Professional Documents
Culture Documents
1208e2 Acad B04 05 BS Mech SD HV M 0001 01
1208e2 Acad B04 05 BS Mech SD HV M 0001 01
B04 B04 B04 B04 B04 B04 B04 B04 B04 B04 B05 B05 B05 B05 B05 B05 B05 B05 B05 B05
GENERAL NOTES
A 1. ALL MECHANICAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH GENERAL NOTES,
B04 MISCELLANEOUS DETAILS, ARCH/STRUCTURAL DRAWINGS AND SPECIFICATIONS.
2. PROVIDE FIRE /SMOKE FIRE DAMPERS WHERE DUCTS OR AIR GRILLES PENETRATE
SAD 2000x1300mm
FOR BASEMENT VENTILATION
PARTITION AND FLOOR REQUIRED TO HAVE A FIRE RESISTANCE RATING OF TWO HOURS OR
MORE. AND AS PER " NFPA " REQUREMENT.
3. ALL DUCT SIZES MENTIONED ON PLANS ARE CLEAR SIZES, EXCLUDING THE THICKNESS
FAD 500x350mm
FOR BASEMENT VENTILATION
OF INSULATION, AND OTHER DUCT LINING.
4. ANY CHANGE IN DUCT OR GRILL SIZES IS DUE TO COORDINATION WITH OTHER TRADES,
VRF PIPE SIZES SHALL BE PRESENTED UPON APPROVAL WHILE THE MAIN LINES
ARE COORDINATED WITH ALL TRADES.
EG 350x200 EG 350x200 5. DUCTWORK, FITTINGS, HANGERS AND ACCESSORIES SHALL BE AS PER SMACNA
123 L/S 123 L/S
1580 RECOMMENDATIONS.
ELEC. ROOM
ELEC. ROOM B-031 6. WALL AND ROOF OPENINGS SHALL BE 13 mm LARGER ALL AROUND THAN DUCT OR FIRE
FD FD
B-003
STAIR NO.8 DAMPER SLEEVE PASSING THROUGH WALL OR SLAB AND THE VOID WILL BE FILLED WITH
EF-12 EF-12
MFD EAD 300x150mm EAD 300x150mm MFD
EAD 300x150mm
825
B-034 NON-COMBUSTIBLE MATERIAL, WITH FIRE RATING MATCH WITH FIRE ZONNING.
BOD=+3000 BOD=+3000
BOD=+3000
780 1670 EAD 300x150mm
BOD=+3000 RAD 500x300mm
1520
RAD 500x300mm
1670
7. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR GRILLES AND DOOR UNDERCUT SIZES
BOD=+4000 BOD=+4000
AND DETAILS.
B FD FD 8. PROVIDE SLEEVES WHERE PIPES PENETRATE WALLS AND SLABS.
B04 STAIR 1 DL 500x200
FD FD FD
DL 500x200
9. EXPOSED EQUIPMENT TO BE TROPICALIZED AND WEATHERPROOFED. CONTRACTOR
ELEVATOR LOBBY
B-001 1555 1805 1770 1555 B-030
VESTIBULE
B-033
SHALL COORDINATE WITH ARCHITECTS TO MAKE SURE THAT THE EQUIPMENT IS
CONCEALED BEHIND PARAPET WALLS.
VESTIBULE 10. VIBRATING EQUIPMENT SHALL BE PROVIDED WITH ISOLATORS TO PREVENT VIBRATION
B-002 TRANSMISSION.
C 11. ALL RETURN DUCT SHALL BE WITH BELL MOUSE AND WIRE MESH SCREEN.
B04 FD
12. ALL DUCTS CROSSING THROUGH FIRE ZONE TO ANOTHER SHALL BE FIRE RATED DUCT.
ELEV. LOBBY IU-05 IU-05
B-004 S.G 1000x350
533 L/S EACH
S.G 1000x350
533 L/S EACH
13. THE CONTRACTOR HAS TO PROVIDE THE VOLUME DAMPERS POSITIONS ON THE SHOP-
R.G 1000x350 R.G 1000x350
DRAWINGS WHEREVER IT NEEDED FOR BALANCING, SERVICING AND SHUTT OFF PURPOSES
HVAC.
SHAFT
A A
B04 B04
CASHIER
MECH.
DUCT
ELEC.
SHAFT
ELEVATOR
NO.6
GAS GAS
CABINET CABINET
B B
B04 B04
EL 100 750
PART 1 PART 2
FFL
C C
B04 B04
HVAC.
SHAFT
HVAC.
SHAFT
IT SHAFT
OPEN TO
ABOVE
HVAC. SHAFT
MECH.
DUCT
ELEVATOR
NO.7 ELEVATOR
NO.8
GAS IT SHAFT
CABINET
MECH.
DUCT MECH.
DUCT
D D
B04 B04
OPEN TO ABOVE
OPEN TO ABOVE
EL (REFER TO L.S DWG)
FPL
EL 100 450
FFL
EL 100 450
FFL
E E
B04 B04
F F
B04 B04
MECH. SHAFT
OPEN TO ABOVE
EL 100 750
FFL
EL 100 750
FFL
EL 100 750
FFL
OPEN TO ABOVE
PART 3 PART 4
EL 100 750
G FFL EL 100000 G
B04 FFL B04
HVAC.
HVAC. SHAFT
SHAFT OPEN TO
OPEN TO ABOVE
ABOVE
ELEC. SHAFT
OPEN TO ELEC. SHAFT
ABOVE OPEN TO
ABOVE
H H
B04 B04
ARCH . CONCRETE
J J
B04 B04
HVAC. ELEVATOR ELEVATOR ELEVATOR HVAC.
ELEVATOR GARBAGE SHAFT
SHAFT GAS NO.1 NO.2 CHUTE NO.4 NO.5
GAS
CABINET CABINET
ELEC. ELEC.
SHAFT SHAFT
B04 B04 B04 B04 B04 B04 B04 B04 B04 B04 B05 B05 B05 B05 B05 B05 B05 B05 B05 B05
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
K K
B04 B04
L L
B04 B04
SLOPE 8% SLOPE 8%
M M
B04 B04
B04 B04 B04 B04 B04 B04 B04 B04 B04 B04 B05 B05 B05 B05 B05 B05 B05 B05 B05 B05
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ENGINEER ACTION:
E A Approved
B04
B approved with comments
F
B04
PROJECT:
RAD 450x350mm
BOD=+4000
RAD 450x350mm
BOD=+4000 DR. YAHIA MOUSTAFA
HANGER ROD 10MM
Pump Drain Point
CU 05
DR. GIHAN MOSSAD
CU 05
LEAD CONSULTANT:
SA RA
AIR FILTER
B04 1225
UPS 1510
MFD EAD 650x350mm
BOD=+3500
EAD 650x350mm
BOD=+3500
RAD 500x300mm RAD 500x300mm RAD 500x300mm RAD 500x300mm
EAD 650x350mm
BOD=+3600
EAD 650x350mm
BOD=+3600
UPS 1060
BOD=+3000 BOD=+3000 BOD=+3000 BOD=+3000 MFD
B-008 B-028
WIRE MESH SCREEN
WIRE MESH SCREEN WASHER 2-IU-04
EAD 250x150mm
MFD EAD 250x150mm
2420
1890 2055
ClW MSD
1890 2055 2175
FAD 100x100mm
BOD=+3700
SERVICE LOBBY
EAD 250x150mm
MFD
STAIR NO.7
B-026
TO EF-05 TO EF-05
EL 94 800 BOD=+3500 315 2025
EF-10
EAD 650x350mm
BOD=+3600
B-022
725
EAD 250x150mm
BOD=+3000
EL 94 800
MAIN CONTRACTOR:
FFL CU 04 SAD 500x200mm 3170
SAD 500x200mm
BOD=+3500
CU 04
FFL
EG 350x200
845 BOD=+3500
105 LlS 2985
2-IU-05 705
ELEC. ROOM
EAD 650x350mm
2-S.G 1000x350
533 LlS EACH
RMU/TRANSFORMER
B-016
EG 700x200
210 LlS
2-IU-05
2-S.G 1000x350
533 LlS EACH 2335
ELEC. ROOM
DL 500x150
EG 350x200 JOIN VENTURE
BOD=+3500 RMU/TRANSFORMER 105 LlS
B-009 DL 500x150 FAD 150x100mm
BOD=+4025
2745
2-R.G 1000x350
B-018
2-R.G 1000x350 B-025
HASSAN ALLAM CONSTRUCTION
SERVICE LOBBY
STAIR NO.3 2400 MDB
EAD 300x250mm
BOD=+3500 GARBAGE ROOM
&
3000
IU-06
S.G 1250x300
B-012 B-013 B-017 B-019
EL 94 800
STAIR NO.6
B-021
RAD 550x300mm
CONSOLIDATED CONTRACTORS COMPANY
ELEVATOR LOBBY FFL RAD 550x300mm RAD 550x300mm BOD=+3000
600 LlS EACH 965
SAD 400x150mm
1315
B-020
SAD 400x150mm BOD=+5000 BOD=+5000
DL 250x150
OFFSHORE
R.G 1250x300 ELEVATOR LOBBY 2275 BOD=+3500
SU-04 STANDBY BOD=+3500 STORAGE
B-014 GARBAGE ROOM
1170 B-024
B-015 EF-11
IT ROOM
1050
2-IU-05
RETURN THROUGH AIR GAP
3460
1035
3570 IU-05
RETURN THROUGH AIR GAP
MEP MAIN CONTRACTOR:
B-010 MFD 2-EG 1300x250 EG 1300x400
L
1625
2480 2965 1035 1990 3585
IU-07
3-S.G 1500x250
650 LlS EACH
3-R.G 1500x250
Type of document :
3-SU-05 STANDBY
825
1205 2660
M.F.D
SHOP DRAWING
2965
M
B04
M.F.D
INTERNAL REVIEW:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B04 B04 B04 B04 B04 B04 B04 B04 B04 B04 B05 B05 B05 B05 B05 B05 B05 B05 B05 B05 Prep. SUR. MEP. STR. ARCH. FINISH. APP.