GENERAL NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS EXCEPT THE ELEVATIONS


ARE IN METERS.
GRATING COVER 2. COATING AND PROTECTION FOR CONCRETE SURFACES SHALL BE IN
PRECAST CONCRETE (SEE NOTE 3) ACCORDANCE WITH AMIES-Q-001 AND AMIES-H-003.
OF DITCH REMOVABLE COVERS
6 3. CONCRETE AND GRATING COVERS SHALL BE DESIGNED TO RESIST THE
4,5 MINIMUM LOADS SPECIFIED IN AMIES-M-001.
50CL. -

(SEE TABLE-2)
OF DITCH OF DITCH - 4. THE LOCATION OF JOINTS FOR RC DITCH CAN BE ADJUSTED CONSIDERING
T.O.D T.O.D T.O.D CONSTRUCTION SEQUENCE.

'T'
SURFACE PROTECTION
(SEE NOTE 2)
D12@200
(VAR.)

(VAR.)

(VAR.)
H

H
D12@200

100

100

100
(SEE TABLE-1)

(SEE TABLE-1)
B.L B.L B.L

(SEE TABLE-1)
150 OR 200

(TYP.)
75CL.

250
'B'

'B'

50 'B'

'B'

50 'B'

'B'
(TYP.)
75CL.

50
50
D16@200

50
LEAN CONC. D16@200 LEAN CONC. LEAN CONC.
50 'A' W 'A' 50 50 'A' W 'A' 50 50 'A' W 'A' 50
150 OR 200 (SEE PLAN) 250 (SEE TABLE-1) (SEE PLAN) (SEE TABLE-1) (SEE PLAN) (SEE TABLE-1)

H<1200 : D12@200
H ≥ 1200 : D16@200
WSW RC DITCH WITH WSW RC DITCH WITH
PRECAST CONCRETE COVER GRATING COVER
WSW RC OPEN DITCH

1 DETAIL 2 DETAIL 3 DETAIL


- SCALE N.T.S - SCALE N.T.S - SCALE N.T.S

6
35 50
GRATING COVER (GALV.) GRATING COVER (GALV.)
INSIDE
(I-32) 10 (I-50)
5

15
TABLE-1 <DITCH DEPTH AND THICKNESS>

50 5
5

CHANNEL THICKNESS
INTERNAL DEPTH
35

(H) 'A' 'B'


L-35x35x3t L-50x50x5t
OUTSIDE 1200 > H 150 MIN. 150 MIN.
(GALV.) (GALV.)
1200 ≤ H < 2400 200 MIN. 200 MIN.
ANCHOR BAR ANCHOR BAR
H ≥ 2400 250 MIN. 250 MIN.
Ø10@300, L=150 Ø10@300, L=150 JOINT SEALANT
(BITUMINOUS MASTIC
OR HOT BITUMEN) TABLE-2 <CONCRETE COVER>

GRATING FOR LIGHT TRAFFIC AREA GRATING FOR HEAVY TRAFFIC AREA CONTROL JOINT CHANNEL
INTERNAL WIDTH (W)
C T
(C/C MAX. 5M)
1000 ≥ W 200
4 DETAIL 5 DETAIL 20 1000 < W
W+2A
250
- SCALE N.T.S - SCALE N.T.S
INSIDE

15
HDAI-370102 GENERAL NOTES CONCRETE WORKS

OUTSIDE HDAI-370101 GENERAL NOTES CIVIL WORKS

Drawing No DESCRIPTION
1000
1000 JOINT SEALANT REFERENCE DRAWINGS
POLYSTYRENE PANEL
5@EQ SPA=850 75CL (BITUMINOUS MASTIC
75CL (THK 20)
300 50 300 50 300 OR HOT BITUMEN)
75CL

D16@200 EXPANSION JOINT


(C/C MAX. 15M)
=

N@200=(C-150)

OPNG 1 IFC 12-OCT-2023 ISSUE FOR CONSTRUCTION Y.B. LEE D.K. KIM Y.B.IM
(50X200)
0 IFR 07-SEP-2023 ISSUE FOR REVIEW Y.B. LEE D.K. KIM Y.B.IM
A B
C
200
C

Issued Reviewed Approved


- - Rev. Step Rev. Date Revision Description
by by by

300 50 300 50 300 D16@200


AMIRAL
=

D16@200 PROJECT
75CL

T This document is the property of AMIRAL and shall not be disclosed to third parties or reproduced without permission of the owner.

This document has been generated by an Electronic Document Management System. When printed it is considered as a for information
OPNG
CONCRETE COVER DETAIL REINF CONCRETE COVER DETAIL (50X200)
only copy. The controlled copy is the screen version and it is the holder's responsibility that he/she holds the latest valid version.

A SECTION B SECTION STANDARD DETAILS FOR OPEN DITCH


6 DETAIL
SCALE N.T.S - SCALE N.T.S - SCALE N.T.S
-
Doc Type: STD Discipline: CIV Phase: DE Class: 2 System / Subsystem: NA Equipment Type: NA
Contractor Site
Document - Reference:
-
Number :
Company Rev: Scale: Format: Sheet:
Document SA-AMI-000-HDAI-370106
ID : 1 N.T.S A1 001