INSTRUCTION: Choose the BEST answer. Read and understand the questions carefully.
a. Pre-feasibility studies
b. Feasibility studies
c. Site selection analysis
d. Site utilization and land-use studies
a. The People/Public
b. Client
c. Subordinates and Colleagues
d. Contractors
4. In RA9514 Fire code of the Philippines What class of fire if the flame is
started from an “Electrical wiring”?
a. Class A c. Class C
b. Class B d. Class
6. As per RA9514 Fire code of the Philippines. What is the required height of a
building before it is required to be installed with fire Sprinkler System?.
a. 12 mtrs. c. 16 mtrs.
b. 15 mtrs. d. 10 mtrs.
1 of 13
7. It is type of bond where in the cashier’s check or surety bond accompanying
the proposal submitted by the bidder as a guarantee that the bidder will enter
into a contract with the owner if the contract is awarded to him.
11. All manufacturers whose product meet performance or description specified may
bid. All performance and descriptive specifications are open. Brand name
specifications are open if the phrase “or equal”.
2 of 13
16. Automatic fire department notification through central station accredited by
the BFP shall be mandatory to the following types of occupancy:
17. When an exit is required to be protected by separation from other parts of the
building, the construction of the separation shall meet the following
requirements except:
a. The separation shall have at least one (1) hour fire resistance rating
when the exit connects three (3) storeys or less, regardless of whether
the storeys connected are above or below the storey at which the exit
discharge begins.
b. The separation shall have at least two (2) hours resistance rating when
the exit connects four (4) or more storeys, whether above or below the
floor of discharge. It shall be constructed of combustible materials and
shall be supported by construction having at least a two (2)-hour fire
resistance rating
18. As per RA 9514, no single door in a doorway shall exceed _______ in width.
a. 900 mm c. 1200 mm
b. 1000 mm d. 1220 mm
19. Door Panic Hardware devices shall be bars or panel extending not less than
two-thirds (2/3) of the width of the door and placed at heights suitable for
the service required, and shall not be less than ______ nor more than ______
above the floor.
20. Exits shall be so arranged as remote from each other as practicable, so arranged
that there will be no pockets or dead ends in which occupants may be trapped,
and in no case shall any dead-end corridor extend more than _______ beyond the
stairway or other means of exit there from.
a. 3-meters c. 9-meters
b. 6-meters d. 12-meters
3 of 13
21. Referring to Statement #01, what is the value of X.1?
a. 100 mm c. 180 mm
b. 150 mm d. 200 mm
a. 200 mm c. 250 mm
b. 230 mm d. 280 mm
a. 200 mm c. 300 mm
b. 250 mm d. 305 mm
24. As per RA 9514, What is the minimum "new stair" width where the total occupant
load of all storeys served by the stair is fewer than 50, the minimum width
clear of all obstructions, except projections not more than one hundred
fourteen millimeters (114 mm) at or below handrail height on each side, shall
be _______?
a. 750 mm c. 915 mm
b. 800 mm d. 1120 mm
25. As per RA 9514, the elevation of the floor surfaces on both sides of a door
shall not vary by more than _______? The elevation shall be maintained on both
sides of the doorway for a distance not less than the width of the widest leaf.
Thresholds at doorways shall not exceed _______ in height.
a. 10 mm c. 15 mm
b. 13 mm d. 20 mm
26. Which of the following is not a criterion regarding Access to Exits? is not a
part of Contract Documents?
c. Ways of exit access and the doors to exits to which they lead shall be
designed and arranged to be clearly recognizable as such. Decorations or
draperies shall be placed on exit doors. Mirrors shall be placed in or
adjacent to any exit.
4 of 13
d. Exit access shall be arranged that it will not be necessary to travel
toward any area of high hazard occupancy in order to reach the nearest
exit, unless the path is protected by suitable partitions.
28. For violations of failure to provide fire walls to separate adjoining building,
or warehouse and storage areas from other occupancies in the same building,
how many days given for correcting the violation as per IRR of RA 9514?
29. Projections of not more than _______ at a maximum height of nine hundred sixty-
five millimeters (965 mm) within the means of egress on each side shall be
permitted.
a. 114 mm c. 112 mm
b. 122 mm d. 150 mm
30. As per IRR of RA 9514, what is the maximum height allowed in between landings?
a. 2.00 m c. 3.00 m
b. 2.40 m d. 3.66 m
31. These are printed documents stipulating procedural and administrative aspects
of the contract.
a. Special Provisions
b. General Conditions
c. Written Notice
d. Supplementary Contract
a. Environmental Calamities
b. Destructive Calamities
c. Act of God/Force Majeure
d. Act of Man
a. Provide c. Furnish
b. Install d. Work
5 of 13
a. I,II,III,IV,V
b. II,III,V,VI,VII
c. II,III,V,VI,VII
d. I,III,IV,VI,VII
35. These are instructions that supplement or modify drawings, specs, and general
conditions of the contract.
36. The cashier’s check or bidders bond accompanying the proposal submitted by the
bidders as a guarantee that the bidder will enter into a contract with the
owner for the works if the contract is awarded to him.
37. A guarantee to the pay all obligations arising from his contract. UAP Doc 301
38. A guarantee to the quality of materials and equipment installed and the
workmanship performed by the contractor. UAP Doc 301
39. A guarantee to the execution of the work in accordance with the terms of the
contract.
40. To build in, mount in positions, connect or apply any object specified ready
for the intended use.
a. Provide c. Furnish
b. Install d. Work
41. Architect A. Mamangun owns the new graphic studio being constructed at Camp
John Hay Technohub, Baguio City designed by Architect C.Mamangun. In the mid-
year of the construction, J.Bildan, the main contractor failed to make payments
to sub-contractors, workmen and dealers. The owner, disappointed with the
situation decided to terminate the contract with J.Bildan. Within how many
days upon certification of Ar. C.Mamangun justifying his action, may the owner
terminate the contract with J.Bildan?
42. A new residential tower owned by Ar. U.Barut is being constructed at Quezon
City, Manila designed by Ar. J.Dela Cruz and took Ar. J.Bildan as the main
contractor. In the early stages of the construction, a portion of the tower
collapsed and caused damages in the owner’s property and the adjoining property
of Ar. A.Mamangun due to lack of erected barriers and supports. Who will be
responsible and paying for the damages in Ar. A.Mamangun’s property?
6 of 13
a. Ar. U.Barut
b. Ar. J.Bildan
c. Ar. A.Mamangun
d. Ar. J.Dela Cruz
43. Prior to the issuance of the certification of completion, the contractor must
execute a written undertaking to finish any work during the period of making
good of known defects or faults with period of not more than?
a. 10 days c. 30 days
b. 15 days d. 60 days
44. How many sets of prints of shop drawings shall the contractor submit to the
architect for approval?
a. 2 c. 5
b. 3 d. 7
45. How many sets of drawings and specs shall the owner furnish the contractor for
free?
a. 2 d. 7
b. 3 e. None
c. 5
46. The Architect shall promote the interest of his professional organization and
do his full part of the work to enhance the objectives and services of the
organization. He should share in the interchange of technical information and
experience with the other design professions and the building industry. This
is Architect Responsibility in relation to whom?
47. The Architect shall explain the conditional character of estimates other than
estimates submitted in the form of actual proposals by contractors and in no
case shall be guarantee any estimates or cost of the work. Neither shall he
mislead his Client as to probable cost of the work in order to secure a
commission. This is Architect Responsibility in relation to whom?
48. Drawings, specs and models are property of whom and are to be returned at
completion of work and before final payment to the contractor is made?
a. Owner
b. Architect
c. Contractor
d. It doeesn’t matter who takes it
a. Architect c. Contractor
b. Engineer d. Project Representative
7 of 13
50. Full time construction inspector hired by the woner assisting in the
supervision of the work.
a. Architect c. Contractor
b. Engineer d. Project Representative
51. As per BP344, hand rails shall be installed at __m and __m above steps or
ramps. Handrails for protection at great heights may be installed at __m to
__m.
52. As defined by BP344, ___ is an exterior passage for walking along, especially
one connecting adjoining buildings and related structures.
a. Hallway c. Eskinita
b. Catwalk d. Walkway
54. As per BP344, the length of wheelchairs varies from __m to __m; width of __m
to __m.
55. As per BP344, any person violating any provision of the act, upon conviction
by a court of competent jurisdiction, shall suffer the penalty of imprisonment
of not less than __, or a fine of __ or both, at the discretion of the court.
a. Alcove c. Ingress
b. Cove d. Niche
57. As per BP344, Rule V Administration and Enforcement- the Secretary through the
heads of attached agencies of the DPWH, with the technical assistance of the
Building Research Development Staff, shall administer and enforce the
provisions of the Rules and Regulations through the City/Municipal Engineer
who shall act as Local Building Official pursuant to Section 477 of RA7160,
otherwise known as the local Government Code of 1991 and as applied to the
following:
8 of 13
58. As defined by BP344, __ a break in the sidewalk or traffic island provided
with an inclined surface to facilitate mobility of wheeled chairs, carriages
and other similar conveyance.
59. As per BP344, signs on walls and doors should be located at a __ height of __m
and a __ height of __m.
60. As per BP344, accessible parking slots should have a minimum width of __m.;
and a walkway from accessible spaces of __m. clear width shall be provided
between the front ends of parked cars.
61. As per BP344, doors should be openable by a pressure or force not more than
__kg, the closing device pressure of an interior door shall not exceed __kg.
62. As per BP344, A ____ of __m. shall be installed before hazardous areas such as
sudden changes in floor levels and at the top and bottom of stairs.
63. As per BP344, shall be kept to a minimum; whenever necessary, shall have a
maximum height of 25mm and preferably ramped.
a. Accessible elevators should be located not more than 30.0m from the
entrance and should be easy to locate with the aid of signs.
b. Accessible elevators shall have a minimum dimension of 1.10m x 1.40m.
c. Button controls shall be provided braille signs to indicate floor level.
d. Button sizes at elevator control panels shall have a minimum diameter of
20mm and should have a maximum depression depth of 1mm.
e. None of the above.
9 of 13
66. Under PD 957, What is minimum lot area of single attached for open market?
a. 80 c. 60
b. 96 d. 100
67. What is the minimum lot frontage of Single Detached Corner Lot?
a. 12 c. 6
b. 10 d. 8
68. Development permit issued by a local government unit for a subdivision project
is valid for?
a. 1 Year c. 5 Years
b. 3 Years d. 10 Years
a. Urinals should have an elongated lip or trough type; the maximum height
of the lip should be 0.48m.
b. Maximum height of lavatories should be 0.80m with the knee recess of
0.60-0.70m vertical clearance and a 0.50m depth.
c. Water closet flush control should have a maximum height of 1.20m
d. The maximum height of water closets should be 0.45m
e. All of the above.
70. Amends the Sec. 31 of P.D. 957 on provision of open spaces in a residential
subd. project
a. PD 9161 c. RA 9161
b. PD 1216 d. RA 1216
71. What is the minimum lot area of Rowhouses for open market housing?
72. What is the minimum lot area of Rowhouses for medium cost housing?
a. 80 sq.m c. 50 sq.m
b. 60 sq.m d. 40 sq.m
73. In residential open market housing under PD 957 with a right of way of 15
meters, its Planting strip measurement is?
74. An Act Providing for a More Responsive and Comprehensive Regulation for the
registration, Licensing and Practice of Architecture, Repealing for the Purpose
Republic Act No. 545, as Amended, Otherwise Known as “An Act to Regulate the
Practice of Architecture in the Philippines,” and for Other Purposes
a. RA 9266 c. PD 1096
b. RA 545 d. RA 8981
a. RA 5914 c. RA 9514
b. RA 5941 d. RA 9541
10 of 13
76. Standards for Economic and Socialized Housing Projects
a. PD 957 c. BP 220
b. BP 344 d. RA 4726
77. Under 957, How many liters per capita per day for household connection?
78. How many units in rowhouses are allowed per block/cluster but in no case shall
this be beyond 100 meters in length?
80. The Architecture profession shall be integrated into one (1) national
organization which shall be accredited by the Board, subject to the approval
by the Commision, as the integrated and accredited professional organization
of architects.
a. Reciprocality c. Reciprocity
b. Reflexibility d. NOTA
11 of 13
85. The architect registered and licensed or permitted to practice under R.A. No.
9266, who is professionally and academically qualified and with exceptional or
recognized expertise or specialization in any branch of architecture.
a. Consulting Architect
b. Architect-of-Record
c. Architect
d. Architect-in-charge of construction
a. II, III, IV
b. I, II, III, IV
c. I, II, III, V
d. I, II, III
89. A group of two or more Architects duly registered with the SEC and then with
the Board of Architecture. (Sec 3)
12 of 13
92. As per BP 220 RULE II Section 4, rearrange the basic needs of human settlements
in descending order..
I. WATER
II. STORM DRAINAGE
III. POWER
IV. PARK/PLAYGROUND
V. MOVEMENT AND CIRCULATION
VI. SOLID AND LIQUID WASTE DISPOSAL
93. As per BP 220 RULE II Section 4, which one does not belong to the basic needs
of human settlements, wherein the provision of these basic needs shall be based
on the actual setting within which the project site is located?
I. WATER
II. ACCESS TO FOOD
III. POWER
IV. PARK/PLAYGROUND
V. MOVEMENT AND CIRCULATION
VI. RECREATIONAL FACILITIES
a. II c. Both A & B
b. VI d. None of the choices
94. As per BP 220 RULE II Section 5, for projects 1 hectare or above, area allocated
for parks and playgrounds shall be mandatory. What is the minimum area
allocation for parks and playgrounds?
95. As per BP 220 RULE II Section 5, the minimum right-of-way of major roads shall
be in accordance to the standards provided in the BP220. However, in cases
where the major road will serve as interconnecting road, what should be the
minimum right-of-way?
a. 8 meters c. 12 meters
b. 10 meters d. 15 meters
13 of 13