The humidifier used in Huawei's row-level precision air condi oner is an infrared humidifier.
ANSWER: B. False
QUESTION NO: 2
There are generally two types of variable air volume ven lated floors, one is through an adjustable air valve, and the other
is a dedicated ven lated floor plus adjustable fans.
ANSWER: A. True
In the dynamic ring monitoring system, it can be used to store high-defini on images and provide large-scale storage
media. The equipment used for long-term storage of video recording is ____________ .
QUESTION NO: 4
At present, storage ba eries are mainly installed in racks and cabinets in data centers.
ANSWER: A. True
QUESTION NO: 5
The func on of the fire-figh ng system is to automa cally capture the smoke or heat in the fire detec on area when a fire
occurs, so as to issue an audible and visual alarm and automa cally ex nguish the fire.
ANSWER: A. True
QUESTION NO: 6
MCB The main func ons of the circuit breaker include circuit breaker protec on and overload protec on.
ANSWER: A. True
ANSWER: low hardware configura on cost, ups Working under the design, high load condi on the efficiency is the highest
and there liability is higher than that of the mains
QUESTION NO: 8
The compressor is the core of the refrigera on cycle. It is the power device for the refrigerant to circulate in the system. It
reduces the low temperature from the evaporator. The compressed steam is compressed into high temperature and high
pressure steam.
ANSWER: A. True
QUESTION NO: 9
The increase of cabinet power density will lead to the emergence of local hot spots in the computer room, and row-level
air condi oners can solve local problems. The hot spot is too high.
ANSWER: A. True
QUESTION NO: 10 - (FILL BLANK)
CORRECT TEXT
QUESTION NO: 11
Huawei Monitoring System Neteco Can only access support SNMP Protocol equipment.
ANSWER: B. False
The thro ling devices used by Huawei's air-cooled precision air condi oners are
The computer room air condi oner is suitable for scenarios ____________ .
ANSWER: modular data centers, container data centers medium and large data centers
QUESTION NO: 14
STS The sta c transfer switch can switch between different input power sources and provide dual power supply for single
power loads.
ANSWER: A. True
For valve-regulated lead-acid ba eries, the func on of the safety valve is ____________ .
____________ A er star ng, the alarm will send out a strong sound and light alarm signal, which has reached the
purpose of reminding the on-site personnel to pay a en on.
QUESTION NO: 17
The principle of the evaporator is to convert the refrigerant from liquid to gas, take away the heat of the refrigerated
object, and realize refrigera on.
ANSWER: A. True
QUESTION NO: 18
The dynamic environment monitoring system can be deployed in medium and large modular data centers, small modular
data centers, container data centers, etc.
ANSWER: A. True
QUESTION NO: 19 - (FILL BLANK)
CORRECT TEXT
The following are indirect contact heat and moisture treatment equipment ____________ .
QUESTION NO: 20
In the main road mode, when ups The front-end voltage is at 220V±10%When fluctua ng,ups The output voltage will also
have Larger fluctua ons.
ANSWER: B. False
QUESTION NO: 21
ANSWER: A. True
QUESTION NO: 22
ANSWER: data center, computer room, una ended substa on, wireless base sta on, transmission node, computer room
QUESTION NO: 24
UPS systema c N+X System ra o 2N The power supply guarantee level of the system is higher.
ANSWER: B. False
The following ____________ are used in Huawei's row-level precision air condi oners.
QUESTION NO: 26
R410A The moment the refrigerant is sprayed to the outside, it can freeze human skin and deep muscles in a very short
ANSWER: A. True
Dual power switch ATS According to different switch types, it can be divided into____________ .
QUESTION NO: 28
In the air condi oning system, the func on of the oil and gas separator is to separate the lubrica ng oil from the
compressor exhaust and return the separated lubrica ng oil to the compressor.
ANSWER: A. True
The following ____________ is correct 1A fixed valve-regulated sealed lead-acid ba ery 2V Monomer, the rated capacity
is 800Ah.
ANSWER: GFM-800
QUESTION NO: 31
During the ba ery installa on process, the maintenance channel of the high-voltage ba ery pack used should be
insulated.
ANSWER: A. True
QUESTION NO: 32
The dynamic environment monitoring system supports the alarm management func on.
ANSWER: A. True
The type of compressor used by Huawei's air-cooled precision air condi oner is____________ .
In the dynamic environment monitoring system, ____________ is used to indicate the severity of the corresponding fault.
QUESTION NO: 35
In the data center power supply and distribu on system, if a power outage occurs, it is generally caused by Complete the
standby switch between mains and mains or mains and diesel generators.
The following air condi oners are comfortable air condi oners ____________ .
QUESTION NO: 37
The following Does the model of air condi oner have an oil separator?
ANSWER: A B
A. NetCol5000-A25kW
B. NetCol5000-A35kW
QUESTION NO: 38
Huawei Monitoring System NetEco Only the infrastructure of a single data center can be managed, and the centralized
and unified management of mul ple geographically divided data center infrastructures is not possible.
ANSWER: B. False
During the construc on process, carry out low-voltage live work ____________, should be used ____________ .
ANSWER: 1KV , the following: insula ng shoes, insula ng gloves, insula ng clothing
QUESTION NO: 40
The humidifier used in Huawei's row-level precision air condi oner is an infrared humidifier.
ANSWER: B. False
QUESTION NO: 41
ANSWER: A B
A. DB25
B. RJ12
QUESTION NO: 42
RER It is used to measure the use of renewable energy in the data center to promote the regenera on of solar, wind, and
water energy, and the use of energy with no carbon emissions or very li le carbon emissions.
ANSWER: A
A. True
MCB Circuit breakers can be divided into ____________ and (magne c trip) according to the principle of tripping.
For unsaturated air, dry bulb temperature, wet bulb temperature, A The rela onship between point temperature is ____ .
ANSWER: dry bulb temperature > wet bulb temperature > dew point temperature
The thro ling devices used by Huawei's air-cooled precision air condi oners are____________ .
Gas fire-figh ng system refers to a fire-ex nguishing system that uses gas ____________ as the fire ex nguishing medium.
In the dynamic environment monitoring system, viewing the detailed alarm informa on can help locate the source of the
alarm.
ANSWER: A. True
QUESTION NO: 48
Use POE At the interface, it has two func ons: pass and power supply.
ANSWER: A. True
The following ____________ belong to the characteris cs of water-cooled chilled water air condi oners.
ANSWER: need to install a cooling tower suitable for large and medium-sized data centers
ANSWER: a set NetEco The network management system can monitor and manage mul ple micro modules one set
NetEco. The monitoring system can correspond to mul ple ECC800
CORRECT TEXT
ANSWER: ex nguishing agent, storage bo le group, star ng device, firefigh ng pipe network, sprinklers
The following parts can check whether the refrigerant contains moisture ____________ .
QUESTION NO: 53
Leakage current protector is based on the current exceeds the specified value for a period of me, the melt is melted by
its own heat, thereby breaking the circuit.
ANSWER: B. False
QUESTION NO: 54
In the main inverter mode, when the mains input voltage and frequency exceed ups When the allowable range is ups Will
be inverted from the main circuit. The mode shi s to sta c bypass mode.
ANSWER: B. False
QUESTION NO: 55
The surface cooler controls the indoor temperature and humidity through the heat exchange between the refrigerant and
the indoor air.
ANSWER: B. False
QUESTION NO: 56
The fuse can protect personal safety when the equipment leaks.
ANSWER: B. False
QUESTION NO: 57
The dynamic environment monitoring system focuses on data center infrastructure management, and supports the
monitoring of power supply equipment, cooling equipment, environmental equipment and security equipment in the data
center.
ANSWER: A. True
QUESTION NO: 58
In the main inverter mode,ups When overloaded, it will switch from the main circuit inverter to the ba ery inverter mode.
ANSWER: B. False
The user can upgrade the device version in the ____________ interface.
When the load is 60KW, Each ups The capacity is 100KVA, Power Factor 0.95, Then when the system must be redundantly
ANSWER: 2
According to different classifica ons of electrolytes, ba eries can be divided into____________ and ____________ .
QUESTION NO: 62
Huawei Monitoring System NetEco Cannot provide to third-party network management system SNMP Formal interface.
ANSWER: B. False
QUESTION NO: 63
Use POE When interface, it has two func ons of communica on and power supply.
ANSWER: A. True
ANSWER: main circuit inverter mode, sta c bypass mode, ba ery mode
QUESTION NO: 65
Protec ve grounding: Grounding refers to the direct connec on with the earth, and a certain point of the live part of an
electrical device or electrical circuit is connected to a large point. When the electrical device or other device is normal, a
ANSWER: A. True
The role of the safety valve in the ba ery structure prevents excessive internal pressure from being excessive
____________ exclude.
ANSWER: hydrogen H2
QUESTION NO: 67
RS485 The interface only supports two-wire system, not four-wire system.
ANSWER: B. False
In Huawei's dynamic environment monitoring system, it is at the data collec on layer and can integrate the underlying
components ____ . The equipment through which informa on is transmi ed to the monitoring so ware is____.
QUESTION NO: 69
Water cooling/The refrigerant of ethylene glycol air condi oner has been flushed before leaving the factory, so it is
ANSWER: A. True
QUESTION NO: 70
ANSWER: A. True
____________ The main func on is electric energy distribu on, which distributes the frontend electric energy to various
specifica ons, such as ups, Air condi oning, ligh ng system, etc.
During the construc on process, the opera on with debris splashing should be used____________ .
ANSWER: A. True
PUE The closer the value ____________, indica ng that the energy efficiency status of the data center is good.
ANSWER: 1
QUESTION NO: 75
In the low-voltage power distribu on system, N The role of the wire is to return the AC opera ng current.
ANSWER: A. True
Which of the following descrip ons about the air supply method from top to bo om is correct ____________ .
ANSWER: the air supply outlet is located in the upper part of the air-Condi oned room and the return air outlet is located
in the lower part of the air-condi oned room
ANSWER: NETECO server, ECC800 intelligent ETH Socket, skylight execu on Device
QUESTION NO: 78
The role of the lead-acid ba ery ba ery is to contain electrolyte, plates, separators, etc.
ANSWER: A. True
The following ____________ are not part of the chilled water air condi oner.
ANSWER: condensants
Huawei chilled water air condi oners rely on ____________ to adjust the water flow.
During the construc on process, if there is an object falling or hi ng, it should be used____________ .
Huawei Monitoring System NetEco Support through ____________, send alarm informa on to customers.
According to the degree of equipment concentra on, the air condi oning system can be divided into ____________ .
QUESTION NO: 84
The following air condi oners do not need to install cooling towers.
ANSWER: A C
QUESTION NO: 85
The func on of Huawei's chilled water air condi oner plug-in frame power supply is to provide a stable power supply for
the fans.
ANSWER: A. True
During the construc on process, the nitrogen bo le opera on must be equipped with special ____________ .
QUESTION NO: 87
The leakage protector is mainly divided into electronic type and electromagne c type according to the ac on mode.
ANSWER: A. True
The following ____________ air supply methods mainly use process air condi oners that have a large amount of waste
heat to be taken away from the lower working area.
QUESTION NO: 89
TN-S The three-phase unbalanced current in the low-voltage power distribu on system makes the protec on line PS
ANSWER: B. False
QUESTION NO: 90
The alarms of the dynamic environment monitoring system usually have different levels.
ANSWER: A. True
QUESTION NO: 91
ANSWER: B. False
QUESTION NO: 92 - (FILL BLANK)
At a certain atmospheric pressure and water vapor content, the air is cooled down. When the air reaches satura on, it will
Through the query ____________, the user can understand the opera on of the device.
According to the storage methods of different electrolytes in ba eries, it can be divided into____ with _____ .
QUESTION NO: 95
The following () op ons belong to water-cooled chilled water air condi oners. (Mul ple choice)
ANSWER: C D
The following ____________ are not harmful effects of electric current on the human body.
ANSWER: spli ng
QUESTION NO: 97
The administrator cannot segment the login me and login of other users through the
ANSWER: B. False
Regarding the descrip on of the data center cooling system, the following ____________ is wrong.
ANSWER: in the cabinet-level row-level and room-Level cooling, the airflow path of the rowlevel cooling method is the
shortest
Lay an -sta c floor, wear an -sta c shoes and socks to prevent it from forming ____________ .
The main fire ex nguishing agent used in the data center fire protec on system is ____________ .
ANSWER: heptafluoropropane
QUESTION NO: 101 - (FILL BLANK)
Reflects the dryness of the air, the smaller the value, the drier the air.
In the access control system interface, the func ons that can be realized are____________ .
ANSWER: A B C D
The user can use the ____________ func on to assign personnel to handle the fault.
Use RS485 Communica on method, the maximum communica on distance is____________ Meter.
ANSWER: 1200
Low-temperature components can improve the con nuous low pressure caused by low temperature start, so that the air
ANSWER: A. True
ANSWER: RJ45
Level, for IT For load, you should use ____________ class Tripping characteris cs.
ANSWER: C
Huawei monitoring system ECC800 The collector can be inserted at most ____________ A power supply module.
ANSWER: 2
UPS The front-end input can be two mains, one main and one standby, or one mains and one diesel engine input.
ANSWER: A. True
QUESTION NO: 111 - (FILL BLANK)
The following ____________ Circuit breakers are usually used IT Low-voltage circuit breaker for the load.
ANSWER: MCB
In the dynamic environment monitoring system, the user queries the alarm informa on of the refrigera on equipment
through the ____________ func on.
ANSWER: KVA
During the implementa on process, corrosive opera ons should be used ____________ .
ANSWER: an -Corrosion liquid goggles, acid and alkali resistant gloves, acid and alkali resistant clothing, chemical resistant
shoes
The basic principle of the rotary dehumidifier is that the water vapor encounters the condensa on water droplets of the
ANSWER: B. False
The parameters that can reflect the energy efficiency and energy use efficiency of the data center are ____________ .
ANSWER: PUE
The condensate of the air condi oner is formed by condensa on a er the air warning surface cooler cools down.
ANSWER: A. True
pPUE is a data center PUE An extension of the concept, used to evaluate the energy efficiency of a local area of a data
ANSWER: A
A. True
ACB The actual work of the circuit breaker can reach several thousand amperes, and at the same me, it requires high
The air-condi oning energy efficiency ra o is the ra o of the effec ve input power to the cooling capacity, and its value is
W/W Express.
ANSWER: B. False
ANSWER: configura on management, alarm management, access control management, ba ery monitoring
When the AC power equipment is introduced in the three-phase four-wire system, in addi on to the grounding of the
near end of the power transformer, the near end of the electrical equipment and the equipment room should be
grounded repeatedly on the neutral line.
ANSWER: A. True
The data center computer room monitoring system mainly monitors power systems, environmental systems, and fire
figh ng systems.
ANSWER: A. True
UPS The inverter component can realize the conversion from AC to DC.
ANSWER: B. False
CLF Defined as the power consump on of data center cooling equipment and IT The ra o of the power consump on of
the device.
ANSWER: A. True
During the construc on process, work in contact with sharp instruments and use____________ .
The following components that can improve the heat exchange capacity of the heat exchanger are ____________ .
ANSWER: fan
QUESTION NO: 129
Data center room PUE The smaller the value, the greater the power consumed by the suppor ng infrastructure of the
datacenter such as cooling and power supply.
ANSWER: B. False
Climbing personnel must be equipped with necessary safety belts that meet the safety requirements, and use them
correctly and reasonably according to the use regula ons, while being supervised.
ANSWER: A. True
Huawei Monitoring System NETECO Support hierarchical network management func on.
ANSWER: A. True
Huawei Monitoring System NETECO The system does not support remote door opening.
ANSWER: B. False
If ups The capacity is 20KVA, Then in normal work,ups The front-end input capacity may be ____________ .
ANSWER: 25KVA
CORRECT TEXT
The func on of the air system is to ra onally organize the flow of indoor air, so that the temperature, humidity and
cleanliness of the air in the indoor working area can be er meet the process requirements and the comfort requirements
of the human body.
ANSWER: A. True
The following air condi oning, which is comfort air condi oning?
When the mains input range is voltage:150-260V AC, frequency:45-60Hz, the following ups
Working range ____________ It can work normally in the inverter state of the main circuit.
ANSWER: A. True
ANSWER: C
C. When the ba ery reaches the end of its service life, it does not require special treatment and can be sold directly to
scrap for recycling.
Exist UPS in the system, the most comprehensive descrip on of the role of the inverter circuit is ____________ .
ANSWER: conver ng the rec fied DC voltage of the main, sor the ba ery volt agein to AC voltage
The following outdoor unit models belong to dual fans are ____________ .
ANSWER: Netcol500-A072
In the low-voltage power distribu on system, PE The func on of the line is to provide a path for the fault current when
the power supply system fails.
ANSWER: A. True
ANSWER: A. True
The following ____________ Is the correct statement 6 Two fixed valve-regulated sealed lead-acid ba ery cells are
ANSWER: 6-GFM-150
The valve-controlled sealed lead-acid ba ery safety valve has ____________ Func on.
ANSWER:
Regulate the internal and external pressure of the ba ery filter, the acid mist and prevent the internal pollu on of the
ba ery
When the sunroof actuator senses a smoke alarm, it cannot control the turning sunroof to open automa cally.
ANSWER: B. False
QUESTION NO: 147 - (FILL BLANK)
In the ba ery structure, the ____________ component func ons to remove excess gas.
Huawei Monitoring System NetEco Supports the concept of user groups, and implements role-based user group
management. A user group is a group of user-level collec ons with the same opera on permissions, and different user
ANSWER: A. True
PLE Defined as the power consump on of the data center power supply and distribu on system and IT The ra o of the
ANSWER: A. True
ANSWER: Netcol5000-A
ANSWER: wipe it clean with a rag, with gloves on and check if it needs to be replaced
ABC Circuit breakers are mainly used IT Load front end, such as ups Inside the output cabinet.
ANSWER: B. False
QUESTION NO: 156
The use of water fire and foam fire ex nguishing systems in the data center will not cause damage to communica on
equipment.
ANSWER: B. False
High sensible heat ra o is the only difference between precision air condi oners and civil air condi oners.
ANSWER: B. False
R410a Refrigerants can produce the greenhouse effect and destroy the ozone layer.
ANSWER: B. False
The possible func ons of the dynamic loop monitoring system include ____________ .
ANSWER:
Opera on status monitoring, opera ng parameter, display alarm informa on, display remote Process management
The general method of connec ng lead-acid ba eries is to string first and then parallel.
ANSWER: A. True
CORRECT TEXT
ANSWER: FE
At the end of the discharge of lead-acid ba eries, the voltage drops, and the posi ve and nega ve ac ve materials are
ANSWER: PbSO4
When the ba ery is in use, sunlight can directly shine on the ba ery.
ANSWER: B. False
One ups The capacity is 200KVA, Its output power factor is 0.9, Then it can drive at most____________ load.
ANSWER: 180KW
QUESTION NO: 165
The basic principle of infrared heaters is that infrared rays heat water to boiling, thereby genera ng steam.
ANSWER: B. False
There are three different classifica ons of grounding forms in low-voltage power distribu on systems, ____________ . The
ANSWER:TN, TT, IT
Represen ng the rela onship between the exposed conduc ve part of the power receiving system and the ground
The ____________ func on of the dynamic loop monitoring system can display the real me status of the equipment.
In the data center power supply and distribu on system, the low-voltage circuit breaker with three-stage protec on
feature is used for.
ANSWER: B D
B. Prevent the main circuit from being overloaded due to the short circuit of the branch circuit
D. Prevent the main circuit from breaking due to a short circuit in the branch circuit
The following ____________ Yes UPS 2N. The advantages of the system.
ANSWER: Power supply redundancy, no need to switch the load to maintenance bypass mode, you can ups System
maintenance no single path failure point
The access control system can only set the user to open the door, and cannot set when to open the door.
ANSWER: B. False
Compared with comfort air condi oners, special air condi oners for computer rooms have the following advantages
____________ .
ANSWER: Large air volume, small enthalpy difference. High sensible heat ra o, more accurate temperature and humidity
control. Year-round cooling
UPS It can purify the mains input, output stable AC, and protect the load.
ANSWER: A. True
QUESTION NO: 173
The following is for high frequency ups The correct descrip on of the rec fier components is.
ANSWER: A D
A. Complete AC to DC conversion
ANSWER: B
Interna onal Electrotechnical Commission ____________. The specified contact voltage limit is ____________V, And
s pulate 25V. The following does not need to consider the preven on Safety measures to prevent electric shock.
ANSWER: IEC, 50
For only having Modbus The power supply and distribu on equipment of the agreement can be passed ____________
ANSWER: RS485
There are three different classifica ons of grounding forms in low-voltage power distribu on systems ____________,
where the first capital le er represents ____________ .
The rela onship between the power system and the ground
ANSWER: A. True
The following ____________ op ons do not belong to the characteris cs of direct aircooled air-condi oning.
The device cannot be connected to the southbound interface of the dynamic environment monitoring system.
ANSWER: R410A
____________ Not part of Huawei's monitoring system NETECO Provide monitoring func ons.
ATS The dual power supply automa c switch can realize the fast mechanical switching of the two power supplies.
ANSWER: A. True
The principle of the condenser is to cool the high-pressure gaseous refrigerant to release heat into a liquid state to realize
ANSWER: A. True
The fire figh ng system of the computer room is mainly composed of ____________ system.
ANSWER: automa c fire alarm, gas fire ex nguishing, smoke preven on and safe evacua on
DB9 It is an agreement.
ANSWER: B. False
In the air-condi oning system, the func on of the ____________ is to use water cooling or air cooling to cool the high-
temperature and high-pressure gas discharged from the compressor and release heat to the outside world.
ANSWER: condenser
MCB Circuit breaker C. The se ng value of level tripping is in ____________, used in IT Load occasions.
ANSWER: 5-10ln
Under the same load condi ons, ups The backup me is mainly determined by the ba ery capacity and the number of
ba ery cells. The larger the ba ery capacity, the longer the backup me.
ANSWER: A. True
Huawei Monitoring System NetEco Must not support monitoring of third-party devices.
ANSWER: B. False
QUESTION NO: 191
ANSWER: A. True
Data center energy consump on mainly comes from environmental equipment, ligh ng systems, refrigera on systems,
power distribu on systems, etc. How to reduce the energy consumed by ____________ is the key to solving data center
It can be implemented in the alarm management func on of the dynamic environment monitoring system ____________
ANSWER: loca ng alarms, querying alarms
____________ is used to ensure that the fire ex nguishing agent has been sprayed out in a specific jet form to promote
the rapid gasifica on of the fire ex nguishing agent and reach the fire ex nguishing concentra on in the protected space.
ANSWER: Nozzle
ANSWER: voltage stabiliza on, frequency stabiliza on, an -voltage surge, con nuous power supply to the load when
there is no mains
CLF Defined as the power consump on of data center cooling equipment and IT The ra o of equipment power
consump on.
ANSWER: A. True
UPS Also known as AC uninterrupted power supply system, for online ups. When the AC input is normal, the
____________will supply power to the system.
ANSWER: inverter
same MCB Rated ul mate short-circuit breaking capacity of circuit breaker LCU Generally less than the rated opera ng
ANSWER: B. False
QUESTION NO: 200 - (FILL BLANK)
CORRECT TEXT
The following four major components that are not air condi oners are ____________ .
ANSWER: fans
The following ____________ is not the basic func on of low-voltage circuit breakers.
Environmentally friendly refrigerant R410A Refrigera on performance is be er than non-refrigerant R22 be er.
ANSWER: B. False
At present, the communica on methods used by the dynamic environment monitoring system are ____________ .