10. For values of A falling to left of material line in the material chart,
Pa =
11. Name plate shows The Code stamping, MAWP, design temp.,
MDMT, and Extent of Radiography.
12. For the impact test requirement, use UCS 66 curve. If MDMT-
thickness combination falls on or above the curve, impact testing is
exempted. Additional Exemptions are given as per UG-20(f) and
UCS 68 (c).
13. ASME materials (SA) shall be used for code stamped vessel
fabrication instead of ASTM (A) materials.