50 Horas

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

22/11/23, 0:05 SIS 2.

Every 50 Service Meter Units (SEBU5791-04)

SMCS -

(6)Zinc Plugs
Salt Water Applications Only
PPI
1. Move the battery disconnect switch to the OFF position.
-
202 007 0
2. Remove all the zinc plugs. They are painted red for easy identification.

3
03: 11/2 37B
/ 2
0 5
SEB :50- 2
U
© 2 579 3:00 0
3. Tap the zinc rods lightly with a hammer. If the rod has deteriorated, or flakes when tapped, install a new zinc rod.

Installing New Zinc Rods


023 1
Cat
erp
illa
1. Unscrew or drill the existing rod from the plug base.
rI nc.
2. Install a new rod in the plug base.

https://sis2.cat.com/#/print-preview/service/6c0657ed-41e5-46a4-a484-75c417987a11 1/2
22/11/23, 0:05 SIS 2.0

3. Install the plug.

(7)Batteries

Do not smoke when observing battery electrolyte level. Batteries


give off fumes that can explode.

Electrolyte is an acid and can cause personal injury if it contacts


skin or eyes.

1. Clean the top of the batteries and remove the fill caps. Observe electrolyte level.

2. Maintain the electrolyte level to the bottom of filler openings. Use distilled water.

3. If the battery posts and cable clamps are corroded, clean them with a solution of baking soda and water.

4. Tighten the clamps and coat them and the battery posts with grease.

PPI-0007237B
2023/11/22
03:05:45-03:00
SEBU57910013
© 2023 Caterpillar Inc.

https://sis2.cat.com/#/print-preview/service/6c0657ed-41e5-46a4-a484-75c417987a11 2/2