Table 2-1.14: MV5-X2345(2405, 2460)W/V2DN1 specifications HP 84 86 88 Model name (Combination unit) MV5-X2345W/V2DN1 MV5-X2405W/V2DN1 MV5-X2460W/V2DN1 Combination type 18HP+22HP×3 20HP+22HP×3 22HP×4 Power supply 3 phase, 220V, 60Hz kW 234.5 240.5 246 Capacity kBtu/h 800 820.5 839.2 Cooling1 Power input kW 62.15 63.84 65.78 EER 3.77 3.77 3.74 kW 263 270 276 Capacity kBtu/h 897.3 921.1 941.6 Heating2 Power input kW 64.54 66.66 68.49 COP 4.07 4.05 4.03 Connected Total capacity 50-130% of outdoor unit capacity indoor units Maximum quantity 64 Type DC inverter Quantity 8 Compressors Oil type FV68H Start-up method Soft start
Part 2 - Outdoor Unit Engineering Data
Type Propeller Motor type DC Quantity 8 (520+440)+(550+430)+ (550+430)+(550+430)+ (550+430)+(550+430)+ Motor input W Fans (550+430)+(550+430) (550+430)+(550+430) (550+430)+(550+430) (420+350)+(440+350)+ (440+350)+(440+350)+ (440+350)+(440+350)+ Motor output W (440+350)+(440+350) (440+350)+(440+350) (440+350)+(440+350) Airflow rate m3/h 64000 Drive type Direct Type R410A Refrigerant Factory charge kg (lbs.) 13+16×3 (29+35×3) 16×4 (35×4) 16×4 (35×4) Liquid pipe mm (in.) Φ25.4 (Φ1) Pipe Gas pipe mm (in.) Φ44.5 (Φ1-3/4) connections3 Oil balance pipe mm (in.) Φ6.35 (Φ1/4) Sound pressure level4 dB(A) 70 mm (1340×1635×790)×4 Net dimensions (W×H×D) in. (52-3/4×64-3/8×31-1/8)×4 mm (1405×1805×855)×4 Packed dimensions (W×H×D) in. (55-3/8×71-1/16×33-5/8)×4 305+340×3 Net weight kg (lbs.) 340×4 (750×4) 340×4 (750×4) (673+750×3) 323+358×3 Gross weight kg (lbs.) 358×4 (790×4) 358×4 (790×4) (712+790×3) Operating temperature range °C (°F) Cooling: -5 to 48 (23 to 118.4); heating: -20 to 24 (-4 to 75.2) High/low pressure switch, fan driver overload protector, overcurrent relay, inverter Safety devices overload protector, overvoltage protector Standard accessories Installation manual, operation manual, connection pipes, clamps Notes: 1. Indoor air temperature 27°C (80.6°F) DB, 19°C (66.2°F) WB; outdoor air temperature 35°C (95.0°F) DB; equivalent refrigerant Conversion Formulae: piping length 7.5m (24.6ft.) with zero level difference. kBtu/h = kW × 3.412; 2. Indoor air temperature 20°C (68.0°F) DB; outdoor air temperature 7°C (44.6°F) DB, 6°C (42.8°F) WB; equivalent refrigerant in.W.G. = Pa × 0.004; piping length 7.5m (24.6ft.) with zero level difference. lbs. = kg × 2.2; 3. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems in. = mm / 25.4 with total equivalent liquid piping lengths of less than 90m (295.2ft). For systems with total equivalent liquid piping lengths of 90m (295.2ft) or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters.. 4. Sound pressure level is measured at a position 1m (3.28ft.) in front of the unit and 1.3m (4.26ft.) above the floor in a semi-anechoic chamber.