Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Contents

C 1.COMPANY PROFILE.............................................................................................................. 1
2.CERTIFICATIONS CREDENTIALS......................................................................................... 3
O 3.LPCB CERTIFIED PRODUCTS WIRING DIAGRAM................................................................. 7
4.JB-TB-TC5109 INTELLIGENT FIRE ALARM CONTROL PANEL............................................................. 9
N 5.JTY-GM-TC5161 INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR................................ 11
6.JTW-ZOM-TC5162 INTELLIGENT RATE OF RISE & FIXED TEMPERATURE HEAT DETECTOR............. 13
T 7.JTF-GOM-TC5163 SMOKE AND HEAT COMBINED DETECTOR............................................................ 15
8.TCMK5263 ADDRESSABLE SINGLE I/O MODULE................................................................. 17
E 9.J-SAP-TCSB5264 ANALOGUE ADDRESSABLE MANUAL CALL POINT.................................. 19
10.TCSG5266 ADDRESSABLE SOUNDER STROBE.................................................................. 21
N 11.TCMK5260 ADDRESSABLE LOOP ISOLATOR..................................................................... 23
12.TCMK5261 ADDRESSABLE SINGLE INPUT MODULE......................................................... 25
T 13.TCDZ517S SOUNDER BASE(ADDRESSABLE) .................................................................... 27
14.TCDZ518FS SOUNDER BASE(CONVENTIONAL) . .............................................................. 29
S 15.TCDZ516 ISOLATING BASE................................................................................................. 31
www.tcfiretech.com 16.TCFSH5231 WATER PROOF BOX FOR SOUNDER............................................................... 33
17.TCFSH5206 WATER PROOF BOX FOR SOUNDER STROBE................................................ 34
COMPANY PROFILE
5G alters the world
Tiancheng changes life

Tiancheng Fire Protection Equipment Co., Ltd (hereinafter referred as to TC)


specializes in design and manufacture of high quality fire protection solutions for
commercial, industrial and domestic applications. We have nearly 30 years experience
in the field of fire protection industry.
Everlasting desire for innovation drives our company's product development
progress. We are continuously exploring new technologies that help us live in a smart
world. Smart TC makes a more connected and caring place, where resources are
valued, where impact of the wold is considered, where sustainable energy is delivered
reliably and efficiently.
TC adopts advanced technologies: IoT, big data, cloud computing to launch its Smart
TC series including “Smart Fire Protection”, “Smart Home Safety” with different
APPs available. TC is certified by ISO9001, ISO14001 and ISO18001. Our products
are certified by CCCF, LPCB, CE and GOST. Our corporate philosophy is based on
high quality, high efficient service and reasonable prices. TC is the first and only in
China that holds a Product Lifetime Warranty. TC has reached a leading position
in the market for professional fire protection, with 32 domestic branches in major
cities, such as Beijing, Shanghai, Chengdu, Guangzhou, Shenzhen, Nanjing, etc.,and
4 branches overseas in Noida India, Dubai UAE, Ho Chi Minh City Vietnam, Moscow
Russia, besides a network of partners and distributors. Combining TC's brand, capital,
technology and management advantages in domestic and international markets, TC
is committed to providing customers with comprehensive and efficient one-stop fire
protection solutions, improving the overall quality of life and driving the development
of modern cities.
3 > 4

> CERTIFICATIONS

LPCB EN54 EAC CE


5 > ABOUT US 6

PATENTS

EN

Y
OR
E

T
RP G L
RISE

ISO 14001 ISO 45001 ISO 9001


Environmental Management Occupational Health And Quality Management System
System Safety Management System Certificate Of Conformity
7 > LPCB PRODUCTS 8

LPCB Certified Products


Wiring Diagram
9 > LPCB PRODUCTS 10

▪ Intelligent bus control mode; max 255 addressable points per loop, max 4 loops, max 48 zones

> JB-TB-TC5109 ▪ Loop card type design:1-4 loop cards can be selected


▪ Glass fuse per loop
ADDRESSABLE FIRE ALARM ▪ Black box function

CONTROL PANEL ▪ Independent controlling password for the specially needed gas recharging units
▪ Self-design loop protocol
EN54-2 Certified ▪ Wall-mounted structure, compact and exquisite
EN54-4 Certified ▪ Akzo outer coating; anti-corrosion
▪ Language: simplified Chinese, English, Turkish and Russian(cus to mized)

The control panel is mounted on the BS3、BP3、AS3、AP3:

BP4 BS4 BP3 BS3


AP4 AS4 AP3 AS3
wall through 4 mounting holes, the Loop Signal Bus Loop 3; P is positive. S is negative.
dimensions of the mounting holes are
BS4、BP4、AS4、AP4:
Items Technical specifications shown in the picture. The right side of the
Loop Signal Bus Loop 4; P is positive. S is negative.
Voltage AC230V(50HZ),Voltage range:+10%~-15% control panel has 8 wiring holes, which
Current 1A are easy for wiring between the control BS1, BP1, AS1, AP1:

A1 GZ11 GZ21 RGND RGND BP2 BS2 BP1 BS1


HI- CANL CANH AP2 AS2 AP1 AS1
Standby battery 12V/12AH sealed lead acid battery*2 panel and field devices.There are also 5 Loop Signal Bus Loop 1; P is positive. S is negative.

LCD screen size 7-inch color LCD screen knock holes at the top, if the holes on the BS2、BP2、AS2、AP2:
Temperature:-5℃ ~+50℃ ;Relative Humidity: ≤ 95% right side are not enough.
Operating Environment Loop Signal Bus Loop 2; P is positive. S is negative.
non-condensing
Capacity 1020/4 loops addressable points CAN:networking terminal

Communication Interface RS485、CAN、USB output


Dimension(L×W×H) 420mm×140mm×560mm Fire output
Outputs Fire output.Fault output.24V power output.Loop output Fault

HI+
L、N PE AC220V
L, N, PE,AC 220V terminal
RS485 output

A2
and AC ground terminal;

B1
B2
GND 24V
Power output
11 > LPCB PRODUCTS 12

JTY-GM-TC5161
> ADDRESSABLE PHOTOELECTRIC
▪ Infrared scattering principle
▪ Non-polarized two-wire
SMOKE DETECTOR ▪ Drift compensation and fault detecting function

EN54-7 Certified

1. Base of the detector is shown in Fig. 3. There


Items Technical specifications are 2 conductor pieces with terminals on the
Operating voltage Loop 24V(18.5V~26V)
base. Detector’s loop should be respectively
Operating current Standby current: ≤ 0.3mA;Alarm current: ≤ 0.8mA
Temperature:-10℃ ~+55℃ ,Relative Humidity: ≤ 95% co n n e cte d w i t h t w o te r m i n a l s ( p o l a r i t y -
Operating Environment
non-condensing insensitive).After the base is fixed firmly, rotate
Ingress protection rating IP23
the bottom of detector and base clockwise, and
Material and color of enclosure ABS;Milky white
Coding method Electronically coding then the detector will be fitted to the base.
Code range 1~255
Weight About 110g
2. 1.0mm2 or above fire cable, subject to local
Mounting hole distance 60mm
Dimension 100mm×51mm(with base) codes.
Maximum transmission distance 1000m
13 > LPCB PRODUCTS 14

> JTW-ZOM-TC5162 ▪ Advanced single-chip microcomputer technology

ADDRESSABLE RATE OF RISE ▪ Non-polarized two-wire

& FIXED TEMPERATURE HEAT ▪ Thermal sensitive element improves the response speed of

DETECTOR temperature variation


EN54-5 Certified

1. Fix the base with two tapping screws, and then


connect loop to terminals (polarity-insensitive).
Items Technical specifications After the base is fixed firmly, rotate the bottom
Operating voltage Loop 24V(18.5V~26V) of detector and base clockwise, and then the
Operating current Standby current: ≤ 0.3mA;Alarm current: ≤ 0.8mA detector will be fitted to the base.
Temperature:-10℃ ~+55℃ ,Relative Humidity: ≤ 95%
Operating Environment
non-condensing
2. Wiring instructions: RVS twisted pair with cross-
Ingress protection rating IP33
sectional area ≥ 1.0mm2 should be selected for
Material and color of enclosure ABS;Milky white
Coding method Electronically coding the second bus of the detector, which should
Code range 1~255 be laid through metal pipe or flame retardant
Weight About 110g pipe. The length of the connecting wire should
Mounting hole distance 60mm be limited to the single bus resistance ≤ 20Ω,
Dimension 100mm×51mm(with base) otherwise the wire diameter should be increased.
Maximum transmission distanle 1000m
15 > LPCB PRODUCTS 16

> JTF-GOM-TC5163 ▪ Single chip uses real-time sampling and data processing system.

SMOKE AND HEAT COMBINED ▪ Temperature and humidity drift compensation, dust accumulation

DETECTOR degree and fault detection function.


▪ Self-diagnostic function.
EN54-5 Certified ▪ Non-polarized signal 2-wire.

EN54-7 Certified

1. There are 2 conductor pieces with terminals on


the base.
Items Technical specifications Loop of the detector should be connected with
Operating voltage Signal bus voltage: loop 24V(16~28V) two terminals (polarity-insensitive).
Operating current Standby current: ≤ 0.3mA;Alarm current: ≤ 0.9mA After the base is fixed firmly, rotate the bottom
The space height is 6~12 meters: 80m2 of detector and base clockwise, and then the
Monitoring area
The space height is lower than 6 meters: 60m2 detector will be fitted to the base
Temperature: -10° C ~ +55° C
Operating environment
Relative Humidity: ≤ 95%, non-condensing 2. 1.0mm 2 or above RVS twisted pair, laid out
Weight About 110g through metal conduit or flame-resistant conduit.
Mounting hole distance 60mm
17 > LPCB PRODUCTS 18

TCMK5263
▪ Line detection function for input and output

> ▪ Input terminal is ste as normal open detecting function connected


with passive contalt
ADDRESSABLE SINGLE I/O MODULE ▪ Non-polarized two-wire
▪ Active and passive output

EN54-18 Certified

NO Contact
output control

NC Contact

Items Technical specifications


Operating voltage Loop:24V(18.5V~26V);Power:DC24V(DC19V~DC28V)
Standby current Loop: ≤ 0.2mA;Power:≤ 2mA
Starting current Loop: ≤ 2mA;Power: ≤ 22mA
Temperature:-10℃ ~+55℃ ; 24V Output NC/NO Output
Operaing Environment Relative Humidity: ≤ 95%
non-condensing Feedback input terminal has disconnection detection function, add a 10K
Passive:Capacity:DC30V/3A; terminal resistance at one end, otherwise it will report as product feedback terminal
Contact resistance in normal condition:100kΩ; fault. Output line has disconnection and short line detection function, when module
Output capacity Closed when activated; does no action, voltage between DC13V to 48V is required at normal open output
Suitable for DC or AC12V~48V; terminal otherwise it will report as module output line fault.
Active output:DC24V/1.5A Open installation applied for the module. Insert mode for installation between
Coding method Electronically coding base and module. When installing, pull down the module, lead the wire through
Code range 1~255 wiring hole, connect it with terminal and push the module onto the base. The
Material and color of enclosure ABS; Porcelain white
mounting hole distance is 60mm.
Weight About 147g(with base)
Mounting hole distance 60mm
Dimension(L×W×H) 86mm×38mm×86mm(with base)
19 > LPCB PRODUCTS 20

J-SAP-TCSB5264
▪ Plug-in structure .Simple and convenient instauation

> ▪ Alarm by pressing, reset by a special key


▪ Non-polarized two-wire to the control panel
ANALOGUE ADDRESSABLE MANUAL ▪ Reusable
CALL POINT

EN54-11 Certified

1. The MCP is mounted inside the wall. Unplug the

point, put cables into the base’s entrance hole


Items Technical specifications
Operating voltage Loop 24V(18.5V~26V) and connect corresponding terminals.
Operating current Standby current: ≤ 0.2mA;Alarm current: ≤ 0.8mA
Temperature:-10℃ ~+55℃
Operating Environment 2. Wiring instructions: BS,AS and BP,AP: two bus
Relative Humidity: ≤ 95% non-condensing
Coding method Electronically coding inputs of non-polarized signals.
Code range 1~255
Material and color of enclosure ABS;Red
Weight About 120g(with base)
Mounting hole distance 60mm
Dimension(L×W×H) 95mm×44mm×95mm(with base)
21 > LPCB PRODUCTS 22

TCSG5266
▪ Four wires:non-polarized signal two-wire, and non-polarized DC24V

> power two-wire
▪ Built-in microprocessor
ADDRESSABLE SOUNDER STROBE ▪ Self-diagnostic function
▪ Electronically coding

EN54-3 Certified

Items Technical specifications


1. Unplug the base.
Operating voltage Loop:24V(18.5V~26V);Power:DC24V(DC19V~DC28V)
Standby current Loop: ≤ 0.2mA;Power:≤ 0.5mA 2. Fix the base. Thread cable through entrance hole from the back of base; according to the words and
Active current Loop: ≤ 1.5mA;Power: ≤ 50mA directions of arrow around the entrance hole, fix the base.
Indoor(Non-residential);Temperature:-10℃ ~+50℃ ;
Operating Environment 3. The sounder strobe is mounted inside the wall. The base box and cover of the sounder strobe are
Relative Humidity: ≤ 95%(40±2℃ )
Sound level 90dB~115dB(A weighted) plugged together, surfaced mounted on 86H50 embedded box. The mounting hole distance is 60mm.
Pitch shift periodic 3.5S~4.5S
Basic flashing frequency 1Hz~2Hz
Weight 200g
Dimension(L×W×H) 140mm×55.3mm×115mm(with base)
23 > LPCB PRODUCTS 24

TCMK5260
▪ Polarized connection with peripheral devices and no need to

> transfer connection of input and output.


▪ Delayed power supply to output terminal devices will avoid
ADDRESSABLE LOOP ISOLATOR over load or strong transient current
▪ Plug-in structure
▪ Non-polarized two-wire
EN54-17 Certified

Items Technical specifications


Operating voltage Loop 24V(18.5V~26V)
Operating current Action current ≤ 170mA or 270 mA (B and ZX2 short circuit here) Take surface installation for the isolator, install the base upward of the arrow direction, plug-in for the
Load capacity Loop 24V,170mA;Loop 24V,270mA(B and ZX2 short circuit here) isolator to the base. Pull off the isolator, wear the cable through wiring hole on the base and connect
Indicator Yellow,light out in normal condition,Illuminates in action
correspondent terminal and plug in the isolator. Mounting hole distance is 60mm.
Temperature:-10℃ ~+50℃ ;
Operating Environment
Relative Humidity: ≤ 95%non-condensing
Wiring instruction:
Coding method Electronically coding
Material and color of enclosure ABS;Porcelain white BS(pin 5),AS(pin 8):loop negative; BP(pin 6),AP(pin 7):loop positive
Mounting hole distance 60mm The positive cable inserts from pin 7 and out from pin 6. The cable negative inserts from pin 8
Dimension(L×W×H) 86mm×41mm×86mm(with base) and out from pin 5. Please refer to control panel TC5109 terminal mark wiring. 5.6 Recommended
Ingress protection rating IP30 Cabling:1.0mm² or above fire cable,subject to local codes.
Weight 147g(with base)
25 > LPCB PRODUCTS 26

TCMK5261
▪ Designed to connect with active devices in field such as water

> flow indicator, pressure switch, position switch, signal valve


and devices able to transmit back switch signals
ADDRESSABLE SINGLE INPUT ▪ The built-in microprocessor processes messages intelligently
MODULE ▪ Plug-in structure
▪ Non-polarized two-wire
EN54-18 Certified

BS AS BS AS
BP AP BP AP

Items Technical specifications


Operating voltage Loop 24V(16V~28V)
Operating current Standby current: ≤ 0.2mA;Action current: ≤ 0.8mA The module and base adopts plug-in structure . Unplug the module, put cables into the entrance hole
Temperature:-10℃ ~+55℃ ;Relative Humidity: ≤ 95% and connect corresponding terminals. And then plug the module onto the base.
Operating Environment
non-condensing L1 (7), L2 (8): Non-polarized signal bus input terminal .
Code range 1~255 AS1 (9), AS2 (10): passive input, connect passive normally open contact (alarms when device's action
Material and color of enclosure ABS;Porcelain white closes);
Weight About 110g(with base) It can also be set to normally closed input by using hand-held Encoder.
Mounting hole distance 60mm Signal bus L1 and L2 adopt RVS twisted pair, and cross section ≥ 1.0mm²; AS1 and AS2 adopt RV wire,
Dimension(L×W×H) 86mm×38mm×86mm(with base)
and cross section ≥ 1.0mm². The length of connecting cables should be limited to a signal wire's
resistance ≤ 20Ω,or increase the cable diameter.
27 > LPCB PRODUCTS 28

> TCDZ517S
SOUNDER BASE(ADDRESSABLE)
▪ Non-polarized
EN54-3 Certified
▪ Reliable and low power
▪ Strong anti-interference
▪ Easy to wire and commissioning
▪ Addressable makes it meet more on-site require ments

Items Technical specifications


Operating voltage Loop: 24V(18.5V~26V)
Standby current Loop: ≤ 0.15mA
Active current Loop: ≤ 4mA
Indoor(non-residential); Temperature: -10℃ ~+50℃ ;
Operating environment
Relative humidity: ≤ 95%(40±2℃ )
Sound level 90dB@3m
Pitch shift periodic 3.5s~4.5s
29 > LPCB PRODUCTS 30

> TCDZ518FS
SOUNDER BASE(CONVENTIONAL) ▪ Non-polarized
▪ Reliable and low power
EN54-3 Certified
▪ Strong anti-interference
▪ Easy to wire and commissioning
▪ Does not have an address of its own

Items Technical specifications


Operating voltage Loop: 24V(18.5V~26V)
Standby current Loop: ≤ 0.23mA
Active current Loop: ≤ 4mA
Indoor(non-residential); Temperature: -10℃ ~+50℃ ;
Operating environment
Relative humidity: ≤ 95%(40±2℃ )
Sound level 90dB@3m
Pitch shift periodic 3.5s~4.5s
31 > LPCB PRODUCTS 32

> TCDZ516
▪ Built-in isolator
ISOLATING BASE ▪ Non-polarized
EN54-17 Certified ▪ Reliable and low power
▪ Strong anti-interference
▪ Easy to wire and commissioning

Items Technical specifications


Vmax 28V
Vnom 27V
Vmin 19V
ISO max 600mA
ISO min 240mA
ISC max 21mA
ISC min 9mA
IS max 2A
IL max 26MA
ZC max 350mΩ
33 > LPCB PRODUCTS 34

> TCFSH5231 > TCFSH5206
WATER PROOF BOX FOR WATER PROOF BOX FOR
MODULE AND MCP SOUNDER STROBE

Items Technical specifications Items Technical specifications


Ingress protection rating IP67 Ingress protection rating IP67
Material and color of enclosure ABS Material and color of enclosure ABS
Dimension(L×W×H) 147mm×119mm×79mm Dimension(L×W×H) 185mm×185mm×75mm
LIAONING YINGKOU TIANCHENG FIRE PROTECTION EQUIPMENT CO.,LTD.

Address: No. 11-2 Kechechang Xili, Xishi District, Yingkou Pilot Free
Trade Zone (Liaoning) China
Postcode: 115004
Email: info@tcfiretech.com
Website: www.tcfiretech.com
All rights reserved. If the version of this manual is updated, the
latest version shall prevail.
Ver. 2021.01

RUSSIA BRANCH
Address:117041, РОССИЯ, ГОРОД МОСКВА, УЛИЦА АДМИРАЛА РУДНЕВА,
ДОМ 4, ЭТАЖ 6, ПОМ 5, КОМНАТА 7-13
E-mail:Russia@tcfiretech.com
DUBAI BRANCH
Address:Business Center Dubai World Central P.O.BOX:390667 Dubai-UAE
E-mail:Dubai@tcfiretech.com
VIETNAM BRANCH
Address:29 Nguyen Van Mai,Ward 08,District 3,Ho Chi Minh City,Vietnam
E-mail:Vietnam@tcfiretech.com

You might also like