Technical Datasheet

1 FXVS 1218C-24T-O Exact unit dimensions and weights may be influenced by accessories/option
combinations.
Main Accessories :
EVAPORATIVE COIL DATA - UNITARY
THERMAL DESIGN DATA Evaporative coil type ....................................................................................... Bare / HDG
Requested capacity (overall/unitary) .................................................................... 1197 kW Evaporative coil arrangement ................................................................... Wet coil - 1pass
Max. capacity (overall/unitary) (@ 100% RPM) ......................................... 1197 / 1197 kW Evaporative coil inlet connections .................................................................. (2x) ND 150
Fluid type ............................................................................................................. 25% EG Evaporative coil outlet connections ................................................................ (2x) ND 150
Freezing point .......................................................................................................... -12 °C Evaporative coil volume ................................................................................. (1x) 1656.0 l
Requested fluid flow (overall/unitary) ..........................................................61.22 / 61.2 l/s Evaporative coil surface ............................................................................... (1x) 301.0 m²
Max. fluid flow (overall/unitary) (@ 100% RPM) ..........................................61.22 / 61.2 l/s Evaporative coil dry weight ......................................................................... (1x) 4185.0 kg
Entering wet bulb temp .......................................................................................... 25.0 °C
Entering dry bulb temp ........................................................................................... 37.0 °C ELECTRICAL DATA - UNITARY
Process fluid inlet temperature .............................................................................. 33.0 °C Fan motor
Process fluid outlet temperature ............................................................................ 28.0 °C General
Operating mode ........................................................................................................... Wet Fan motor BHP (Net mech output power at motor shaft) .................. (3 x) 10.3 kW
Fan motor oversized for
PHYSICAL DATA (including accessories) - UNITARY Total ESP .................................................................................................... 0 Pa
Overall length ...................................................................................................... 6190 mm Accessories total external static pressure .............................................. 0 Pa
Standard unit ................................................................................................. 5480 mm Customer external static pressure .......................................................... 0 Pa
Pump 1 ............................................................................................................ 710 mm Dry operation allowed ..................................................................................... No
Overall width ....................................................................................................... 3607 mm Fan motor voltage .......................................................................................... 400 V
Standard unit ................................................................................................. 3607 mm Frequency ...................................................................................................... 50 Hz
Overall height ...................................................................................................... 6230 mm Protection class ................................................................................................ IP55
Standard unit ................................................................................................. 6230 mm Mounting ............................................................................................................. V6
Shipping / operating weight .................................................................... 10720 / 17320 kg Single speed
Standard unit .................................................................................... 10720 / 17320 kg Fan motor power ................................................................................ (3 x) 11.0 kW
Heaviest section ................................................................................................... 7510 kg Efficiency level fan motor ................................................................................... IE3
Casing Material option .................................................... BALTBOND HYBRID COATING Fan full load current (Nominal Voltage) ..................................(3 x) 21.2 A ( 400 V )
Basin Material option .......................................................................................... SST316L Fan synchrone speed .............................................................................. 1500 RPM
Overflow diameter ...................................................................................... (1x) ND 80 mm Framesize .......................................................................................................... 160
Make up diameter ...................................................................................... (1x) ND 40 mm Spray pump motor power ................................................................................ (1x) 7.5 kW
Drain diameter ........................................................................................... (1x) ND 50 mm Efficiency level pump motor ......................................................................................... IE3
Number of coils per unit ................................................................................................... 1 Spray pump motor voltage ....................................................................................... 400 V
BAC ref. :FXVS 1218 24TO
Customer : 2021-04-27
Project :TOGG BALTIMORE AIRCOIL P 1/4
Office : S2Q V 3.7.3 quoteNr:
User :okde
Technical Datasheet
Frequency ................................................................................................................. 50 Hz All acoustical data as sound pressure levels at quietest side of unit at indicated distance.
Spray pump full load current ............................................................... (1x) (16.0 A ) 400 V Values are obtained according to CTI ATC-128,2019 (Test Code for Measurement of
Spray pump synchrone speed .......................................................................... 1000 RPM Sound From Water-Cooling Towers) for small towers with a 2 dB(A) tolerance.
Protection class
Mounting ACCESSORIES - Construction details UNITARY
Framesize .................................................................................................................... 160 Connection - extra in pan
* Note: For indicative cable sizing the "Fan Full Load Current" and the corresponding
"Nominal Voltage" have to be used. ACCESSORIES - Motor accessories UNITARY
* To prevent moisture ingress in fan motors installed in the wet discharge air stream, PTC (only) (for fan motor)
these fan motors have space heaters. The space heaters should be activated whenever
Protective coating for hostile/corrosive environment (fan motor)
the fan motor is idle. Units with motors outside the unit do not have space heaters as
standard execution but are available as an option. Space heaters (induced draft)
Phase ................................................................................................................... 1 Ph.
Voltage .................................................................................................... 220-240 VAC
AERODYNAMICAL DATA - UNITARY
Frequency ........................................................................................................... 50 Hz
Air flow (100% RPM/100% RPM) ............................................................. 75.1 / 75.1 m³/s
Tropicalization (for fanmotors)
Number of fans ................................................................................................................ 3
Fan type ..................................................................................................................... Axial
Approximate Fan speed ...................................................................................... 611 RPM ACCESSORIES - Winterisation package UNITARY
Pan heater package 1*16 kW-Standard
1 stage thermostat
HYDRAULICAL DATA - UNITARY
Protection class ............................................................................................... IP 54
Total pressure drop (@61.2 / 61.2) ............................................................. 69.0 / 69.0 kPa
Rating (@250VAC) .......................................................................................... 10 A
Standard unit ........................................................................................ 69.0 / 69.0 kPa
Contacts ................................................................................................ NO and NC
Spray water flow ............................................................................................. (1x) 85.2 l/s
Temperature range ..................................................................................-20..50 °C
Maximum evaporation ..............................................................................0.776 / 0.776 l/s
Low level cut out switch with integral stilling chamber
Bleed (cycles of concentration 2.5) ..........................................................0.517 / 0.517 l/s
Contacts ................................................................................................... NO or NC
Make-Up (cycles of concentration 2.5) ....................................................1.293 / 1.293 l/s
Index of protection ........................................................................................... IP 65
Pan volume operating .............................................................................................. 2038 l
Voltage ...................................................................................................... 240 VAC
Pan volume overflow ............................................................................................... 5217 l
Rating (@240VAC) ............................................................................................ 1 A
Pressure range mechanical make-up valve ..................................................... 1 to 3,5 bar
Pan heater 16 kW
Voltage ...................................................................................................... 400 VAC
Acoustical data (Standard unit no attenuation )
Index of protection
100 % RPM (@ 15.0m ) ........................................................................................ 62 dB(A) Phase .............................................................................................................. 3 Ph.
Sound Power Level (@100 %RPM) ................................................................ 109.0 dB(A) Rating (@400VAC) ....................................................................................... 23.2 A
Power .............................................................................................................16 kW
BAC ref. :FXVS 1218 24TO
Customer : 2021-04-27
Project :TOGG BALTIMORE AIRCOIL P 2/4
Office : S2Q V 3.7.3 quoteNr:
User :okde
Technical Datasheet

ACCESSORIES - Installation & maintenance package UNITARY


Additional access door opposite end (standard)
Extended lubelines (not required when internal service platform)
Internal lower walkway

ACCESSORIES - Export shipments UNITARY


Internal Coil Corrosion protection (flanges,if applicable, are shipped loose)
Pump shipped loose (for overseas transport)

ACCESSORIES - Instrumentation UNITARY


Low level cut out switch with integral stilling chamber
Voltage ............................................................................................................ 240 VAC
Index of protection ................................................................................................ IP 65
Contacts ........................................................................................................ NO or NC
Rating (@240VAC) .................................................................................................. 1 A

note
Thermal performance at design conditions and total standard fan motor power is
CTI/ECC certified
For safety reasons ladders are only allowed in combination with railing.

BAC ref. :FXVS 1218 24TO


Customer : 2021-04-27
Project :TOGG BALTIMORE AIRCOIL P 3/4
Office : S2Q V 3.7.3 quoteNr:
User :okde
Customer : BAC ref. :FXVS 1218 24TO
Project :TOGG BALTIMORE AIRCOIL 2021-04-27
Office : S2Q V 3.7.3 P 4/4