S.

NO TYPE OF FINISH THICKNESS PROJECT SPECIFICATION


REFERENCE

1.S20014-0100D-CCH-Vol.2…
1 Travertino Stone Floor Tile Not less than 2.TCNA HANDBOOK FOR
20MM CERAMIC, GLASS, AND STONE
TILE INSTALLATION
1.S20014-0100D-CCH-Vol.2…
Not less than 2.TCNA HANDBOOK FOR
1 Travertino Stone Floor Tile
20MM CERAMIC, GLASS, AND STONE
TILE INSTALLATION
JECT SPECIFICATION SETTING MATERIAL
REFERENCE

Portland Cement Mortar (Thickset) Installation Materials:


ANSI A108.02.
Cleavage Membrane: Asphalt felt, ASTM D 226 or
polythene sheet of thickness 0.1mm.(SECTION 096340 -
STONE FLOORING, PAGE NO.4 OF 11)
Reinforcing Wire Fabric: Galvanized, welded wire fabric,
50.8 by 50.8 mm by 1.57 mm in diameter.(SECTION
096340 - STONE FLOORING, PAGE NO.4 OF 11)
Expanded Metal Lath: Diamond-mesh lath complying with
ASTM C 847(SECTION 096340 - STONE FLOORING, PAGE
NO.4 OF 11)
(Portland Cement: ASTM C 150), TYPE 1
Control Joint filler Neoprene.(SECTION 096340 - STONE
FLOORING, PAGE NO.6 OF 11)

14-0100D-CCH-Vol.2…
NA HANDBOOK FOR
MIC, GLASS, AND STONE
LE INSTALLATION
14-0100D-CCH-Vol.2…
NA HANDBOOK FOR
MIC, GLASS, AND STONE
LE INSTALLATION
SECTION 096340 - S

LAYERS OF INSTALLATION DIRECTLY OVER CONCRETE

A-Apply mortar bed bond coat over concrete of thickness 1.5mm.


B-Placement of reinforcing wire mesh over concrete lapped at joints by atleast
one full mesh
C-Apply mortar bed after applying mortar bed bond coat. Spread, tamp and
screed to uniform thickness at elevations.
D-Placement of stone before setting of mortar. Application of 1.5mm thick
bond coat at the back of stone.
Expansion- and Control-Joint Installation:-Locate and install according to
Drawings and Shop Drawings.(SECTION 096340 - STONE FLOORING, PAGE NO.8
OF 11)
N 096340 - STONE FLOORING

EXPANSION JOINT
Image reference TCNA handbook for ceramic, glass and stone tile installation
(PAGE-434)
SECTIONS AS PER TCNA
Image reference TCNA handbook for ceramic, glass and
stone tile installation (PAGE-312 to 315)
MOVEMENT JOINT
Interior—maximum of 25' in each direction
Interior tilework exposed to direct sunlight (heat) or
moisture—maximum of 12' in each direction
Preferred not less than ¼" nor greater than 3⁄8"
(width/depth
ratio not applied for static joint)

Image reference TCNA handbook for ceramic, glass and


stone tile installation (PAGE-430-436)
NOTES TO BE ADDED TO THE
SHOPDRAWING TITLE BLOCK

1- GROUT MATERIAL AS PER


MANUFACTURER
2-Placement of reinforcing wire
mesh over concrete lapped at
joints by atleast one full mesh
3.If unsanded grout is required,
the grout joint must be 1⁄16" to
1⁄8" wide (nominal).
SECTION 096340 -
S.NO TYPE OF FINISH SIZE

1 STONE TILE 200MMX200MM OR LARGER


SECTION 096340 - STONE FLOORING
STONE TILE INSTALLATION

· Stone laying is need to be done in grid pattern.


· Provision of expansion, contraction and isolation joints where indicated.
· Locate stone tile joint surfaces directly above the concrete joint surfaces and
apply sealant as per refer in section 079200 (joint Sealants).
· Metal edge strips installed at locations indicated.
Urethane Joint Sealant: Multicomponent, nonsag, traffic grade, Class 50 . For
horizontal surfaces mentioned in section 079200 page 13.
NOTES

Installation process complies with the


written instructions of manufacturer.For the
following procedures mentioned in ANSI
A108
SECTION 096340 - STONE FLOORING
S.NO Type of Finish Thickness Height

1 Travertino Stone Base 10MM 100mm


TION 096340 - STONE FLOORING
Installation of Stone Base
Set stones on plaster with epoxy backing on it.
Masking areas near the joint to stop the smearing of adhesive.
Clamps units to ensure the surface alignment of the stone.
Grout Joints after setting.
`
S.NO TYPE OF FINISH INSTALLATION OF STONE ON STAIRS
1 STONE Follow the same detail comply with stone over concrete installation
SECTION 096519 - RESILIENT TILE FLOORING
S.NO TYPE OF FINISH THICKNESS SIZE SEAMING METHOD
1 Solid vinyl floor tile. 3.0MM As in AI Manual As per manufacturer
NG
INSTALLATION OF SOLID VINYL FLOORING
Hydraulic cement based compound as per
manufacturer applied on substrate.
Adhesive for installing tile.
Chemically bonding seam compound.
Floor Polish recommended by
manufacturer.
SECTION 096813 - TILE CARPETING
S.NO TYPE OF FLOOR FINISH INSTALLATION OF CARPET TILE

• Hydraulic cement based compound as per carpet tile


manufacturer.
• Adhesive for installing tile with having VOC content of 50g/L.
1 CARPET TILE • Metal edge strip required to protect the exposed edge of carpet.
(Metal and transition strip of Extruded aluminium with mill finish of
profile mentioned in section tile carpeting page number 5 of 6.
S.NO. TYPE OF FINISH THICKNESS

Factory-mounted
1 unglazed or glazed As indicated in drawings or AI Manual
ceramic mosaic tile.
(IMOS-51)

Unglazed Full-bodied
2 (Porcelain) tile. Not less than 8mm

Glazed or unglazed wall


3 tile Not less than 9mm

Unglazed or glazed
4 ceramic or full-bodied Not less than 8mm
ceramic tile
SECTION 093000
THRESHOLD WATER PROOFING MEMBRANE

· Transition between adjacent floors


· Bevel edges at 1:2 slope with lower
edge of bevel aligned with or up to Recommend by
1.5mm above adjacent floor surface. manufacturer complies
Limit height of threshold to 12.7mm or with ANSI A118.10
less above adjacent floor surface.
SECTION 093000 - TILING
CRACK ISOLATION
MEMBRANE SETTING MATERIALS

· Latex-Portland Cement
Mortar (Thin Set): ANSI
Recommend by A118.4.
manufacturer complies with · Water-Cleanable, Tile-
ANSI A118.10
Setting Epoxy with VOC
content 65g/L or less.
GROUTING TILE INSTALLATION PROCESS

Comply with TCA’s handbook


for Ceramic Tile Installation
(comply with parts of the
styrene-butadiene rubber in liquid-latex ANSI A108
form for addition to prepackaged dry- Joint widths for ceramic tile
grout mix
Water-Cleanable Epoxy Grout: ANSI is 2mm unless otherwise
A118.3, with a VOC content of 65 g/L or indicated and for glazed wall
less. tile it is 2mm unless
otherwise indicated.
Sand-Portland Cement Grout: ANSI Metal edge strip install at
A108.10, consisting of white or gray locations indicated.
cement and white or coloured aggregate Grout sealer to cementitious
as required to produce colour indicated
grout joints in tile floors
according grout sealer
manufacturer.
INTERIOR TILE INSTALLATION PROCESS

Interior Floor Installations, Concrete Subfloor:


Tile Installation F121: Cement mortar bed (thickset) on
waterproof membrane; Follow TCA F121 and ANSI
A108.1A.
b. Grout: Polymer-modified unsanded grout.
wherever a waterproof interior floor is required in
conjunction with ceramic tile installed on a portland
cement mortar bed.
Water Proofing
Sheet Membrane as per ANSI A118.10.
Mortar as per ANSI A108.1A.

Image reference TCNA handbook for ceramic, glass


and stone tile installation.