Week 03 Task

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

‫‪Mansoura – Nasr City – Egypt‬‬

‫‪Tel: 0020-1093460618‬‬
‫‪Email: Info@asec.work‬‬

‫‪TASK -07‬‬

‫(‬ ‫)‬ ‫‪ (1‬ﻣﺎ ﻫﻮ اﻟﺨﺎﻣﺔ اﻟﻤﺴﺘﺨﺪﻣﺔ ﺗﺼ ﻴﻊ اﻻﻫﻮاد؟‬


‫‪ .A‬اﻟﺼﺎج اﻷﺳﻮد‬
‫‪ .B‬اﻻﺳﺘﺎﻧﻠ ﺲ‬

‫(‬ ‫)‬ ‫دا ﺖ اﻟﺴﺤﺐ ﻟﻼﻫﻮاد؟‬ ‫‪ (2‬ﻣﺎ ﻫﻮ اﻓﻀﻞ أﻧﻮاع اﻟﺨﺎﻣﺎت اﻟ ﺴﺘﺨﺪم‬
‫‪ .A‬اﻟﺼﺎج اﻟﻤﺠﻠﻔﻦ‬
‫‪ .B‬اﻟﺼﺎج اﻷﺳﻮد‬

‫(‬ ‫)‬ ‫‪ (3‬ﻣﺎ ﻫﻮ اﻟﺪا ﺖ اﻟﻤﺴﺘﺨﺪم ﻧﻈﺎم اﻟﺪﺧﺎن؟‬


‫‪ .A‬اﻟﺼﺎج اﻟﻤﺠﻠﻔﻦ‬
‫‪ .B‬اﻟﺼﺎج اﻷﺳﻮد‬

‫(‬ ‫)‬ ‫‪ (4‬اﻟﺼﺎج اﻟﻤﺠﻠﻔﻦ اﻟﺬي ﻌﺘ ﻏﺶ ﺗﺠﺎري؟‬


‫‪G60 .A‬‬
‫‪G90 .B‬‬
‫‪G120 .C‬‬

‫(‬ ‫)‬ ‫وﺣﺪة اﻟﻔﺎن ﻛ ﻞ واﻟﺼﺎج؟‬ ‫‪ (5‬ﻣﺎ اﺳﻢ اﻟﻤﺴﻠﻮب اﻟ ﻳﺘﻢ ﺗﻮﺻ ﻠﺔ ﺑ‬
‫‪EDL .A‬‬
‫‪Plenum Box .B‬‬

‫(‬ ‫)‬ ‫‪ (6‬ﻣﺎ اﻟﻬﺪف ﻣﻦ وﺿﻊ اﻟ ﺎﻧﻔﺲ ﺑ وﺣﺪة اﻟﺘﻜﻴ ﻒ واﻟﺼﺎج؟‬


‫‪ .A‬ﻣﺎﻧﻊ اﻫ از‬
‫‪ .B‬ﺳﻬﻮﻟﺔ اﻟﺘﻮﺻ ﻞ‬

‫(‬ ‫)‬ ‫ﻃﻮل ﻟﻠﻮﺻﻼت اﻟﻤﺮﻧﺔ ﻣﻦ اﻟﻨ ع ‪Connect Duct‬؟‬ ‫‪ (7‬اﻗ‬


‫‪1.5 m .A‬‬
‫‪4.3 m .B‬‬
‫‪Unlimited .C‬‬

‫(‬ ‫)‬ ‫ﻃﻮل ﻟﻠﻮﺻﻼت اﻟﻤﺮﻧﺔ ﻣﻦ اﻟﻨ ع ‪Air Duct‬؟‬ ‫‪ (8‬اﻗ‬


‫‪1.5 m .A‬‬
‫‪4.3 m .B‬‬
‫‪Unlimited .C‬‬

‫(‬ ‫)‬ ‫اﻟﺪﻛﺖ اﻟ ﺒ ة؟‬ ‫‪ (9‬اﻓﻀﻞ أﻧﻮاع ﺗﺠﻤﻴﻊ ﻣﻘﺎﻃﻊ اﻟﺼﺎج‬


‫‪TDC .A‬‬
‫‪TDF .B‬‬

‫(‬ ‫)‬ ‫‪ (10‬اﻟﻌﺰل اﻟﻤﺴﺘﺨﺪم ﻟﻠﺪا ﺖ ﻣﻦ اﻟﺪاﺧﻞ اﻟﻬﺪف ﻣﻨﻪ؟‬


‫‪ .A‬اﻟﻌﺰل اﻟﺤﺮاري‬
‫‪ .B‬اﻟﻌﺰل اﻟﺼﻮ‬
‫‪ .C‬ﻼﻫﻤﺎ‬
1 2 3 4 5 6 7
G G
Mansoura - 10 of Ramadan - Egypt
TASK-08 Tel: 0020-1093460618
Email: Info@asec.work

F F
Locker Equip Sterilize Clean Utility Recovery Producer Room
54 52 53 64 63
21 m² 8 m² 8 m² 52 m² 42 m²

A. DUCT DESIGN WITH DIMENSION


B. ESP CALCULATION
C. DUCT WEIGHT
D. DUCT ISOLATION AND CLADDING
Female Toilet Dirty Aera
55 51
15 m² 7 m²

ESP - AHU
E ............................................................. E

.............................................................
General Store
62
Sterilize
61
Clean Corridor
59
Sterilize
60
.............................................................
6 m² 6 m² 56 m² 7 m² ESP - FCU
.............................................................
.............................................................
Services
D
49
10 m²
............................................................. D
ESP - FAN
.............................................................
.............................................................
Rest
48
.............................................................
8 m² DUCT WEIGHT BY USING SHEET EXCEL
.............................................................
ALL AHU =
C ............................................................. C
Locker ALL FCU =
Male Toilet
47 .............................................................
17 m²
46 ALL FAN =
15 m² .............................................................
DUCT ISOLATION
Operation Operation
.............................................................
Corridor
Theater Theater
50
92 m² 58
40 m²
57
44 m²
.............................................................
DUCT CLADDING
.............................................................
B Dirty Corridor
56
............................................................. B
46 m²

A A
1 2 3 4 5 6 7
1 2 3 4 5 6 7
G G
Mansoura – Nasr City– Egypt
TASK-09 Tel: 0020-1093460618
Email: Info@asec.work

F F
Locker Equip Sterilize Clean Utility Recovery Producer Room
54 52 53 64 63
21 m² 8 m² 8 m² 52 m² 42 m²

A. PIPE DESIGN WITH DIMENSION


B. PUMP HEAD CALCULATION
C. HOOK UP DETAILS
D. BOQ OF PIPES
Female Toilet Dirty Aera
55 51
15 m² 7 m²

PUMP HEAD
E ............................................................. E

.............................................................
General Store
62
Sterilize
61
Clean Corridor
59
Sterilize
60
.............................................................
6 m² 6 m² 56 m² 7 m² HOOK UP FCU
.............................................................
SUPPLY LINE:
.............................................................
Services RETURN LINE:
D
49
10 m²
............................................................. D
HOOK UP AHU
.............................................................
SUPPLY LINE:
.............................................................
RETURN LINE:
Rest
48
.............................................................
8 m² HOOK UP PUMP
.............................................................
SUCTION LINE:
C ............................................................. C
Locker DISCHARGE LINE:
Male Toilet
47 .............................................................
17 m²
46 HOOK UP CHILLER
15 m² .............................................................
SUPPLY LINE:
Operation Operation
.............................................................
Corridor
Theater Theater RETURN LINE:
50
92 m² 58
40 m²
57
44 m²
.............................................................
BOQ OF PIPES
.............................................................
Ø 0.75" = Ø 1.00" = Ø 1.25" =
B Dirty Corridor
56
............................................................. B
46 m² Ø 1.50" = Ø 2.00" = Ø 2.50" =
.............................................................

A A
1 2 3 4 5 6 7

You might also like