Overview

● Measure molten steel temperature

Feature
● In the field, safety and reliability has been verified by cast iron
factories for a long period of time.

● Motion sensor used to extend the period of battery life by


automatic ON/OFF

● Li-ion battery of high stability


Specifications

Item Feature Remark

Type R / S (500 ~ 1750℃)


Default R Type
Input T/C
(Factory Setting)
Type B (500 ~ 1800℃)

Display LED 4 Digit Height 14.2mm

Green Ready

Yellow Run
Signal Lamp
Red, Buzzer End

Blue Battery alarm

Accuracy ±2.0℃ Full Scale

Resolution 1℃ Stored Data 0.1℃

Data Sampling rate 100ms

Power DC 5V (4500mAh) Rechargeable Li-ion

Power Consumption 0.9W

Operation Environment 0 ~ 55℃, ~ 90% RH

Dimension / Weight 150 X 90 X 65 mm / 1.0Kg Without handle

※Specifications are subject to change without notice.