CE-radio Catalog

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Overview

● Measure solidification temperature of molten metal to calculate a carbon


equivalent, silicon, and phosphorus.

Feature
● Compensating cables are not required because of wireless communication
between the CE-radio and the CE-tracer, and it is easy to use them
● Wireless CE-tracer can be connected up to three CE-radio.
● The external AC power is connected to CE-radio, and Users don’t need to
consider about battery charging.
● Users can use existing CD-CUP holder with new wireless CE-tracer.

A Furnace

B Furnace

C Furnace
Specifications
Classification Feature Valuable data /Remark
Analysis program for Grey
Determination of C%, CEL/Sc, Si%,
and white solidification of
undercooling △T, △TM
Cast iron melts
Calculation by tensile strength (Rm), graphite factor
Additional program for (K)
unalloyed grey cast iron Brinell-hardness (HB), quantity of the eutectic
melts graphite(MEG)
Tensile strength hardness factor (Z/H)
Arithmetically linearized
Temperature measuring
Type K (400 ~ 1370℃) According to ITS90
range
Resolution 0.1℃
Accuracy ±1.5℃ Full Scale
Display 15’ TFT Color Screen
Key in Keyboard, Mouse
Operating system MS Windows 7
CPU Intel Atom N2600 (1.6Ghz)
Computer
SSD 120Gbyte
RAM 2Gbyte
Measurement Result storage Over 3,000 Measurements
Data transmission CE-radio ⇔ CE-tracer IEEE 802. 15. 4 (Zigbee) Max.100ms(if no barrier)

VGA 1 Port
Data interfaces
Serial RS-232
CE-radio 160(W) x 260(H) x 90(D)
Dimensions of Housing
CE-tracer 400(W) x 380(H) x 310(D)
CE-radio Approximately 2.8kg
Weight
CE-tracer Approximately 15kg
Power supply CE-radio, CE-tracer 100~240 VAC
Power CE-radio 0.9W
Operation
consumption CE-tracer 160W
Data
Ambient
0℃ up to 50℃
temperature

※Specifications are subject to change without notice.