Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PLUMBING FIXTURES

CONNECTIONS
SYMBOL DESCRIPTION SPECIFICATIONS REMARKS
W V CW HW

KOHLER HIGHCLIFF K-96057. (1.28 GPF) WHITE VITREOUS CHINA
WATERCLOSET -
FLOOR MOUNTED ELONGATED. 12" ROUGH-IN, 16 7/8" RIM HEIGHT,
FLOOR MOUNTED - FLUSH
P-1 3" 2" 1" --- FULLY GLAZED TRAPWAY, AND BOLT CAPS. SEAT SHALL BE WHITE,
VALVE
LUSTRA K-4650-A. FLUSH VALVE SHALL BE SLOAN OPTIMA PLUS
(ADA COMPLIANT)
8111-1.28 (HANDS FREE).

KOHLER BARDON HIGH EFFICIENCY URINAL MODEL K-4991-ET-0.


FLUSH VALVE SHALL BE SLOAN OPTIMA PLUS 8111-0.125 (HANDS
P-2 URINAL 2“ 2" 3/4" --- FREE). CARRIER SHALL BE COATED STEEL, FLOOR-MOUNTED WITH
˚
ADJUSTABLE SUPPORT PLATES, MOUNTING BOLTS, AND TRIM.
MTI BATHS BOUTIQUE COLLECTION SINKS LUNA 15-3/4"x51/4" ROUND
SCULPTURESTONE VESSEL BATHROOM SINK WITH FLAT RIM. FAUCET
SHALL BE KOHLER PURIST WALL MOUNT BATHROOM SINK FAUCET
LAVATORY,
˚ P-3 2" 1-1/2" 1/2" 1/2" K-T14414-3 PROVIDED WITH KOHLER K-410-K WALL-MOUNT VALVE
COUNTER MOUNT
DRAIN SHALL BE MTI BATHS FINGER TOUCH DRAIN WITHOUT
OVERFLOW MODEL DKFGCN. P-TRAP SHALL BE ZURN Z1021-PC WITH
INTEGRAL TRAP PRIMER, 1-1/4"X1-1/2" WITH ESCUTCHEON.
ELECTRIC WATER COOLER,
P-4 2" 1-1/2" 1/2" --- ELKAY MODEL - LZ00TL8WSSK
ADA-COMPLIANT
P-5 MOP SINK 2" 1-1/2" 1/2" 1/2" METRO MODEL 1842NS WITH ELKAY FAUCET (MODEL LKB940C).

FD 'A' JR SMITH DX2005 WITH NICKEL-BRONZE TOP (5" SQUARE STRAINER),


FLOOR DRAIN 2" --- --- ---
NO-HUB OUTLET

ELECTRIC WATER HEATER SCHEDULE

STORAGE RECOVERY @ 90
NO OF ELECTRICAL INPUT
” MARK LOCATION TYPE CAPACITY °F RISE NOTES MANUFACTURER MODEL NO
ELEMENTS
GAL GPH TOTAL kW

EWH-1 MECHANICAL ELECTRIC 50 37 2 9 1,2,3,4,5 AO SMITH DRE-52



NOTES (APPLICABLE THIS SCHEDULE):

CENTER POINT CHURCH


1 SEE ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS. DISCONNECT BY ELECTRICAL. KW CAPACITY SHOWN IS AT PROJECT VOLTAGE
2 HOT WATER STORAGE TEMPERATURE SHALL BE 140F. PROVIDE MIXING VALVE TO REDUCE SUPPLY TEMPERATURE TO 104F.

KATHLEEN, GA 31047
3 PROVIDE WITH GLASS-LINED TANK, SACRIFICIAL ANODE, AND MINIMUM FIVE YEAR WARRANTY.
4 PROVIDE WITH INTERNAL DIP TUBE AND PRESSURE RELIEF VALVE. PIPE RELIEF VALVE DISCHARGE TO SAFETY PAN BELOW HEATER.
5 TOTAL KW IS BASED ON THE OPERATION OF ALL ELEMENTS.

2440 GA-127
INSTANTANEOUS WATER HEATER SCHEDULE
NO OF ELECTRICAL INPUT
MARK LOCATION TYPE TEMP CHANGE AT NOTES MANUFACTURER MODEL NO
ELEMENTS
TOTAL kW VOLT / PH

IWH-1 215 - R.R. ELEC 71oF AT 0.4 GPM 1 4.16 208/ / 1 1 CHRONOMITE SR-20L/208

IWH-2 JANITOR ELEC 28oF AT 2 GPM 1 8.3 208 / 1 1 EEMAX SPEX8208TS


NOTES (APPLICABLE THIS SCHEDULE):
1 SEE ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS. DISCONNECT BY ELECTRICAL. KW CAPACITY SHOWN IS AT PROJECT VOLTAGE

PUMP SCHEDULE
FLOW HEAD TEMPERATURE NOMINAL POWER
MARK LOCATION SYSTEM TYPE SPEED CONTROL NOTES MANUFACTURER MODEL
GPM FT °F HP
MECHANICAL AND
CP-1 EWH-1 INLINE 3 3.5 104 1/40 CONSTANT 1,2 TACO 003-ST4
ELECTRICAL
NOTES (APPLICABLE TO THIS SCHEDULE)
POWER CORD CONNECTED TO PUMP SHALL BE A ONE PIECE CORD. NO EXTENSIONS SHALL BE USED. UNIT SHALL BE RATED FOR 115V ELECTRICAL OUTLET AND HAVE A
1
THREE PRONG CONNECTION.
2 PROVIDE WITH AQUASTAT CONTROL TO REGULATE TEMPERATURE AT A SETPOINT.

No. Description Date


--

02.17.2023

GENERAL
INFORMATION

Project number 2253


Date 02.17.2023
Drawn by NWG
Checked by GWL

P0.1
Scale As indicated