Operating Manual

MPG200 Measurement device

Keep at hand for future reference


when using the measurement device!

Brockhaus GmbH & Co. KG • Gustav-Adolf-Str. 4 • GERMANY-58507 Lüdenscheid


Date of issue: 11/01/2019 Revision index: 04

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE

1.1 General ................................................................................................... 5


1.2 Meaning of symbols ............................................................................... 7
1.3 Risks posed if failing to comply with safety instructions .................... 10
1.4 Personal protective equipment ............................................................. 10
1.5 Safety instructions ................................................................................ 11
• Safety regulations
• Precautionary measures
• General information and measures
• Instructions specific to the measurement device
1.6 Intended use.......................................................................................... 13
1.7 Hazards posed by accessories .............................................................. 15
1.8 Residual risks ....................................................................................... 16
1.9 Measurement device workstation ......................................................... 17
1.10 Authorised persons ............................................................................. 18
1.11 Expert verification (instructing personnel) ....................................... 18
1.12 Operating company ............................................................................ 19
1.13 Safety measures implemented at the installation site ........................ 20
1.14 Protective safety equipment ............................................................... 21
1.15 Occurring noise levels ........................................................................ 22
1.16 Lighting .............................................................................................. 22
1.17 Protective safety equipment inspection.............................................. 22
1.18 Protective safety equipment of the measurement device check-list .. 23
1.19 Preparation of an operating directive ................................................. 24
1.20 Safety expert ....................................................................................... 24
1.21 Unauthorised conversion and spare part manufacture ....................... 24
1.22 Place to store the operating manual ................................................... 24

2.0 Transport/Installation
2.1 Installation plan .................................................................................... 25
2.2 Technical Specifications ...................................................................... 27
2.3 Incoming goods inspection .................................................................. 27
2.4 Safety instructions for transport ........................................................... 28
2.5 Transport/Storage ................................................................................. 29
2.6 Set up and connection .......................................................................... 29

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE

2.0 Transport/Installation
2.7 Ceiling loads ......................................................................................... 30
2.8 Connection............................................................................................ 30
2.9 Feeding the measuring sensor .............................................................. 31
2.10 Dismantling the measurement device ................................................ 32

3.0 Operation
3.1 Overall layout ....................................................................................... 33
3.2 Safety instructions regarding operation ............................................... 35
3.3 Electrical switch cabinet....................................................................... 36
3.4 Electrical main switch on the switch cabinet ....................................... 36
3.5 Control elements at the switch cabinet ................................................ 37
3.6 Control elements at the measurement device....................................... 39
3.7 Connections on the measurement device ............................................. 40
3.8 Signal lamps on the measurement device............................................. 41
3.9 Prior to commissioning ........................................................................ 42
3.10 Switching on the measurement device ............................................... 43
3.11 Switching off the measurement device .............................................. 43
3.12 Shutting off the measurement device in an emergency ..................... 44
3.13 Selecting the operating mode ............................................................. 45
3.13.1 Selectable waveforms ...................................................................... 47
3.13.2 Selectable measuring frequencies ................................................... 48
3.13.3 Selectable field strength .................................................................. 48
3.13.4 Selectable polarisation .................................................................... 48
3.13.5 DC field measurements ................................................................... 49
3.13.6 Measurement accuracy and reproducibility .................................... 49
3.14 Operational principle of the measurement ......................................... 50
3.15 Block diagram .................................................................................... 52
3.16 Measuring coil systems ...................................................................... 53
3.17 Function description ........................................................................... 54

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE

4.0 Fault
4.1 Safety instructions for troubleshooting ................................................ 58
4.2 Fault report ........................................................................................... 59
4.3 Fault rectification during an emergency stop ....................................... 59
4.4 List of faults.......................................................................................... 60

5.0 Care (user)


5.1 Care schedule ....................................................................................... 61
5.2 Cleaning the measurement device ........................................................ 61
5.3 Protective safety equipment ................................................................. 61

6.0 Maintenance/repair
(industrial mechanics)
6.1 Safety instructions regarding maintenance and repair ......................... 62
6.2 Maintenance schedule .......................................................................... 63
6.3 Checking the sheet steel infeed ............................................................ 63

7.0 Maintenance/repair
(electricians)
7.1 Safety instructions regarding maintenance and repair ......................... 64
7.2 Maintenance schedule .......................................................................... 66

8.0 Maintenance/repair (maintenance list)


8.1 List of maintenance work ..................................................................... 67

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
TABLE OF CONTENTS
PAGE

9.0 Electronics
9.1 Safety instructions for electronics ........................................................ 68
9.2 Circuit diagram with BOM .................................................................. 69

10.0 Spare and wear parts list


10.1 Spare parts order and customer service.............................................. 70
10.2 Wear parts list..................................................................................... 71

11.0 Instructing
operating and set-up personnel
11.1 Instruction........................................................................................... 72

12.0 Technical documents


12.1 Operating manuals of components ..................................................... 75

Inhaltsverzeichnis
Geben Sie die Kapitelüberschrift ein (Stufe 1) ................................................... 1
Geben Sie die Kapitelüberschrift ein (Stufe 2) ............................................................................................... 2
Geben Sie die Kapitelüberschrift ein (Stufe 3) ............................................................................................................ 3
Geben Sie die Kapitelüberschrift ein (Stufe 1) ................................................... 4
Geben Sie die Kapitelüberschrift ein (Stufe 2) ............................................................................................... 5
Geben Sie die Kapitelüberschrift ein (Stufe 3) ............................................................................................................ 6

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 5
1.0 Safety____________________________________
1.1 General

This operating manual contains fundamental instructions to be observed during


installation, operation and maintenance It is therefore essential that these
instructions are read by the operating personnel, industrial mechanics,
electricians and set-up personnel prior to commissioning
.
The measurement device has been subjected to a safety and acceptance
inspection.
However, the operation of the device can endanger the user or
third parties and cause damage to the equipment or other assets
if:

operated by personnel who have not been trained or instructed


accordingly to do so.
used for purposes other than the intended purpose.
failing to maintain and repair the device properly.

Operator errors or misuse present hazards for

the operator (risk of sustaining injuries)


the measurement device and other property of the operating
company
the efficient operation of the measurement device
In addition to the general safety instructions contained in the “Safety” section,
all other specific safety instructions included in the other sections and product-specific
operating instructions must be observed
.
The operating manual must be available at the application site of the
measurement device at all times.

All persons involved in the set up, commissioning, operation,


maintenance and repair of the measurement device, must

• closely follow this operating manual and all product-specific


operating instructions.
It is your safety that is at stake here!
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 6
1.0 Safety____________________________________

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 7
1.0 Safety____________________________________
1.2 Meaning of symbols

Safety instructions in this operating manual,


the non-compliance of which may result in
hazards to the personnel, are marked accordingly
with the general hazard symbol.

In the operating manual, electrical hazards are marked


accordingly with the hazard symbol displayed here.

Caution - risk of sustaining injuries on the hands

Wear protective footwear

Wear protective gloves

Use mounting racks

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 8
1.0 Safety____________________________________
1.2 Meaning of symbols

While carrying out maintenance and repair work, always


attach the “Do not switch on” warning sign.

Operating Manual

This symbol can be found in safety instructions,


Caution the non-compliance of which may result in hazards to the
measurement device
and its functions.

Tips and information can be found here


Note that facilitate and ensure a safe operation
.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 9
1.0 Safety____________________________________
1.2 Meaning of symbols

Electrical switch cabinets

Bild 1: Electrical switch cabinet MPG200, tower version

Bild 2: Electrical switch cabinet MPG 200, table version

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 10
1.0 Safety____________________________________
1.3 Risks posed if failing to comply with safety instructions
Failing to follow the safety instructions may result in the voidness of any and all
claims for damages.
In particular, failing to follow the safety instructions may result in the following
risks
:

• Failure of important functions of the measurement device


• Hazards to the personnel posed by electrical effects.

1.4 Personal protective equipment


Configuration work, commissioning and operation of the measurement device
must be carried out only with the prescribed personal protective equipment
.

Protective footwear must be


worn at all times while working
on the measurement device.

Always wear protective gloves


while handling steel plates.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 11
1.0 Safety____________________________________
1.5 Safety instructions

Safety regulations
1. Never expose the measurement device to water or any other liquids.
Never use the device in a humid or wet environment.

2. Never use the device near flammable liquids or gases.

3. Avoid damage to cables.

4. Protect the electrical cables from sharp edges, oil or heat.

5. If the measurement device is not used, disconnect it from


the power supply.
Set the main switch on the measurement device to "0" position.

6. Always disconnect the power supply to the measurement device if test and
maintenance tasks are pending.

7. Do not remove the attached protective cover and screws.

Precautionary measures
1. The measurement device must only be operated with the prescribed voltage.

2. Repair and maintenance work for the measurement device must only
be carried out by industrial mechanics.

3. The configuration work must be carried out by set-up personnel only.

4. All operating and set-up personnel must always wear protective footwear
while starting up and setting up the measurement device.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 12
1.0 Safety____________________________________
1.5 Safety instructions

General information and measures

1. Only use the measurement device for the purpose described in section
"1.6 Intended use".

2. Never work with a damaged measurement device.


Have the measurement device checked out for faults immediately, and
have it repaired and maintained by industrial mechanics only.

3. Store the measurement device in a clean and dry location only.

Instructions specific to the measurement device

1. This measurement device is intended to be used to measure sheet metal strips


and plates only.

2. The safety instructions must be adhered to in any case.

3. It is essential to read the operating manual prior to assembling or


disassembling the measurement device .

4. The proper configuration of the measurement device is described in detail in


the operating manual in section "3.0 Operation".

5. The care and maintenance tasks for the measurement device are described in
detail in the operating manual in sections
5.0 Care (user)
6.0 Maintenance/repair (specialised technical personnel)
7.0 Maintenance/repair (electricians)

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 13
1.0 Safety____________________________________
1.6 Intended use
This measurement device is intended to be used only to determine the magnetic
properties of electrical steel. Based on the measurement tasks, the device can
be operated with different measuring coil systems.
The hardware version of the MPG 200 allows for the simultaneous connection
of up to 12 measuring coil systems.
The sheet metal strips must be used in proper condition only.

Bild 3: Epstein700 measuring sensor

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 14
1.0 Safety____________________________________
1.6 Intended use
Any other use shall be deemed an inappropriate use of the measurement device.
The user/operating company of the measurement device alone will be liable for
for any damages that may result in this case.

The same applies to unauthorised modifications and manipulations


of protective safety equipment of the measurement device.

This measurement device must not be operated without the protective safety
equipment in place.
The measurement device has been subjected to a safety and acceptance
inspection.
Due to safety reasons, unauthorised conversions and modifications to the
measurement device are prohibited!
The service, maintenance and repair conditions prescribed in this operating
manual and in the operating instructions of all purchased parts as well in the
product-specific work flow diagram must be strictly observed.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 15
1.0 Safety____________________________________
1.6 Intended use

Intended use also includes the adherence to all instructions regarding

safety
operation
maintenance, repair and troubleshooting

this operating manual and in the product-specific operating instructions.

Bild 4: MPG 200 measurement device

Voltage Length Width Height Power


400 V 2000mm 800mm 780mm 5.2 kVA

1.7 Hazards posed by accessories

Adding additional accessories must not affect the emergency stop unit
on the measurement device and take it out of order.

The EMERGENCY STOP switch must be freely accessible.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 16
1.0 Safety____________________________________
1.8 Residual risks

Certain residual risks remain while handling the measurement device, even if all
safety instructions are being observed
.
All personnel working at and with this measurement device must be
familiar with these hazards and must adhere to the instructions that
prevent residual risks from resulting in accidents or damage.

Prior to maintenance or cleaning work, the voltage supply of the


measurement device must be disconnected and locked.

Never remove any safety equipment or put it out of order


by making modifications to the measurement device.

During operation, keep the switch cabinet


closed at all times.
The voltage applied poses

life-threatening hazards!

Bild 5: Electrical switch cabinet

While inserting and removing the sheet metal strips,


be aware that edges may be sharp.
Wear protective gloves!

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 17
1.0 Safety____________________________________
1.9 Measurement device workstation
Area 1: The computer unit and monitor with key pad are located at the
measurement device.

Area 1

Bild 6: MPG 200 measurement device, table version

Area 2: A measurement table with measuring sensors can be added at the side of
the MPG200 switch cabinet in tower version.

Area 2

Bild 7: MPG200 measurement device, tower version

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 18
1.0 Safety____________________________________
1.10 Authorised persons
The minimum age to operate the device is 16 years.
The responsibilities for the different tasks on the
measurement device must be clearly defined and adhered to.
Unclear competences are a safety risk.
The operating personnel is allowed to operate the measurement device only, if
they have read, understood and signed the operating manual and have also
been instructed to use the MPG200 measurement device accordingly.
Electrician => Personnel with a training as electrician
and who have been instructed to use the
MPG200 measurement device accordingly.
Set-up personnel => Personnel who have been instructed to
carry out configurations in set up mode on the
MPG200 measurement device.
Operating personnel => Personnel who have been instructed to
operate the measurement device accordingly.
Maintenance personnel => Personnel with training as industrial mechanics
and who have been instructed to use the
measurement device accordingly.

Personnel to be trained, taught and instructed, or personnel who are currently


in the process of receiving training must work on the measurement device
only under the constant supervision of an experienced expert.

1.11 Expert verification (instructing personnel)


The expert herewith verifies with his/her signature to be familiar with the
fundamental regulations of occupational health and safety and accident protection
and that he/she has been instructed accordingly in the handling of the
measurement device and has read and understood the operating manual prior
starting with the work.
Date:__________ (Signature):___________
Date:__________ (Signature):___________
Date:__________ (Signature):___________
Date:__________ (Signature):___________
Date:__________ (Signature):___________

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 19
1.0 Safety____________________________________
1.12 Operating company
The operating company undertakes to only have personnel work on the MPG200
measurement device who are familiar with the fundamental regulations with
regard to occupational health and safety as well as accident prevention and have
been instructed accordingly on how to handle the measurement device.
Furthermore, the operating company must ensure that all maintenance and
installation work is carried out by maintenance personnel who have
studied the operating manual appropriately and in depth.
The operating company must
• make the operating manual accessible to the operating personnel.
• make sure that the operating personnel and specialised
technicians have read and understood the operating manual and
have them confirm this accordingly with their signature. (Section
1.11)
• instruct the operating personnel, the set-up personnel, the
maintenance personnel and the electricians to work on the
measurement device accordingly and document the instructions
accordingly.
• complete the list of faults in section 4.5 accordingly
and make it accessible to Brockhaus GmbH & Co. KG.
• provide personal protective equipment for operation and
maintenance on the measurement device.
• give additional instructions with regard to residual risks on the
measurement device.
• check at regular intervals the safety-conscious
work of the operating personnel.
• inform the operating personnel about the location and proper
operation of the fire extinguishing equipment.
• check the safety labels on the measurement device for proper
condition at least every two years.
• check the lighting on the measurement device for proper
condition at least every three years.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 20
1.0 Safety____________________________________
1.13 Safety measures implemented at the installation site
The measurement device must be set up on an even and firm ground
on mounting feet to be stable and must be aligned properly with the mounting
feet.

Bild 8: MPG 200 measurement device

Bild 9: Mounting feet on the measurement device

A tipping measurement device results in the risk of sustaining injuries!

Ensure - with appropriate internal instructions


Note and checks - that the environment of the
workstation is clean and neat at all times.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 21
1.0 Safety____________________________________
1.14 Protective safety equipment

The entire measurement device is shut down by


• pressing the EMERGENCY STOP button

Protective safety equipment


• has been installed for the safety of the operating personnel.
• must under no circumstances be changed, removed or
bypassed with modifications on the measurement device.

Bild 10: Safety equipment on the measurement device

Emergency stop button

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 22
1.0 Safety____________________________________
1.15 Occurring noise levels
The noise level of the measurement device at the workstation was measured
at a distance of 1 m from the measurement device surface and 1.60 m
above the ground.
During the work process, the sound pressure level is
less than 80 dB(A).

1.16 Lighting
The operating company of the measurement device must ensure proper lighting
at the measurement device and must carry out and document a measurement of
the LUX level at the workstation during commissioning.
At insertion workstations, a LUX level of at least 300 is required.

In addition, the operating company must


• check the lighting equipment
of the measurement device for proper condition
at least every three years.

1.17 Protective safety equipment inspection


After each repair and maintenance work, please use the check-list to inspect the
protective safety equipment: 1.18 Protective safety equipment check-list
Prior to each start-up of the measurement device, all protective safety equipment
must be installed and functioning properly.
Protective safety equipment must only be removed
• after shut down
• Securing against accidental start-up of the measurement device.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 23
1.0 Safety____________________________________
1.17 Protective safety equipment inspection
General inspections instructions and function tests
Caution must be followed without fed materials.

Ensure immediate rectification of detected deficiencies


on the protective safety equipment!

Inspection intervals
• At the beginning of each shift (interrupted operation)
Caution • Once a week (uninterrupted operation)
• After each maintenance and repair

Inspection content
• Prescribed condition
Caution • Prescribed position
• Secure attachment
• Prescribed function

1.18 Protective safety equipment of the measurement device check-list


General inspection
Installed and screwed on tightly
Protective cover
Switch and signal lights Installed and intact
Emergency stop button Installed and intact
Power cable Installed and intact

The following functional tests of the emergency stop switch must be carried out.

Measurement device ready to operate


Emergency stop button activated
Work flow no function

5x work flows no fault

Inspection date:__________ Inspector (signature):___________


Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 24
1.0 Safety____________________________________

1.19 Preparation of an operating directive


The operating company of the measurement device must ensure the preparation
of an operating directive on the basis of the operating manual.
This operating directive must be hang up at all existing
workstation and must be complied with by all operating personnel.
For the preparation of the operating directive, it is important to adhere
to the occupational health and safety instructions included in section 1.0 of this
operating manual.

1.20 Safety expert


Prior to commissioning, the measurement device must undergo a safety-related
test carried out by a safety expert which must be documented accordingly.
The measurement device must only be used within the production process
after the test report has been prepared and the device has been released by the
safety expert.

1.21 Unauthorised conversion and spare part manufacture


Conversions or modifications to the measurement device are only allowed upon
consultation with the manufacturer. Brockhaus GmbH & Co. KG is the
manufacturer of the device. Original spare parts and accessories authorised by the
manufacturer serve to enhance safety. The use of any other parts will invalidate
any liability of the manufacturer for consequential damage.

1.22 Place to store the operating manual


The operating manual must be accessible at the measurement device
at all times.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 25
2.0 Transport/Installation/Dismantling_________________
2.1 Installation plan

Bild 11: Front view of the MPG200 measurement device, table version

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 26
2.0 Transport/Installation/Dismantling_________________
2.1 Installation plan

Bild 12: MPG200 electrical switch cabinet, tower version

Bild 13: Epstein 700 measuring sensor

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 27
2.0 Transport/Installation/Dismantling_________________
2.2 Technical Specifications
Electrical connected loads
Mains voltage 3x 400 V
Frequency 50 Hz/60Hz
Control voltage 24 VDC

Specifications of the measurement device


MPG 200 table version
dimensions width x depth x 2000mm x 800mm x 780mm
height
MPG 200 tower version
600mm x 800mm x 1950mm
dimensions width x depth x
Depth with base 900mm
height

2.3 Incoming goods inspection


Check the packaging for apparent damage.
If the measurement device has been delivered with no apparent damage to the
packaging, however, with damage that was covered, contact Brockhaus GmbH
& Co. KG without delay and document the damage. (photos)

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 28
2.0 Transport/Installation/Dismantling_________________
2.4 Safety instructions for transport

Always wear a protective helmet, protective footwear and


protective gloves while working!

Only use appropriate and tested lifting equipment!

Only use appropriate lifting accessories such as ropes or lifting straps!


For the selection of lifting equipment and accessories, always comply with
the maximum loads!

Never walk or stand under suspended loads!

Always make sure that the measurement device is transported impact- and
shock-free.

For the transport to the installation site, only use appropriate, standardised and
tested lifting equipment (fork lift, mobile crane, overhead travelling crane) and
lifting accessories (round slings, lifting straps, chains).

The measurement device must only be lifted with a transport


Caution pallet. (see section 2.5)

For dimensions and weights, please refer to the technical specifications


(see section 2.3)

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 29
2.0 Transport/Installation/Dismantling_________________
2.5 Transport/Storage
The measurement device must only be transported with a fork lift or lifting
device on a transport pallet.

Lift here!
Bild 14: Mounting rack

Store the measurement device at a site that is protected from the weather.

2.6 Set up and connection


The measurement device must be set up on an even and firm ground
on mounting feet to be stable and must be aligned properly with the mounting
feet.

Bild 15: Mounting feet at the SST 500x500 measuring sensor

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 30
2.0 Transport/Installation/Dismantling_________________
2.6 Set up and connection

The permanent connection of the operating network must be carried out by an


electrician and in accordance with applicable regulations at a shut off
measurement device only.
The main switch must be set to “0” position before the measurement
device is connected to the power supply.
Before connecting the measurement device to the power supply,
conformity with the mains voltage and frequency must be ensured.
(Rating plate)
Prior to commissioning the measurement device, all clamps must be checked for
a tight fit by an electrician.
Vibrations during transport sometimes cause the connections at the
measurement device to loosen. Potentially loose contacts
may lead to functional faults which are often hard to locate.

2.7 Ceiling loads


The ceiling loads at the installation site must be observed.

2.8 Connection
General information:
For safety reasons, no cable glands, connections and equipment should be
loosened while the measurement device is under voltage.
The surrounding area should be cleaned before loosening any screw
connections.
Cable connections:
The cable connections from the power supply to the measurement device must
be laid without kinks and pinched points.
The cables and instruments used must conform with the respective
pressure ratings.

Cleanliness:
Special attention must be paid to cleanliness during all work.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 31
2.0 Transport/Installation/Dismantling_________________
2.9 Feeding the measuring sensor
The measuring sensor is fed with sheet metal strips by the operating personnel.
These metal strips must only be used if they are in proper condition.
(see section 1.6 Intended use)

Bild 16: Epstein 700 measuring sensor

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 32
2.0 Transport/Installation/Dismantling_________________
2.10 Dismantling the measurement device
For the dismantling of the measurement device, it is important to take into
account the following points.
• Cordon off a wide enough area for the dismantling work.
• Disconnect all sources of voltage from the measurement device.
• Only use load-handling equipment with adequate load capacity.

All persons involved in the dismantling of the measurement device must

• be familiar with the fundamental regulations regarding


occupational health and safety and accident prevention.

While dismantling the device, make sure that no substances that contaminate
groundwater such as greases, oil, cleaning agents containing solvents and
similar, infiltrate the ground or reaches the sewage system.

These substances must be collected, stored, transported and disposed of in


adequate tanks and containers.

Local regulations regarding the protection of the environment


and occupational health and safety as well as instructions by the
lubricant manufacturer regulate the handling and use of
lubricants. These regulations must be observed.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 33
Operation
3.1 Overall layout

MPG200 measurement device, table version

scales monitor/screen measuring sensor

main switch electrical switch cabinet measurement


computer

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 34
Operation
3.1 Overall layout

MPG200 measurement device, tower version

Main switch Electrical switch cabinet

Epstein 700 measuring sensor

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 35
Operation
3.2 Safety instructions regarding operation

Only use the measurement device in technically perfect condition and


in accordance with its intended use, in a safety-conscious and hazard-conscious
manner and in compliance with this operating manual.

Start up the measuring device only in assembled and ready-to-operate condition.

Only operate the measurement device if all protective safety equipment is


(see chapter 1.14) in place and fully operational!

All stipulated personal protective equipment must be used during operation.

Visually check the measurement device for apparent damage and deficiencies at
least once during each shift!

Report any changes (including changes in the


operating behaviour) to the competent authority or person without delay!
If necessary, shut off and secure the measurement device promptly.

In case of functional faults, the measurement device must be shut off and secured
immediately! Faults must be rectified without delay by specialists who have been
trained to do so.

The start-up and shut down processes as well as control indicators must be
complied with in accordance with the operating manual!

When leaving the measurement device, the operating personnel must make sure
to always switch it off and secure it against restart by unauthorized personnel, if
necessary.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 36
Operation
Have you read and understood the operating manual - in particular
section 1 Protective safety equipment?

You may not use the measurement equipment prior to that!

3.3 Electrical switch cabinet


The electrical switch cabinet is located on the left side of the measurement
device, or it is a separate switch cabinet.

Bild 17: Electrical switch cabinet

3.4 Electrical main switch on the switch cabinet

The lockable main switch is located at the side of the electrical switch cabinet.

Bild 18: Main switch on the electrical switch cabinet

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 37
Operation
3.5 Control elements at the switch cabinet

Main switch Emergency stop

Fuses

Main switch This switch is used to turn on and off the measurement device.

Emergency stop This switch is used to turn off the measurement device in
emergency situations.

Fuses Fuses F1 to F10 protect the following components


from over current:

F1 Phase monitor
F2 Ground fault interrupter
F3 Transformer T3 – primary side
F4 Transformer T2 – primary side
F7 Amplifier 1 (standard)
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 38
Operation
F8 Amplifier 2 (100kHz amplifier)
F9 NI
F10 Measurement computer & coil switch-over
F11 Flux meter
F12 Service outlet

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 39
Operation

3.6 Control elements at the measurement device

Bild 19: Button on the measurement device

If two amplifiers are used, the following buttons will be located on the left container:

Start Manual start-up of the amplifier


Stop Manual stop of the amplifier
Reset Reset and default values
Power ON Mains switch to turn on the amplifier

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 40
Operation

3.7 Connections on the measurement device

Bild 20: Connections on the measurement device

The following connections are located on the front right side of the measurement
computer:
Generator Output signal of the generator card
B-V Output signal of the measured secondary voltage on the signal
amplifier card
I-V Output signal of the measured current on the signal amplifier
card
H-V Output signal of the measured field coil voltage on the signal
amplifier card
Trigger NI trigger signal
MUX-V Output signal of the multiplexer channel on the signal amplifier
card
Test-IN Test input on the signal amplifier card
Offset Output signal of the offset voltage
Shunt 1 Measured voltage at the resistance sensor 1 (unamplified)
Shunt 2 Measured voltage at the resistance sensor 2 (unamplified)
Field coil Measured voltage at the field coil (unamplified)
S-BO Output signal of the control board
PRI-SPG Measured primary voltage at the output of the primary
buffer amplifier
B-DC Measurement signal for the secondary voltage of the flux meter
Measurements
Test-Buf 1 Test input of the primary buffer amplifier
Test-Buf 2 Test input of the secondary buffer amplifier
B Measured secondary voltage at the output of the secondary
buffer amplifier
Ready LED MPG200 status display

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 41
Operation

3.8 Signal lamps on the measurement device

Bild 21: LEDs at the power amplifier

The LEDs at the standard power amplifier display the following situations:

Mains Operating state


PWR INT Internal supply voltage
PWR EXT External supply voltage
OVER Temp Temperature exceeded
Temp Fault Temperature fault
SOA Fault SOA protective circuit
U-Max Maximum voltage exceeded
I-Max Maximum current exceeded
I-Limit Current limit exceeded

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 42
Operation

3.8 Signal lamps at the SST500 measuring sensor

Start button Stop button

Bild 22: Start/ Stop button at the SST500

The lamps indicate the following situations:

• Start signal lamp


Lights up green: Measurement process has started

• Stop signal lamp


Lights up green: Measurement process has been
completed

3.9 Prior to commissioning

Prior to commissioning, check whether the values on the rating plate


are identical to the connected loads at the measurement device.
The measurement device must be installed, aligned and connected properly.
• Get the measurement device ready to operate and feed the measuring
sensor.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 43
Operation
3.10 Switching on the measurement device

Bild 23: Electrical main switch Bild 24: ON/OFF button

1. Set the electrical main switch at the electrical switch cabinet to pos. “1”.
2. Unlock the emergency stop switch.
3. Feed the measuring sensor.
4. Press the “ON/OFF” button, if a second power amplifier has been installed.
5. The measuring device is now ready to operate.

3.11 Switching off the measurement device


1. The measuring device is ready to operate.
2. Set the electrical main switch at the electrical switch cabinet to “0” pos.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 44
Operation
3.12 Shutting off the measurement device in an emergency

• Activate the EMERGENCY STOP button

Bild 25: EMERGENCY STOP button at the measurement device

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 45
Operation
3.13 Selecting the operating mode

Bild 26: Operating the measurement device

The handling, evaluation and documentation of the measurement values are carried out
with a convenient software package on a Windows computer.

The operation of the software is described in details in the following manual:

MPG 200 - User manual


User manual for the operation of the MPG 200 D software

The following document describes in detail how to handle any problems:

MPG 200 D
Troubleshooting

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 46
Operation
3.13 Selecting the operating mode

The measurement device can be used for the measurement, calculation, determination,
presentation and documentation of the following magnetic properties:

• Specific magnetic hysteresis loss (W/kg)


• Peak value of the polarisation (T)
• Effective polarisation (T)
• Peak value of magnetic field intensity (A/m)
• Effective magnetic field intensity (A/m)
• Remanence (T)
• Coercitive field strength (A/m)
• AC Amplitude permeability
• Specific apparent power (VA/kg)
• AC/DC hysteresis loops
• Inductance (mH)
• Peak value of induction (T)
• Energy amount (mJ/kg)
• Peak value of permeability
• Differential permeability

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 47
Operation
3.13.1 Selectable waveforms
The waveform of the excitation voltage of the coil system can be selected
freely. The following variants are available to be selected for this purpose:

• Sinusoidal secondary voltage control:


The secondary signal of the coil system is kept sinusoidal by means of a
control circuit. This complies with the specifications included in the IEC
60404-2 standard regarding the Epstein measurement.

• Sinusoidal input voltage with DC component (optional)


Any DC component can be added to the sinusoidal input voltage. The
secondary voltage control is not sinusoidal

• Pulse width modulation (optional)


The exciter signal consists of unipolar or bipolar pulses with different
switch on/switch off time. This corresponds to the control of asynchronous
motors often used in practice via frequency converter with pulse width
modulation. For this option, a second amplifier is required with high
bandwidth as the signals demonstrate a very high filtering slope

• Harmonic waves
Additional signals are added to a sinusoidal basic signal the frequency of
which is an integer multiple of the basic signal. This allows to reconvert a
frequency spectrum gained by Fourier decomposition (transformation) into
the relevant signal and to use this signal as exciter signal. As the signals
with integer multiples may demonstrate very high frequencies, a second
amplifier with high band width is also required here.

• Free curves
The values of a period of the signal path are given via a text file. The
values in the text file can be freely selected allowing to display any
imaginable waveform. Using this option also requires the use of a second
amplifier, as a very high filtering slope is also possible here.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 48
Operation
3.13.2 Selectable measuring frequencies
3 Hz to 20 k Hz in increments of 0.1 Hz

3.13.3 Selectable field strength


The maximum field strength to be reached depends on the number of
windings and the magnetic length of the coil system. For SST coils and
measuring coils for punched parts, the following standard range applies:

• Maximum field strength 10000 A/m


• Setting range 2 A/m to 10000 A/m

For the Epstein frame with 700 coils according to IEC 60404-2 the following
applies:

• Maximum field strength 30000 A/m


• Setting range 2 A/m to 30000 A/m

For other coil systems such as rings and Epstein frames for higher
frequencies, the maximum reachable field strength is lower.

3.13.4 Selectable polarisation


Note that the maximum reachable polarisation is applicable for the standard
electrical steel and dependent on the selected maximum field strength of the
device as well as the cross-sectional area and permeability of the sample.

• Setting range 1 mT to 2 T
in increments of 1 mT

• Setting tolerance better 0.1 %

The absolute setting tolerance of the polarisation depends on the accuracy of


the dimensions and determined lengths of the sample.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 49
Operation
3.13.5 DC field measurements
Conduct of all measurements with adjustable and constant dϕ/dt
of the secondary signals.

Determination of the DC hysteresis, commutation, initial (magnetisation)


curve and hysteresis loss.

• Maximum field strength 10000 A/m for SST and measuring coils for
punched parts

• Maximum field strength 30000 A/m for Epstein 700

3.13.6 Measurement accuracy and reproducibility

• The measurement accuracy of the measurement device is better than 1.5%,


based on Epstein samples certified by the Federal Institute of Physics and
Metrology (PTTB).

• The measurement accuracy of the measurement device is better than 2%,


based on SST samples certified by the Federal Institute of Physics and
Metrology (PTTB).

• The reproducibility of the measurement device is better than 0.2%.

• The system accuracy is better than 0.2%.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 50
Operation
3.14 Operational principle of the measurement

For the measurement of the magnetic properties of electrical steel, a material


sample must be prepared and be exposed in an appropriate coil system to a
specific magnetic field.
The measuring coil system consists of a primary winding generating a
magnetic field which then generates the magnetic flux in the sheet steel.
The magnetic field is determined by the current, the winding and the number
of coils, as well as the magnetic length of the coil.

The number of coils and the magnetic length are specified by the geometry of
the measuring coil system.
The required current is provided by a power amplifier. The current
is measured by means of a temperature-stable, low inductance precision
resistor (shunt). As an alternative, the field can also be determined by means
of field coils.
By means of a measurement data collection system, the voltage taken is
digitised directly over an adequate number of interpolation points along the
signal path.
An automatic dynamic adjustment allows for precise voltage measurements
with a digital resolution of 14 bit.
The computer converts the measured voltage into the magnetic field strength
or the measured field of the primary current.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 51
Operation
3.14 Operational principle of the measurement

The magnetic flux or the polarisation is measured with another measurement


data acquisition system.
The polarisation is determined by the measurement of the voltage induced in
the secondary winding of the coil system and the voltage decoupled via a high
voltage impedance converter.

The secondary voltage is also digitised with automatic dynamic adjustment.


The conversion and integration are performed by the PC.
The parallel acquisition of the two parameters H and B
by two independent recording and acquisition systems ensures absolutely
simultaneous measurement. In this way, measurement errors caused by phase
differences are avoided.
The PC calculates all above-mentioned values from the differentiated and
integrated measurement parameters. Sources of error such as analogue
multipliers and integrators are not available.
The high level of reproducibility and the drift-free long-term stability are
ensured in this way.
Measurements according to or following the EC 60404-2 or IEC 60404-3
standards require a sinusoidal polarisation process. Hence, the secondary
voltage must also be sinusoidal.
However, the measuring coil system does not represent any linear
transmission element. Hence, a control circuit for the primary signal has to
force the shape of the secondary signal.
The control algorithm tests the secondary voltage for its waveform and
controls the power amplifier in such a way that the secondary voltage is
sinusoidal.
The control parameters are adjusted by the PC according to the coil system
and sample properties.
The target voltage is generated by a highly stable, quartz-controlled digital
signal generator.
This allows to reach a very high level of frequency and amplitude stability,
which is crucial for the achievement of such high level of setting accuracy
and precise measurements by BROCKHAUS measurement devices.
Amplitude and frequency are adjusted by the PC according to the sample data
entered via the user software (weight, density, required frequency, target
polarisation, etc.).

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 52
Operation

3.15 Block diagram

The figure shows the measurement configuration in principle.


The excitation circuit is controlled by a regulated voltage, whose waveform,
frequency and amplitude are specified by the computer.
The power amplifier feeds the primary winding of the measuring coil system.
The magnetising current is measured as voltage drop via a precision resistor
or a field coil. The corresponding output is connected to the I or H input of
the measurement device.
The voltage induced in the secondary winding of the coil system is decoupled
from the coils system via the high voltage impedance converter and then led
to the B input of the measurement data acquisition system.
The computer takes over control of the signal generator, the adjustment of the
control parameters and the compensation of the DC component on the
primary side, the settings for the processing of measurement signals as well as
the conversion of the digitised analogue measurement parameters into the
relevant physical parameters.
Operator navigation is programme-controlled.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 53
Operation
3.16 Measuring coil systems

All of the following measuring coil systems can be operated on the


BROCKHAUS electrical sheet measurement devices.

The specifications of the measurement coils systems are enclosed as


Annex.

These consist, in particular, of the following:

• Epstein frames for frequencies of 50 Hz/60 Hz


according to IEC standard no. 404-2
for a sample weight of 1 kg
for a sample weight of 0.5 kg

• Epstein frames for frequencies of 400 Hz


for a sample weight of 1 kg
for a sample weight of 0.5 kg

• Measuring coil type for


punched parts, cuts and strips

• Single strip measuring coil for Epstein strips


(30 x 280 mm)

• Single sheet measuring coil


according to IEC standard no. 404-3 (500 x 500 mm)

• Terminal box for primary and secondary windings


Module for rings, transformer cores and stators

• Custom-made special single sheet and single strip measuring


coils for other material dimensions

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 54
Operation
3.17 Function description

Production flow
Ablauf 1. Inserting the sheet steel
The operating staff slides the sheet steel to be measured into the sheet
steel infeed of the measurement device.

Inserting the
sheet steel

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 55
Operation
3.17 Function description

Ablauf 2. Start enable


Then, the operating staff activates the start button on the control panel
to start the measurement process. The measurement yoke closes.

Start
button

Ablauf 3. Measurement process


On the PC, the measurement process can now be controlled by means of
the software.

Measurement process

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 56
Operation
3.17 Function description

Ablauf 4. Completing the measurement process


The operator presses the stop button on the control panel
to complete the measurement process. The measurement yoke opens.

Stop
button

Ablauf 5. Removing the sheet steel


Finally, the operating personnel removes the sheet steel again.

Inserting the
sheet steel

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 57
Operation
3.17 Function description

The programme is configured by the manufacturer.


Users are not allowed to change the configurations.
Caution Please contact Brockhaus GmbH & Co. KG GmbH if
you require a different workflow.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 58
4.0 Fault_______________________________________
4.1 Safety instructions for troubleshooting
Troubleshooting on the measurement device must be performed
only by industrial mechanics or electricians who have been
instructed accordingly about the hazards posed during
troubleshooting.

Troubleshooting may require the power supply to be


switched on.
During troubleshooting, reaching into
the measurement device is strictly prohibited.

The operating personnel must be notified about upcoming troubleshooting


activities in advance.
A supervisor must be appointed.
A wide enough area within the workstation must be cordoned off, if necessary!

If the measurement device has been shut off completely for troubleshooting
activities, it must be secured against accidental restart.

Activate the emergency stop button and


attach a warning sign to the switch cabinet.

It is absolutely essential to use workshop equipment


that is appropriate for the troubleshooting work to be carried out.

Work on electrical equipment on the measurement device must only be carried


out by an electrician or trained personnel under the guidance and supervision of
an electrician according to electrical engineering regulations!

Make sure that screw connections loosened during the troubleshooting work
are always retightened!

If safety equipment needs to be disassembled during repair work, the safety


equipment must be reinstalled and checked directly after completion of the repair
work!

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 59
4.0 Fault_______________________________________
4.2 Fault report

If the fault is rectified by an industrial mechanic or


Note a technician, the respective fault must be entered into
the “Fault report” form (section 4.5).

4.3 Fault rectification during an emergency stop


• The “EMERGENCY stop” button is pressed.
• The “Fault” signal lamp is blinking red.

• Fault rectification
• Unlock the emergency stop switch.
• Resume the operation of the measurement device.

If there are no more faults indicated, the operation of the measurement device can
be resumed.
In case of repeated faults, do not resume operation of the measurement device,
but have it checked by a specialist (e.g industrial mechanic, electrician) without
delay.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 60
4.0 Fault_______________________________________
4.4 List of faults
Type:________________________ Project no.:__________________

Date Fault Operating hours Signature


description

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 61
5.0 Care (user) _____ ________
5.1 Care schedule

WHAT? WHEN? WHO?


Cleaning the
daily Operator
measurement device
Safety equipment daily Operator

Detected damage must be reported without delay!

Prior to starting maintenance work, always disconnect the


measurement device from the power supply and secure it
against restart.

5.2 Cleaning the measurement device


Disconnect the power supply and lock .
This prevents against unintended restart. Otherwise,
a risk of sustaining life-threatening injuries is posed.
The measurement device must only be cleaned with a
soft cloth or a cloth moistened with a cleaning agent
if it is free of benzine or solvents that could
corrode or damage the measurement device.

5.3 Protective safety equipment


The protective safety equipment must be checked for damage.
Have identified deficiencies rectified without delay.

• Environmental protection
Cloths soiled with oil must be collected and disposed of in
an environmentally friendly manner.

Local regulations regarding the protection of the environment


and occupational health and safety as well as instructions by the
lubricant manufacturer regulate the handling and use of
lubricants. These regulations must be observed.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 62
6.0 Maintenance/repair (industrial mechanics) ____
6.1 Safety instructions regarding maintenance and repair

Maintenance and repair work on the measurement device must


only be carried out by maintenance personnel who have been
instructed accordingly about hazards posed during maintenance
and repair work.

Maintenance and repair work may require the power supply


to be switched on. Therefore, reaching into the measurement
device during maintenance and repair work is strictly
prohibited.

The operating personnel must be notified about upcoming


maintenance and repair work in advance.
A supervisor must be appointed.
Adhere to all prescribed deadlines or time periods stipulated in the operating
manual for periodic tests/inspections.
A wide enough area for the maintenance and repair work must be cordoned off, if
necessary!
Prior to starting any maintenance work, always

run empty the measurement device


switch off the measurement device with the main switch and lock it.

If the measurement device has been completely shut down during the
maintenance and repair work, it must be secured against accidental restart.

Activate the emergency stop button and


attach a warning sign to the switch cabinet.

It is absolutely essential to use workshop equipment that is appropriate for the


maintenance and repair work to be carried out.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 63
6.0 Maintenance/repair (industrial mechanics) ____
6.2 Maintenance schedule

WHAT? WHEN? WHO?


Sheet steel infeed semi-annual Maintenance personnel

Detected damage must be rectified without delay!

Prior to carrying out maintenance work, all electrical, pneumatic


and hydraulic supplies of the measurement device must be
disconnected and secured against restart at the main switch.

6.3 Checking the sheet steel infeed


Check the sheet steel infeed for proper function and damage.

Local regulations regarding the protection of the environment


and occupational health and safety as well as instructions by the
lubricant manufacturer regulate the handling and use of
lubricants. These regulations must be observed.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 64
7.0 Maintenance/repair (electricians) ____
7.1 Safety instructions regarding maintenance and repair

Maintenance and repair work on the measurement device


must only be carried out by an electrician who has been
instructed accordingly about the hazards posed during
maintenance and repair work.

Maintenance and repair work may require the pneumatic and


power supply to be switched on. Therefore, reaching into the
measurement device during maintenance and repair work is
strictly prohibited.

The operating personnel must be notified about upcoming maintenance and repair
work in advance.
A supervisor must be appointed.
Adhere to all prescribed deadlines or time periods stipulated in the operating
manual for periodic tests/inspections.
A wide enough area for the maintenance and repair work must be cordoned off, if
necessary!
Prior to starting any maintenance work, always

run empty the measurement device


switch off the measurement device with the main switch and lock it.

If the measurement device has been completely shut down during the
maintenance and repair work, it must be secured against accidental restart.

Activate the emergency stop button and


attach a warning sign to the switch cabinet.

It is absolutely essential to use workshop equipment


that is appropriate for the maintenance and repair work to be carried out.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 65
7.0 Maintenance/repair (electricians) ____
7.1 Safety instructions regarding maintenance and repair

Work on electrical equipment on the measurement device must only be carried


out by an electrician or trained personnel under the guidance and
supervision of an electrician according to electrical engineering regulations!

Screw connections loosened during maintenance and repair work must


always be retightened!

If safety equipment needs to be disassembled during maintenance and repair


work, this safety equipment must be reinstalled and checked immediately after
the completion of the maintenance and repair work!

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 66
7.0 Maintenance/repair (electricians) ____
7.2 Maintenance schedule

WHAT? WHEN? WHO?


Check power contactors semi-annual electricians
Check all electrical protection
semi-annual electricians
equipment
Check all electrical switchgear
annual electricians
assembly
Check all electrical connections annual electricians

Detected damage must be rectified without delay!

Prior to carrying out maintenance work, the electrical power supply


to the measurement device must be disconnected and
secured against restart at the main switch.

Rectify detected damage on the protective safety equipment without


delay!

All persons involved in the maintenance and repair work on the measurement device
must

• strictly observe these and the product-specific maintenance


specifications, in the relevant operating manuals.

• Environmental protection
Electrical components must be disposed of in
an environmentally friendly manner.

Local regulations regarding the protection of the environment


and occupational health and safety as well as instructions by the
electronics manufacturer regulate the handling and use of
components. These regulations must be observed.
Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 67
8.0 Maintenance/repair (maintenance list) Sample ____
8.1 List of maintenance work
Type:________________________ Project no.:___________________

Date Job Operating Signature


description hours

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 68
9.0 Electronics______________________________________
9.1 Safety instructions for electronics

Work on electrical equipment must only be carried out by qualified


electricians with special knowledge and experience in this kind of work.
In case faults arise at the electrical power supply of the measurement device
the latter must be switched off immediately by using the main switch!
Only electricians may have access to and maintain the electrical system of the
measurement device. Always keep the cabinets locked if they are
are unattended.
Never work on live components!
Components of the measurement device that undergo inspection, maintenance or
repair work must be disconnected from the power supply.
Equipment used for enabling purposes must be secured against unintended
or automatic restart (lock fuses, block circuit breaker.)
The enabled electrical components must first be checked for the presence of
power, then earthed and short-circuited, and adjacent live components must be
isolated.
Only original fuses with prescribed current ratings must be used! Never repair or
bypass defective fuses. Only replace fuses with fuses of the same type.
Changes to the control programme may impact the safe operation. Changes to
programmes exclusively require the consent of the manufacturer.
Always make sure during repair work that changes to structural properties are not
detrimental to safety (e.g. clearance and creepage distances as well as other
clearances must not be narrowed by insulation).
If it is necessary to carry out work on live components
(only in exceptional situations!), an additional person must be
brought in who will activate the emergency switch or main switch in case of an
emergency. Only use insulated tools!
Proper earthing of the electrical system must be ensured by means of a
protective earth conductor system.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 69
9.0 Electronics______________________________________
9.2 Circuit diagram with BOM

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 70
10.0 Spare and wear parts list___________________
10.1 Spare parts order and customer service
We explicitly point out that spare parts or accessories not delivered by us
have not been tested and approved by us.
The installation and/or use of such products may therefore modify or have a
negative impact on structural properties of the measurement device.
The use of spare parts that have not been approved will
nullify the liability for the resulting consequences.

Important for all questions:


Note down all data from the rating plate on the measurement
Note device and if you have questions or would like to order spare parts,
submit the data from the rating plate.

Brockhaus Messtechnik GmbH & Co. KG


Gustav-Adolf-Str. 4 7
GERMANY 58507 Lüdenscheid
Phone: +49 (0) 2351 3644-0
Fax: +49 (0) 2351 3641-44
email: messtechnik@brockhaus.com

All rights are reserved, also those pertaining to translations, illustrations, modifications and
misunderstandings.
No part of this operating manual may be reproduced or duplicated in any form
(print, photocopy, microfilm or any other medium) nor may it be processed or distributed by means of
electronic systems without the written consent of the Brockhaus Messtechnik GmbH & Co. KG.
.

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 71
10.0 Spare and wear parts list___________________
10.2 Wear parts list

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 72
12.0 Instructing operating and set-up personnel______
12.1 Instruction

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 73
12.0 Instructing operating and set-up personnel______
12.1 Instruction
Instructing company / Instructor:

Verification for the


Instructing
operating personnel

Company to be instructed: Department:


Reason for instructions:
Location:

Date, time:

Content of the training

Declaration regarding the training:


This is to verify that the instructed party has been explicitly instructed today about the accident and health risks
the employees will be exposed to during work, as well as the equipment and measures to prevent against these
hazards. Prior to the first deployment on the measurement device, or at hazardous workstations where hazardous
substances are handled, the operating staff has been instructed about specific hazards posed by this work as well
as their proper conduct accordingly.
Instructed personnel
Name First name Signature

Next instruction date: Scheduled topics: Signature (Instructor)

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 74
12.0 Instructing operating and set-up personnel______
12.1 Instruction
Instructing company / Instructor:

Verification for the


Instructing of
set-up personnel

Company to be instructed: Department:


Reason for instructions:
Location:

Date, time:

Content of the instruction

Declaration regarding the training:


This is to verify that the instructed party has been explicitly instructed today about the accident and health risks
the employees will be exposed to during work, as well as the equipment and measures to prevent against these
hazards. Prior to the first deployment on the measurement device, or at hazardous workstations where hazardous
substances are handled, the operating staff has been instructed about specific hazards posed by this work as well
as their proper conduct accordingly.
Instructed personnel
Name First name Signature

Next instruction date: Scheduled topics: Signature (Instructor)

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44
P. 75
13.0 Technical documents______ ___________
13.1 Operating manuals of components

Brockhaus GmbH & Co. KG Gustav-Adolf-Str. 4 GERMANY-58507 Lüdenscheid Phone: 02351/3644-0 Fax: 02351/3644-44