ROOF PLAN GENERAL NOTES

1 1. SEE ROOF PLANS FOR ROOF SLOPES


______________________

A3.20 2. PROVIDE ICE AND WATER SHEILD FLASHING WHERE ROOF PITCH CHANGES, WHERE
ROOF INTERSECTS VERTICAL SURFACES, AT ALL ROOF EAVES, AND PER ROOFING
MANUFACTURER'S WRITTEN INSTRUCTIONS.
145'-0" 3. PROVIDE HIGH-TEMPERATURE UNDERLAYMENT FOR ENTIRETY OF ALL METAL
ROOF AREAS.
2'-0" O.H. 141'-0" 2'-0" O.H.
4. PROVIDED GABLE END TRUSSES AT ALL GABLE END CONDITIONS AND AT ALL
4" 4" VERTICAL DRAFTSTOP LOCATIONS ABOVE AND IN LINE WITH DEMISING WALLS.
5. ROOF SHINGLES TO BE MINIMUM CLASS B. VERIFY SHINGLE INSTALLATION
D.S. 12'-1 1/4" 11'-10 3/4" 11'-10 3/4" 12'-1 1/4" D.S. REQUIREMENTS WITH CHINGLE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR
PRODUCT TYPE AND APPLICATIONS.
6. ALL ROOF SHINGLES ARE TO OVERHANG DROP EDGES AT EAVES AND RAKES A PROJECT # : 122154
15'-0" SOFFIT VENT D.S. D.S. E23 D.S. 15'-0" SOFFIT VENT MINIMUM OF 1/2".

3'-0" O.H.
7. PROVIDED 22"x30" RATED ATTIC ACCESS HATCH, 1-HOUR, WITH LOCK. FIELD DRAWN BY: KU, RB, PG

3'-0" O.H.
VERIFY LOCATIONS; SEE PLANS FOR BASIS OF DESIGN.
JS

10'-10 7/8"
8. DIMENSIONS SHOWN ON ROOF PLAN ARE FROM FACE OF STUDS TO ENDS OF ROOF CHECKED BY:
6'-0" SOFFIT VENT 18'-0" SOFFIT VENT 18'-0" SOFFIT VENT 6'-0" SOFFIT VENT

10'-6"
TRUSSES.

8" / 12"
8" / 12"
9. PROVIDE 3" CONTINUOUS ALUMINUM SOFFIT VENTS. VENTS MUST PROVIDE
12.7 SQ.IN. OF OPEN AREA PER LINEAR FOOT MINIMUM.
10. INSULATION BAFFLES SHALL BE INSTALLED IN SUCH A MANNER AS TO RESTRICT
D.S.
INSULATION FROM BLOCKING THE NATURAL VENTILATION OF THE ROOF.
11. PROVIDE KICK-OUT FLASHING WHERE ROOF INTERSECTS SIDEWALL.
D.S.

4" / 12"
12. PROVIDE 5" PREFINISHED ALUMINUM OGEE STYLE GUTTERS, TYP. WITH 5"

15'-0" SOFFIT VENT

15'-0" SOFFIT VENT


PREFINISHED ALUMINUM ROUND DOWNSPOUTS. QUANTITY AND LOCATION TO BE
DESIGN-BUILD. DOWNSPOUTS SHOWN IN PLAN ARE FOR REFERENCE ONLY.

ROOF FLASHING NOTES


AREA B-1 AREA B-5 AREA B-2 AREA B-3 AREA B-6 AREA B-4 1. PROVIDE 'D STYLE' METAL DRIP EDGE (COLOR TO MATCH FASCIA) AT ALL ROOF
EAVES AND RAKES - PER IBC 1507.2.9.3

11'-3 1/4"
8" / 12" 8" / 12" 2. PROVIDE A MULTI-STEP FLASHING SYSTEM AT ALL WALL/ROOF INTERSECTIONS
8" / 12" 8" / 12"
(EXAMPLE - CHEEK WALLS, CHIMNEYS, DORMERS, ETC)

30'-0" RIDGE VENT

30'-0" RIDGE VENT


3. EXTEND EAVE SELF-ADHERING WATERPROOFING UNDERLAYMENT A MINIMUM OF
8'-6" RIDGE VENT 22'-0" RIDGE VENT 22'-0" RIDGE VENT 8'-6" RIDGE VENT E23 24" UP THE ROOF SLOPE BEYOND THE INTERIOR FACE OF EXTERIOR WALL.
E23
74'-0"

68'-0"

68'-0"

74'-0"
3 4 4. 'WEATHER LAP' METAL FLASHING JOINTS A MINIMUM OF 2"
______________________ ______________________

A3.20 A3.20 5. LAP SELF-ADHERING WATERPROOFING PIECES A MINIMUM OF 6".


D.S. D.S.
6. ANY ROOFS WITH SLOPES BETWEEN 2/12 AND 4/12 ARE TO BE COMPLETELY
UNDERLAIDS WITH SELF-ADHERING WATERPROOFING UNDERLAYMENT.

11'-3 3/4"
11'-3 1/2"

7. APRON FLASHING AT FRONT CORNERS OF WALL/ROOF INTERFACES ARE TO BE 3060 Peachtree Rd. N.W.
SHOP MADE, RIVETED, AND SEALED Suite 600
8. WHERE BOTTOM OF DORMER WINDOWS ARE LESS THAN 6" ABOVE THE ROOF,
Atlanta, GA 30305
WINDOWS ARE TO HAVE PAN / APRON FLASHING.
9. PROVIDE MEMBRANE COUNTER FLASHING AT ALL METAL FLASHING CONDITIONS.
10. PROVIDE 72" WIDE SELF-ADHERING WATERPROOFING UNDERLAYMENT FROM T 404 365 7600
EDGE OF ROOF UP THE VALLEY FOR A MINIMUM OF 10' IN SHADED AND NORTH
ROOF LOCATIONS.
www.nilesbolton.com
15'-0" SOFFIT VENT

15'-0" SOFFIT VENT


ATTIC ACCESS PANEL; TYP.

ROOF LEGEND No. Description Date

4" / 12"
DRAFTSTOPPING; TYP. GMP SET 01/16/23
CONSTRUCTION SET 2/17/23 1
D.S.
RIDGE VENT (EXHAUST) PROVIDING 18 S.I. PER LINEAR FOOT 1 REVISION 1 5/1/23
D.S.
NET FREE AREA MIN. SEE DETAIL 1/A4.37 2 REVISION 2 06/23/23

10'-10 15/16"
8" / 12"
3 REVISION 3 08/02/23
8" / 12"
10'-6"

OFF-RIDGE VENT (EXHAUST) PROVIDING 150 S.I. NET FREE


ORV
3'-0" O.H.

3'-0" O.H.
AREA MIN. SEE DETAIL 8/A4.37
6'-0" SOFFIT VENT 18'-0" SOFFIT VENT 18'-0" SOFFIT VENT 6'-0" SOFFIT VENT
15'-0" SOFFIT VENT 15'-0" SOFFIT VENT
SOFFIT VENT (INTAKE) PROVIDING 12.7 S.I. PER SF NET FREE
AREA MIN.

D.S. D.S. E23 D.S.


D.S. D.S. D.S. 4" DIA. PREFINISHED ALUMINUM
OUTSIDE FACE OF STUD E20
4" 1'-0" 24'-0" 24'-0" 1'-0" 4" DOWNSPOUT LOCATION
BELOW, TYPICAL.
5" PREFINISHED ALUMINUM
2'-0" O.H. 141'-0" 2'-0" O.H. GUTTER
2
X:XX DIRECTION OF ROOF SLOPE-
145'-0" SEE GENERAL NOTES

2
______________________
OUTSIDE FACE OF STUD BELOW
A3.20 This drawing, as an instrument of service, is and shall
remain the property of the Architects and shall not
1-HOUR RATED ATTIC DRAFTSTOPPING PER WINDER, GEORGIA be reproduced, published or used in any way without
1 ROOF PLAN- BUILDING B CODE OF ORDINANCES SEC 9-61. SEE 6/A7.30 FOR DETAILS. the permission of the Architect.

A1.22 1/8" = 1'-0"


DRAFTSTOPPING DOOR, SEE DETAILS 11/A7.30

2
4'-0" WIDE 5/8" PLYWOOD WALKWAY, INSTALL OVER RAISED
BOTTOM CHORD OF TRUSS IN CORRIDORS; SEE DETAIL 17/A7.30

THE GATEWAY AT UNIVERSITY APARTMENTS


1-HOUR RATED ATTIC ACCESS HATCH,FIELD VERIFY
LOCATION, SEE DETAIL 11/A7.30

ICE AND WATER SHIELD


SEE NOTE 2 ON THIS PAGE

PROVIDE CRICKET AT CORNERS AS NEEDED.

0 EXCHANGE BOULEVARD

TPA RESIDENTIAL GROUP


WINDER, GEORGA 30620
AIR HANDLING UNIT

NATURAL VENTILATION CALCULATIONS ROOF AREA PLAN ALL BUILDINGS OR INFORMATION SHOWN OR REFERENCED
OTHER THAN WHAT IS INDICATED ON THE ARCHITECTURAL
COVER SHEET IS FOR REFERENCE ONLY

1B 2B 3B

4C 5A 6B 7A
CODE- NATURAL VENTILATION ATTIC/ROOF 1/300 - BLDG TYPE E

VENTILATION
WT REQUIRED VENTILATION PROVIDED GRAND TOTALS CLUB 8C 9B 10A

SOFFIT RIDGE % OF VENT


TOTAL REQ. SOFFIT VENT RIDGE VENT # OFF OFF RIDGE/SIDE AREA AT 3'-0" TOTAL VENT
AREA B-1 AREA B-2 AREA B-3 AREA B-4 11A 12A
VENT: AREA (SF) x SOFFIT AREA (12.7 SI/LF RIDGE AREA (18 RIDGE/SIDE WALL VENT AREA BELOW RIDGE PROVIDED
NAME AREA (SF) 1/300 x 144 (SI) LENGTH (FT) NFA) LENGTH (FT) SI/LF NFA) WALL VENTS (144 SI) AREA (SI) CHECK Comments 2,724 1,725 1,725 2,724 ALL BUILDINGS OTHER THAN WHAT IS SHOWN
ON THE COVER SHEET FOR REFERENCE ONLY

AREA B-1 2723.73 SF 1307 in² 60'-0" 762 in² 30'-0" 540 in² 1 144 in² 47% 1446 in² 1 BLDG B AREA B-5 AREA B-6 SHEET TITLE:
AREA B-2 1725.00 SF 828 in² 36'-0" 457 in² 22'-0" 396 in² 0 0 in² 46% 853 in² 1 BLDG B 577 584
AREA B-3 1725.00 SF 828 in² 36'-0" 457 in² 22'-0" 396 in² 0 0 in² 46% 853 in² 1 BLDG B
ROOF PLAN-

RELEASED FOR CONSTRUCTION


AREA B-4 2723.73 SF 1307 in² 60'-0" 762 in² 30'-0" 540 in² 1 144 in² 47% 1446 in² 1 BLDG B
AREA B-5 577.13 SF 277 in² 12'-0" 152 in² 8'-6" 153 in² 1 144 in² 66% 449 in² 1 BLDG B BUILDING TYPE B
AREA B-6 583.59 SF 280 in² 12'-0" 152 in² 8'-6" 153 in² 1 144 in² 66% 449 in² 1 BLDG B

SHEET NUMBER:
NOTE: SEE ELEVATIONS FOR GABLE VENT LOCATIONS.
1
BASIS OF DESIGN PLUMBING CALCULATIONS FOR DOWNSPOUTS:
PER 2018 IPC SECTION 1106.1 THE 100 YEAR HOURLY RAINFALL RATE IS 3.5".
PER 2018 IPC SECTION 1106.3 THE VERTICAL LEADER SIZING BASIS OF DESIGN IS 3 1/2"x4", WITH A 192 GPM CAPACITY.
192 GPM/.0364 (GPM PER 1 SF WITH A RAINFALL RATE OF 3.5 INCHES PER HOUR) = 5,275 SF COVERAGE PER DOWNSPOUT.
A1.22
PROJECT TRUE
2 1
AREA PLAN- ATTIC NATURAL VENTILATION PLAN - BLDG TYPE B NORTH NORTH
A1.22 1" = 20'-0" 02/17/23