Professional Documents
Culture Documents
Operating Manual MPG200 - en
Operating Manual MPG200 - en
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE
2.0 Transport/Installation
2.1 Installation plan .................................................................................... 25
2.2 Technical Specifications ...................................................................... 27
2.3 Incoming goods inspection .................................................................. 27
2.4 Safety instructions for transport ........................................................... 28
2.5 Transport/Storage ................................................................................. 29
2.6 Set up and connection .......................................................................... 29
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE
2.0 Transport/Installation
2.7 Ceiling loads ......................................................................................... 30
2.8 Connection............................................................................................ 30
2.9 Feeding the measuring sensor .............................................................. 31
2.10 Dismantling the measurement device ................................................ 32
3.0 Operation
3.1 Overall layout ....................................................................................... 33
3.2 Safety instructions regarding operation ............................................... 35
3.3 Electrical switch cabinet....................................................................... 36
3.4 Electrical main switch on the switch cabinet ....................................... 36
3.5 Control elements at the switch cabinet ................................................ 37
3.6 Control elements at the measurement device....................................... 39
3.7 Connections on the measurement device ............................................. 40
3.8 Signal lamps on the measurement device............................................. 41
3.9 Prior to commissioning ........................................................................ 42
3.10 Switching on the measurement device ............................................... 43
3.11 Switching off the measurement device .............................................. 43
3.12 Shutting off the measurement device in an emergency ..................... 44
3.13 Selecting the operating mode ............................................................. 45
3.13.1 Selectable waveforms ...................................................................... 47
3.13.2 Selectable measuring frequencies ................................................... 48
3.13.3 Selectable field strength .................................................................. 48
3.13.4 Selectable polarisation .................................................................... 48
3.13.5 DC field measurements ................................................................... 49
3.13.6 Measurement accuracy and reproducibility .................................... 49
3.14 Operational principle of the measurement ......................................... 50
3.15 Block diagram .................................................................................... 52
3.16 Measuring coil systems ...................................................................... 53
3.17 Function description ........................................................................... 54
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE
4.0 Fault
4.1 Safety instructions for troubleshooting ................................................ 58
4.2 Fault report ........................................................................................... 59
4.3 Fault rectification during an emergency stop ....................................... 59
4.4 List of faults.......................................................................................... 60
6.0 Maintenance/repair
(industrial mechanics)
6.1 Safety instructions regarding maintenance and repair ......................... 62
6.2 Maintenance schedule .......................................................................... 63
6.3 Checking the sheet steel infeed ............................................................ 63
7.0 Maintenance/repair
(electricians)
7.1 Safety instructions regarding maintenance and repair ......................... 64
7.2 Maintenance schedule .......................................................................... 66
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE
9.0 Electronics
9.1 Safety instructions for electronics ........................................................ 68
9.2 Circuit diagram with BOM .................................................................. 69
11.0 Instructing
operating and set-up personnel
11.1 Instruction........................................................................................... 72
Inhaltsverzeichnis
Geben Sie die Kapitelüberschrift ein (Stufe 1) ................................................... 1
Geben Sie die Kapitelüberschrift ein (Stufe 2) ............................................................................................... 2
Geben Sie die Kapitelüberschrift ein (Stufe 3) ............................................................................................................ 3
Geben Sie die Kapitelüberschrift ein (Stufe 1) ................................................... 4
Geben Sie die Kapitelüberschrift ein (Stufe 2) ............................................................................................... 5
Geben Sie die Kapitelüberschrift ein (Stufe 3) ............................................................................................................ 6
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 5
1.0 Safety____________________________________
1.1 General
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 7
1.0 Safety____________________________________
1.2 Meaning of symbols
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 8
1.0 Safety____________________________________
1.2 Meaning of symbols
Operating Manual
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 9
1.0 Safety____________________________________
1.2 Meaning of symbols
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 10
1.0 Safety____________________________________
1.3 Risks posed if failing to comply with safety instructions
Failing to follow the safety instructions may result in the voidness of any and all
claims for damages.
In particular, failing to follow the safety instructions may result in the following
risks
:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 11
1.0 Safety____________________________________
1.5 Safety instructions
Safety regulations
1. Never expose the measurement device to water or any other liquids.
Never use the device in a humid or wet environment.
6. Always disconnect the power supply to the measurement device if test and
maintenance tasks are pending.
Precautionary measures
1. The measurement device must only be operated with the prescribed voltage.
2. Repair and maintenance work for the measurement device must only
be carried out by industrial mechanics.
4. All operating and set-up personnel must always wear protective footwear
while starting up and setting up the measurement device.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 12
1.0 Safety____________________________________
1.5 Safety instructions
1. Only use the measurement device for the purpose described in section
"1.6 Intended use".
5. The care and maintenance tasks for the measurement device are described in
detail in the operating manual in sections
5.0 Care (user)
6.0 Maintenance/repair (specialised technical personnel)
7.0 Maintenance/repair (electricians)
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 13
1.0 Safety____________________________________
1.6 Intended use
This measurement device is intended to be used only to determine the magnetic
properties of electrical steel. Based on the measurement tasks, the device can
be operated with different measuring coil systems.
The hardware version of the MPG 200 allows for the simultaneous connection
of up to 12 measuring coil systems.
The sheet metal strips must be used in proper condition only.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 14
1.0 Safety____________________________________
1.6 Intended use
Any other use shall be deemed an inappropriate use of the measurement device.
The user/operating company of the measurement device alone will be liable for
for any damages that may result in this case.
This measurement device must not be operated without the protective safety
equipment in place.
The measurement device has been subjected to a safety and acceptance
inspection.
Due to safety reasons, unauthorised conversions and modifications to the
measurement device are prohibited!
The service, maintenance and repair conditions prescribed in this operating
manual and in the operating instructions of all purchased parts as well in the
product-specific work flow diagram must be strictly observed.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 15
1.0 Safety____________________________________
1.6 Intended use
safety
operation
maintenance, repair and troubleshooting
Adding additional accessories must not affect the emergency stop unit
on the measurement device and take it out of order.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 16
1.0 Safety____________________________________
1.8 Residual risks
Certain residual risks remain while handling the measurement device, even if all
safety instructions are being observed
.
All personnel working at and with this measurement device must be
familiar with these hazards and must adhere to the instructions that
prevent residual risks from resulting in accidents or damage.
life-threatening hazards!
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 17
1.0 Safety____________________________________
1.9 Measurement device workstation
Area 1: The computer unit and monitor with key pad are located at the
measurement device.
Area 1
Area 2: A measurement table with measuring sensors can be added at the side of
the MPG200 switch cabinet in tower version.
Area 2
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 18
1.0 Safety____________________________________
1.10 Authorised persons
The minimum age to operate the device is 16 years.
The responsibilities for the different tasks on the
measurement device must be clearly defined and adhered to.
Unclear competences are a safety risk.
The operating personnel is allowed to operate the measurement device only, if
they have read, understood and signed the operating manual and have also
been instructed to use the MPG200 measurement device accordingly.
Electrician => Personnel with a training as electrician
and who have been instructed to use the
MPG200 measurement device accordingly.
Set-up personnel => Personnel who have been instructed to
carry out configurations in set up mode on the
MPG200 measurement device.
Operating personnel => Personnel who have been instructed to
operate the measurement device accordingly.
Maintenance personnel => Personnel with training as industrial mechanics
and who have been instructed to use the
measurement device accordingly.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 19
1.0 Safety____________________________________
1.12 Operating company
The operating company undertakes to only have personnel work on the MPG200
measurement device who are familiar with the fundamental regulations with
regard to occupational health and safety as well as accident prevention and have
been instructed accordingly on how to handle the measurement device.
Furthermore, the operating company must ensure that all maintenance and
installation work is carried out by maintenance personnel who have
studied the operating manual appropriately and in depth.
The operating company must
• make the operating manual accessible to the operating personnel.
• make sure that the operating personnel and specialised
technicians have read and understood the operating manual and
have them confirm this accordingly with their signature. (Section
1.11)
• instruct the operating personnel, the set-up personnel, the
maintenance personnel and the electricians to work on the
measurement device accordingly and document the instructions
accordingly.
• complete the list of faults in section 4.5 accordingly
and make it accessible to Brockhaus GmbH & Co. KG.
• provide personal protective equipment for operation and
maintenance on the measurement device.
• give additional instructions with regard to residual risks on the
measurement device.
• check at regular intervals the safety-conscious
work of the operating personnel.
• inform the operating personnel about the location and proper
operation of the fire extinguishing equipment.
• check the safety labels on the measurement device for proper
condition at least every two years.
• check the lighting on the measurement device for proper
condition at least every three years.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 20
1.0 Safety____________________________________
1.13 Safety measures implemented at the installation site
The measurement device must be set up on an even and firm ground
on mounting feet to be stable and must be aligned properly with the mounting
feet.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 22
1.0 Safety____________________________________
1.15 Occurring noise levels
The noise level of the measurement device at the workstation was measured
at a distance of 1 m from the measurement device surface and 1.60 m
above the ground.
During the work process, the sound pressure level is
less than 80 dB(A).
1.16 Lighting
The operating company of the measurement device must ensure proper lighting
at the measurement device and must carry out and document a measurement of
the LUX level at the workstation during commissioning.
At insertion workstations, a LUX level of at least 300 is required.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 23
1.0 Safety____________________________________
1.17 Protective safety equipment inspection
General inspections instructions and function tests
Caution must be followed without fed materials.
Inspection intervals
• At the beginning of each shift (interrupted operation)
Caution • Once a week (uninterrupted operation)
• After each maintenance and repair
Inspection content
• Prescribed condition
Caution • Prescribed position
• Secure attachment
• Prescribed function
The following functional tests of the emergency stop switch must be carried out.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 25
2.0 Transport/Installation/Dismantling_________________
2.1 Installation plan
Bild 11: Front view of the MPG200 measurement device, table version
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 26
2.0 Transport/Installation/Dismantling_________________
2.1 Installation plan
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 27
2.0 Transport/Installation/Dismantling_________________
2.2 Technical Specifications
Electrical connected loads
Mains voltage 3x 400 V
Frequency 50 Hz/60Hz
Control voltage 24 VDC
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 28
2.0 Transport/Installation/Dismantling_________________
2.4 Safety instructions for transport
Always make sure that the measurement device is transported impact- and
shock-free.
For the transport to the installation site, only use appropriate, standardised and
tested lifting equipment (fork lift, mobile crane, overhead travelling crane) and
lifting accessories (round slings, lifting straps, chains).
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 29
2.0 Transport/Installation/Dismantling_________________
2.5 Transport/Storage
The measurement device must only be transported with a fork lift or lifting
device on a transport pallet.
Lift here!
Bild 14: Mounting rack
Store the measurement device at a site that is protected from the weather.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 30
2.0 Transport/Installation/Dismantling_________________
2.6 Set up and connection
2.8 Connection
General information:
For safety reasons, no cable glands, connections and equipment should be
loosened while the measurement device is under voltage.
The surrounding area should be cleaned before loosening any screw
connections.
Cable connections:
The cable connections from the power supply to the measurement device must
be laid without kinks and pinched points.
The cables and instruments used must conform with the respective
pressure ratings.
Cleanliness:
Special attention must be paid to cleanliness during all work.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 31
2.0 Transport/Installation/Dismantling_________________
2.9 Feeding the measuring sensor
The measuring sensor is fed with sheet metal strips by the operating personnel.
These metal strips must only be used if they are in proper condition.
(see section 1.6 Intended use)
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 32
2.0 Transport/Installation/Dismantling_________________
2.10 Dismantling the measurement device
For the dismantling of the measurement device, it is important to take into
account the following points.
• Cordon off a wide enough area for the dismantling work.
• Disconnect all sources of voltage from the measurement device.
• Only use load-handling equipment with adequate load capacity.
While dismantling the device, make sure that no substances that contaminate
groundwater such as greases, oil, cleaning agents containing solvents and
similar, infiltrate the ground or reaches the sewage system.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 33
Operation
3.1 Overall layout
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 34
Operation
3.1 Overall layout
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 35
Operation
3.2 Safety instructions regarding operation
Visually check the measurement device for apparent damage and deficiencies at
least once during each shift!
In case of functional faults, the measurement device must be shut off and secured
immediately! Faults must be rectified without delay by specialists who have been
trained to do so.
The start-up and shut down processes as well as control indicators must be
complied with in accordance with the operating manual!
When leaving the measurement device, the operating personnel must make sure
to always switch it off and secure it against restart by unauthorized personnel, if
necessary.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 36
Operation
Have you read and understood the operating manual - in particular
section 1 Protective safety equipment?
The lockable main switch is located at the side of the electrical switch cabinet.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 37
Operation
3.5 Control elements at the switch cabinet
Fuses
Main switch This switch is used to turn on and off the measurement device.
Emergency stop This switch is used to turn off the measurement device in
emergency situations.
F1 Phase monitor
F2 Ground fault interrupter
F3 Transformer T3 – primary side
F4 Transformer T2 – primary side
F7 Amplifier 1 (standard)
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 38
Operation
F8 Amplifier 2 (100kHz amplifier)
F9 NI
F10 Measurement computer & coil switch-over
F11 Flux meter
F12 Service outlet
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 39
Operation
If two amplifiers are used, the following buttons will be located on the left container:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 40
Operation
The following connections are located on the front right side of the measurement
computer:
Generator Output signal of the generator card
B-V Output signal of the measured secondary voltage on the signal
amplifier card
I-V Output signal of the measured current on the signal amplifier
card
H-V Output signal of the measured field coil voltage on the signal
amplifier card
Trigger NI trigger signal
MUX-V Output signal of the multiplexer channel on the signal amplifier
card
Test-IN Test input on the signal amplifier card
Offset Output signal of the offset voltage
Shunt 1 Measured voltage at the resistance sensor 1 (unamplified)
Shunt 2 Measured voltage at the resistance sensor 2 (unamplified)
Field coil Measured voltage at the field coil (unamplified)
S-BO Output signal of the control board
PRI-SPG Measured primary voltage at the output of the primary
buffer amplifier
B-DC Measurement signal for the secondary voltage of the flux meter
Measurements
Test-Buf 1 Test input of the primary buffer amplifier
Test-Buf 2 Test input of the secondary buffer amplifier
B Measured secondary voltage at the output of the secondary
buffer amplifier
Ready LED MPG200 status display
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 41
Operation
The LEDs at the standard power amplifier display the following situations:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 42
Operation
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 43
Operation
3.10 Switching on the measurement device
1. Set the electrical main switch at the electrical switch cabinet to pos. “1”.
2. Unlock the emergency stop switch.
3. Feed the measuring sensor.
4. Press the “ON/OFF” button, if a second power amplifier has been installed.
5. The measuring device is now ready to operate.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 44
Operation
3.12 Shutting off the measurement device in an emergency
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 45
Operation
3.13 Selecting the operating mode
The handling, evaluation and documentation of the measurement values are carried out
with a convenient software package on a Windows computer.
MPG 200 D
Troubleshooting
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 46
Operation
3.13 Selecting the operating mode
The measurement device can be used for the measurement, calculation, determination,
presentation and documentation of the following magnetic properties:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 47
Operation
3.13.1 Selectable waveforms
The waveform of the excitation voltage of the coil system can be selected
freely. The following variants are available to be selected for this purpose:
• Harmonic waves
Additional signals are added to a sinusoidal basic signal the frequency of
which is an integer multiple of the basic signal. This allows to reconvert a
frequency spectrum gained by Fourier decomposition (transformation) into
the relevant signal and to use this signal as exciter signal. As the signals
with integer multiples may demonstrate very high frequencies, a second
amplifier with high band width is also required here.
• Free curves
The values of a period of the signal path are given via a text file. The
values in the text file can be freely selected allowing to display any
imaginable waveform. Using this option also requires the use of a second
amplifier, as a very high filtering slope is also possible here.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 48
Operation
3.13.2 Selectable measuring frequencies
3 Hz to 20 k Hz in increments of 0.1 Hz
For the Epstein frame with 700 coils according to IEC 60404-2 the following
applies:
For other coil systems such as rings and Epstein frames for higher
frequencies, the maximum reachable field strength is lower.
• Setting range 1 mT to 2 T
in increments of 1 mT
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 49
Operation
3.13.5 DC field measurements
Conduct of all measurements with adjustable and constant dϕ/dt
of the secondary signals.
• Maximum field strength 10000 A/m for SST and measuring coils for
punched parts
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 50
Operation
3.14 Operational principle of the measurement
The number of coils and the magnetic length are specified by the geometry of
the measuring coil system.
The required current is provided by a power amplifier. The current
is measured by means of a temperature-stable, low inductance precision
resistor (shunt). As an alternative, the field can also be determined by means
of field coils.
By means of a measurement data collection system, the voltage taken is
digitised directly over an adequate number of interpolation points along the
signal path.
An automatic dynamic adjustment allows for precise voltage measurements
with a digital resolution of 14 bit.
The computer converts the measured voltage into the magnetic field strength
or the measured field of the primary current.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 51
Operation
3.14 Operational principle of the measurement
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 52
Operation
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 53
Operation
3.16 Measuring coil systems
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 54
Operation
3.17 Function description
Production flow
Ablauf 1. Inserting the sheet steel
The operating staff slides the sheet steel to be measured into the sheet
steel infeed of the measurement device.
Inserting the
sheet steel
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 55
Operation
3.17 Function description
Start
button
Measurement process
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 56
Operation
3.17 Function description
Stop
button
Inserting the
sheet steel
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 57
Operation
3.17 Function description
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 58
4.0 Fault_______________________________________
4.1 Safety instructions for troubleshooting
Troubleshooting on the measurement device must be performed
only by industrial mechanics or electricians who have been
instructed accordingly about the hazards posed during
troubleshooting.
If the measurement device has been shut off completely for troubleshooting
activities, it must be secured against accidental restart.
Make sure that screw connections loosened during the troubleshooting work
are always retightened!
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 59
4.0 Fault_______________________________________
4.2 Fault report
• Fault rectification
• Unlock the emergency stop switch.
• Resume the operation of the measurement device.
If there are no more faults indicated, the operation of the measurement device can
be resumed.
In case of repeated faults, do not resume operation of the measurement device,
but have it checked by a specialist (e.g industrial mechanic, electrician) without
delay.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 60
4.0 Fault_______________________________________
4.4 List of faults
Type:________________________ Project no.:__________________
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 61
5.0 Care (user) _____ ________
5.1 Care schedule
• Environmental protection
Cloths soiled with oil must be collected and disposed of in
an environmentally friendly manner.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 62
6.0 Maintenance/repair (industrial mechanics) ____
6.1 Safety instructions regarding maintenance and repair
If the measurement device has been completely shut down during the
maintenance and repair work, it must be secured against accidental restart.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 63
6.0 Maintenance/repair (industrial mechanics) ____
6.2 Maintenance schedule
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 64
7.0 Maintenance/repair (electricians) ____
7.1 Safety instructions regarding maintenance and repair
The operating personnel must be notified about upcoming maintenance and repair
work in advance.
A supervisor must be appointed.
Adhere to all prescribed deadlines or time periods stipulated in the operating
manual for periodic tests/inspections.
A wide enough area for the maintenance and repair work must be cordoned off, if
necessary!
Prior to starting any maintenance work, always
If the measurement device has been completely shut down during the
maintenance and repair work, it must be secured against accidental restart.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 65
7.0 Maintenance/repair (electricians) ____
7.1 Safety instructions regarding maintenance and repair
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 66
7.0 Maintenance/repair (electricians) ____
7.2 Maintenance schedule
All persons involved in the maintenance and repair work on the measurement device
must
• Environmental protection
Electrical components must be disposed of in
an environmentally friendly manner.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 68
9.0 Electronics______________________________________
9.1 Safety instructions for electronics
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 69
9.0 Electronics______________________________________
9.2 Circuit diagram with BOM
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 70
10.0 Spare and wear parts list___________________
10.1 Spare parts order and customer service
We explicitly point out that spare parts or accessories not delivered by us
have not been tested and approved by us.
The installation and/or use of such products may therefore modify or have a
negative impact on structural properties of the measurement device.
The use of spare parts that have not been approved will
nullify the liability for the resulting consequences.
All rights are reserved, also those pertaining to translations, illustrations, modifications and
misunderstandings.
No part of this operating manual may be reproduced or duplicated in any form
(print, photocopy, microfilm or any other medium) nor may it be processed or distributed by means of
electronic systems without the written consent of the Brockhaus Messtechnik GmbH & Co. KG.
.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 71
10.0 Spare and wear parts list___________________
10.2 Wear parts list
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 72
12.0 Instructing operating and set-up personnel______
12.1 Instruction
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 73
12.0 Instructing operating and set-up personnel______
12.1 Instruction
Instructing company / Instructor:
Date, time:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 74
12.0 Instructing operating and set-up personnel______
12.1 Instruction
Instructing company / Instructor:
Date, time:
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 75
13.0 Technical documents______ ___________
13.1 Operating manuals of components
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44