AlstomGT13E2 225

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GT PRO 23.

0 Admin
Gross Power 225741 kW
Net Power 220319 kW Ambient
Aux. & Losses 5422 kW 1.001 P
LHV Gross Heat Rate 6767 kJ/kWh 35 T
LHV Net Heat Rate 6934 kJ/kWh 60% RH
LHV Gross Electric Eff. 53.2 % 110 p
504 T
LHV Net Electric Eff. 51.92 % 169.6 M
Fuel LHV Input 424339 kWth
Fuel HHV Input 469788 kWth Stop Valve
Net Process Heat 0 kWth 80721 kW

Cold Reheat

24.1 p 0.1126 p
504 T 48.14 T
27.89 p 209.6 M
320 T 250.1 M
167 M

0.1555 M
3.382 p
288.5 T
38.11 M

Hot Reheat
1.001 p
104.9 T
1757.3 M

to HRSG

LP IP HP Natural gas 1.001 p


33.01 M 35 T
424339 kWth LHV 1727 M
LPB IPB HPB 60% RH
3.8 p 27.35 p 115.6 p
141.8 T 228.8 T 321.8 T 0.9913 p
43.14 M 42.61 M 169.6 M 35 T
1727 M
200.7 T 282.5 T 441.4 T
151.8 T 241.8 T 334.8 T

1.026 p
543.6 T
48.65 T 1757.3 M ALSTOM GT13E2
250.3 M
(Physical Model #285)
@ 100% load
145021 kW

GT PRO 23.0 Admin


p [bar] T [C] M [t/h], Steam Properties: IAPWS-IF97
683 11-24-2014 15:01:50 file=C:\TFLOW23\MYFILES\GTPRO.GTP