Refer to Supplemental Information (next page) for complete descriptions of these installation steps
FG-1625/FG-1625T Glassbreak Detector Enable Wall Tamper (FG-1625T only) Mount Detector
Tamper Switch • Remove plastic tab from rear of detector. • Place unit over wall tamper screw, if used!
Mounting Hole
Rear Tamper • Install wall tamper screw as shown. • Use mounting holes as template to mark
Microphone (FG-1625T only) ceiling or wall.
• Set screw depth to make contact w/ bottom of
Wire Entry Hole
Terminal Block tamper cavity when device is installed • Mount detector using appropriate hardware.
Terminal Block
(FG-1625T only)
4.2mm or 4.8mm
1625_005-V0
[#8 or #10]
Wall Mount
(Top View) Connect Detector
Connect detector using 18 to 22 AWG wire, with ends
stripped approximately 6mm (1/4 in.) Use the * 3.5mm (#6) screws
appropriate wiring method as shown in these diagrams: work best with the
screw retention feature.
1625_006-V00
1625_wall_mnt-V0
V+
V- FG-1625T Only
NC TMPR
* The screw retention feature simplifies installation. A rib
EOL EOL in the screw cavity lightly holds the screw in place when
C TMPR installing the detector
NO
FG-1625T Only
Test Detector Installation
1625Wiring_001-V0
Normally Closed Loop/No EOL Resistor Enter Test Mode using FG-701 (see Testing the
Ceiling Mount: (Side View) Detector on the next page) or manually by shorting the
Test Mode pads (as below).
1625_ceiling_mnt-001-V0
V+
Test Location w/ 9V Battery FG-1625T Only
V-
NC TMPR
V+
V EOL EOL
ON
1 2 3 4
C TMPR
9V NO
FG-1625T Only TEST
9V_001-V0
1625_007-V1
1625Wiring_002-V0
V+
ON
SENS1
V- FG-1625T Only
ON
1 2 3 4
SENS2
2
NC TMPR
LATCH
3
is shipped with the cover tamper operational, and the The detector is equipped with two LEDs: a green Event
wall tamper disabled. LED and a red Alarm LED. When the LEDs are
To obtain applicable EU compliance Declaration of Conformities for this product,
enabled, they light in a variety of patterns to convey the
To enable the rear tamper, remove the plastic tab on the please refer to our Website
detector’s operational status. The following table http://www.security.honeywell.com/hsce/international/index.html.
back of the detector, using needle-nose pliers. The wall For any additional information regarding the compliance of this product to any EU
summarizes the LED messages.
tamper arm will then extend through the hole. Proceed specific requirements, please contact –
with the following mounting instructions to install the wall Quality Assurance Department,
Honeywell Security & Custom Electronics,
tamper screw. CONDITION GREEN LED RED LED Newhouse Industrial Estate,
Motherwell,
Normal OFF OFF Lanarkshire ML1 5SB,
7. Mounting the Detector Normal, event detected Flicker OFF Scotland,
United Kingdom
NOTE: If ceiling mounted, the end with the hole Normal, break detected OFF ON 5 seconds Tel: +44(0)1698 738200
(micro-phone end) should face the glass being Email: UK64Sales@Honeywell.com
Normal, alarm latched OFF ON
protected.
Power up ON 1 second ON 1 second
1. If using optional Wall Tamper (FG-1625T):
Mark the mounting location for the wall tamper Low Voltage Flash ON/OFF Flash ON/OFF
screw based on the final location of the Test Mode Flash once per sec OFF NOTICES
detector. Then, install the wall tamper screw so Test Mode, event detected Flicker OFF FCC NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and (2)
that it will just make contact with the bottom of Test Mode, alarm Flash once per sec ON 5 seconds this device must accept any interference received, including interference that may cause
the tamper cavity when the unit is mounted. undesired operation.
Use a flat head 4.2mm or 4.8mm screw (#8 or The user is cautioned that changes or modifications not expressly approved by Honeywell
#10).
11. Cover Screw could void the user’s authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B
2. Position the unit over the wall tamper screw (if The front cover can be secured after installation. To do digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
used), then mark the mounting screw and wire so, remove the cover breakout flash and secure the front reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
openings. If required by the location, install wall cover with a 2.9 mm x 6.0 mm (#4 x ¼ in.) screw. and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
anchors for the mounting screws. particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
3. Secure the unit to the wall or ceiling, oriented so user is encouraged to try to correct the interference by one or more of the following
the microphone has the best line of sight to the measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation
between the equipment and receiver, 3) Connect the equipment into an outlet on a circuit
protected glass. different from that to which the receiver is connected. The installer can also consult an
experienced radio/television technician for additional suggestions, if necessary.
IC Notice: This Class B digital apparatus complies with the Canadian ICES-003.
Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada