APPLICATION CONSTRUCTION
The H07RN-F flexible cable is designed for use in installations Type:
that involve moving equipment, electric appliances, and H07RN-F
building sites. It is also suitable for motors in lifting Conductor:
appliances, machine tools, and other heavy-duty applications. Bare Copper, Class 5 according to IEC 60228
When the installation has built-in protection, this cable can be Insulation:
rated up to 0.6/1 kV. It is recommended for use in dry, damp, Ethylene-propylene rubber (EPR) type EI7 according to
or wet indoor and outdoor workshops, including those in EN50363-1
explosive atmospheres (such as ATEX), subject to compliance Outer Sheath:
with country regulations and additional recommendations. Chlorinated Polyethylene rubber (CPE) TYPE EM7 according
Additionally, it can be used in industrial and agricultural to EN50363-2
workshops, as well as refrigeration installations. Separator:
A non-woven separator will be applied between insulated
Installation of this cable in an open-air environment does not
conductor & jacket for size ≥10mm2
require any special measures. On the other hand, if it is
Sheath Colour:
intended for burial, it must be provided with extra mechanical
Black
protection.
This cable is designed to operate continuously with a
maximum conductor temperature of +90°C. In the event of a CORE IDENTIFICATION
short circuit, the conductor temperature can reach up to 1 core: White
+200°C. The permissible current rating is determined by
considering an ambient temperature of 30°C and a maximum 2 core: Brown Blue
operating and conductor temperature of 90°C. Furthermore, 3 core: Yellow/Green Brown Blue
this cable complies with the European Directive RoHS and
possesses FT2 UL flame retardancy. 4 core: Yellow/Green Brown Black Grey
5 core: Yellow/Green Blue Brown Black Grey
STANDARDS
Flammability:
EN 60332-1-2: 2004, FT2 UL
Reference standards:
EN 60228, EN 50363-1, EN 50363-2-1, EN 60332-1-2, IEC 60332-1-
2, IEC 60245-4
EN 50525-2-21/IEC 60502-1
LEAD FREE Rated Mechanical Cable Chemical Water Proof Max.conductor Oil Resistance
Yes Voltage uo/U resistance to Flexibility Resistance Good temp.in service Yes
(Um) impacts Flexible Accidental 90 °C
600/1000 V Very Good
SINGLE CORE
MAX conductor DC Insulation
Conductor Size Sheath Thickness Overall Diameter Approx. Weight
resistance at 20℃ Thickness
TWO CORE
MAX conductor DC Insulation Sheath Overall Approx.
Conductor Size
resistance at 20℃ Thickness Thickness Diameter Weight
THREE CORE
MAX conductor DC Insulation Sheath Overall Approx.
Conductor Size
resistance at 20℃ Thickness Thickness Diameter Weight
FOUR CORE
MAX conductor DC Insulation Sheath Overall Approx.
Conductor Size
resistance at 20℃ Thickness Thickness Diameter Weight
FIVE CORE
MAX conductor DC Insulation Sheath Overall Approx.
Conductor Size
resistance at 20℃ Thickness Thickness Diameter Weight