SIMATIC NET
Answers for industry.
© Siemens AG 2010
Industrial Ethernet
Industrial Ethernet Networking
With Totally Integrated Automation, Siemens is the only They are used for the structured networking of machines and
manufacturer to offer an integrated range of products and plants as well as for integrating them into the overall corpo-
systems for automation in all sectors – from incoming goods rate network. A graded portfolio of switches (SCALANCE X)
and the production process to outgoing goods, from the field and communications processors with integral switches
level through the production control level, to connection with enables optimum solutions for all types of switching tasks,
the corporate management level. SIMATIC NET offers all the not only in harsh industrial environments.
components for industrial communication: from industrial
communications processors right up to network components To assist in selecting the right Industrial Ethernet switches as
– even wireless if required. well as configuration of modular variants, the Switch Selec-
tion Tool is available as a free download at:
The ever expanding spread of Ethernet in the industrial envi-
ronment makes it increasingly important to structure the www.siemens.de/switchselection
resulting Industrial Ethernet/PROFINET networks.
Ethernet
C
e
us
fac
l W tio
ire n
AS
S
lec
IBU
OF
ntr
PR
every sector.
IO-Link
2 Industrial Ethernet
© Siemens AG 2010
Industrial communication differs fundamentally from the com- These requirements can only be satisfied when it is based on an
munication that is used in the office environment. In the office open, company-wide communication system that permeates
environment, many clients communicate with one server; there the entire company and extends beyond its boundaries. Island
are no cross-connections between clients. This type of data solutions are avoided in automation and information techno-
transmission can cause bottlenecks and delays when commu- logy, so the following preconditions must apply:
nication links are being established, when too many clients
access a server simultaneously. ■ Continuous flow of information from the actuator/
sensor level through to the corporate management level
This cannot be used for automation because cyclically executing
process programs require up-to-date input data in order to issue ■ Availability of information at every location
the appropriate control commands to components.
■ Fast exchange of data between the plant sections
Furthermore, applications, communications relationships and
network structures must be individually adapted to the harsh ■ Easy, plant-wide configuring and efficient diagnostics
industrial conditions.
■ Integrated security functions that block unauthorized
An industrial network must also be able to respond flexibly access
and at short notice to changing market requirements and
retooling must be fast and efficient. It must always be ensured, Totally Integrated Automation
however, that the capacity of the network and therefore the
plant or machines is optimally utilized and any downtimes The network and automation components of
minimized. All the production and management processes SIMATIC NET are part of Totally Integrated Automation (TIA), an
must perfectly interact. integrated range of products and systems for automation in all
areas – from incoming goods, through the production process
to outgoing goods, and from the field level, through to the
connection to the corporate management level. These com-
ponents feature the highest possible degree of integration be-
cause they access a common database which, in turn, saves
data entry costs and ensures consistency throughout the proj-
ect.
Industrial Ethernet 3
© Siemens AG 2010
Industrial Ethernet
Network performance and technologies
'DWDWKURXJKSXW
0ELWVIXOOGXSOH[ 0ELWV
0ELWVVZLWFKHG 0ELWV
0ELWVIXOOGXSOH[ 0ELWV
0ELWVVZLWFKHG 0ELWV
0ELWVVKDUHG 0ELWV
0ELWVIXOOGXSOH[ 0ELWV
0ELWVVZLWFKHG 0ELWV
*B,.B;;B
0ELWVVKDUHG 0ELWV
(IIHFWLYHGDWDWKURXJKSXWGXHWRFROOLVLRQV
Ethernet becomes Industrial Ethernet by adapting all the com- • Switching permits parallel communication:
ponents to provide the level of ruggedness and ease of use When a network is subdivided into several segments using
required in industrial applications. This is based fully on the a switch, this results in load separation. Data communica-
Ethernet standard IEEE 802.3 that includes the following basic tion is possible in each individual segment independently
technologies: of the other segments. In the overall network, several
message frames can therefore be en-route simultaneously.
• Fast Ethernet at 100 Mbit/s: The performance gain is due to the simultaneity of several
Message frames are transported much faster than by message frames.
Ethernet (10 Mbit/s) and therefore only occupy the bus for • Autocrossover automatically crosses the send and receive
an extremely short time. For Fast Ethernet, a 4-wire cables on twisted-pair interfaces.
FastConnect cabling system (Cat5e) is available with cable, • Autosensing describes the characteristic of network
plug and outlet. nodes (data terminals and network components) that
• Gigabit Ethernet at 1 Gbit/s: automatically detect the transmission rate of a signal
Gigabit Ethernet is faster than Fast Ethernet by a factor of (10 Mbit/s, 100 Mbit/s, or 1 Gbit/s) and support autone-
10, so the bus is occupied for only one tenth of the time. gotiation.
For Gigabit Ethernet, an 8-wire FastConnect cabling system • Autonegotiation is a configuration protocol.
(Cat6) is available with cable, plug and outlet. Before initiating the actual data transmission, network
• Full Duplex avoids collisions: devices automatically negotiate a transmission mode that
data throughput is increased hugely since the usual message all devices can use (10/100/1000 Mbit/s, full duplex or half
frame repetitions are avoided. Data can be sent and re- duplex).
ceived simultaneously between two nodes. The data
throughput for a full duplex connection therefore rises to
200 Mbit/s with Fast Ethernet and to 2 Gbit/s with Gigabit
Ethernet.
4 Industrial Ethernet
© Siemens AG 2010
boundaries
Industrial Ethernet 5
© Siemens AG 2010
Industrial Ethernet
Reliable networks thanks to redundancy
Fast redundancy
Extremely fast reconfiguration of the network in a ring follow- In an optical ring comprising 50 switches, the network will be
ing an error is indispensable for industrial applications, be- reconfigured after a fault (cable break or failure of a switch) in
cause the connected data terminals will otherwise disconnect less than 200 ms. The connected data terminals remain unaf-
logical communication links. This would result in a process fected by the changes in the network, and no logical connec-
running out of control or emergency shutdown of the plant. tions are cleared down. Control over the process or application
is assured at all times.
In order to achieve the very fast reaction times required, various
standardized procedures are used. The reconfiguration time in In addition to implementing high-speed media redundancy in
the network plays a crucial role here in avoiding breaks in con- the ring, SIMATIC NET switches also offer the functions re-
nection and the associated plant standstills. quired for high-speed redundant coupling of rings or network
segments. Network segments in rings or any other topology
can be coupled over two switches.
6
2SHUDWRU6WDWLRQ 3&
6
6
6&$/$1&(
;
3&
6
6&$/$1&( 6&$/$1&(
; ;
6
3&
6&$/$1&(;
3&
3&
6
6
*B,.B;;B
6
,QGXVWULDO(WKHUQHW 7ZLVWHG3DLU 6
6 Industrial Ethernet
© Siemens AG 2010
Redundancy with the standard Spanning Tree algorithm Optical cabling with POF/PCF or glass fiber-optic cable
The Spanning Tree algorithm is described in the IEEE 802.1d Fiber-optic cables are always recommended as an alternative
standard; it organizes any number of meshed Ethernet struc- to copper cables in environments subject to strong electromag-
tures comprising bridges and switches. netic interference (EMI), if reliable equipotential bonding can-
not be guaranteed, if the system is in the open air, or if EMI is
To prevent data packages circulating in the network, in the not desirable.
case of closed meshes different connections are switched to
standby so that an open tree structure results from the Glass fiber-optic cables are used to establish optical network
meshed structure. topologies covering long distances, while for shorter distan-
The switches communicate for this purpose using the Spanning ces, plastic fiber-optic cable made of light-conducting plastics
Tree protocol. This protocol is extremely complex because it like polymer optical fiber (POF), or plastic covered glass fibers
has to handle any type of network structure. such as polymer cladded fiber (PCF), are used. Simple fiber-
optic cabling for machine-level use is implemented with the
The organization of network structures with the Spanning SC RJ connection system for POF and PCF.
Tree protocol can take from 30 to 60 seconds. During this The SC RJ connectors can be assembled particularly quickly
period, productive communication for reliable visualization and easily on-site. The plastic fiber-optic cables designed for
or process control in the network is not possible. this purpose can be used universally or specifically in festoon
cable systems.
In the time-optimized variant "Rapid Spanning Tree" according
to IEEE 802.1, the time is shortened to a few seconds for up to For optical PROFINET networking, products with POF or PCF
10 series-connected switches. For connecting to office net- connection are used, e.g. the Industrial Ethernet Switch
works, some SCALANCE X switches, e.g. SCALANCE X-300, SCALANCE X200-4P IRT, ET 200S distributed I/O or the
support the Rapid Spanning Tree Protocol. SCALANCE X101-1POF media converter.
6
2SHUDWRU6WDWLRQ 3&
6
6
6&$/$1&(
;
3&
6
6
3&
6&$/$1&(
;
3&
3&
6
6
*B,.B;;B
Industrial Ethernet 7
© Siemens AG 2010
Industrial Ethernet
Reliable networks thanks to redundancy
Whereas in the field level, short response times and small data For these requirements, the switches of the SCALANCE X-300
message frames are in the forefront, the need for high data and SCALANCE X-400 families offer the relevant interfaces for
throughput is constantly increasing in the control level. The electrical and optical Gigabit Ethernet, as well as the neces-
reason for this is the fast growing number of nodes and more sary switching performance.
data-intensive systems such as HMI, SCADA, image processing
systems, web applications or multimedia applications. In addition to these infrastructure components, there are also
In addition to the Gigabit-enabled network infrastructure, gigabit-enabled communications processors available for PC
there are also Gigabit-enabled system connections available and SIMATIC S7. This enables direct, high-performance con-
for PC or SIMATIC S7-300/400. The CP 1623 communications nection of SCADA systems like WinCC to a Gigabit Ethernet.
processor for PCI Express supports a high-performance con- S7 controllers can also communicate with lower-level I/O de-
nection of the HMI/SCADA systems and simultaneously in- vices while simultaneously connected to higher-level gigabit
creases the reliability of the network by means of an optional structures.
external power supply.
Enterprise Level
1000 Mbit/s
Ethernet
Control Level WinCC
6&$/$1&( SCALANCE
;( X414-3E Server
with
SCALANCE CP 1623
SCALANCE
X308-2M PoE X408-2
1000 Mbit/s
1000 Mbit/s
IP camera SCALANCE
X308-2
1000 Mbit/s 1000 Mbit/s
SIMATIC S7-400
with 1000 Mbit/s
CP 443-1 Advanced IPC with
Gigabit interface
SIMATIC S7-300 and CP 1616
with
CP 343-1 Advanced
Field Level
PROFINET 100 Mbit/s
Industrial Ethernet
G_IK10_XX_10226
,QGXVWULDO(WKHUQHW 7ZLVWHG3DLU
,QGXVWULDO(WKHUQHW )LEHU2SWLF
Network separation between field level, control level and enterprise level including gigabit communication
8 Industrial Ethernet
© Siemens AG 2010
Network separation between corporate levels Configurations for integrating existing networks
The subdivision of the overall corporate network into different Existing network configurations that were constructed,
network levels is referred to as network separation. Reasons for example, using Industrial Ethernet switches OSMs (Optical
for network separation are deliberate load decoupling or Switch Modules) and ESMs (Electrical Switch Modules), can be
different responsibilities within an enterprise (e.g. office and easily expanded using SCALANCE X components.
production network).
Existing 100 Mbit/s data terminals or subnets with Fast
To nevertheless enable company-wide communication, either Ethernet up to 100 Mbit/s can be easily integrated into new
SCALANCE X414-3E or CP 343-1 Advanced/ network structures.
CP 443-1 Advanced communications processors with IP
routing functionality can be used at the interfaces between
the individual levels.
A configurable IP access list ensures additional network secu-
rity at the transition points between the network levels.
,QGXVWULDO(WKHUQHW
6,0$7,&6
ZLWK&3
$GYDQFHG )LHOG3*
1HWZRUNVHSDUDWLRQ
SCALANCE SCALANCE
X208 X208
PC/IPC with
CP 1616 as
IO Device
*B,.B;;B
352),1(7,QGXVWULDO(WKHUQHW
LI,57LVUHTXLUHGVZLWFKHVZLWK
,57IXQFWLRQDOLWLHV (76 (76
HJ6&$/$1&(;,57
PXVWEHXVHG
Industrial Ethernet 9
© Siemens AG 2010
T
INE
OF
PR
managed
X-400 1)
CP 343-1 CP 443-1
Advanced Advanced
Control Level
CP 1623
X-400
T
INE
OF
PR
managed
X-300 1)
T
INE
OF
PR
managed
CP 343-1 CP 443-1
X-200 1)
CP 343-1 Lean
XF-200 X-200 X-200PRO CP 343-1 BACnet
T
INE
OF
PR
X-200IRT 1)
managed
Field Level
T
INE
OF
PR
unmanaged
CSM 1277
X-100 X-100 Media converter
T
INE
OF
G_IK10_XX_10237
PR
unmanaged
X-000
X005 XB-000/XB-000G
Overview of SCALANCE X Industrial Ethernet switches and components with switch functionality
• Basis for integrated networking in industrial • Configuration of small networks • Communications processor for interfacing with
automation - from the field to the management PROFINET/Industrial Ethernet including
level integral switch for:
• Network components optimized for various • Easy expansion of the number of ports for: - For interfacing with distributed I/O.
applications: - Connection of local HMI systems - Connection to higher-level networks
- Small and large-scale networks - Connection to higher-level networks - IP routing
- Management functions for network - Service/maintenance - Service/maintenance
structuring
- Configuring of redundant networks
G_IK10_XX_10238
The CSM 1277 and CSM 377 Compact Switch Modules are
unmanaged switches for simple and rapid connection of a Properties at a glance
SIMATIC S7-1200, S7-300, or ET 200M to an electrical Indus-
trial Ethernet network. CSM 1277 unmanaged
The low-cost switches are thus suitable for the integration of
small machines into existing automation networks, for stand- ■ Saving on installation costs and installation space
alone operation of machines, or to set up small, local Ethernet compared to the use of an external network com-
networks. ponent
The single-width design allows space-saving installation on
the S7-1200 or S7-300 mounting rail. ■ Multiplication of the Ethernet interfaces on a SIMATIC
S7-1200 for additional connection of programming
devices, operator controls, and other Ethernet nodes
Industrial Ethernet
■ Cost-effective solution for the implementation of
SIMATIC S7-1200 SIMATIC S7-1200 SIMATIC S7-1200 small local Ethernet networks with a SIMATIC
with CSM 1277 with CSM 1277 with CSM 1277
S7-1200
Field PG
■ Uncrossed connecting cables can be used due to the
integrated Autocrossover function
(7SUR
6
ZLWK&3 (7SUR
(76 ■ Automatic detection and negotiation of the data
transmission rate by means of autosensing and
autonegotiation function
*B,.B;;B
352),1(7
,QGXVWULDO(WKHUQHW
6&$/$1&(
6 ;
6
&3
&3
*B,.B;;B
,3&ZLWK 3DQHO3&
&3$
&3
• SCALANCE XB005 with five electrical ports ■ Automatic detection and negotiation of the data trans-
• SCALANCE XB008 with eight electrical ports mission rate by means of autosensing and autonego-
• SCALANCE XB004-1/XB004-1LD with four electrical and tiation function
one optical port (SC)
1000 Mbit/s
PC Operator control
and process
monitoring
Image IP camera
scanner
G_IK10_XX_10259
Conveyor belt
SCALANCE
XB005 Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
*B,.B;;B
10/100 Mbit/s
X112-2 X104-2 X106-1
PROFINET
Industrial
Ethernet
G_IK10_XX_10261
Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)
Electrical and optical line topology with SCALANCE X-100 and Power-over-Ethernet
• SCALANCE X108/X108PoE with eight electrical ports ■ Integrated autocrossover function makes the use of
• SCALANCE X116 with 16 electrical ports uncrossed connection cables possible
• SCALANCE X124 with 24 electrical ports ■ Automatic detection and negotiation of the data
• SCALANCE X104-2 with four electrical and two transmission rate by means of autosensing and auto-
optical ports (BFOC) negotiation function
• SCALANCE X106-1 with six electrical and one optical port
■ Power supply of up to two Power-over-Ethernet-
(BFOC)
enabled terminals via four-core data line
• SCALANCE X112-2 with twelve electrical and two
(SCALANCE X108PoE only)
optical ports (BFOC)
SIMATIC environ-
Signaling contact
Ring redundancy
LED diagnostics
On-site display
Fast Ethernet
(SET button)
2 x 24 V DC
without RM
10 / 100 Mbit/s 100 Mbit/s 10 Mbit/s
ment
SCALANCE X101-1 1 1 • • • • • • •
SCALANCE X101-1LD 1 1 • • • • • • •
SCALANCE X101-1POF 1 1 • • • • • • •
G_IK10_XX_10137
SCALANCE X101-1AUI 1 1 • • • • • • •
SCALANCE X101-1FL 1 1 • • • • • • •
Function overview of Industrial Ethernet media converters
6
2SHUDWRU6WDWLRQ
6 6
3& 6&$/$1&(
; 6
6&$/$1&( 6&$/$1&(
; ;
6
,3&
6&$/$1&(;
3&
,3& 6
6 6
*B,.B;;B
,QGXVWULDO(WKHUQHW 7ZLVWHG3DLU
,QGXVWULDO(WKHUQHW )LEHU2SWLF 6
High speed redundancy in the ring with electrical and optical paths
The managed switches of the SCALANCE X-200 product range The SCALANCE X-200 switches are available in electrical and
are very well suited for the setup of line, star, and ring struc- electrical/optical versions:
tures (10/100 Mbit/s).
Redundant ring topologies can be established via the • SCALANCE X208 with eight electrical ports
SCALANCE X-200 switches. • SCALANCE X204-2/X204-2LD with four electrical and two
On the failure of a transmission link or a SCALANCE X-200 optical ports (BFOC)
switch in the ring, the transmission path is reconfigured • SCALANCE X206-1/X206-1LD with six electrical and one
within 200 ms. optical port (BFOC)
With the C-PLUG swap medium, devices can be exchanged • SCALANCE X212-2/X212-2LD with 12 electrical and two
without a programming device; the configuration or applica- optical ports (BFOC)
tion data are secured on the C-PLUG and can be implemented • SCALANCE X216 with 16 electrical ports
in another SCALANCE X-200 switch without special know- • SCALANCE X224 with 24 electrical ports
how.
Based on PROFINET, the switches of the SCALANCE X-200
product line can be easily integrated into the process and
system diagnostics.
The SCALANCE XF-200 switches have an extra-flat design. Thanks to its rugged design, the SCALANCE X-200PRO Industrial
These industry-standard units with IP20 degree of protection and Ethernet switch with IP65 degree of protection allows the setup of
special port arrangement with angled cable outlet allows easy a star network topology outside the control cabinet. If needed,
installation of the switches in the control cabinet or control box. the network can be powered by 24 V DC, or with 230 V AC using
In addition, they offer an integrated redundancy manager func- the PS791-1PRO power supply.
tion, which allows the network to be reestablished within milli-
seconds following an error. • SCALANCE X208PRO with eight electrical ports
(7SUR (7SUR
6PLW&3
+HDY\JDXJHWKUHDGHGMRLQW
2SHUDWRUFRQWURODQGPRQLWRULQJ
)LHOG3*
(76
3RZHU6XSSO\ 6&$/$1&(
,3&PLW 36352 ;352
&3
$FFHVV3RLQW
6&$/$1&(
$&9 :352
'&9
3RZHU6XSSO\ 0RELOH3DQHO
36352 '&9
*B,.B;;B
,:/$1
$&9
352),1(7
,QGXVWULDO(WKHUQHW
Configuration for cabinet-free setup with SCALANCE X208PRO with IP65 degree of protection
Control cabinet
PROFINET SCALANCE SIMATIC Microbox with
XF204IRT ET 200S CP 1604 as PN IO-Controller
Industrial
Ethernet
PC with CP 1616
as PN IO controller
PROFINET
Industrial Ethernet
Field PG
SCALANCE
SCALANCE X204IRT Control cabinet
X204IRT
SCALANCE
XF204IRT ET 200S TP 177B
G_IK10_XX_10100
G_IK10_XX_10256
IPC with CP 1616 ET 200S ET 200S
as PN IO device
Configuration example for SCALANCE X204IRT Use of SCALANCE XF-200/XF-200IRT in slim control boxes
With the versions SCALANCE X-200IRT, real time and iso- SCALANCE XF-200IRT managed
chronous real time networks can be set up. As a result, one
network is available for hard real-time and standard data Thanks to the advantages of its slim design, the SCALANCE
transmission (TCP/IP), preventing the need for a double XF-204IRT switch allows the setup of real-time and isochro-
infrastructure. nous real-time networks. As a result, one network is available
for hard real-time and standard data transmission (TCP/IP),
Redundant ring structures can be set up and two sub- preventing the need for a double infrastructure.
networks, e.g. rings, can be connected redundantly via the
SCALANCE X-200IRT switches (standby function). Redundant ring structures can be set up and two subnets, e.g.
rings, can be connected redundantly (standby function).
On the failure of a transmission link or a SCALANCE X-200
switch in the ring, the transmission path is reconfigured Fast Start-Up
within 200 ms.
In modern manufacturing applications, the installed robots
The SCALANCE X-200IRT switches are available as electrical use different tools depending on the task. For this, a fast
and electrical/optical versions with degrees of protection IP30 power-up of the components on the robot tools is necessary.
and IP65: The power-up behavior (link building, data forwarding) of
PROFINET network components and I/O devices has been
• SCALANCE X204IRT with four electrical ports optimized with the new Fast Start-Up (FSU) functionality.
• SCALANCE X201-3P IRT with one electrical port and three Depending on the peripheral devices used, the start-up can
optical ports (POF/PCF) occur within 500 ms after power is applied and the compo-
• SCALANCE X200-4P IRT with four optical ports (POF/PCF) nents are included in the data exchange.
• SCALANCE X202-2IRT/X202-2P IRT with two electrical and The demand for very short cycle times in production is met not
two optical ports (BFOC or POF/PCF) only by PROFINET IO controllers and I/O devices, but also by
• SCALANCE X204IRT PRO with four electrical ports SCALANCE X switches with integrated ERTEC and IRT func-
tionality.
2SHUDWRU6WDWLRQ 2SHUDWRU6WDWLRQV
6
6&$/$1&( 6&$/$1&(
;,57 ;
,QGXVWULDO(WKHUQHW
)LEHURSWLFFDEOH 0ELWV
6&$/$1&(;,57 6&$/$1&(;,57
DVVWDQGE\PDVWHU DVVWDQGE\VODYH
0ELWV
6&$/$1&( 6&$/$1&(
6 ; ;,57
,3&
*B,.B;;B
6
PC PC
S7-400 S7-400
G_IK10_XX_10215
ET 200S ET 200S PC ET 200S
The compact Gigabit switches of the SCALANCE X-300 product The following network topologies and combinations of topo-
range are Industrial Ethernet switches for setting up line, star, logies are possible:
and ring topologies (10/100/1000 Mbit/s) for high-perfor-
mance networks. They enable the construction of optical • Fast Ethernet and Gigabit Ethernet rings with fast media
and/or electrical networks with high network availability, redundancy. To protect against failure of a transmission link
since, for example, they enable ring redundancy in combina- or a switch, as many as 50 SCALANCE X-300 switches cas-
tion with a redundancy manager function and have a redun- caded in line can be connected into a ring. On the failure of
dant power supply. a transmission link or a SCALANCE X-300 switch in the ring,
the transmission path is reconfigured within 200 ms.
With the C-PLUG swap medium, devices can be exchanged • Redundant connection of the ring topology to the corpo-
without programming device; the configuration or applica- rate network using Rapid Spanning Tree Protocol (RSTP)
tion data are secured on the C-PLUG and can be implemented • Redundant linking of subnets, e.g. ring topologies
in another SCALANCE X-300 switch without special expertise. (standby redundancy)
• Star topology with SCALANCE X-300 switches:
The gigabit ports are typically used for connecting the Each SCALANCE X-300 switch represents a star point which
switches to each other and for a possible connection to can interconnect nodes or subnets electrically or optically.
higher network levels. • Problem-free connection of existing twisted-pair data termi-
nals or existing network segments at 10/100/1000 Mbit/s
• High availability of the network thanks to:
- Redundant power supply
- Redundant network structures based on fiber-optic or
twisted pair cables
Switches with Fast Ethernet and Gigabit Ethernet ports Fast Ethernet switches
SCALANCE X307-3
• Three optical Gigabit ports (SC multimode, up to 750 m)
• Seven Fast Ethernet ports
SCALANCE X307-3LD
• Three optical Gigabit ports (SC singlemode, up to 10 km)
• Seven Fast Ethernet ports
The main application areas for the SCALANCE XR-300 switches Space is also saved in the control cabinet due to the flexible
are high-performance plant networks with a connection to the cable outlet on the front or rear of the device.
enterprise network, as well as power distribution centers. Thanks
to the compact, space-saving 19" design, the SCALANCE XR-300 LEDs, connections for the power supply and data cable outlet
can be installed in 19" control cabinets. are installed − depending on the device variant − on the front
or rear.
SCALANCE XR-300 switches permit the configuration of
switched networks at the field level and control level, which The power supply is alternatively from
not only demand high availability of the network and exten-
sive diagnostic options, but also high transmission rates. • 1 x 24 V DC power supply unit
• 1 x 110 to 230 V AC power supply unit
The use of media modules supports unlimited flexibility in expan-
sion (e.g. more data terminals) or conversion of the network
(e.g. conversion from copper to fiber-optic conductors).
)RUYHUVLRQVFRQWDLQLQJFDEOHRXWOHWDWWKHUHDU
RQO\WKH/('ILHOGDQG6(/(&76(7EXWWRQVDV
ZHOODVWKHVHULDOFRQVROHSRUW 5- DUHDWWKH
IURQW
)URQW
5HDU
6ORWIRU
&3/8*
G_IK10_XX_10283
&RQQHFWLRQH[DPSOH &RQQHFWLRQH[DPSOH
,()&5-3OXJ)DVW&RQQHFWFRQQHFWRU )&%)2&3OXJ)DVW&RQQHFWFRQQHFWRU
WR00&8&PHGLDPRGXOH WR00PHGLDPRGXOH
ZLWKUHWDLQLQJFROODU PXOWLPRGH
Office
HiPath IP
Access Phone
Point
PoE PoE
SCALANCE
X308-2M PoE SCALANCE
XR324-4M PoE
(CFMC1315)
Engineering station
SCALANCE SCALANCE
XR324-4MEEC XR324-4MEEC
G_IK10_XX_10278
Properties at a glance
■ Simple adaptation to the structure of a plant thanks ■ Integrated configuration and diagnostics in STEP 7
to the modularity offered by 2-port media modules
■ Integrated redundancy manager for constructing
■ Diagnostics on the device by means of LEDs (power, Fast Ethernet and Gigabit Ethernet ring topologies
link status, data communication) and signaling con- with high-speed media redundancy
tact (signaling mask can be set on site using buttons)
■ Integration of the switches in existing network man-
■ Redundant power supply agement infrastructure by means of SNMP access
■ Reduction of the network installation costs due to ■ Automatic e-mail sending function
savings in power cables and additional network com-
ponents when Power-over-Ethernet is used ■ C-PLUG swap medium for rapid replacement of
devices
■ RJ45 sockets with a sleeve for additional strain relief,
designed for PROFINET-compliant IE FC RJ45 plug ■ Multicast and Broadcast limitation
■ Integrated autocrossover function makes the use of ■ Support of VLAN permits integration into Enterprise
uncrossed connection cables possible Security Policies
■ Automatic detection and negotiation of the data ■ IGMP Snooping and IGMP Query support Multicast fil-
transmission rate by means of autosensing and tering and limiting
autonegotiation function
■ Investment protection due to compatibility of
■ Remote diagnosis is performed by means of SNMP, SCALANCE X with OSM and ESM
Web browser and PROFINET IO diagnostics
2SWLFDO
SRUWPHGLDPRGXOHV
DUHLQVHUWHGLQWRWKH
GHYLFH
6)3PHGLDPRGXOHV
WZR6)3VORWV DUH
LQVHUWHGLQWRWKHGHYLFH
G_IK10_XX_10282
(OHFWULFDO 2SWLFDO
SRUWPHGLDPRGXOHV 6)3SOXJJDEOHWUDQVFHLYHUV
DUHLQVHUWHGLQWRWKH RQHSRUW DUHLQVHUWHGLQWR
GHYLFH WKH6)3PHGLDPRGXOH
Properties at a glance
The modular switches of the SCALANCE X-400 product range The following network topologies and combinations of
are Industrial Ethernet switches for setting up line, star, and topologies are possible:
ring structures (10/100/1000 Mbit/s) for high-performance
networks. • Fast Ethernet and Gigabit Ethernet rings with fast media
They allow flexible setup of optical or electrical networks, redundancy. To protect against failure of a transmission link
which can be adapted in their topology, port number, and port or a switch, as many as 50 X-400 switches cascaded in line
type to the respective network structures. They allow high can be connected into a ring. On the failure of a transmis-
network availability, since, for example, they enable ring redun- sion link or a SCALANCE X-400 switch in the ring, the trans-
dancy in combination with a redundancy manager function, mission path is reconfigured within 200 ms.
have redundant power supply or permit exchange and exten- • Redundant connection of the ring topology to the corpo-
sion of media modules during operation. rate network using Rapid Spanning Tree Protocol (RSTP).
• Redundant linking of subnets, e.g. ring topologies
With the C-PLUG swap medium, devices can be exchanged (standby redundancy)
without programming device; the configuration or application • Star topology with SCALANCE X-400 switches:
data are secured on the C-PLUG and can be implemented in Each SCALANCE X-400 switch represents a star point which
another SCALANCE X-400 switch without special know-how. can interconnect up to 26 nodes or subnets electrically or
optically.
• SCALANCE X-400 switches have a modular structure, in • Problem-free connection of existing twisted-pair data
which media modules and/or extender modules can be terminals or existing network segments up to
connected to the switch as required. Thanks to these 10/100/1000 Mbit/s
expansions, up to eight electrical and eight optical ports • High availability of the network thanks to:
are additionally available. - Redundant power supply
The gigabit ports are typically used for connecting the - Redundant network structures based on fiber-optic or
switches to each other and for a possible connection to twisted pair cables
higher network levels. Optical connections are available by - Replacement and extension of media and expansion
means of media modules. modules during operation
The SCALANCE X-400 switches are well suited, for exam- - Layer-3 functionality and Virtual Router Redundancy
ple, to process control systems such as PCS7. Protocol (VRRP) enable use as routers between different
IP subnets, also redundantly (only SCALANCE X414-3E)
6&$/$1&(
;
266HUYHU 266HUYHU
UHGXQGDQW 0ELWV UHGXQGDQW
,QGXVWULDO(WKHUQHW
HOHFWULFDO
5HGXQGDQWFRQWURO 6
6+
*B,.B;;B
(70 (70
Use of the SCALANCE X-400 switches in a process control system, e.g. PCS 7
Properties at a glance
■ Diagnostics on the device by means of LEDs (power, ■ Integrated configuration and diagnostics in STEP 7
link status, data communication) and signaling con-
tact (signaling mask can be set on site using buttons) ■ Integration of the switches in existing network man-
agement infrastructure by means of SNMP access
■ Redundant power supply
■ Automatic e-mail sending function
■ RJ45 sockets with a sleeve for additional strain relief,
designed for PROFINET-compliant IE FC RJ45 plug con- ■ C-PLUG swap medium for rapid replacement of devices
nector
■ Multicast and Broadcast limitation
■ Flexible, modular design
■ Support of VLAN permits integration into Enterprise
■ Integrated autocrossover function makes the use of Security Policies
uncrossed connection cables possible
■ IGMP Snooping and IGMP Query support Multicast
■ Automatic detection and negotiation of the data trans- filtering and limiting
mission rate by means of autosensing and autonego-
tiation function ■ Investment protection due to compatibility of
SCALANCE X with OSM and ESM
■ Remote diagnosis is performed by means of SNMP,
web browser and PROFINET IO diagnostics ■ Layer 3 functionality (IP Routing; SCALANCE X414-3E)
(76
• Establishment of small networks without additional switch
• Connection of machines or process cells to higher-level 6,0$7,&6
ZLWK&3
networks
• Network separation by means of Layer 3 functionality
(IP routing) with CP 343-1 Advanced and
*B,.B;;B
CP 443-1 Advanced. )LHOG3*
352),1(7
• Functions for network diagnostics
,QGXVWULDO(WKHUQHW
352),1(7
SCALANCE
X208
Field PG SCALANCE SCALANCE SCALANCE
X208 X208 X208
PC/IPC
with
CP 1616
as IO
Device SCALANCE
XF208
G_IK10_XX_10249
■ Connection to SIMATIC S7 via backplane bus ■ Connection in the PC via PCI, PCIe or PC/104-Plus
interface
■ Diagnostics on the device by means of LEDs
(link status, bus fault, data communication) ■ Redundant voltage supply via PCIe interface and
external power supply 12 to 24 V DC for operating
■ RJ45 sockets with a sleeve for additional strain relief, the switch when the PC is turned off (CP 1623 only)
designed for PROFINET-compliant IE FC RJ45 plug
■ Integrated autocrossover function makes the use of
■ Integrated autocrossover function makes the use of uncrossed connection cables possible
uncrossed connection cables possible
■ Automatic detection and negotiation of the data
■ Automatic detection and negotiation of the data transmission rate by means of autosensing and auto-
transmission rate by means of autosensing and auto- negotiation function
negotiation function
■ Remote diagnostics is performed by means of SNMP
■ Remote diagnostics is performed by means of SNMP, and PROFINET IO diagnostics
Web browser and PROFINET IO diagnostics
■ Support of PROFINET IRT for time-critical applications
■ Support of PROFINET IRT for time-critical applications, also with isochronous closed-loop control in the
also with isochronous closed-loop control in the motion motion control area (except CP 1623)
control area (except CP 343-1 Lean/CP 343-1)
■ Integrated configuration and diagnostics in STEP 7
■ Integrated configuration and diagnostics in STEP 7
■ Integration of the CPs into existing network manage-
■ Integration of the CPs into existing network manage- ment infrastructure by means of SNMP access
ment infrastructure by means of SNMP access
■ Support for Gigabit Ethernet (CP 1623 only)
■ Automatic e-mail sending function (Advanced CPs only)
G_IK10_XX_10288
X206-1/XF206-1 6x RJ45 1x BFOC
X206-1LD 6x RJ45 1x BFOC
X204-2/XF204-2 4x RJ45 2x BFOC
X204-2LD 4x RJ45 2x BFOC
1) The specified number of ports pertains to the max. possible number of devices per interface type.
The combined number of ports per device is provided in the specific technical data.
Elektrisch
Electrical Optisch
Optical Elektrisch
Electrical Optisch
Optical
Modultyp
Type of module Twisted Pair Multimode Singlemode Twisted Pair POF/PCF Multimode Singlemode
X124 24x RJ45
X116 16x RJ45
X112-2 12x RJ45 2x BFOC SCALANCE
X108/X108PoE 8x RJ45 X-100
X106-1 6x RJ45 1x BFOC
X104-2 4x RJ45 2x BFOC
X005/XB005 5x RJ45
XB008 8x RJ45
XB004-1 4x RJ45 1x SC
XB004-1LD 4x RJ45 1x SC SCALANCE
G_IK10_XX_10289
XB005G 5x RJ45 X-000
XB008G 8x RJ45
XB004-1G 4x RJ45 1x SC
XB004-1LDG 4x RJ45 1x SC
Network management
The network management products SINEMA Server (SIMATIC Furthermore, the software offers an e-mail client function and
Network Manager) and SNMP/OPC Server support in monitor- OPC server in order to forward network data and alarms to
ing and diagnosing wireless and wired networks in industrial other systems. SINEMA Server can be easily integrated in HMI
environments. and visualization systems such as SIMATIC WinCC.
SINEMA Server network management Changes in the network, such as the addition of new devices,
are reported to the user through the alarm console and saved
SINEMA Server network management software diagnoses and in a database. For the analysis of past network failures or as
visualizes Ethernet networks. It continuously logs network evidence of network availability, the database information can
activities using various protocols such as SNMP, DCP, and LLDP, be prepared and documented as reports for a configurable
makes them available to users and other systems on the net- period of time. The SINEMA user interface and the available
work, e.g. HMI software such as WinCC, for evaluation and features are accessible via the browser from any computers on
further processing. the network.
IGMP-Snooping/-Querier
PROFINET diagnostics
Fault signaling contact
Layer 3 (IP-Routing)
Message screen
RSTP
VLAN
LED
Module type
SCALANCE X-400
• • • • • • • • • • • 1)
SCALANCE X-300
• • • • • • • • • •
SCALANCE X-200
• • • • • •
SCALANCE X-100
• • •
SCALANCE X-000
•
OSM
• • • • •
ESM
• • • • •
CSM
•
CP for S7-300
• • • 2)
•
CP for S7-400
• • • 2)
•
G_IK10_XX_10138
CP 1604
• • • 2)
•
CP 1616
• • • 2)
•
CP 1623
• •
1) only SCALANCE X414-3E
2) Port diagnostics possible via integral web server
Industrial Ethernet switches and components with switch functionality: Network structure diagnostic options and logs
Industrial Ethernet
Networking with FastConnect
Industrial Ethernet 37
© Siemens AG 2010
Industrial Ethernet
Networking with FastConnect
38 Industrial Ethernet
© Siemens AG 2010
■ Rugged industry-compatible design ■ One network for strict real time and standard TCP/IP,
saving on duplicated infrastructure
■ The right construction type for any application
■ Reduction of downtimes due to saving of engi-
■ Protection of investments: Existing networks can be neering and configuration data
expanded with new products
■ Quick, easy and reliable cabling and the option of
■ Integration into existing concepts for network secu- self-assembly
rity thanks to integral security functions
■ On-site or remote parameterization and diagnostics
■ Broad-based use in small or large networks even out-
side the control cabinet ■ Support from SIMATIC Engineering Tools
■ Avoidance of additional training and familiarization ■ Embedding in the SIMATIC error message concept
costs thanks to the use of standardized (system fault signaling, SFM) and PROFINET
Ethernet technology
■ Networking without the need for additional
■ High network and machine availability gateways