LG Electronics Distribute by :
http://lge.com
http://partner.lge.com
http://lghvacstory.com
CONVENIENCE
Direct drive fan motor
Easy set-up method (by ESP function)
ULTIMATE PERFORMANCE
Superior efficient ultimate inverter compressor
Applied BLDC motors for all fans
Superior level IEER 18.3 (25RT) & 19.0 (20RT)
2 3
LINE UP
7.5 / 10RT
AK-W110LH00
Restaurant Theater AK-W130LH00
Cooling &
12.5 / 15RT
Heating
20 / 25RT
Economizer [PKEMD1CA0]
4 5
SUPERIOR EFFICIENCY ADVANCED KEY COMPONENTS FOR HIGH ENERGY EFFICIENCY
High energy efficiency with LG’s cutting-edge core components and Inverter leading technology.
Pressure Sensor
Supply of Energy
WASTE OF
ENERGY
Required Energy
Inverter Compressor
Supply of Energy
Required Energy
Maximized
Energy
40% Operation 100% Operation 40% Operation Efficiency
6 7
SUPERIOR EFFICIENCY
EER
- Superior electricity charges by auxiliary device
10.0
EER
93% 20
15
Additional Cost
10
35 °C 27.5 °C (About 5% of product price)
5
24.25 Power Input (kW)
48%
12.56 0 1.0
27.5 35 40 46 48 Max
Outdoor Temp. (°C)
Energy Efficiency1)
Outdoor Temp. (°C) 27.5 35 40 46 48
(W / W)
Unit (Cooling only) + Electric Heater 2)
EER 19.3 10.0 8.0 6.4 5.9
35 °C 27.5 °C Power Input (kW) 12.56 24.25 30.12 35.98 37.1 1) Energy efficiency is based on the following conditions :
※ Model : LG AK-Q300DC01 - Indoor Temp. 21.1°C (70°F) DB / 15.6°C (60°F) WB
- Outdoor Temp. 8.3°C (47°F) DB / 6.1°C (43°F) WB
2) Specification : 25kW / 460V / 3Ø / 60Hz
10 10
3.38
Capacity (RT)
Capacity (RT)
8 8
Typical Number
2 2
of Visitors
0 0
0 5 10 15 20 24 0 5 10 15 20 24
Cooling Load (With typical number of visitors) Cooling Load (With typical number of visitors)
Energy Consumption Wasted Energy Energy Consumption
10 10
Capacity (RT)
Capacity (RT)
0 0
0 5 10 15 20 24 0 5 10 15 20 24
Cooling Load (With fewer visitors) Cooling Load (With fewer visitors)
Energy Consumption Wasted Energy Energy Consumption
8 9
SUPERIOR EFFICIENCY
ANNUAL ENERGY SAVINGS ESTIMATION (Cairo, Egypt) ANNUAL ENERGY SAVINGS ESTIMATION (Luxor, Egypt)
Electricity consumption are expected to decline by 54 % compared to on/off model. Electricity consumption are expected to decline by 51% compared to on/off model.
Electricity Consumption Electricity Cost 616,448 EGP Electricity Consumption Electricity Cost 747,840 EGP
Currency (EGP) Cost saving after 10 years Currency (USD) Cost saving after 10 years
71,912 115,059 1,400,000 91,176 145,882 1,600,000
kWh/year EGP/year On/Off Inverter kWh/year EGP/year On/Off Inverter 1,458,816
1,150,592 1,400,000
1,200,000
1,200,000
1,000,000
33,384 53,414 44,436 71,098 1,000,000
800,000 kWh/year EGP/year
kWh/year EGP/year
800,000
600,000
600,000
54% 54% 51% 51% 710,976
400,000
Decrease Decrease 534,144 Decrease Decrease 400,000
200,000 200,000
0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
On/Off Inverter On/Off Inverter Years On/Off Inverter On/Off Inverter Years
[Condition] [Condition]
- Capacity : 25RT Single Package - Capacity : 25RT Single Package
- Operation time : 8am ~ 8pm, 12months - Operation time : 8am ~ 8pm, 12months
- Cooling partial load and power consumption calculated based on yearly weather data (target indoor temperature : 24°C) - Cooling partial load and power consumption calculated based on yearly weather data (target indoor temperature : 24°C)
* This result can be different depending on actual environment * This result can be different depending on actual environment
800,000
27,514 44,022
kWh/year EGP/year
600,000
440,224
55% 55% 400,000
Decrease Decrease
200,000
0
1 2 3 4 5 6 7 8 9 10
On/Off Inverter On/Off Inverter Years
[Condition]
- Capacity : 25RT Single Package
- Operation time : 8am ~ 7pm, 12months
- Cooling partial load and power consumption calculated based on yearly weather data (target indoor temperature : 24°C)
* This result can be different depending on actual environment
10 11
SUPERIOR EFFICIENCY
Latent heat load Sensible heat load Latent heat load Sensible heat load
- Excessive latent heat elimination regardless of humidity - Comfortable environment by making the room less dry
- Waste Energy to eliminate latent heat - Increased Seasonal Efficiency
Wet condition
In wet summer season, the system senses the high humidity level and increases operating ratio to decrease humidity level rapidly for
making room condition in comfort zone.
Wet Wet
35°C 85% 2) 35°C 85% 2)
Summer Summer
Temp.(°C)
Temp.(°C)
Te1) Te1) - α
Refrigerants Refrigerants
Target Target
Time Time
12 13
CONVENIENCE DIRECT DRIVE FAN MOTOR
Easy maintenance
Beltless direct drive system is easy to maintain and cost effective.
No additional parts
Additional parts
(Reduced parts and labor costs)
Easy installation
By applying a high static pressure motor, It has wide E.S.P coverage and easy to set the air volume.
- It is necessary to change the pulley and motor to change airflow - Set RPM by simple touch on remote control to change airflow
Simple setup
High 140
※ Motor operation range (Based on 9,400 CFM) ※ Motor operation range (Based on 9,200 CFM)
0.1 0.4 0.5 1.0 1.1 1.4 0 in.Aq Largest 10HP BLDC Motor 2.0 in.Aq
in.Aq in.Aq in.Aq in.Aq in.Aq in.Aq
14 15
CONVENIENCE
Filter Rack
Replaceable
2 inch Filter1)
16 17
RELIABILITY ULTIMATE INVERTER COMPRESSOR
By applying world class technology of Multi V, superior efficient and reliable operation has been achieved.
18 years of inverter technology applied to LG new single package.
1
3 3
3 3
2
2
Automatic detection
DC peak detection No need
and blocking Continuous
Operation Range
N phase reverse wiring
No detection Automatic detection
(3 phase only)
18 19
RELIABILITY
BLACK FIN
The black coating with enhanced complex resin is applied for strong protection from various corrosive external Black Fin‘s performance of corrosion resistance is improved based on Conventional Fin.
conditions such as salt contamination and air pollution including fumes from factories. This improvement in durability
prolongs the product’s lifespan and lowers both the operational and maintenance costs.
1,000%
10,000
hours
600%
3,000
Fog1) Dry Wet2) hours
(35°C, 2hr) (70°C, 2hr) (50°C, 2hr)
500
Process hours
Repeated Conventional Fin Black Fin
20 21
CUSTOMIZED CONTROL
NEW DESIGN REMOTE CONTROLLER DESIGN 3rd PARTY BMS SYSTEM COMPATIBILITY
LG Individual Controller provides intuitive GUI with color LCD and touch type interface button. LG Inverter Single Package can be connected with gateway products for different protocols such as Modbus, BACnet
and LonWorks. And gateway product offers self diagnosis interface thanks to smart GUI included.
Standard III LG HAVC System LG BMS Gateway BMS System
Controller Individual
ACP 5
Multi V ACP Lonworks
LG Protocol BMS Protocol
Single / Multi
AC Smart 5
ERV
※ Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Conventional New
Save
22 23
CUSTOMIZED CONTROL
On
09:00 13:00 18:00 21:00 0:00 09:00
Highest Start End
outdoor temp.
New Inverter
Standard III wired Remote Controller setting possible
2 SET POINT CONTROL
Auto Changeover can manage room temperature with changing Heating / Cooling mode and Compressor-off
automatically. With setting heating and cooling set temperature just one time, comfortable condition will continue at
all times. It is also possible to reduce the energy use by broadening the set temperature gap of cooling and heating.
Low-noise operation
Fan Mode (Comp. Off) * Dead Band
On
Off
+0.5°C
09:00 13:00 18:00 09:00
Start End -0.5°C Heating Set
※ Low-Noise Operation requires Standard III wired Remote Controller. (18 ~ 30°C)
Heating Mode (Comp. On)
24 25
SPECIFICATION
kW kW
26.4 / 34.6 34.3 / 38.1 51.0 / 64.5 70.0 / 90.3 81.0 / 101.1
(Rated/Max) (Rated/Max)
Net Capacity Net Capacity
Btu/h Btu/h
90,000 / 118,000 117,000 / 130,000 174,000 / 220,000 240,000 / 308,000 276,000 / 345,000
(Rated/Max) (Rated/Max)
Cooling Capacity Cooling Capacity
kW kW
27.0 / 35.2 35.2 / 39.0 52.6 / 66.1 72.3 / 92.3 83.6 / 103.8
(Rated/Max) (Rated/Max)
Gross Capacity Gross Capacity
Btu/h Btu/h
91,960 / 119,960 120,000 / 133,000 179,500 / 225,500 246,900 / 314,900 285,200 / 354,200
(Rated/Max) (Rated/Max)
Power Input Cooling kW 7.37 / 15.0 10.08 / 15.5 15.26 / 30.00 Power Input Cooling kW 21.3 / 32.1 26.0 / 39.2
EER Btu/Wh 12.2 11.6 11.4 EER Btu/Wh 11.3 10.6
SEER Btu/Wh 20 19 18.5 SEER Btu/Wh 19.0 18.3
Power Supply V, Ø, Hz 380~415, 3, 50/60 380~415, 3, 50/60 380~415, 3, 50/60 Power Supply V, Ø, Hz 380~415, 3, 50/60 380~415, 3, 50/60
Running Current Cooling Rated A 11.8 15.9 23.4 Running Current Cooling Rated A 33.0 40.0
Wiring Connections Power Supply Cable (Included Earth) No. x mm2 4C × 13.3 4C × 13.3 4C × 21.2 Wiring Connections Power Supply Cable (Included Earth) No. x mm2 4C × 33.6 4C × 33.6
WxHxD mm 1,130 × 1,242 × 2,250 1,130 × 1,242 × 2,250 2,230 × 1,242 × 2,400 WxHxD mm 2,230 × 1,242 × 3,520 2,230 × 1,242 × 3,520
Dimensions 44-1/2 × 48-29/32 44-1/2 × 48-29/32 87-25/32 × 48-29/32 Dimensions
WxHxD inch WxHxD inch 87-25/32 × 48-29/32 × 138-19/32 87-25/32 × 48-29/32 × 138-19/32
× 88-19/32 × 88-19/32 × 94-1/2
Net Weight kg (lbs) 440 (970) 440 (970) 705 (1,554) Net Weight kg (lbs) 915 (2,017) 915 (2,017)
Compressor Type - HSS DC SCROLL HSS DC SCROLL HSS DC SCROLL Compressor Type - HSS DC SCROLL HSS DC SCROLL
(#1, A Cycle) Motor Output W x No. 5,500 x 1 5,500 x 1 5,300 x 1 (#1, A Cycle) Motor Output W x No. 5,500 × 1 5,500 × 1
Compressor Type - HSS DC SCROLL Compressor Type - HSS DC SCROLL HSS DC SCROLL
(#2, B Cycle) Motor Output W x No. 5,300 x 1 (#2, B Cycle) Motor Output W x No. 5,500 × 1 5,500 × 1
Type - R410A R410A R410A Type - R410A R410A
Precharged Amount (A-circuit) g 9000 9000 5200.0 Precharged Amount (A-circuit) g 9000.0 9000.0
Refrigerant Refrigerant
Precharged Amount (B-circuit) 5200.0 Precharged Amount (B-circuit) 9000.0 9000.0
Control - EEV EEV EEV Control - EEV EEV
Type - FW68D FW68D FW68D Type - FW68D FW68D
Refrigerant Oil Refrigerant Oil
Charged Volume cc x No. 1,500 x 1 1,500 x 1 1,200 x 1 Charged Volume cc x No. 1,500 × 1 1,500 × 1
Type - Plug Fan Plug Fan Plug Fan Type - Plug Fan Plug Fan
Diameter mm (inch) Direct Direct Direct Diameter mm (inch) Direct Direct
Indoor Side Fan Indoor Side Fan
Nominal m3/min 85 113 170 Nominal m3/min 227 261
Air Flow Rate Air Flow Rate
Nominal ft3/min 3,000 4,000 6,000 Nominal ft3/min 8,000 9,200
Dehumidification Rate ℓ/h 9.1 12.1 18.1 Dehumidification Rate ℓ/h 24.1 30.1
Outdoor Side Black fin / Black fin / Black fin / Outdoor Side Black fin / Black fin /
Fin Type - Fin Type -
Heat Exchanger Wide Louver plus Wide Louver plus Wide Louver plus Heat Exchanger Wide Louver plus Wide Louver plus
* In case of Heatpump model, AHRI certification program is limited up to 20RT model. so, LG will provide LG laboratory test report of 25RT model. * In case of Heatpump model, AHRI certification program is limited up to 20RT model. so, LG will provide LG laboratory test report of 25RT model.