Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

*LOANo bt3 /mvVNL J Reuoe/23-24 20|·2 02

LOANo6Is / rmv WNLJReul23-24 dt 20||:2021

APPENDIX- A.1 TAMPER CONDITIONS FOR SINGLE PHASE METER


Phasc - Ncutral Conncction Normal Phasc - Ncutral Conncction Revcrscd

1S 2S 2L 1L
1S 2s 2L 1L|
NORMAL WIRING
NOT TAMPERED tiLOAD DLOAo
CONDITION - 1 P CONDTION -2
R E R

PHASE AND NEUTRAL 15 25 2L1 1S 25 2L1L


CURRENT REVERSED P N
LOAD LOAD
TAMPER CONDITION. 3 GONDITION -4
R E

FULL LOAD 1S 2S 2L 1L
1S 2S 2L 1L
EARTH RETURNED
dLOAD P CONDTION -6 LOAD
TAMPER CONDITION -5
R. E R
FULL LOAD
EARTH RETURNED 1s 2S 2L 1L
AND
CURRENT REVERSED P
LOAD CONDITION . 7
N
LOAD coNDITION -8
TAMPER
R E R

1S 25 2L 1L 1S 2S 2L1L
PARTIAL LOAD
EARTH RETURNED LOAD
N
LOAD
CONDITION . 10 LOAD
TAMPER CONDITION -9
R
PARTIAL LOAD
EARTH RETURNED 1$ 2S 21 1L
1s 2S 2L 1L
AND
CURRENT REVERSED
LOAD -P
TAMPER CONDITION 11 LOAD cONDITKON- 12
R

NEUTRAL
CURRENT REVERSED 1S 25 2L 1L |1$ 2s 2L 1L

TAMPER
tLOAD LOAD5 P
CONDITON - 13 CONDITON -14
R R

PHASE 1s 2S 2L 1L
CURRENT REVERSED 1S 2S 2L 1L

LOAD hLOAO
N
TAMPER CONDTION 15 CONDITION - 16
NN
R
DIRECTION REVERSED EARTH IAMPERED NTRAL DISTURBENGE
LEGEND :

Aeering Wors ÉE (Comm) (Con


EE (n MVNL MVVNL
AVNL

EEMWL
ROSS) E(RDSS) SE (RDSs)
NL
CERDSS)
MVVNL
*LOA No63/MWNL/Rew/23-24 d 20{h20r
* Lo mNo 1S/myVNL/Revany23-24 dt20-1)·203

Phase - Neutral Connection Normal Phase - Neutral Connection Reversed


PARTIAL LOAD
EARTH RETURNEO
AND 1S 2S 2L 1L 1S 2S 2L 1L
NEUTRAL
CURRENT REVERSED p.
,LOAD -N

TAMPER CONDITION 17 CONDITION - 18P


PARTIIAL LOAO R
EARTH RETURNED
AND 1s 2s 2L 1L 1S 25 2L 1L
PHASE
CURRENT REVERSED LOAD LOAD
TAMPER CONDITION 19 N CONDITION -20

CURRENT BYPASSED 1s 23 2L 1L

N
GLOAD
TAMPER CONDITION -21
R E NM R E NM
NEUTRAL REMOVAL
1S 2S 2L 1L 1S 2S 2L 1L

TAMPER HLOAD LOAD


CONDITION- 22 CONDION -23
RE N RE NM
NEUTRAL REMOVAL
& CURRENT 1S 25 2L 1L 1s 2S 2L 1L
REVERSED

TAMPER
LOAD CONDITION - 24
LOAD I
CONDITION- 25
R E NN R E NM
NEUTRAL
18 2S 2L 1L
DISTURBANCE 1S2S 2L 1
TAMPER
cONDITION -26A CONDITION -26B
RE NM RENN
NEUTRAL 1S 2S 2L 1L
1S 25 2L 1L
DISTURBANCE

TAMPER
LOAD LOAD
cONDITON- 27A CONDIIION - 27B
R E NM R E NM
o o
NEUTRAL
DISTURBANCE 1S 2S 2L 1L 1s 2S 2L 1L
L LOAD
TAMPER LOAD
CONDITION 28A CONDITION 28B
R E NM
LEGEND: DIRECTION REVERSED O- FARTH TAMPERED O- NEUTRAL DISTURBENCE

SET) EE (Comm) CE (Comm)


MVVNL MVVN MVVNL MyYNL
*RUSS) SE(RÖSS)
MVVNL
CE(RDSS)
MVVNL

2
&LOANo 613 /MwvNL/Rewp l2324 d20||-2027
20 |12023

Phase Current Reversed, Voitage 2S 2L


Reversed

Neutral Current Reversed, Voltage 1s.25 2L


Interchanged & Reversed

25 i2L
Partial Load Earth Returned &
Neutral Current Reversed, Voitage
Reversed

Partial Load EarthReturned & 15 2S :2L


Neutral Current Reversed, Voltage
Reversed and Voltage Interchanged

1S 2S 2L

Diode Reversed in Neutrat

EE{RDSS)
EE (RDSS)

Diode Reverspdyseutral, Lo
Earthed

DELHI CE(RD
MVVNL
EPm CE (Coim)

You might also like