drain of water Yes, Facility provided.
Ensure fuel tank side glass is clean Ok
Check fuel tank cap seal Ok
Engine oil level & condition Top upped up to marked levels
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Comments:
During function test of Compressor with fleet no. TAPS-COMP-044, observed that the equipment is functioning in a
good condition.
Tested By Accepted By
Name Name
Position Position
Signature Signature
Date Date
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
General Data:
Description Remarks
Cooling system Good Condition
Check radiator for any Damage Yes, free from obstructions
Check Radiator clean & clear from obstruction yes
Check overflow clear and routed to avoid pollution yes
Check Radiator filled with correct coolant & cap replaced yes
Check Radiator , engine & pipe work for leaks Yes, no leaks were observed
Check belt for alignment, tension and damage Yes, properly aligned and no worn outs of belt
Check guards in place & secured Yes, Secured with clamps
Fan belt tension Tight enough for good run
Check fan, hub and Cowell for signs of damage/corrosion Found in good condition
All hoses are in good condition Yes
Coolant level Top upped up to marked level
Fuel System
Check all fuel supply and return hoses Ok
Check fuel level & condition Ok
Check isolating valves correctly positioned Ok
Check tanks gauge Ok
Check Fuel hoses, pipe work Ok
Check tank for leaks Ok
Check vent and overflow pipes open Ok
Check fuel storage facility secure Ok
Fuel level/ drain of water Yes, Facility provided.
Ensure fuel tank side glass is clean Ok
DOC. REF. NO. FR-OP-04
TRANS ASIA PIPELINES SERVICES
REV / ISS .NO. 02/03
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
21.12.2020
PRE-MOB & FUNCTION TEST CERTIFICATE DATE
Comments:
During function test of Pressure Pump with fleet no. TAPS-PP-017, observed that the equipment is functioning in a
good condition.