Professional Documents
Culture Documents
Pump Hydraulic Calculation
Pump Hydraulic Calculation
Pump Hydraulic Calculation
Sketch
Suction Discharge
pump inlet sub header header pump outlet sub header header
Pipe length m 0 0 0 0 0 0
Pipe size inch 6 8 12 6 8 10
Line Schedule 40 40 40 40 40 40
Line Class 150 150 150 150 150 150
Pipe Roughness inch 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018
Fittings quantity
* tee flow thru no. 0 0 0 0 0 0
* tee branch no. 0 0 0 0 0 0
* elbow 90 deg LR no. 0 0 0 0 0 0
* elbow 90 deg screwed no. 0 0 0 0 0 0
* elbow 45 deg no. 0 0 0 0 0 0
* elbow 45 deg screwed no. 0 0 0 0 0 0
* gate valve no. 0 0 0 0 0 0
* ball valve no. 0 0 0 0 0 0
* globe valve no. 0 0 0 0 0 0
* butterfly valve no. 0 0 0 0 0 0
* check valve swing no. 0 0 0 0 0 0
* check valve lift no. 0 0 0 0 0 0
* check valve stop lift no. 0 0 0 0 0 0
* check valve tilting disk no. 0 0 0 0 0 0
* foot valve hinged disc no. 0 0 0 0 0 0
* foot valve poppet disc no. 0 0 0 0 0 0
* reducer N*K n*k 0 0 0 0 0 0
* entrance loss no. 0 0 0 0 0 0
* exit loss no. 0 0 0 0 0 0