Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

51'

VER VER VER VER


5'-1"X3'-1" 5'-1"X3'-1" 5'-1"X3'-1" 5'-1"X3'-1"
W1 W1 W1 W1
2 2 2 2
M.BED W W BED BED W W M.BED
10'-9"X10'-0" 10'-9"X-10'-0" 10'-9"X-10'-0" 10'-9"X10'-0"
W

W
W1 W1
2

2
D D D D
D2
1 31 3 31 3 1
D2
D D D1 D D1 D
BATH BATH
HW

HW
2

2
W3 W3
6'-6"X3'-7" 6'-6"X3'-7"

34' DINING DINING


12'-9"X8'-4" D D
31 3 13'-9"X8'-4"
D D1
D

D
D2 D2
1

1
BATH BATH
6'-6"X4'-4" 6'-6"X4'-4"

D
3

3
D1 D1
HW

HW
2

2
W3 W3
UP
5'-4"X2'-0"

D2 D2
D

D
D2 D2
1

1 5'-4"X2'-0"
VER

VER
KITCHEN
KITCHEN LIVING 7'-0"X8'-7"
7'-0"X8'-7" 10'-8"X7'-9" LIVING
10'-8"X7'-9"

UP

VER STAIR VER


HW W2 HW HW W2 HW
2 2 10'-8"X3'-1" 7'-3"X14'-6" 10'-8"X3'-1" 2 2

MAIN GATE

GROUND FLOOR PLAN


10'

6'-6"

FRONT SIDE ELEVATION


SOUTH SIDE ELEVATION
WEST SIDE ELEVATION EAST SIDE ELEVATION
2'

13' 3'

10'

10'

10'

10'

10'

10'

10'

10'

10'

7'

2'
SECTIONAL ELEVATION
8'-0" WIED ROAD

SEPTIC PROPOSED
TANK
BUILDING

8'-0" WIED ROAD

MATIDHALI-SHATMATHA SHATMATHA
ROAD

BSCIC STATE
OFFICE

LOCATION MAP
51'

3'-5" 10'-11" 11'-2" 11'-2" 10'-11" 3'-5"

3'-5" 3'-5"

C4 C2 C2 C4
C1

14'-10" 14'-10"

C2 C1 C1 C2
34' 34'

3'-6" 3'-6"

12'-9" 12'-9"

C4 C2 C3 C2 C4
C3

3' 3'

3'-5" 7'-5" 10'-8" 8'-1" 10'-8" 7'-5" 3'-5"

51'

COLUMN CENTER LINE LAYOUT


51'

3'-5" 10'-11" 11'-2" 11'-2" 10'-11" 3'-5"

3'-5" 3'-5"
GB3 GB3 GB3 GB3
C4 C2 C2 C4
C1

14'-10" GB2 GB2 GB2 GB2 GB2 14'-10"

C2 C1 C1 C2
34' 34'
GB1 GB1 GB1

12'-9" GB2 GB2 GB2 GB2 GB2 GB2 12'-9"

C4 C2 C3 C2 C4
C3
GB3 GB3 GB3 GB3 GB3
3' 3'

3'-5" 7'-5" 10'-8" 8'-1" 10'-8" 7'-5" 3'-5"

51'

GRADE BEAM LAYOUT


SLAB
10"

10-20mm dia bar

10mm dia
15"
@ 5"-7" c/c L/4 10mm dia
@ 5" c/c.
C1
10"

4-20mm dia bar+ 10mm dia


4-16mm dia bar L/2 @ 7" c/c.
15" 10mm dia
@ 5"-7" c/c COLUMN

C2
10" L/4 10mm dia
@ 5" c/c.
8-16mm dia bar PL

12" 10mm dia G.BEAM


@ 5"-7" c/c GL

C3
10mm dia
S.COLUMN
10" @ 5" c/c.

6-16mm dia bar

12" 10mm dia


@ 5"-7" c/c

LONG SECTION
C4
OF COLUMN

*** Use 60 Grade deformed bar

Column Cross Section


51'

3'-5" 10'-11" 11'-2" 11'-2" 10'-11" 3'-5"

3'-5" F4 F2 F1 F2 F4 3'-5"
5'-10" 6'-10" 7'-6" 6'-10"
C4 C2 C2 C4
C1
5'-10" 5'-10"
6'-10" 6'-10"
7'-6"
14'-10" 14'-10"

6'-10" 7'-6" 7'-6" 6'-10"

C2 C1 C1 C2
34' 34'
6'-10" 7'-6" 7'-6" 6'-10"
F2 F1 F1 F2

12'-9" 12'-9"
6'-10" 6'-10"
5'-10" 6' 6' 5'-10"

C4 C2 C2 C4
C3 C3
5'-10" 6'-10" 6' 6'-10" 5'-10"
3' F4 F2 F3 F3 F2 F4 3'

3'-5" 7'-5" 10'-8" 8'-1" 10'-8" 7'-5" 3'-5"

51'

FOUNDATION LAYOUT
PL
3"
3"

G. Beam 1'-6"
GL

4'-6"
12" 12"
20mm+16mm dia@
18" 18"
b S" C/C both way
D a
C.C 3"
B.F.S 3"

Sand Filling 3'-0"

LxS

B Direction
C

A Direction

FOUNDATION
Note- As per soil test report.

*** Use 60 Grade deformed bar


10mm-@8"c/c

D D D D 12mm-@5"c/c
31
D 3
D1 31
D 3
D1 10mm-@8"c/c
D

D
3

D1

D
D1

3
D1 D1 2nd Flight
Landing Beam
UP UP Weast slab 6"
T=10"
Landing Beam
R=6"

12mm-@5"c/c
10mm-@8"c/c
Beam
1st Flight 15"x10"
5-16mm dia

UP
STAIR STAIR
7'-3"X14'-6" 7'-3"X14'-6" *** Use 60 Grade deformed bar

MAIN GATE
STAIR REINFORCEMENT
HW W2 HW
2 2

STAIR CASE PLAN


51'

3' 5'-11" 10'-10" 11'-6" 10'-10" 5'-11" 3'

3' 3'

12'-2" 3' 3' 12'-2"

PROPOSED
BUILDING
34' 34'
1'
1'

17'-5" 17'-5"

SEPTIC
TANK
2' 3' 3'
4'-5"
2'-5"
2'-5" 8'-0" WIED ROAD 2'-5"
3' 7'-5" 30'-2" 7'-5" 3'

51'

SITE PLAN
5'-11" 11'-6" 5'-11"

3' 10'-10" 3' 3' 10'-10" 3'

b b
12'-2" 12'-2"
Section: 1-1
S= 10mm dia @ 4.5" c/c
2' b a a a b
L 2' L= 10mm dia @ 5.5" c/c
S All Binder = 10mm dia @
a
10" c/c

t= 5"
a a
17'-5" 17'-5"
Ext. Top Bar
a = 2-10mm dia ext. top
a a b b a a b = 1-10mm dia ext. top

a
2'
a *** Use 60 Grade deformed bar

2'
2' 7'-5" 7'-5" 2'

2'-5" 11'-6" 11'-6" 2'-5"

SLAB REINFORCEMENT
2-16mm dia ext. top A 2-16mm dia st. B 2-16mm dia ext. top

A B
3-20mm dia st.

10mm dia @ 6" c/c. 10mm dia @ 8" c/c.

LONG SECTION OF
G. BEAM 1
2-16mm dia st. 2-16mm dia st.

2-16mm dia ext. 10mm dia @


18" top. 18" 6"-8"-6" c/c.
10mm dia @
6"-8"-6" c/c.
3-20mm dia st.
3-20mm dia st.
10" 10"
SECTION A-A SECTION B-B

*** Use 60 Grade deformed bar

SORT SECTION OF
G. BEAM 1
2-16mm dia ext. top A 2-16mm dia st. B 2-16mm dia ext. top

A B
3-16mm dia st.

10mm dia @ 6" c/c. 10mm dia @ 8" c/c.

LONG SECTION OF
G. BEAM 2
2-16mm dia st. 2-16mm dia st.

2-16mm dia ext. 10mm dia @


15" top. 15" 6"-8"-6" c/c.
10mm dia @
6"-8"-6" c/c.
3-16mm dia st.
3-16mm dia st.
10" 10"
SECTION A-A SECTION B-B

*** Use 60 Grade deformed bar

SORT SECTION OF
G. BEAM 2
2-12mm dia ext. top A 2-12mm dia st. B 2-12mm dia ext. top

A 2-16mm dia st.+


B
1-12mm dia st.

10mm dia @ 6" c/c. 10mm dia @ 8" c/c.

LONG SECTION OF
G. BEAM 3
2-12mm dia st. 2-16mm dia st.

2-12mm dia ext. 10mm dia @


12" top. 12" 6"-8"-6" c/c.
10mm dia @
6"-8"-6" c/c.
2-16mm dia st.+
2-16mm dia st.+ 1-12mm dia st.
10" 10"
SECTION A-A 1-12mm dia st.
SECTION B-B

*** Use 60 Grade deformed bar

SORT SECTION OF
G. BEAM 3