Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

mA-2000 Clamp On Non-Contact Milliammeter

ClampOn Milliammeter
Measuring Current
Range
Low ................................................................................................ 0-200 mA dc or RMS ac
High .............................................................................................. 0-2000 mA dc or ac peak
Resolution
Low Range ............................................................................................................... 0.1 mA
High Range ................................................................................................................ 1 mA
Frequency Range ................................................................................................ dc to 100 kHz
ac Low ............................................................................................................ dc to 200 Hz
ac High .................................................................................................. 200 Hz to 100 kHz
-3 dB .................................................................................................................... 200 kHz
Accuracy (+3 counts)
dc: ................................................................................................................. 1% of reading
ac: up to 200 Hz ..................................................................................... 2% of reading
200 Hz to 400 Hz .............................................................................. 4% of reading
400 Hz to 40 kHz .............................................................................. 2% of reading
up to 200 Hz ..................................................................................... 3% of reading
Repeatability (+3 counts) ................................................................................... 0.5% of reading
Readout ........................................................................................................... 3 1/2 digit LCD

Output
Analog ....................................................................................................................... 1mV/mA
Connector ....................................................................................................................... BNC
Noise ................................................................................................................ <100uV RMS

Influences on Accuracy
Temparature Coefficient ......................................................................................... .01%/oC Max.
Adjacent Conductor .................................................................................................. <100uA/A

General Information
Operating Temparature ........................................................................................ 0o C to 50o C
Storage Temperature Range ........................................................................... -25o C to +70o C
Battery ................................................................................ Two 9 V Alkaline (NEDA 1640 A)
Battery Life (typical) ............................................................................................... 15 Hours
Safety ................................................................. IEC 1010 Cat 2 300 V, pollution degree 2 (*)
Aperature Opening ................................................................................ 0.21 inches (5.3 mm)
Size: Probe ........................................................................................................... Meter
6.25 inches (15.9 cm) length .......................................... 5.2 inches (13.2 cm) length
1.2 inches (3.0 cm) diameter ............................................ 5.3 inches (13.5 cm) width
...................................................................................... 1.5 inches (3.8 cm) height

Patent pending
(*) Approval pending
mA-2000 Clamp On Non-Contact Milliammeter

ClampOn Milliammeter
Description
The model mA-2000 provides non-contact measurement of very low dc and ac currents. It features an
easy-to-read 3 1/2 digit display and analog ouput for connection to an oscilloscope or recorder

Features
• True RMS measurement
• Built in 3 1/2 digit display
• Simple clamp-on operation
• Frequency range DC to 100kHz
• Supplied with hard carrying case
• Basic DC accuracy of 1% of reading
• Built to IEC 1010 safety standards/Approval Pending
• BNC analog output for connection to oscilloscope or recorder
• Measures low level DC & AC currents from 0 to 2000 mA with resolution as low as 0.1 mA.

Typical Applications
• Data Stream verification
• Measuring ground currents
• Isolating faults on electronic circuits
• Verification of power supply currents
• Troubleshooting 4-20 mA control loops
• Automotive computer control diagnostics
• Low current measurements in R&D Laboratories

You might also like