Digital Power Monitoring

1
®

Digital Power Monitoring

HFPM-96F/I
DIGITAL POWER MONITORING FOR SINGLE AND THREE PHASE SYSTEM
• Measures kWh, kVARh, kW, kVAR, kVA, P, F, PF, Hz, Dmd, V, A, etc.
• Bi-directional measurement IMP & EXP
• Energy information of each phase
• Total harmonic distortion of voltage and current
• 2nd~63rd Individual harmonic distortion
• RS485 Modbus RTU & two pulse outputs
• Bar graph for power indication
• Three phase self-power supply
• Backlit LCD display for full viewing angles
• High accuration class
• Plug-in Play solution
• Real time clock
Features HFPM-96F HFPM-96I
• Dimension: 96x96mm
Network
• Via CT..../1A or ..../5A Single phase 2 wire √ √
Two phase 3 wire √ √
Features HFPM-96F HFPM-96I
Three phase 3 wire √ √
Measurements
Three phase 4 wire √ √
Instantaneous Value
CT programmable √ √
Current I1, I2, I3, In √ √
PT programmable √ √
Voltage L-N V1, V2, V3 √ √
Inputs and Ouputs
L-L V1-2, V2-3, V3-1 √ √
Digital Inputs DI 4
Frequency Hz √ √
Digital Outputs DO 2
Active power P∑, P1, P2, P3 √ √
Analog Outputs AO
Reactive power Q∑, Q1,Q2, Q3 √ √
Pulse Outputs S0
Apparent power S∑,S1, S2, S3 √ √
Alarms 30
PF∑, PF1, PF2,
Power factor √ √ Communications
PF3
Energy Values RS485 Modbus RTU √ √
kWh∑, kWh1, Ethernet TCP/IP √
Active energy √ √
kWh2, kWh3 Ethernet Gateway TCP/IP
kVARh∑, kVARh1, Accuracy Class Class
Reactive energy √ √
kVARh2, kVARh3 Active energy 0.5s 0.5s
kVAh∑, kWAh1, Reactive energy 1 1
Apparent energy √ √
kVAh2, kVAh3
Current 0.2 0.2
Demand Values
Voltage 0.5 0.2
Current √ √
Power 0.5 0.2
Active, reactive, apparent
√ √ THD and IHD 2 2
power
Hz 0.2 0.2
Maximum Demand Values
Number of measurement
Maximum current √ √ 128 256
points per circle
Maximum active power √ √
Power supply
Maximum reactive power √ √
65~480VAC /
Maximum apparent power √ √ Auxiliary power supply √ √
80~660VDC
Min. and Max. Value 24~48VDC * *
Active power per phase and Self-power supply 100~480VAC
√ √
total
DPF Displacement Power
Reactive power per phase √
√ √ Factor)
and total
Voltage crest factor √
Apparent power per phase
√ √ Current K factor √
and total
Voltage unbalance √
PF per phase and total √ √
Current per phase and
√ √
average Dimension
3

THDi per phase √ √


THDv L-L and L-N √ √
Power-Quality Values
Total harmonic distortion THDv and THDi √ √
96

62

98

Individual Harmonic distortion IHDv and IHDi 63th 63th


Multi Tariffs 4 4
Running Hour √ √
Real Time Clock √ √

(*) By request 12.7


18
25
60.8
1
®

Single Phase Energy Meter


HFEM-1132DP
SINGLE PHASE ENERGY METER
• Active energy measured
• LCD display with backlit
• Pulse output
• 32A direct connection
• Class 1.0 accuracy
• Din rail mounted
• 1 Module, 17.5mm width

Performance criteria Specification


Operating humidity ≤ 90% Display LCD with Backlit
Storage humidity ≤ 95% Nominal voltage(Un) 230VAC
Operating temperature -25°C - +55°C Operational voltage 80%~120% of Un
Storage temperature -40°C - +70°C Insulation capabilities
Reference temperature 23°C± 2°C - AC voltage withstand 4kV for 1 minute
International standard IEC 62053-21 / EN50470-1/3 - Impulse voltage withstand 6kV-1.2μS
Accuracy class Class1 / Class B Basic current (Ib) 5A
Installation category CAT II Maximum rated current (Imax) 32A
Mechanical environment M1 Mini current (Imin) 0.25A
Electromagnetic environment E2 Operational current range 0.4% Ib-Imax
Degree of pollution 2 Over current withstand 30 Imax for 0.01s
Protection against penetration of dust Operational frequency range 50 / 60Hz
IP51(indoor)
and water Internal power consumption ≤ 2W/10VA
Insulating encased meter of protective Pulse output 1000imp/kWh
II
class
Max reading 99999.9 kWh
Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV
Surge 4kV
Radiated & conducted
EN 55022
emissions

Dimension Wiring Diagram

17
5m
m
62 mm

35m m

2
®

Single Phase Energy Meter


HFEM-1132DCOM
SINGLE PHASE ENERGY METER
• Multi-measurement : kWh,kVARh, kW, kVAR, kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• Bi-directional measurement IMP & EXP
• 32A direct connection
• RS485 Modbus
• 2 Pulse outputs
• 1 Module, 17.5mm width

Specification Accuracy
Nominal voltage(Un) 230VAC Voltage,Current 0.5
Operational voltage 80%~120% of Un Frequency 0.2 of mid-frequency
Insulation capabilities Power factor 1 of unity (0.01)
- AC voltage withstand 4kV for 1 minute Active power, Apparent power 1 of range maximum
- Impulse voltage withstand 6kV-1.2μS Reactive power 1 of range maximum
Basic current (Ib) 5A Reactive energy (VARh) Class 2
Maximum rated current (Imax) 32A Active energy (Wh) Class 1
Mini currrent (Imin) 0.25A Modbus
Operational current range 0.4% Ib-Imax Bus type RS485(semi-duplex)
Over current withstand 30 Imax for 0.01s Protocol Modbus RTU
Operational frequency range 50 or 60Hz 1200/2400/4800/9600/19.200
Baud rate
Internal power consumption <2W/10VA (Optional)
Pulse output 1 Configurable Address range 1-247
Pulse output 2 1000imp/kWh (default) Max. Bus loading 64pcs
Max reading 99999.9kWh Communication distance 1000M
Display LCD with blue backlit Pulse output
Performance criteria Pulse outputs 2
Operating humidity ≤ 90% Pulse output type Passive
Storage humidity ≤ 95% Pulse Output 1 Configurable
Operating temperature -25°C - +55°C Pulse width 200/100(default)/60ms
Storage temperature -40°C - +70°C Pulse output 2 1000imp/kWh
Reference temperature 23°C ± 2°C
International standard IEC 62053-21 / EN50470-1/3
Accuracy class Class 1/Class B
Installation category CAT II
Mechanical environment M1
Electromagnetic environment E2
Degree of pollution 2
Protection against penetration
IP51(indoor)
of dust and water
Insulating encased meter of
II
protective class

Dimension Wiring Diagram


17
5m
m

G B A
62 mm

35m m

3
®

Single Phase Energy Meter


HFEM-1263MDP
ANALOG SINGLE PHASE ENERGY METER
• Measure total energy
• Analog display
• Pulse output
• 63A direct connection
• Class 1.0 accuracy
• Din rail mounted
• 2 Modules, 36mm width

General Specifications Environment


Voltage AC (Un) 230V Operating temperature -25°C to + 55°C
Voltage Range 80%~120% of Un Storage and transportation tempera-
-40°C to + 70°C
Base Current (Ib) 10A ture
Max. Current (Imax) 63A Reference temperature 23°C ± 2°C
Mini Current (Imin) 0.5A Relative humidity 0 to 95%, non-condensing
Starting current 0.4% of Ib Altitude up to 2500m
Power consumption <2W/10VA Warm up time 10s
Frequency 50/60Hz(±10%) Mechanical Environment M1
AC voltage withstand 4kV for 1 minute Electromagnetic environment E2
Impulse voltage withstand 6kV-1.2uS wave form Degree of pollution 2
Overcurrent withstand 30Imax for 0.01s Mechanics
Pulse output rate 1000imp/kWh (default) Din rail dimensions 36x99x63 (WxHxD) DIN 43880
Display Analog Mounting DIN rail 35mm
Electromechanical register Sealing IP51 (indoor)
Max. Reading 99999.9kWh Material Self-extinguishing UL94V-0
Active energy Class 1 IEC62053-21
Class B EN50470-3

Dimension Wiring Diagram

4
®

Single Phase Energy Meter


HFEM-1263DDP
SINGLE PHASE MULTI-FUNCTION ENERGY METER
• Multi-measurement: kWh, kVarh, kW, kVAR, kVA, PF, Hz, dmd, V, A, etc.
• LCD display with backlit
• Bi-directional measurement IMP & EXP
• 63A direct load
• 2 Pulse outputs
• 2 Module 36mm width

Specifications Performance criteria


Nominal voltage(Un) 230VAC Operating humidity ≤ 90%
Operational voltage 80%~120% of Un Storage humidity ≤ 95%
Insulation capabilities Operating temperature -25°C - +55°C
AC voltage withstand 4kV for 1 minute Storage temperature -40°C - +70°C
Impulse voltage withstand 6kV-1.2μS Reference temperature 23°C± 2°C
Basic current (Ib) 10A IEC 62053-21 / IEC620532-22 /
International standard
Maximum rated current (Imax) 63A EN50470-1/3

Mini current (Imin) 0.5A Accuracy class Class 1

Operational current range 0.4% Ib-Imax Installation category CAT II

Over current withstand 30 Imax for 0.01s Mechanical environment M1

Operational frequency range 50/60Hz Electromagnetic


E2
environment
Internal power consumption ≤ 2W/10VA
Degree of pollution 2
Pulse output 1 1000imp/kWh
Protection against penetration of dust
Pulse output 2 1000imp/kWh IP51(indoor)
and water
Max reading 999999.9 kWh/kVarh Insulating encased meter of protective
II
Pulse Output class
Pulse outputs 2 Electrostatic discharges 8kV contact / 15kV air gap
Pulse output type Passive Electromagnetic HF fields IEC 61000-4-3
Pulse Output 1 Configurable Electrical fast transients 4kV
Pulse width 200/100(default)/60ms Surge 4kV
Pulse output 2 1000imp/kWh Radiated & conducted emissions EN 55022
Accuracy
Voltage,Current 0·5%
Frequency 0·2% of mid-frequency
Power factor 1% of unity (0.01)
Active power ,
±1% of range maximum
Apparent power
Reactive power ±1% of range maximum
Reactive energy(Varh) Class 2
Active energy (Wh) Class 1

Dimension Wiring Diagram

L in L out
4 5 mm

1 2
15 16
63 mm

1 2

+ - +
5 6 7 8 9 10
PULSE OUTPUT
36
m
m 35mm
99 mm
5 6 7 8 9 10
3 4
N in N out

5
®

Single Phase Energy Meter


HFEM-1263DCOM-MT
SINGLE PHASE MULTI-FUNCTION ENERGY METER
• Multi-measurement : kWh,kVARh, kW, kVAR, kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• Bi-directional measurement IMP & EXP
• 63A direct connection
• RS485 Modbus
• 2 Pulse outputs
• Multi tariffs
• 2 Modules, 36mm width

Specification Multi-tariff
Nominal voltage(Un) 230VAC time clock accuracy ﹤1s/day
Operational voltage 80%~120% of Un Tariff 4
Insulation capabilities Time segments 10
- AC voltage withstand 4kV for 1 minute Accuracy
- Impulse voltage withstand 6kV-1.2μS Voltage,Current 0.5%
Basic current (Ib) 5A Frequency 0.2% of mid-frequency
Maximum rated current (Imax) 63A Power factor 1% of unity (0.01)
Mini current (Imin) 0.25A Active power , Apparent power ±1% of range maximum
Operational current range 0.4% Ib-Imax Reactive power ±1% of range maximum
Over current withstand 30 Imax for 0.01s Reactive energy(Varh) Class 2
Operational frequency range 50/60Hz Active energy (Wh) Class 1
Internal power consumption ≤ 2W/10VA Modbus
Pulse output 1 Configurable Bus type RS485(semi-duplex)
Pulse output 2 1000imp/kWh Protocol Modbus RTU
Max reading 99999.99 kWh/kVarh 1200/2400/4800/9600bps/19200
Baud rate
(optional)
Performance criteria
Address range 1-247
Operating humidity ≤ 90%
Max. Bus loading 64pcs
Storage humidity ≤ 95%
Communication distance 1000M
Operating temperature -25°C - +55°C Parity EVEN/ODD/NONE
Storage temperature -40°C - +70°C Data bit 8
Reference temperature 23°C± 2°C Stop bit 1
International standard IEC 62053-21 / EN50470-1/3 Pulse Output
Accuracy class Class1/Class B Pulse outputs 2
Installation category CAT II Pulse output type Passive
Mechanical environment M1 Pulse Output 1 Configurable
Electromagnetic environment E2 Pulse width 200/100(default)/60ms
Degree of pollution 2 Pulse output 2 1000imp/kWh
Protection against penetration
IP51(indoor)
of dust and water
Insulating encased meter of
II
protective class

Dimension Wiring Diagram

GND B A
2 1

m
45m 4 5 6 7 8 9
PULSE OUTPUT RS485 PORT

5 6 7 8 9 10
47mm
62m m

mm 1 2 3
35
m
9 0m
m
m
36

L IN L OUT
N
6
®

Three Phase Energy Meter

HFEM-3480DCOM-MT
THREE PHASE ENERGY METER
• Multi-measurement : kWh, kVARh, kW, kVAR, kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• BI-directional measurement IMP & EXP
• 80A direct connection
• RS485 Modbus
• Real time clock
• Multi tariffs
• 2 Pulse outputs
• 4 Modules, 72mm width

Specification Multi-tariff
Nominal voltage(Un) 3x230/400VAC time clock accuracy ﹤1s/day
Operational voltage 80%~120% of Un Tariff 4
Insulation capabilities Time segments 10
- AC voltage withstand 4kV for 1 minute Accuracy
- Impulse voltage withstand 6kV-1.2μS Voltage,Current 0.5%
Basic current (Ib) 10A Frequency 0.2% of mid-frequency
Maximum rated current (Imax) 80A Power factor 1% of unity (0.01)
Operational current range 0.4% Ib-Imax Active power , Apparent power ±1% of range maximum
Over current withstand 30 Imax for 0.01s Reactive power ±1% of range maximum
Operational frequency range 50/60Hz Reactive energy(Varh) Class 2
Power consumption per phase ≤ 2W/10VA Active energy (Wh) Class 1
Display LCD Modbus
Max reading 999999.99 kWh/kVarh Bus type RS485(semi-duplex)
Performance criteria Protocol Modbus RTU
Operating humidity ≤ 90% Baud rate 2400/4800/9600/19200/38400bps
Storage humidity ≤ 95% Address range 1-247
Operating temperature -25°C - +55°C Max. Bus loading 64pcs
Storage temperature -40°C - +70°C Communication distance 1000M
Reference temperature 23°C± 2°C Parity EVEN/ODD/NONE
IEC 62053-21 / IEC 62053-22 / Data bit 8
International standard
EN50470-1/3 Stop bit 1
Accuracy class Class 1/Class 0.5S/Class B Pulse Output
Installation category CAT III Pulse outputs 2
Mechanical environment M1 Pulse output type Passive
Electromagnetic environment E2 Pulse Output 1 Configurable
Degree of pollution 2 Pulse width 200/100(default)/60ms
Protection against penetration of dust Pulse output 2 400imp/kWh
IP51(indoor)
and water
Insulating encased meter of protective
II
class
Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV

Dimension Wiring Diagram


Three Phase Four Wire Single Phase Two Wire Three Phase Three Wire

m L1 L2 L3 N L1 N L1 L3 L2
45 m

1 2 3 4 1 2 3 4 1 2 3 4

3p4w 1p2w 3p3w


66mm

5 6 7 8 5 6 7 8 5 6 7 8
m
72 35m
m mm
m
100

L1 L2 L3 N L1 N L1 L3 L2

7
®

Three Phase Energy Meter


HFEM-3400CTCOM-MT
THREE PHASE ENERGY METER
• Multi-measurement : kWh, kVARh, kW, kVAR, kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• BI-directional measurement IMP & EXP
• 5A CT operated
• RS485 Modbus
• Real time clock
• Multi tariffs
• 2 Pulse outputs
• 4 Modules, 72mm width

Specification Accuracy
Nominal voltage(Un) 3x230/400VAC Voltage,Current 0.5%
Operational voltage 60%~120% of Un Frequency 0.2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
- AC voltage withstand 4kV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6kV-1.2μS Reactive power ±1% of range maximum
Rated current (Ib) 5A CT or 333mV CT input/100mA Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 0.5S
Over current withstand 20 Imax for 0.01s Modbus
Operational frequency range 50/60Hz Bus type RS485(semi-duplex)
Power consumption per phase ≤ 2W/10VA Protocol Modbus RTU
Pulse output 1 Configurable Baud rate 2400/4800/9600/19200/38400bps
Pulse output 2 3200 imp/kWh Address range 1-247
Display LCD Max. Bus loading 64pcs
Max reading 9999999.9 kWh/kVarh Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
Reference temperature 23°C± 2°C
IEC 62053-21/IEC 62053-22/
International standard
EN50470-1/3
Accuracy class Class 1/Class 0.5S/Class B
Installation category CAT III
Mechanical environment M1
Electromagnetic environment E2
Degree of pollution 2
Protection against penetration of dust
IP51(indoor)
and water
Insulating encased meter of protective
II
class
Electrostatic discharges 8kV contact / 15kV air gap
Radiated & conducted emissions EN 55022

Dimension Wiring Diagram


Three Phase Four Wire Three Phase Three Wire Single Phase Two Wire
P1
S1
L1 P1
S1
L1 P1
S1
L
LOAD P1
S1 L2 LOAD L2 LOAD N
P1
S1 L3 P1
S1 L3
1 2 GND B A 1 2 GND B A 1 2 GND B A

S0 RS485 Current Inputs S0 RS485 Current Inputs S0 RS485 Current Inputs

9 10 11 12 13 14 15 16 17 18 19 20 9 10 11 12 13 14 15 16 17 18 19 20 9 10 11 12 13 14 15 16 17 18 19 20

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

Voltage Input L N L N Voltage Input L N L N Voltage Input L N L N

1A FAST 1A FAST 1A FAST 1A FAST 1A FAST 1A FAST


BLOW FUSE BLOW FUSE BLOW FUSE BLOW FUSE BLOW FUSE BLOW FUSE
AUX AUX AUX
L1 L1 L1
L2
LOAD L2 LOAD L2 LOAD
L3 L3
N
8
®

Three Phase Energy Meter


HFEM-3780DCOM-MT
THREE PHASE ENERGY METER
• Multi-measurement : kWh, kVARh, kW, kVAR,kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• BI-directional measurement IMP & EXP
• 80A direct connection
• RS485 Modbus
• Real time clock
• Multi tariffs
• 2 Pulse outputs
• 7 Modules, 125mm width

Specification Multi-tariff
Nominal voltage(Un) 3x230/400VAC time clock accuracy ﹤1s/day
Operational voltage 80%~120% of Un Tariff 4
Insulation capabilities Time segments 10
- AC voltage withstand 4kV for 1 minute Accuracy
- Impulse voltage withstand 6kV-1.2μS Voltage,Current 0.5%
Basic current (Ib) 10A Frequency 0.2% of mid-frequency
Maximum rated current (Imax) 80A Power factor 1% of unity (0.01)
Operational current range 0.4% Ib-Imax Active power , Apparent power ±1% of range maximum
Over current withstand 30 Imax for 0.01s Reactive power ±1% of range maximum
Operational frequency range 50/60Hz Reactive energy(Varh) Class 2
Power consumption per phase ≤ 2W/10VA Active energy (Wh) Class 1
Display LCD Modbus
Max reading 999999.99 kWh/kVarh Bus type RS485(semi-duplex)
Performance criteria Protocol Modbus RTU
Operating humidity ≤ 90% Baud rate 1200/2400/4800/9600bps
Storage humidity ≤ 95% Address range 1-247
Operating temperature -25°C - +55°C Max. Bus loading 64pcs
Storage temperature -40°C - +70°C Communication distance 1000M
Reference temperature 23°C± 2°C Parity EVEN/ODD/NONE
International standard IEC 62053-21 / EN50470-3 Data bit 8
Accuracy class Class 1 Stop bit 1
Installation category CAT III Pulse Output
Mechanical environment M1 Pulse outputs 2
Electromagnetic environment E2 Pulse output type Passive
Degree of pollution 2 Pulse Output 1 Configurable
Protection against penetration of Pulse width 200/100(default)/60ms
IP51(indoor)
dust and water Pulse output 2 400imp/kWh
Insulating encased meter of
II
protective class
Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV

Dimension Wiring Diagram

12 21 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8

24 23 22 21 20 19
65m m
49m m

1 2 3 4 5 6 7
35
m
10 m
0m
m
mm L1
125

L2
LOAD
L3

LN

9
®

Three Phase Energy Meter


HFEM-37000CTCOM-MT
THREE PHASE ENERGY METER
• Multi-measurement : kWh, kVARh, kW, kVAR, kVA, PF, Hz, Dmd, V, A, etc.
• LCD display with backlit
• Bi-directional measurement IMP & EXP
• 5A CT operated
• RS485 Modbus
• Real time clock
• Multi tariffs
• 2 Pulse outputs
• 7 Modules, 125mm width

Specification Multi-tariff
Nominal voltage(Un) 3x230/400VAC time clock accuracy ﹤1s/day
Operational voltage 80%~120% of Un Tariff 4
Insulation capabilities Time segments 10
- AC voltage withstand 4kV for 1 minute Accuracy
- Impulse voltage withstand 6kV-1.2μS Voltage,Current 0.5%
Basic current (Ib) 5A Frequency 0.2% of mid-frequency
Operational current range 0.4% Ib-Imax Power factor 1% of unity (0.01)
Over current withstand 20 Imax for 0.01s Active power , Apparent power ±1% of range maximum
Operational frequency range 50/60Hz Reactive power ±1% of range maximum
Power consumption per phase ≤ 2W/10VA Reactive energy(Varh) Class 2
Display LCD Active energy (Wh) Class 1
Max reading 99999999 kWh/kVarh Modbus
Performance criteria Bus type RS485(semi-duplex)
Operating humidity ≤ 90% Protocol Modbus RTU
Storage humidity ≤ 95% Baud rate 1200/2400/4800/9600bps
Operating temperature -25°C - +55°C Address range 1-247
Storage temperature -40°C - +70°C Max. Bus loading 64pcs
Reference temperature 23°C± 2°C Communication distance 1000M
International standard IEC 62053-21 / EN50470-3 Parity EVEN/ODD/NONE
Accuracy class Class 1 Data bit 8
Installation category CAT III Stop bit 1
Mechanical environment M1 Pulse Output
Electromagnetic environment E2 Pulse outputs 2
Degree of pollution 2 Pulse output type Passive
Protection against penetration of Pulse Output 1 Configurable
IP51(indoor)
dust and water Pulse width 200/100(default)/60ms
Insulating encased meter of Pulse output 2 1000imp/kWh
II
protective class
Electrostatic discharges 8kV contact / 15kV air gap
Electromagnetic HF fields IEC 61000-4-3
Electrical fast transients 4kV

Dimension Wiring Diagram

L1 L2 L3 N

B A GND
2 1
24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8
65 mm
49m m

24 23 22 21 20 19

35
m
10 m
0m 1 2 3 4 5 6 7
m
mm
1 25

L1
S1
P1
L2 S1
P1 LOAD
L3
S1
P1

10
®

11

12