Table 2-1.12: MV5-X2010(2070, 2125)W/V2DN1 specifications HP 72 74 76 Model name (Combination unit) MV5-X2010W/V2DN1 MV5-X2070W/V2DN1 MV5-X2125W/V2DN1 Combination type 10HP+18HP+22HP×2 10HP+20HP+22HP×2 10HP+22HP×3 Power supply 3 phase, 220V, 60Hz kW 201 207 212.5 Capacity kBtu/h 685.7 706.2 724.9 Cooling1 Power input kW 51.93 53.62 55.55 EER 3.87 3.86 3.83 kW 225.5 232.5 238.5 Capacity kBtu/h 769.4 793.2 813.7 Heating2 Power input kW 53.36 55.48 57.31 COP 4.23 4.19 4.16 Connected Total capacity 50-130% of outdoor unit capacity indoor units Maximum quantity 64 Type DC inverter Quantity 7 Compressors Oil type FV68H Start-up method Soft start
Part 2 - Outdoor Unit Engineering Data
Type Propeller Motor type DC Quantity 7 (580)+(520+440)+ (580)+(550+430)+ (580)+(550+430)+ Motor input W Fans (550+430)+(550+430) (550+430)+(550+430) (550+430)+(550+430) (465)+(420+350)+ (465)+(440+350)+ (465)+(440+350)+ Motor output W (440+350)+(440+350) (440+350)+(440+350) (440+350)+(440+350) Airflow rate m3/h 60000 Drive type Direct Type R410A Refrigerant 9+13+16×2 9+16×3 9+16×3 Factory charge kg (lbs.) (20+29+35×2) (20+35×3) (20+35×3) Liquid pipe mm (in.) Φ25.4 (Φ1) Pipe Gas pipe mm (in.) Φ44.5 (Φ1-3/4) connections3 Oil balance pipe mm (in.) Φ6.35 (Φ1/4) Sound pressure level4 dB(A) 69 mm (990×1635×790)+(1340×1635×790)×3 Net dimensions (W×H×D) in. (39×64-3/8×31-1/8)+(52-3/4×64-3/8×31-1/8)×3 mm (1090×1805×860)+(1405×1805×855)×3 Packed dimensions (W×H×D) in. (42-7/8×71-1/16×33-7/8)+(55-3/8×71-1/16×33-5/8)×3 219+305+340×2 219+340×3 219+340×3 Net weight kg (lbs.) (483+673+750×2) (483+750×3) (483+750×3) 234+323+358×2 234+358×3 234+358×3 Gross weight kg (lbs.) (516+712+790×2) (516+790×3) (516+790×3) Operating temperature range °C (°F) Cooling: -5 to 48 (23 to 118.4); heating: -20 to 24 (-4 to 75.2) High/low pressure switch, fan driver overload protector, overcurrent relay, inverter Safety devices overload protector, overvoltage protector Standard accessories Installation manual, operation manual, connection pipes, clamps Notes: 1. Indoor air temperature 27°C (80.6°F) DB, 19°C (66.2°F) WB; outdoor air temperature 35°C (95.0°F) DB; equivalent refrigerant Conversion Formulae: piping length 7.5m (24.6ft.) with zero level difference. kBtu/h = kW × 3.412; 2. Indoor air temperature 20°C (68.0°F) DB; outdoor air temperature 7°C (44.6°F) DB, 6°C (42.8°F) WB; equivalent refrigerant in.W.G. = Pa × 0.004; piping length 7.5m (24.6ft.) with zero level difference. lbs. = kg × 2.2; 3. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems in. = mm / 25.4 with total equivalent liquid piping lengths of less than 90m (295.2ft). For systems with total equivalent liquid piping lengths of 90m (295.2ft) or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters.. 4. Sound pressure level is measured at a position 1m (3.28ft.) in front of the unit and 1.3m (4.26ft.) above the floor in a semi-anechoic chamber.