Datasheet CMT Sewage Water Test Kit

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

2.

Marine Sewage Water Test Kits


MARPOL Annex IV contains a set of ISPPC (International Sewage Pollution
Ordering Information
regulations regarding the discharge Prevention Certificate) are issued upon
of sewage into the sea from ships, successful inspection and are valid for 5
WTK-CT-80041
including regulations regarding the years.
Sewage Effluent Test Kit 1
ships’ equipment and systems for
For renewal and random inspections, Complies with MEPC 2(VI)
the control of sewage discharge, the

Water Condition Monitoring


maintaining the system operating Commission before 2010
provision of port reception facilities
requirements in line with the effluent Coliform Bact. (12): 0 – 2424 CFU/100ml
for sewage, and requirements for
standards will be required. With this in TSS (unlimited): 5 – 500 mg/l
survey and certification (ISPPC –
mind, the CMT Marine Sewage Effluent BOD (unlimited): 7.5 – 255 mg/l O2
International Sewage Pollution
Test Kit will provide simple and accurate Thermometer: -50 to 150°C
Prevention Certificate).
testing. Digital Incubator 25 - 45°C
The discharge of raw sewage into the
Requirements from MARPOL Annex IV
sea can create a health hazard, while in WTK-CT-80042
Resolution MEPC.159(55) – Effluent &
coastal areas sewage can also lead to Sewage Effluent Test Kit 2
Performance Standards are defined as
oxygen depletion and an obvious visual Complies with MEPC 159(55)
follows:
pollution. Commission 2010 and later
• BOD up to 25 ppm Additionally to WTK-CT-80041:
Environmental issues are still a hot topic
COD Test (25): 0 – 300 mg/l
these days. The shipping community • COD up to 125 ppm
pH Test Strips (50): 4 – 10 pH
expresses its concern about the
• Total Suspended Solids max. 35 ppm Free Chlorine (100): 0 – 1.0 ppm
ecosystem and the pollution of the
Free Chlorine (100): 0 – 30 ppm
seas. In this market where low freight • Coliforms up to 100 CFU / 100 ml
rates, new rules and regulations and a
• pH 6.0 – 8.5 WTK-CT-80043
higher customer demand are pressuring
Sewage Effluent Test Kit 3
our business-results, we still desire to • Chlorine (Free) up to 0.5 ppm
Complies with MEPC 159(55) & 227(64)
comply with new rules and regulations
Nowadays tests in the market are All Passenger Ships
but preferably in a cost-effective and
complicated and comprehensively. The Additionally to WTK-CT-80041:
efficient way
Chief-Engineers almost need to have a COD Test (25): 0 – 1500 ppm
To test the discharge of Sewage chemist-degree in order to understand pH Test Strips (50): 5 – 11 pH
treatment plants CMT offers a quick and execute the time consuming tests. Free Chlorine (100): 0 – 1.0 ppm
and easy drop test for testing the free The CMT Sewage Effluent Test Kits are Free Chlorine (100): 0 – 30 ppm
chlorine content. simple and very user-friendly. Total Nitrogen (25): 0.5 - 25 ppm
Total Phosphorus(25): 2 - 2.6 ppm
The Budget Sewage Effluent Kit
provides an indication for the key
WTK-CT-80044
parameters set out in MARPOL Annex
Budget Sewage Effluent Test Kit
IV. The coliform dip slides provided will
Dip Slides (10) 0 - 100,000 CFU / ml
require an incubator to ensure accuracy,
TSS (unlimited): 5 – 500 mg/l
which can be purchased separately.
BOD (unlimited): 7.5 – 255 mg/l O2
For complete accuracy you will need to
COD (100): 0 - 300 mg/l
purchase the standard range of sewage
pH Test Strips (50): 5 – 11 pH
effluent kits. These come complete with
Free Chlorine (100): 0 – 1.0 ppm
a coliform plate method and incubator.
Free Chlorine (100): 0 – 30 ppm
The coliform plate method provides a
Thermometer: -50 to 150°C
MPN count, which will provide more
accuracy than the coliform dip slides.
Reagents (Full refill of respective Test Kit)
Regular testing will allow rapid corrective
action to take place if required, helping WTK-CT-85041
to maintain optimum operating Sewage Effluent Consumables Pack 1
conditions, minimum downtime and
WTK-CT-85042
As set out in Annex 22 Resolution reducing costs. Ultimately the CMT
Sewage Effluent Consumables Pack 2
MEPC.227(64) adopted on the 5th Marine Effluent Cabinet will aid
October 2012, sewage treatment plants compliance with MARPOL Annex IV. WTK-CT-85043
installed prior to 1st January 2010, Sewage Effluent Consumables Pack 3
The CMT Marine Water Test
on ships other than passenger ships
Solutions comply with: WTK-CT-85044
operating in MARPOL Annex IV special
areas and intending to discharge treated • MARPOL Annex IV: Resolution Sewage Effluent Consumables Pack
effluent into the sea, should comply with - MEPC.2 (IV) Budget
resolution MEPC.2(VI) adopted on 3rd - MEPC.115 (51)
December 1976. - MEPC.159 (55)