Enhanced 50 Series™
PG.05E.25.T.E
Connection Options
Micro
or Euro
Mini QD (body) Micro or Euro (Micro) (Micro)
Cable QD (body) QD
Version (pigtail)
Photoelectric Sensors
5-10
Enhanced 50 Series™
Thru-Beam 10 – 40V DC 500 ft. 0.1 – 250 ft. Infrared Source N/A N/A 6-foot Cable 1151E-6517
Extended Range (152m) (0.03 – 77m) Detector NPN/PNP no 1251E-6517
250 mA yes 1251E-8517
Source N/A N/A 4-pin Euro (Micro) 1151E-6547
Detector NPN/PNP no Connector 1251E-6547
250 mA yes 1251E-8547
Source N/A N/A 4-pin Euro (Micro) 1151E-6537
Detector NPN/PNP no Connector (pigtail) 1251E-6537
250 mA yes 1251E-8537
Source N/A N/A 4-pin Mini- 1151E-6507
Detector NPN/PNP no Connector 1251E-6507
250 mA yes 1251E-8507
Field of View: 2.4°
12 – 240V DC Source N/A N/A 6-foot Cable 1151E-6513
For a complete system, 24 – 240V AC Detector Isolated Output no 1251E-6513
order one Sensor and Solid-State Relay
one Detector 300 mA @
5
yes 1251E-8513
240V AC/DC
SPDT EM Relay no 1251E-6514
SENSORS
PHOTOELECTRIC
Wiring Diagrams (Pin numbers are for reference only, rely on pin location when wiring)
Operating Models Cable Models Mini-Connector Models Micro-Connector Models
Voltage (Face View Male Shown) (Face View Male Shown)
10 – 40V DC Thru-Beam
BR
Source (+) (+) (+)
Test In
BK (–) OV (–) OV
Test In
BU Test In
(–) OV
All others
BN (+) (+) (+)
Load
WH NPN PNP PNP
Load
BK Load
Load NPN Load
BU PNP (–) OV Load (–) OV NPN (–) OV
12 – 240V DC Thru-Beam
or Source L1 (+) L1 (+)
24 – 240V AC BR
L1 (+)
L2 (–)
Solid-State
5
Relay
BU
L2 (–)
L2 (–)
SENSORS
PHOTOELECTRIC
All others
with Isolated BR L1 (+) L1 (+) L2 (–)
AC/DC Output Isolated L2 (–)
WH Isolated AC/DC
AC/DC Output Output L1 (+)
BK Isolated
BU L2 (–) AC/DC Output
12 – 240V DC Thru-Beam
or Source L1 (+) L1 (+)
24 – 240V AC BR
L1 (+)
L2 (–)
SPDT EM
Relay
BU
L2 (–)
L2 (–)
All others
BR L1 (+) L1 (+) L2 (–)
OR COM
WH
N.C. L2 (–)
BK COM COM
N.O. L1 (+)
BU N.O. N.C. N.O. N.C.
L2 (–)
Connect load to appropriate output for either sinking or sourcing operation.
Connecting the Test input to 0V DC allows you to switch the light source off for troubleshooting while leaving the sensor under power.
Over current protection is to be provided in the field. Conductor size for 20 AWG: 5 amp; 22 AWG: 3 amp; 24 AWG: 2 amp.
Specifications
AC/DC AC/DC DC Only DC Only
EM Relay Models Solid-State Relay Standard Range Extended Range
Models Models Models
Specifications (Continued)
AC/DC AC/DC DC Only DC Only
EM Relay Models Solid-State Relay Standard Range Extended Range
Models Models Models
PHOTOELECTRIC
Timer Timing Response 0 – 15 sec.
No Load Current <30 mA
SENSORS
Leakage Current (max.) — 1 mA @ 240V AC <10 µA
Indicator LEDs Green: Output; Yellow: Power; Red: Alignment
Emitter LED Diffuse, Infrared Fiber Optic, Thru-Beam Models: Infrared 880 mm
Reflex, Polarized Reflex, Clear Object, Visible Fiber Optic Units: Visible Red 660 mm
5
Cable and Pigtail Clear Object Versions Mini-Connector
Connector Versions 1.91
3.13 Versions 1.91
(48.5) (48.5)
(79.5)
1.81 1.42 1.81 1.42 1.81 1.42