CU 242
Dual pump unit
Table of contents
English (GB)
Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Български (BG)
Упътване за монтаж и експлоатация. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Čeština (CZ)
Montážní a provozní návod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Deutsch (DE)
Montage- und Betriebsanleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Dansk (DK)
Monterings- og driftsinstruktion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Eesti (EE)
Paigaldus- ja kasutusjuhend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Español (ES)
Instrucciones de instalación y funcionamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Suomi (FI)
Asennus- ja käyttöohjeet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Français (FR)
Notice d'installation et de fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Ελληνικά (GR)
Οδηγίες εγκατάστασης και λειτουργίας . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Hrvatski (HR)
Montažne i pogonske upute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Magyar (HU)
Telepítési és üzemeltetési utasítás. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Italiano (IT)
Istruzioni di installazione e funzionamento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Lietuviškai (LT)
Įrengimo ir naudojimo instrukcija . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Latviešu (LV)
Uzstādīšanas un ekspluatācijas instrukcija . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Nederlands (NL)
Installatie- en bedieningsinstructies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Polski (PL)
Instrukcja montażu i eksploatacji . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Português (PT)
Instruções de instalação e funcionamento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
Română (RO)
Instrucţiuni de instalare şi utilizare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Srpski (RS)
Uputstvo za instalaciju i rad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Русский (RU)
Паспорт, Руководство по монтажу и эксплуатации. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Svenska (SE)
Monterings- och driftsinstruktion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Slovensko (SI)
Navodila za montažo in obratovanje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
3
Türkçe (TR)
Table of contents
4 CU 242
English (GB) Installation and operating instructions
English (GB)
Original installation and operating instructions 8.2 Code 2 (Power phase missing) . . . . . . . . . . . . . . . . . 15
Table of contents 8.3 Code 3 (External alarm via DI). . . . . . . . . . . . . . . . . . 15
8.4 Code 4 (Too many motor restarts) . . . . . . . . . . . . . . . 15
1. General information . . . . . . . . . . . . . . . . . . . . . . . . 5 8.5 Code 9 (Power phase sequence wrong). . . . . . . . . . . . 15
1.1 Hazard statements . . . . . . . . . . . . . . . . . . . . . . . . . . 5 8.6 Code 12 (Service needed) . . . . . . . . . . . . . . . . . . . . 15
1.2 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 8.7 Code 17 (Low system performance) . . . . . . . . . . . . . . 16
2. Installing the product . . . . . . . . . . . . . . . . . . . . . . .6 8.8 Code 22 (Moisture in motor of pump) . . . . . . . . . . . . . 16
2.1 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 8.9 Code 25 (Wrong configuration) . . . . . . . . . . . . . . . . . 16
2.2 Mechanical installation . . . . . . . . . . . . . . . . . . . . . . .6 8.10 Code 46 (External warning via DI) . . . . . . . . . . . . . . . 16
2.3 Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . .7 8.11 Code 48 (Motor is overloaded) . . . . . . . . . . . . . . . . . 16
8.12 Code 57 (Missing water in the application) . . . . . . . . . . 16
3. Starting up the product . . . . . . . . . . . . . . . . . . . . . .7
8.13 Code 69 (Winding temperature too high) . . . . . . . . . . . 16
3.1 Connecting to Grundfos GO Remote . . . . . . . . . . . . . . .7
8.14 Code 84 (Memory storage media faulty). . . . . . . . . . . . 16
3.2 Startup wizard on Grundfos GO Remote . . . . . . . . . . . .7
8.15 Code 94 (Limit exceeded 1) . . . . . . . . . . . . . . . . . . . 17
3.3 Startup wizard on the operating panel . . . . . . . . . . . . . .7
8.16 Code 95 (Limit exceeded 2) . . . . . . . . . . . . . . . . . . . 17
3.4 How to enable Bluetooth on the operating panel . . . . . . . .8
8.17 Code 117 (Door opened) . . . . . . . . . . . . . . . . . . . . . 17
3.5 How to disable Bluetooth on the operating panel . . . . . . .8
8.18 Code 130 (Cable theft) . . . . . . . . . . . . . . . . . . . . . . 17
3.6 Testing the product. . . . . . . . . . . . . . . . . . . . . . . . . .8
8.19 Code 157 (Real-time clock monitoring) . . . . . . . . . . . . 17
4. Product introduction. . . . . . . . . . . . . . . . . . . . . . . .8 8.20 Code 159 (Communication error CIMxxx) . . . . . . . . . . . 17
4.1 Product description . . . . . . . . . . . . . . . . . . . . . . . . .8 8.21 Code 165 (Signal fault) . . . . . . . . . . . . . . . . . . . . . . 17
4.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 8.22 Code 191 (High water level) . . . . . . . . . . . . . . . . . . . 17
4.3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 8.23 Code 205 (Level switch inconsistency) . . . . . . . . . . . . 17
4.4 Application types . . . . . . . . . . . . . . . . . . . . . . . . . . .8 8.24 Code 225 (Communication error pump module) . . . . . . . 17
4.5 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 8.25 Code 226 (Communication error IO module) . . . . . . . . . 18
4.6 Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 8.26 Code 229 (Water on floor) . . . . . . . . . . . . . . . . . . . . 18
4.7 Supported communication interface modules and
9. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
9.1 Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5. Control functions . . . . . . . . . . . . . . . . . . . . . . . . . 10 9.2 Mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1 Operating panel . . . . . . . . . . . . . . . . . . . . . . . . . . 10 9.3 Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6. Setting the product. . . . . . . . . . . . . . . . . . . . . . . . 10 9.4 Environmental data . . . . . . . . . . . . . . . . . . . . . . . . 18
6.1 Setting the application type with Grundfos GO Remote. . . 10 9.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.2 Setting the sensor type . . . . . . . . . . . . . . . . . . . . . . 10 10. Disposing of the product . . . . . . . . . . . . . . . . . . . . 18
6.3 Setting the start level . . . . . . . . . . . . . . . . . . . . . . . 10
6.4 Setting the stop level . . . . . . . . . . . . . . . . . . . . . . . 11
1. General information
6.5 Setting the high level . . . . . . . . . . . . . . . . . . . . . . . 11
6.6 Stop delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Read this document before you install the product. Instal-
6.7 Power-on delay . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 lation and operation must comply with local regulations
6.8 Dry-running protection. . . . . . . . . . . . . . . . . . . . . . . 11 and accepted codes of good practice
6.9 Multipump settings . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.10 Using the same level switch for the start and stop level . . 12 1.1 Hazard statements
6.11 Automatic test run . . . . . . . . . . . . . . . . . . . . . . . . . 12 The symbols and hazard statements below may appear in Grundfos
6.12 Setting the limit exceeded function . . . . . . . . . . . . . . . 12 installation and operating instructions, safety instructions and
6.13 Signal-detection time . . . . . . . . . . . . . . . . . . . . . . . 12 service instructions.
6.14 Setting the maximum number of restarts with Grundfos DANGER
GO Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Indicates a hazardous situation which, if not avoided, will
6.15 Setting the service interval with Grundfos GO Remote . . . 12 result in death or serious personal injury.
6.16 Operating the product . . . . . . . . . . . . . . . . . . . . . . . 12
6.17 Motor protection . . . . . . . . . . . . . . . . . . . . . . . . . . 13 WARNING
6.18 Alarm reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Indicates a hazardous situation which, if not avoided,
6.19 Setting the buzzer with Grundfos GO Remote . . . . . . . . 13 could result in death or serious personal injury.
6.20 Setting units for Grundfos GO Remote. . . . . . . . . . . . . 13
6.21 Setting units for the operating panel with Grundfos GO CAUTION
Remote. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Indicates a hazardous situation which, if not avoided,
6.22 Setting the user-configurable logwith Grundfos GO could result in minor or moderate personal injury.
Remote. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 The hazard statements are structured in the following way:
6.23 Setting a time schedule with Grundfos GO Remote . . . . . 14
6.24 GENIbus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 SIGNAL WORD
6.25 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Description of the hazard
6.26 Starting the startup wizard with the operating panel . . . . . 14 Consequence of ignoring the warning
• Action to avoid the hazard.
7. Servicing the product . . . . . . . . . . . . . . . . . . . . . . 14
7.1 Updating the product software . . . . . . . . . . . . . . . . . . 14
7.2 Replacing the battery . . . . . . . . . . . . . . . . . . . . . . . 14
1.2 Notes
7.3 Replacing the control unit. . . . . . . . . . . . . . . . . . . . . 14 The symbols and notes below may appear in Grundfos installation
7.4 Replacing the CIM module . . . . . . . . . . . . . . . . . . . . 15 and operating instructions, safety instructions and service
instructions.
8. Fault finding the product . . . . . . . . . . . . . . . . . . . . 15
8.1 Overview of alarm and warning codes . . . . . . . . . . . . . 15
5
English (GB)
TM071905
function or damage to the equipment.
Tips and advice that make the work easier. 2. Remove the back cover.
2.1 Location
Install the product in a location that meets the following
requirements:
• Place the product in a flood-safe place.
• Make sure that the ambient temperature is within the limits.
TM071906
• Install the product as close as possible to the connected pumps,
sensors, and accessories.
• The product must be protected from direct sunlight.
• The product must be easily accessible. 3. Break off the tap.
• We recommend that you install the product in a protective shed
or enclosure to avoid direct sunlight and rain.
• Indoor installation: The product must be installed in a well-
ventilated room to ensure cooling of its components.
1
160.5 (6.3")
TM071977
110.5 (4.35")
Max. 5 (0.2")
1 Nm
Related information
7.3 Replacing the control unit
2.2.2 Installing a communication interface module
You can fit a communication interface module (CIM) in the control
unit to enable communication with external systems. The module is
optional and is not delivered with the product. See the installation
and operating instruction for the module regarding electrical
connections.
6
5. If supplied, place the labels on the back cover.
English (GB)
TM070570
Type: CIM XXX
XXX
TM071908
Android devices.
1. Open Grundfos GO Remote on your device. Make sure that
Bluetooth is enabled.
6. Refit the back cover to the CU product and secure it with the Your device must be within reach of the product to establish
mounting screw. Secure cables using the cable tie holders. Bluetooth connection.
2. Press the Bluetooth CONNECT button on Grundfos GO
Remote.
3. Press the connect button on the operating panel. The blue LED
above the connect button is flashing until your device is
connected. Once the connection is established, the LED will be
permanently on.
Grundfos GO Remote is now loading the data for the product.
Related information
3.4 How to enable Bluetooth on the operating panel
3.5 How to disable Bluetooth on the operating panel
Related information
7.3 Replacing the control unit
type and sensor levels. For some products, you can also set the
nominal pump current and number of phases.
If you have an analog sensor, select S-1 and set the height of the
Related information different levels, from dry running to high level.
If you have a digital sensor, select S-2 and enable or disable the
8.20 Code 159 (Communication error CIMxxx)
dry-running level, the start level for pump 2, if available and the high
level.
2.3 Electrical connection
To change settings, use the Up and Down buttons on the operating
2.3.1 Connecting the power supply panel.
Use the OK button to confirm each setting and navigate to the next
Changes or modifications not expressly approved by setting.
Grundfos may void the user's authority to operate the For filling applications, you must use Grundfos GO Remote. Units
equipment. can only be changed with Grundfos GO Remote.
7
Related information 4.2 Intended use
English (GB)
6.1 Setting the application type with Grundfos GO Remote The product is designed to control one or two pumps.
6.26 Starting the startup wizard with the operating panel The product can be configured for the following two purposes:
• dewatering in groundwater supply
3.4 How to enable Bluetooth on the operating panel
• filling a tank.
If the Bluetooth signal on the operating panel has been disabled for
some reason, you are not able to connect with Grundfos GO The product can be used for the following applications:
Remote. You must enable Bluetooth first. • groundwater supply
1. Press and hold the connect button on the operating panel for 15 • irrigation systems
seconds. Wait for the blue LED to light up.
• small waterworks
2. Press the Bluetooth CONNECT button on Grundfos GO • network pumping stations
Remote.
• main pumping stations
3. Press the connect button on the operating panel. The blue LED • commercial buildings
above the connect button is flashing blue until your device is
• municipal systems.
connected.
Grundfos GO Remote is now loading the data for the product. The product must not be exposed to strong solvents or oil-
containing liquids.
Related information
3.1 Connecting to Grundfos GO Remote 4.3 Features
The control unit features among others the following functions:
3.5 How to disable Bluetooth on the operating panel • support of up to two pumps
In some installation areas, it is not allowed to have a Bluetooth • manual and automatic control of the pump
signal enabled during operation. After installation, the Bluetooth
signal must be disabled manually. • Bluetooth pairing with Grundfos GO Remote
1. Press and hold the connect button on the operating panel for 15 • operating indication, such as power on and pump running
seconds. Wait for the blue LED to switch off. • alarm and warning indication, such as power phase missing and
Grundfos GO Remote is no longer connected to the product. high-water level
• motor and phase failure protection
Related information
• setting of stop delays matching the actual operating conditions
3.1 Connecting to Grundfos GO Remote
• automatic alternation of pumps.
3.6 Testing the product
4.4 Application types
When you have made all the electrical installations and completed
the startup wizard, you can test the system. You can choose between two application types:
For dewatering applications: • Dewatering
• Ensure the pit is filled with water and check that the pump starts • Fill.
automatically at the defined level. You can set the application type with Grundfos GO Remote.
• If possible, test the dry-running function by starting the pump
manually and wait while the pit with the pump is emptied. Check Dewatering
that the control unit indicates an alarm and stops the pump
when the defined level is reached.
For filling applications:
• Start by draining the tank to be filled. When the tank is empty
and the start level is reached, the pump must start. When the 1
tank is full and the stop level is reached, the pump must stop.
• Test the high-level function by stopping the pump manually and
2
continue to fill the tank without the pump with water. Check that
the control unit indicates an alarm when the defined level is
reached. 3
4
• Test the dry-running function by starting the pump manually and 5
wait while the tank with the pump is emptied. Check that the
control unit indicates an alarm and stops the pump when the
TM075202
8
signal from the High level sensor can be used to activate an output 4.6 Identification
English (GB)
relay which can then be used to give a visual or acoustic alarm or
send a signal to a SCADA system. 4.6.1 Nameplate
If the pump is running and the liquid level in the tank or well falls
below the dry-running level, the dry-running protection stops the
pump to ensure that it is not damaged mechanically.
Fill
1
2
TM072129
3
4
TM075203
5 Pos. Description
1 Product name
2 Supply voltage
3 Start level P1: start level for pump 1 6 Enclosure type according to NEMA
4 Start level P2: start level for pump 2 7 Production code (year and week)
9
5. Control functions 6. Setting the product
English (GB)
TM075156
6.2.1 Setting the sensor type with Grundfos GO Remote
12
1. Go to Settings > Level control > Sensor type.
2. Select the type.
Pos. Symbol Description
• Analog sensors
1 Display • Digital sensors
11 • Press this button during startup to reset set- 6.3.2 Setting the start level with the operating panel
tings and start over or to reset an alarm or The settings apply to analog sensors. For digital sensors, the
warning. setting is automatically activated.
Operating mode for the pump: 1. Press and hold OK until the display and dry running start
• On: The pump has been switched on man- flashing.
1 2 3
ually.
2. Continuously press OK until the indicator light for the start level
12 On Off Auto
• Off: The pump has been switched off man- for pump 1 starts flashing.
ually.
Status Settings Assist
• Auto: The pump is running automatically
based on settings.
Setpoint Control mode
13 Display The display shows the pump status.
5.00 bar Const. pressure
Lock symbol:
14 If the symbol is lit, the control unit is locked from
making Operaring
changes.mode Actual controlled value
Normal
Alarm and warning symbol:
15 Red: Alarm
4.90 bar
TM075197
Yellow: Warning
10
4. Press OK. 2. Set the high level stop delay time.
English (GB)
The indicator light for the start level for pump 2 starts flashing.
6.6 Stop delay
The stop delay is the time from when the stop level is reached until
the pump stops. The stop delay prevents the pump from starting
and stopping too frequently and reduces water hammer in long
pipes.
6.6.1 Setting the stop delay with Grundfos GO Remote
1. Select Settings > Level control > Stop delay > State
2. Select Stop delay time.
3. Set the Stop delay time.
TM075198
6.7 Power-on delay
With this function it is possible to delay the startup of the pump after
5. Set the start level for pump 2 by using the power supply has been switched on. The purpose is to avoid
the Up and Down buttons. disturbing the main power network which could happen if several
pumps start up immediately when the power supply is switched on.
6. Continuously press OK until the display stops flashing.
The settings have now been stored. 6.7.1 Setting the power-on delay with Grundfos GO Remote
1. Go to Settings > Power-on delay.
6.4 Setting the stop level
2. Set the function to Enabled.
6.4.1 Setting the stop level with Grundfos GO Remote
3. Set the time delay.
The settings apply to analog sensors. For digital sensors, the
setting is automatically activated.
6.8 Dry-running protection
The stop level is the same for pump 1 and pump 2.
If the pump is running and the liquid level in the tank or pit becomes
1. Go to Settings > Level control > Stop level lower than the dry-running level, the dry-running protection will stop
2. Set the stop level. the pump to ensure that it is not damaged.
Dry-running protection is dependent on a feedback signal from a
If you are using the same level for start and stop, re- level sensor installed in the tank or pit.
member to set a stop delay. This will prevent the pump
from starting and stopping too frequently. 6.8.1 Setting the dry-running level with Grundfos GO Remote
1. Go to Settings > Level control > Dry-running level.
6.4.2 Setting the stop level with the operating panel
2. Set the dry-running level.
The settings apply to analog sensors. For digital sensors, the
setting is automatically activated. The dry-running level must be set to a value which en-
The stop level is the same for pump 1 and pump 2. sures that the pump is not damaged due to dry-run-
ning. The specific level depends on the installed pump
1. Press and hold OK until the display starts flashing.
type. See the installation and operating instructions for
2. Press OK once. the product.
The current stop level is indicated on the display.
6.8.2 Setting the dry-running level with the operating panel
3. Set the stop level using the Up and Down buttons. 1. Press and hold OK until the display starts flashing.
4. Continuously press OK to confirm all other settings and to exit 2. Set the dry-running level using the Up or Down button.
the setup.
3. Continuously press OK to confirm all other settings and to exit
If you are using the same level for the start and stop the setup.
level, remember to set a stop delay. This will prevent
the pump from starting and stopping too frequently. 6.9 Multipump settings
The control unit enables start and stop of the two pumps alternately.
6.5 Setting the high level The pump with the lowest number of running hours is always
started first. The function ensures that the running hours of the
6.5.1 Setting the high level with Grundfos GO Remote
pumps are the same.
For analog sensors: It is possible to set a time delay before the next pump is started.
1. Go to Settings > Level control > High level.
6.9.1 Setting the multipump settings with Grundfos GO Remote
2. Set the high level.
1. Go to Settings > Multi pump settings.
For digital sensors:
1. Go to > Settings > IO modules 2. Set Inter pump delay.
This is the starting delay between the pumps ensuring that they
2. Select which terminal to configure.
do not start at the same time.
6.5.2 Setting the high level with the operating panel
3. Set Max number of running pumps.
The settings apply to analog sensors This is the maximum number of pumps that are allowed to run at
1. Press and hold OK until the display starts flashing. the same time.
2. Press OK four times. The current high level is indicated on the 4. Set Max run time.
display. This is the maximum period of time the pump is allowed to run
3. Set the high level using the Up and Down button. before it stops.
For digital sensors, enable or disable the setting. 5. Set Pump pause time.
1. Press OK once to complete the setting. This is how long the pump must remain paused before it starts
again.
6.5.3 Setting the high level stop delay
1. Go to Settings > Level control > High level stop delay.
11
6.10 Using the same level switch for the start and stop 4. Enter the number of hours until next service and press OK.
English (GB)
level
6.16 Operating the product
1. Set one digital input to Start pump 1 or Stop. All other digital
inputs must be disabled. 6.16.1 Automatic operation
2. Set a stop delay. In automatic operating mode, the control unit starts and stops the
pump based on the signals it receives from the connected level
This will prevent the pump from starting and stopping too
sensors and the corresponding level settings within the control unit.
frequently.
Related information
6.11 Automatic test run
4.4 Application types
This function prevents a pump from choking or seizing up as a
result of deposits buildup. The function is used in pits that have had 6.16.2 Manual operation
no inlet flow for a long period. The function ensures that the pump 6.16.2.1 Starting and stopping the pump manually with
starts as often as set in Automatic test run > Interval. The pump Grundfos GO Remote
operates for the number of seconds set by the user.
1. Go to Settings > Control, pump 1 or Control, pump 2.
6.11.1 Setting the automatic test run function with Grundfos
GO Remote 2. Start the pump by selecting On and pressing OK.
1. Go to Settings > Automatic test run. 3. Stop the pump by selecting Off and pressing OK.
6.12 Setting the limit exceeded function 6.16.2.2 Starting and stopping the pump manually with the
operating panel
Use this function to monitor an IO terminal or one of the internal
values, such as power, current or result pulse flow. 1. To start a pump manually, press and hold the Pump button until
If a set limit is reached, a selected action can take place. You can the pump starts.
set two limit exceeded functions, meaning that you can monitor two The On indicator light is lit when the pump is operating in
parameters or two limits of the same parameter simultaneously. manual mode.
1. Go to > Settings > Limit 1 exceeded or Limit 2 exceeded. 2. Stop the pump by pressing the Pump button.
2. Follow on-screen instructions. The Off indicator light is lit when the pump is stopped.
Related information
6.13 Signal-detection time
6.16.2.1 Starting and stopping the pump manually with Grundfos
The signal-detection time is the minimum time a level has to be GO Remote
active before the control unit initiates an action, such as starting or
stopping a pump. 6.16.2.3 Choosing what the pump must do after manual start
The following can be configured:
6.13.1 Setting the signal-detection time with Grundfos GO
Remote • Automatic return
1. Go to Settings > Level control > Signal detection time. Here you select if the pump must automatically return to a
defined operating mode when the manual start ends.
2. Set the signal-detection time.
• Return to
6.14 Setting the maximum number of restarts with Here you select whether the pump must return to automatic
operating mode or stop when the manual start ends and
Grundfos GO Remote
Automatic return has been enabled.
If the pump is seized up as a result of deposits buildup, it will be • Forced start time
stopped automatically due to overheating, provided that the motor Here you set the time period in which the pump must run in
protection has been set. When the motor has cooled down, the manual operating mode.
control unit will unsuccessfully try to restart the pump and this
scenario will be repeated. 1. Go to Settings > Manual start.
In order to prevent this, it is possible to set a maximum number of 2. Select Automatic return and choose one of the following
restart attempts within a set interval. options:
1. Go to Settings > Max number of restarts. • Disabled
2. Enable the function. • Enabled.
3. Set the interval within which the allowed number of restarts are 3. Go one step back in the menu and select Return to.
to be counted.
4. Choose one of the following options:
4. Set the maximum number of pump restarts which are allowed • Auto
during the set interval.
• Off.
Related information 5. Go one step back in the menu and select Forced start time.
8.4 Code 4 (Too many motor restarts)
6. Set the time period in which the pump must run in manual
6.15 Setting the service interval with Grundfos GO operating mode.
Remote Related information
You can set a time in Grundfos GO Remote in order to get a 6.16.2.1 Starting and stopping the pump manually with Grundfos
reminder that the pump needs service when the time comes. GO Remote
1. Go to Settings > Service > State
2. Select Enable and press OK.
3. Select the pump.
12
6.17 Motor protection 6.18.3 Resetting alarms and warnings on the operating panel
English (GB)
You can manually reset alarms and warnings on the operating
Make sure that all settings are entered according to the panel. However, if the fault causing the alarm or warning has not
pump and system requirements to avoid malfunction. been removed, the alarm or warning will appear again.
1. Press Reset on the operating panel to reset the alarm or
6.17.1 Overheat protection warning.
The control unit offers thermal protection for the connected motors.
Two types of thermal-protection sensor can be connected to the 6.19 Setting the buzzer with Grundfos GO Remote
control unit: a PTC sensor (analog) and a thermal switch (digital). The internal buzzer is used to give an acoustic sound if there is a
Under normal running conditions, the sensor will act as a short warning or an alarm.
circuit, but when its temperature limit is reached, it will open and tell 1. Go to Settings > Buzzer settings.
the control unit that the temperature is too high, and the pump is
stopped. When the temperature has dropped to the sensor-trigger 2. Select when the buzzer is to be activated:
level, the pump will return to normal running conditions. It will not be • All alarms
possible to start the pump manually as long as the temperature is
too high. • All alarms and warnings.
Related information
8.11 Code 48 (Motor is overloaded)
6.17.3 Moisture protection
When a moisture sensor is installed in series with the temperature
sensor, the control unit needs to know how to determine whether
there is a high temperature or moisture in the pump. If the
temperature is too high, normally the temperature sensor will go
back to its normal stage when the temperature has dropped to its
trigger level. If there is moisture in the pump, then the moisture
sensor will keep the series connection open until the pump is
opened and serviced.
To determine which sensor has been active, a cool down
time must be entered. This is the time that will normally pass until
the temperature has dropped enough for the temperature sensor to
return to its normal stage. If the cool down time is exceeded, the
control unit will assume that there is moisture in the pump, and it
will send a moisture alarm.
13
6.22 Setting the user-configurable log with Grundfos GO 4. Disable the setting and press Done.
English (GB)
Remote
All menus in Grundfos GO Remote are unlocked.
The user-configurable log function is used for logging the
configured parameters you have set in Grundfos GO Remote. 6.26 Starting the startup wizard with the operating panel
1. Go to Settings > User configurable logs. • Press and hold the OK button for 5 seconds
2. Follow on-screen instructions. until S-1 or S-2 starts flashing.
Related information
Saved logs can be found in the Status menu. 3.3 Startup wizard on the operating panel
6.25.2 Unlocking the operating panel Remember to save the controller's settings in Grundfos GO Remote
under Settings. The settings can then be transferred to the new
The operating panel can only be unlocked with Grundfos GO
control unit when installed.
Remote.
1. Switch off the power supply to the product and
1. Go to Settings > Security > Lock Display.
other components with external supply.
2. Disable the setting and press Done.
2. Write down the terminal connection of each wire to ensure
The lock symbol on the operating panel is switched off. correct re-connection.
14
7.4 Replacing the CIM module
English (GB)
Code number Description
Code 205 Level-switch inconsistency.
WARNING
Electric shock Communication error, pump
Code 225
Death or serious personal injury module.
‐ Switch off the power supply before making any electri- Communication error, IO mod-
cal connections. Code 226
ule.
‐ Make sure that the power supply cannot be switched Code 229 Water on the floor.
on accidentally.
1. Switch off the power supply to the product and 8.2 Code 2 (Power phase missing)
other components with external supply. • Alarm code 2 is shown on the display.
2. Write down the terminal connection of each wire to ensure • The alarm symbol on the display turns red and the pump stops.
correct re-connection. • Alarm code Power phase missing is displayed in Grundfos GO
3. Disconnect all wires connected to the CIM module. Remote.
5. Remove the module from the control unit. The product is configured for 2 • Make sure that the Mains
or 3 phases but only 1 phase is Power connection setting is
6. Fit the new module. connected. correct according to the
number of phases connected
7. Connect all wires.
(1, 2 or 3 phases).
8. Fault finding the product One of the power supply • Connect the phase.
phases is not connected.
WARNING The fuse is blown somewhere • Replace the fuse.
Electric shock on the incoming power line.
Death or serious personal injury
‐ Switch off the power supply before you start any work 8.3 Code 3 (External alarm via DI)
on the product.
• Alarm code 3 is shown on the display.
‐ Make sure that the power supply cannot be switched • The alarm symbol on the display turns red and the pump stops.
on accidentally.
• Alarm code External alarm from DI is displayed in Grundfos
Fault finding and fault correction must be carried out by qualified GO Remote.
persons.
Cause Remedy
8.1 Overview of alarm and warning codes An external alarm is activated • Check the device connected
via the digital input. to the external digital input.
Code number Description
Code 2 The power phase is missing. 8.4 Code 4 (Too many motor restarts)
Code 3 External alarm via digital input. • Alarm code 4 is shown on the display.
• The alarm symbol on the display turns red and the pump stops.
Code 4 Too many motor restarts.
• Alarm code Too many motor restarts is displayed in Grundfos
The power-phase sequence is GO Remote.
Code 9
wrong.
Code 12 Service is needed. Cause Remedy
Code 17 Low performance. The pump has been blocked or • Remove the blockage from
partly blocked causing overload the pump.
Code 22 Moisture in pump motor. in the motor.
Code 25 Wrong configuration.
Related information
External warning via digital in-
Code 46 6.14 Setting the maximum number of restarts with Grundfos GO
put.
Remote
Code 48 The motor is overloaded.
Code 57 Missing water in the application.
8.5 Code 9 (Power phase sequence wrong)
• Alarm code 9 is shown on the display.
The winding temperature is too
Code 69 • The alarm symbol on the display turns red and the pump stops.
high.
The memory-storage media is • Alarm code Power phase sequence wrong is displayed in
Code 84 Grundfos GO Remote.
faulty.
Code 94 Limit exceeded 1. Cause Remedy
Code 95 Limit exceeded 2. The power supply phase is set • Interchange two phases.
incorrectly.
Code 117 The door is opened.
Code 130 Cable theft. 8.6 Code 12 (Service needed)
Code 157 Real-time clock monitoring. • Warning code 12 is shown on the display if you press
Code 159 Communication error, CIM xxx. the Up or Down button.
• The warning symbol on the display turns yellow and the pump's
Code 165 Signal fault.
operating mode is unchanged.
Code 181 Signal fault, PTC input. • Warning code Service needed is displayed in Grundfos GO
Code 191 High water level. Remote.
15
English (GB)
16
8.15 Code 94 (Limit exceeded 1)
English (GB)
Cause Remedy
• Warning code 94 is shown on the display if you press The battery for the real time • Replace the battery with a
the Up or Down button. clock is missing or worn out so new one.
the product is unable to
• Alarm code 94 is shown on the display.
maintain time and date.
• The alarm symbol on the display turns red and the pump stops.
• The warning symbol on the display turns yellow, and the pump's 8.20 Code 159 (Communication error CIMxxx)
operating mode is unchanged.
• Warning code 159 is shown on the display if you press
• Alarm code or warning code Limit exceeded, sensor 1 is the Up or Down button.
displayed in Grundfos GO Remote.
• The warning symbol on the display turns yellow and the pump's
Cause Remedy operating mode is unchanged.
• Warning code Communication error CIMxxx is displayed in
The limit exceeded 1 parameter 1. Check the input.
Grundfos GO Remote.
set in Grundfos GO Remote is
exceeded. 2. Change the configuration by • The CIM module is unable to communicate with the product.
adjusting the limits set in
Grundfos GO Remote. Cause Remedy
The CIM module is installed • Ensure that the module,
8.16 Code 95 (Limit exceeded 2) incorrectly. including cables, is fitted
correctly.
• Warning code 95 is shown on the display if you press
the Up or Down button. The CIM module is defective. • Contact Grundfos.
• Alarm code 95 is shown on the display.
Related information
• The alarm symbol on the display turns red and the pump stops.
2.2.2 Installing a communication interface module
• The warning symbol on the display turns yellow, and the pump's
operating mode is unchanged. 8.21 Code 165 (Signal fault)
• Alarm code or warning code Limit exceeded, sensor 2 is • Alarm code 165 is shown on the display.
displayed in Grundfos GO Remote.
• The alarm symbol on the display turns red and the pump stops.
Cause Remedy • Alarm code Signal fault is displayed in Grundfos GO Remote.
The limit exceeded 2 parameter 1. Check the input.
Cause Remedy
set in Grundfos GO Remote is
exceeded. 2. Change the configuration by The signal from the sensor is • Go to Settings > Level
adjusting the limits set in out of the configured range. control in Grundfos GO
Grundfos GO Remote. Remote and ensure that the
configured range corresponds
8.17 Code 117 (Door opened) to the physical application
• Warning code 117 is shown on the display if you press type.
the Up or Down button. • Change the sensor, if needed.
• The warning symbol on the display turns yellow and the
operating mode of the pump is unchanged. 8.22 Code 191 (High water level)
• Warning code Door opened is displayed in Grundfos GO • Alarm code 191 is shown on the display.
Remote. • The alarm symbol on the display turns red, but the pump's
operating mode is unchanged.
Cause Remedy
• Alarm code High water level is displayed in Grundfos GO
The door to the control-unit • Check the room with the Remote.
room has been opened. control unit.
Cause Remedy
8.18 Code 130 (Cable theft) The defined start level did not • Check and configure the
• Warning code 130 is shown on the display if you press start the pump. sensor start level.
the Up or Down button.
The pump is not big enough to • Contact Grundfos or an
• The warning symbol on the display turns yellow, and the pump's remove the water. authorised service workshop.
operating mode is unchanged.
The level sensor is defective • Check the functionality of the
• Warning code Cable theft is displayed in Grundfos GO Remote. and not reacting on level level sensor.
changes.
Cause Remedy
The cable is missing or • Verify that the cable is 8.23 Code 205 (Level switch inconsistency)
defective. missing.
• Alarm code 205 is shown on the display.
• Inspect the cable.
• The alarm symbol on the display turns red and the pump stops.
8.19 Code 157 (Real-time clock monitoring) • Alarm code Level switch inconsistency is displayed in
Grundfos GO Remote.
• Warning code 157 is shown on the display if you press the Up
or Down button. Cause Remedy
• The warning symbol on the display turns yellow, and the pump's A float switch could be • Check the functionality of
operating mode is unchanged. defective or stuck. each float switch.
• Warning code Real-time clock out of order is displayed in
Grundfos GO Remote. 8.24 Code 225 (Communication error pump module)
• Alarm code 225 is shown on the display.
• The alarm symbol on the display turns red and the pump stops.
• Alarm code Communication fault, pump module is displayed
in Grundfos GO Remote.
17
• The product is unable to communicate with the IO module. 9.3 Temperature
English (GB)
137 (5.4")
• Warning code 229 is shown on the display if you press
the Up or Down button.
TM072339
• The warning symbol on the display turns yellow and the pump's
operating mode is unchanged.
• Warning code Water on floor is displayed in Grundfos GO
Remote.
10. Disposing of the product
Cause Remedy This product or parts of it must be disposed of in an environmentally
The sensor detects water on • Check for water leakage. sound way.
the floor. 1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company or
9. Technical data service workshop.
9.1 Electrical data 3. Dispose of the waste battery through the national collective
schemes. If in doubt, contact your local Grundfos company.
Supply voltage
24 VDC, - 10 %/+ 10 %. The crossed-out wheelie bin symbol on a product
Power supply is required to be class 2. means that it must be disposed of separately from
Check that the supply voltage corresponds to the values stated on household waste. When a product marked with this
the nameplate. symbol reaches its end of life, take it to a collection
point designated by the local waste disposal authori-
Maximum power dissipation ties. The separate collection and recycling of such
products will help protect the environment and human
Object Maximum power dissipation
health.
99347488 3.4 W *
See also end-of-life information at www.grundfos.com/product-
* Excluding power to USB and CIM modules. recycling.
GENIbus terminal
- 7 to + 12 VDC.
Nominal current condition: 4 mADC.
Short-circuit current condition: 328 mA.
18
Argentina Estonia Lithuania South Africa
Grundfos companies
Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps Eesti OÜ GRUNDFOS Pumps UAB GRUNDFOS (PTY) LTD
Ruta Panamericana km. 37.500industin Peterburi tee 92G Smolensko g. 6 16 Lascelles Drive, Meadowbrook Estate
1619 - Garín Pcia. de B.A. 11415 Tallinn LT-03201 Vilnius 1609 Germiston, Johannesburg
Tel.: +54-3327 414 444 Tel.: + 372 606 1690 Tel.: + 370 52 395 430 Tel.: (+27) 10 248 6000
Fax: +54-3327 45 3190 Fax: + 372 606 1691 Fax: + 370 52 395 431 Fax: (+27) 10 248 6002
E-mail: lgradidge@grundfos.com
Australia Finland Malaysia
GRUNDFOS Pumps Pty. Ltd. OY GRUNDFOS Pumput AB GRUNDFOS Pumps Sdn. Bhd. Spain
P.O. Box 2040 Trukkikuja 1 7 Jalan Peguam U1/25 Bombas GRUNDFOS España S.A.
Regency Park FI-01360 Vantaa Glenmarie industrial Park Camino de la Fuentecilla, s/n
South Australia 5942 Tel.: +358-(0) 207 889 500 40150 Shah Alam, Selangor E-28110 Algete (Madrid)
Tel.: +61-8-8461-4611 Tel.: +60-3-5569 2922 Tel.: +34-91-848 8800
Fax: +61-8-8340-0155 France Fax: +60-3-5569 2866 Fax: +34-91-628 0465
Pompes GRUNDFOS Distribution S.A.
Austria Parc d’Activités de Chesnes Mexico Sweden
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. 57, rue de Malacombe Bombas GRUNDFOS de México GRUNDFOS AB
Grundfosstraße 2 F-38290 St. Quentin Fallavier (Lyon) S.A. de C.V. Box 333 (Lunnagårdsgatan 6)
A-5082 Grödig/Salzburg Tel.: +33-4 74 82 15 15 Boulevard TLC No. 15 431 24 Mölndal
Tel.: +43-6246-883-0 Fax: +33-4 74 94 10 51 Parque industrial Stiva Aeropuerto Tel.: +46 31 332 23 000
Fax: +43-6246-883-30 Apodaca, N.L. 66600 Fax: +46 31 331 94 60
Germany Tel.: +52-81-8144 4000
Belgium GRUNDFOS GMBH Fax: +52-81-8144 4010 Switzerland
N.V. GRUNDFOS Bellux S.A. Schlüterstr. 33 GRUNDFOS Pumpen AG
Boomsesteenweg 81-83 40699 Erkrath Netherlands Bruggacherstrasse 10
B-2630 Aartselaar Tel.: +49-(0) 211 929 69-0 GRUNDFOS Netherlands CH-8117 Fällanden/ZH
Tel.: +32-3-870 7300 Fax: +49-(0) 211 929 69-3799 Veluwezoom 35 Tel.: +41-44-806 8111
Fax: +32-3-870 7301 E-mail: infoservice@grundfos.de 1326 AE Almere Fax: +41-44-806 8115
Service in Deutschland: Postbus 22015
Belarus kundendienst@grundfos.de 1302 CA ALMERE Taiwan
Представительство ГРУНДФОС в Минске Tel.: +31-88-478 6336 GRUNDFOS Pumps (Taiwan) Ltd.
220125, Минск Greece Fax: +31-88-478 6332 7 Floor, 219 Min-Chuan Road
ул. Шафарнянская, 11, оф. 56, БЦ «Порт» GRUNDFOS Hellas A.E.B.E. E-mail: info_gnl@grundfos.com Taichung, Taiwan, R.O.C.
Тел.: +375 17 397 397 3 20th km. Athinon-Markopoulou Av. Tel.: +886-4-2305 0868
+375 17 397 397 4 P.O. Box 71 New Zealand Fax: +886-4-2305 0878
Факс: +375 17 397 397 1 GR-19002 Peania GRUNDFOS Pumps NZ Ltd.
E-mail: minsk@grundfos.com Tel.: +0030-210-66 83 400 17 Beatrice Tinsley Crescent Thailand
Fax: +0030-210-66 46 273 North Harbour Industrial Estate GRUNDFOS (Thailand) Ltd.
Bosnia and Herzegovina Albany, Auckland 92 Chaloem Phrakiat Rama 9 Road
GRUNDFOS Sarajevo Hong Kong Tel.: +64-9-415 3240 Dokmai, Pravej, Bangkok 10250
Zmaja od Bosne 7-7A GRUNDFOS Pumps (Hong Kong) Ltd. Fax: +64-9-415 3250 Tel.: +66-2-725 8999
BiH-71000 Sarajevo Unit 1, Ground floor, Siu Wai industrial Fax: +66-2-725 8998
Tel.: +387 33 592 480 Centre Norway
Fax: +387 33 590 465 29-33 Wing Hong Street & 68 King Lam GRUNDFOS Pumper A/S Turkey
www.ba.grundfos.com Street, Cheung Sha Wan Strømsveien 344 GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
E-mail: grundfos@bih.net.ba Kowloon Postboks 235, Leirdal Gebze Organize Sanayi Bölgesi
Tel.: +852-27861706 / 27861741 N-1011 Oslo Ihsan dede Caddesi
Brazil Fax: +852-27858664 Tel.: +47-22 90 47 00 2. yol 200. Sokak No. 204
BOMBAS GRUNDFOS DO BRASIL Fax: +47-22 32 21 50 41490 Gebze/ Kocaeli
Av. Humberto de Alencar Castelo Branco, Hungary Tel.: +90 - 262-679 7979
630 GRUNDFOS Hungária Kft. Poland Fax: +90 - 262-679 7905
CEP 09850 - 300 Tópark u. 8 GRUNDFOS Pompy Sp. z o.o. E-mail: satis@grundfos.com
São Bernardo do Campo - SP H-2045 Törökbálint ul. Klonowa 23
Tel.: +55-11 4393 5533 Tel.: +36-23 511 110 Baranowo k. Poznania Ukraine
Fax: +55-11 4343 5015 Fax: +36-23 511 111 PL-62-081 Przeźmierowo ТОВ "ГРУНДФОС УКРАЇНА"
Tel.: (+48-61) 650 13 00 Бізнес Центр Європа
Bulgaria India Fax: (+48-61) 650 13 50 Столичне шосе, 103
Grundfos Bulgaria EOOD GRUNDFOS Pumps india Private Limited м. Київ, 03131, Україна
Slatina District 118 Old Mahabalipuram Road Portugal Tel.: (+38 044) 237 04 00
Iztochna Tangenta street no. 100 Thoraipakkam Bombas GRUNDFOS Portugal, S.A. Fax: (+38 044) 237 04 01
BG - 1592 Sofia Chennai 600 097 Rua Calvet de Magalhães, 241 E-mail: ukraine@grundfos.com
Tel.: +359 2 49 22 200 Tel.: +91-44 2496 6800 Apartado 1079
Fax: +359 2 49 22 201 P-2770-153 Paço de Arcos United Arab Emirates
E-mail: bulgaria@grundfos.bg Indonesia Tel.: +351-21-440 76 00 GRUNDFOS Gulf Distribution
PT GRUNDFOS Pompa Fax: +351-21-440 76 90 P.O. Box 16768
Canada Graha intirub Lt. 2 & 3 Jebel Ali Free Zone, Dubai
GRUNDFOS Canada inc. Jln. Cililitan Besar No.454. Makasar, Romania Tel.: +971 4 8815 166
2941 Brighton Road Jakarta Timur GRUNDFOS Pompe România SRL Fax: +971 4 8815 136
Oakville, Ontario ID-Jakarta 13650 S-PARK BUSINESS CENTER, Clădirea
L6H 6C9 Tel.: +62 21-469-51900 A2, etaj 2 United Kingdom
Tel.: +1-905 829 9533 Fax: +62 21-460 6910 / 460 6901 Str. Tipografilor, Nr. 11-15, Sector 1, Cod GRUNDFOS Pumps Ltd.
Fax: +1-905 829 9512 013714 Grovebury Road
Ireland Bucuresti, Romania Leighton Buzzard/Beds. LU7 4TL
China GRUNDFOS (Ireland) Ltd. Tel.: 004 021 2004 100 Tel.: +44-1525-850000
GRUNDFOS Pumps (Shanghai) Co. Ltd. Unit A, Merrywell Business Park E-mail: romania@grundfos.ro Fax: +44-1525-850011
10F The Hub, No. 33 Suhong Road Ballymount Road Lower
Minhang District Dublin 12 Russia U.S.A.
Shanghai 201106 PRC Tel.: +353-1-4089 800 ООО Грундфос Россия Global Headquarters for WU
Tel.: +86 21 612 252 22 Fax: +353-1-4089 830 ул. Школьная, 39-41 856 Koomey Road
Fax: +86 21 612 253 33 Москва, RU-109544, Russia Brookshire, Texas 77423 USA
Italy Тел. (+7) 495 564-88-00 (495) 737-30-00 Phone: +1-630-236-5500
Columbia GRUNDFOS Pompe Italia S.r.l. Факс (+7) 495 564 8811
GRUNDFOS Colombia S.A.S. Via Gran Sasso 4 Uzbekistan
E-mail grundfos.moscow@grundfos.com
Km 1.5 vía Siberia-Cota Conj. Potrero I-20060 Truccazzano (Milano) Grundfos Tashkent, Uzbekistan
Chico, Tel.: +39-02-95838112 Serbia The Representative Office of Grundfos
Parque Empresarial Arcos de Cota Bod. 1A. Fax: +39-02-95309290 / 95838461 Grundfos Srbija d.o.o. Kazakhstan in Uzbekistan
Cota, Cundinamarca Omladinskih brigada 90b 38a, Oybek street, Tashkent
Tel.: +57(1)-2913444 Japan 11070 Novi Beograd Tel.: (+998) 71 150 3290 / 71 150 3291
Fax: +57(1)-8764586 GRUNDFOS Pumps K.K. Tel.: +381 11 2258 740 Fax: (+998) 71 150 3292
1-2-3, Shin-Miyakoda, Kita-ku Fax: +381 11 2281 769
Croatia Hamamatsu www.rs.grundfos.com
GRUNDFOS CROATIA d.o.o. 431-2103 Japan
Buzinski prilaz 38, Buzin Tel.: +81 53 428 4760 Singapore
HR-10010 Zagreb Fax: +81 53 428 5005 GRUNDFOS (Singapore) Pte. Ltd.
Tel.: +385 1 6595 400 25 Jalan Tukang
Fax: +385 1 6595 499 Korea Singapore 619264
www.hr.grundfos.com GRUNDFOS Pumps Korea Ltd. Tel.: +65-6681 9688
6th Floor, Aju Building 679-5 Faxax: +65-6681 9689
Czech Republic Yeoksam-dong, Kangnam-ku, 135-916
GRUNDFOS Sales Czechia and Slovakia Seoul, Korea Slovakia
s.r.o. Tel.: +82-2-5317 600 GRUNDFOS s.r.o.
Čajkovského 21 Fax: +82-2-5633 725 Prievozská 4D 821 09 BRATISLAVA
779 00 Olomouc Tel.: +421 2 5020 1426
Tel.: +420-585-716 111 Latvia sk.grundfos.com
SIA GRUNDFOS Pumps Latvia
Denmark Deglava biznesa centrs Slovenia
GRUNDFOS DK A/S Augusta Deglava ielā 60 GRUNDFOS LJUBLJANA, d.o.o.
Martin Bachs Vej 3 LV-1035, Rīga, Leskoškova 9e, 1122 Ljubljana
DK-8850 Bjerringbro Tel.: + 371 714 9640, 7 149 641 Tel.: +386 (0) 1 568 06 10
Tel.: +45-87 50 50 50 Fax: + 371 914 9646 Fax: +386 (0)1 568 06 19
Fax: +45-87 50 51 51 E-mail: tehnika-si@grundfos.com
E-mail: info_GDK@grundfos.com
www.grundfos.com/DK
99630288
ECM 1340230
07.2022
www.grundfos.com
Trademarks displayed in this material, including but not limited to Grundfos and the Grundfos logo, are registered trademarks owned by The Grundfos Group. © 2022 Grundfos Holding A/S, all rights reserved.