Column Footing (2239-3) (r4)
Column Footing (2239-3) (r4)
P.C.C.(1.4.8)4" OR AS REQD. 2300 X 3050 2600 X 3350 2600 X 3350 2100 X 2850 2500 X 3250 2800 X 3700 2300 X 2750
SIZE 2300 X 3050 1800 X 2550 2200 X 2950 2500 X 3400 NOTES :-
2000 X 2750 2300 X 3050 2000 X 2450
D d D,d 700,450 750,550 750,550 600,450 750,450 850,550 600 * THIS DRAWING SHOULD NOT BE USED FOR EXECUTION
UNLESS IT IS STAMPED AND SIGNED
STEELAT #12 @110 C/C #16 @150 C/C #16 @150 C/C #12 @125 C/C
R.C.C. FOOTING #16 @150 C/C #12 @115 C/C #12 @100 C/C * THIS DRAWING MUST BE READ ALONG WITH THE
BOTHWAY
SIZE 300 X 1050 300 X 1050 300 X 1050 300 X 1050 300 X 1050 300 X 1200 230 X 925 WORKING / ARCHITECTURAL DRAWING
GROUND FLOOR
* THIS DRAWING SHOULD NOT BE SCALED OFF
M-30/Fe-500 STEEL 18#20 16#20 18#20 16#20 16#25 18#25 10#20 ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED
SIZE 300 X 1050 300 X 1050 230 X 925 * STEEL FE-500 EXCEPT FOR 6 MM DIA BARS
FIRST FLOOR 300 X 1050 300 X 1050 300 X 1050 300 X 1200
M-30/Fe-500 STEEL * GRADE OF CONCRETE M-30 & M-25 UNLESS SPECIFIED
18#20 16#20 18#20 16#20 16#25 18#25 10#20
SIZE 230 X 1050 230 X 1050 230 X 1050 230 X 1050 ----- ----- -----
SECOND FLOOR ----- ----- ----- STRUCTURAL CONSULTANT'S responsibility shall remain limited to
M-25/Fe-500 STEEL 18#20 16#20 18#20 16#20 ----- ----- ----- safe and sound structural design as transmitted by this drawing
and we shall NOT REMAIN RESPONSIBLE for
SIZE 230 X 1050 230 X 1050 230 X 1050 230 X 1050 ----- ----- -----
THIRD FLOOR ----- ----- ----- a) Safety of old structure during demolition.
M-25/Fe-500 STEEL 16#20 14#20 16#20 14#20 ----- ----- -----
b) Safety of any adjoining building / persons staying in adjoining
SIZE 230 X 925 230 X 925 230 X 925 building / persons & properties on adjoining roads.
230 X 925 ----- ----- -----
FOURTH FLOOR ----- ----- ----- c) Safety of construction worker / any personnel at work site
M-25/Fe-500 STEEL 8#20 12#16 8#20 12#16 ----- ----- ----- during construction
4#16 4#16
SIZE 230 X 925 230 X 925 ----- ----- ----- d) Correctness / safety of any temporary structure, scaffolding, shuttering,
230 X 925 230 X 925 centering erected @ site and any injury to any personnel arising out of
FIFTH FLOOR ----- ----- -----
M-25/Fe-500 STEEL 8#20 10#16 8#20 10#16 ----- ----- ----- their accidents.
4#16 4#16 e) Accident occurring due to premature deshuttering faulty / substandard
SIZE 230 X 925 230 X 825 230 X 925 230 X 825 ----- ----- ----- construction material or workmanship / faulty construction procedure.
SIXTH FLOOR ----- ----- -----
6#16 6#16 f ) The STABILITY OF STRUCTURE , if any changes or modifications are
M-25/Fe-500 STEEL 10#16 10#16 ----- ----- -----
4#12 4#12 made in this drawing without his written consent
SIZE 230 X 925 230 X 825 230 X 925 230 X 825 ----- ----- -----
SEVENTH FLOOR ----- ----- ----- REVISIONS :-
M-25/Fe-500 STEEL 6#16 6#16 6#16 6#16 ----- ----- -----
4#12 4#12 4#12 4#12 REV. NO. DESCRIPTION DATE
SIZE 230 X 925 230 X 825 230 X 925 230 X 825 ----- ----- -----
TERRACE FLOOR ----- ----- ----- 1 REVISED AS / DRAWING 27/03/23
M-25/Fe-500 STEEL 6#16 6#16 6#16 6#16 ----- ----- -----
4#12 4#12 4#12 4#12 2 REVISED AS / DRAWING 17/04/23
3 REVISED AS / DRAWING 04/12/23
4 REVISED AS / DRAWING 15/12/23
TERRACE FLOOR
M-25/Fe-500
SIZE
STEEL
230 X 825
6#20
4#16
230 X 825
6#16
4#12
230 X 825
6#16
4#12
230 X 825
10#16
230 X 825
6#16
4#12
230 X 825
6#16
4#12
230 X 825
10#16